Homeowners Install Infiltrator Septic System in Alaska July 5-10 2017

  Рет қаралды 54,078

Kendrick Homestead

Kendrick Homestead

7 жыл бұрын

We took the homeowners installation course offered online by the Alaskan Department of Environmental Conservation (DEC). Research led us to choose the Infiltrator system to serve our needs. We followed all the state requirements for installation. The regional state rep was extremely helpful answering many questions over the phone and through email, as well as coming out to the site to give us feedback after most of the system was in place.This was quite an undertaking for amateurs, but the cost savings was worth it. Considering we were given a bid of $10,000 to have a contractor install...well, the system cost us $3500, so you can do the math on the savings for this project (minus the sweat equity and occasional arguing with your spouse -- "no, no, dear, that chamber attaches there!")!!

Пікірлер: 29
@kenairockband
@kenairockband 4 жыл бұрын
It’s good practice to fill the tank prior to backfilling.
@dougmac8904
@dougmac8904 6 жыл бұрын
Nice. I have to put mine deeper under clay about 5 ft down. Hope it will still work for me. Thanks again. From North Carolina, Greensboro
@aurelioartica8569
@aurelioartica8569 3 ай бұрын
Where you buy and how cost and how many come
@michaelmichaud5416
@michaelmichaud5416 5 жыл бұрын
Three feet( need in between edge to edge) . The tight , side by side defeats purpose drain filed . This is a drain pond. Need remove two of 4 laterals, I would disconnect them, switch back fourth this will extend life .
@JoeSmith-dh1rz
@JoeSmith-dh1rz 4 жыл бұрын
That's why you have to overkill it so it doesn't pond
@DiGiTaLdAzEDM
@DiGiTaLdAzEDM 4 жыл бұрын
Is the proper approach to have the entire trench length beneath the chamber totally level? No slight drop? In my area the recommendation for pipe in stone drainfield is 2 inches of drop/60 feet.
@rawnwalsh
@rawnwalsh 3 жыл бұрын
My system is designed to allow 6 feet between chambers, Kremmling CO
@fredypinto9221
@fredypinto9221 4 жыл бұрын
how many pieces of leaching filters do we need for a 2 bath and a 1000 gallons tank
@imaginationdronellc5762
@imaginationdronellc5762 3 жыл бұрын
Does Alaska show approval for these tanks? Im not finding the info for infiltration tank for AK anyway
@mayers19851ify
@mayers19851ify 2 жыл бұрын
What part of AK are you in? Considering this in Willow.
@lakeh230
@lakeh230 3 жыл бұрын
How much did the entire system cost, minus the heavy equipment charges?
@JoeSmith-dh1rz
@JoeSmith-dh1rz 3 жыл бұрын
You got more than enough chambers for almost two houses lol
@olddave4833
@olddave4833 3 жыл бұрын
that's what i thought, water will never get to the other end
@earthling2007
@earthling2007 2 жыл бұрын
Classic over kill.
@Zeahappy
@Zeahappy 2 жыл бұрын
are u folks in the valley?
@jiedongplasticmachinery
@jiedongplasticmachinery Жыл бұрын
We are professional manufacturers of HDPE large diameter spiral extrusion lines.
@thomasalley4944
@thomasalley4944 3 ай бұрын
Wow....get the rocks out
@dougmac8904
@dougmac8904 6 жыл бұрын
does this work without having 3 foot between each one?
@kendrickhomestead4750
@kendrickhomestead4750 6 жыл бұрын
Yes. There's about 3 feet between the center of each row, and according to the installation specs, that is sufficient. We really like the versatility of Infiltrator. Currently, we are still in house building stage, so we have not tested the system's full capacity yet. Once we get a toilet and such hooked up, we will update this post! :)
@dougmac8904
@dougmac8904 6 жыл бұрын
Kendrick Homestead thanks for t&e information. I want to use that system. What cost for the system. How many feet needed?
@kendrickhomestead4750
@kendrickhomestead4750 6 жыл бұрын
Around $2500 for the system and pvc. For the feet that depends on a few factors, I believe ours was 162 feet of leech field.
@davidbrewer7937
@davidbrewer7937 6 жыл бұрын
That was my initial thought when I watched this. The chamber spacing is normally set by local bylaw...
@normnelson5103
@normnelson5103 3 жыл бұрын
I'm interested how these infiltrator's were back filled to my knowledge they are highly susceptible to cave-in and lose of effluent flow. Back fill of your inlet pipe also very important it's very easy to lose the flow line into the chanmbers. Do it yourself'ers beware there is a lot of hidden things you don't see that can go wrong water doesn't flow uphill and pipes separate.
@normnelson5103
@normnelson5103 3 жыл бұрын
Do-it yourself-ers beware there are a lot of hidden things you don't see literally back filling improperly causes chamber collapse lose of line separation of pipe from chamber due to lack of support Lots of $ lost in materials
@akbychoice
@akbychoice 2 жыл бұрын
So, you don’t need to be licensed to install a septic system?
@melissarodabaugh3318
@melissarodabaugh3318 2 жыл бұрын
Not a gravity fed one in most states.
@JoeSmith-dh1rz
@JoeSmith-dh1rz 3 жыл бұрын
shit will last five years plugged with roots and sand
@JoeSmith-dh1rz
@JoeSmith-dh1rz 4 жыл бұрын
Tanks are junk
@imaginationdronellc5762
@imaginationdronellc5762 3 жыл бұрын
Haven’t had any issues and I’m an installer. May not recommend for sub zero temp but southern AK and lower 48 good to go
How to Install Septic Tank and Leach Field (with COSTS!)
22:22
Piney Grove Homestead
Рет қаралды 108 М.
DIY Septic Install Part 1 Infiltrator 1060 Septic Tank & 4 Hole D-Box
18:44
Red & April Off-Grid
Рет қаралды 35 М.
1 or 2?🐄
00:12
Kan Andrey
Рет қаралды 32 МЛН
터키아이스크림🇹🇷🍦Turkish ice cream #funny #shorts
00:26
Byungari 병아리언니
Рет қаралды 28 МЛН
He sees meat everywhere 😄🥩
00:11
AngLova
Рет қаралды 10 МЛН
Children deceived dad #comedy
00:19
yuzvikii_family
Рет қаралды 7 МЛН
Arc Leachfield Chamber Installation - Advanced Drainage System
5:15
Advanced Drainage Systems, Inc.
Рет қаралды 449 М.
Septic Mound System Installation using Infiltrator Chambers
13:50
Infiltrator Water Technologies
Рет қаралды 117 М.
Your Septic System: Worst Mistakes
16:44
Sachs Realty
Рет қаралды 1,5 МЛН
We Installed A Gravity Septic System!
10:06
Simple Ground
Рет қаралды 162 М.
Overview of Septic Systems
26:29
PublicResourceOrg
Рет қаралды 1,8 МЛН
Tiny Home Septic System INSTALLED BY HAND!
16:10
The Nomadic Movement
Рет қаралды 231 М.
Septic School Pro Tips: Installing Infiltrator Septic Tanks
9:41
Septic School
Рет қаралды 1,5 М.
Infiltrator Full Septic System Installation
5:22
Salina Septic Service
Рет қаралды 43 М.
Low Profile Chamber Septic System Install
9:57
NC Barndo Build
Рет қаралды 9 М.
1 or 2?🐄
00:12
Kan Andrey
Рет қаралды 32 МЛН