In this HVAC Training Video, I Show Honeywell Thermostat Wire Terminals, Functions, Color Code , and Overall Instructions for Use! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Get the Thermostat Used in the Video Here!
T1 Honeywell Non-programable Thermostat: amzn.to/3rQt7cD
T4 Honeywell Programable Thermostat: amzn.to/3T59MQL
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• Teaching Thermostat Fu...
• How to Fish THERMOSTAT...
• Be Aware of These 6 TI...
• How an Air Handler & H...
• Top 10 Thermostat Rela...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #thermostat #terminal #function #colorcode
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 165
@AAtta-3286
@AAtta-3286 Жыл бұрын
The BEST explanation of a Honeywell thermostat install I've seen! I just purchased a T6 zwave Honeywell pro series thermostat and your video helped my install tremendously. Many thanks for a very detailed video
@Dw-zs2et
@Dw-zs2et Жыл бұрын
You're the only one that covered all my questions. Great video .
@johnwsharpe4063
@johnwsharpe4063 8 ай бұрын
Thank you so much for this video. I was upgrading from a very old thermostat to this model, and your explanations clarified everything!
@PedroGonzales-fo9zd
@PedroGonzales-fo9zd Жыл бұрын
Very timely; I ended up with an Ecobee installation; however, you should know I have followed your channel for over 3 years; my home system which is 3 years old and installed by a reputable HVAC company because I was away from the area and my wife needed AC during a heat wave. Bottom line, the Bryant thermostat went blank; I followed one of your diagnostic instruction videos, and located a wire short in the condenser, tested all components and wires, and kept telling my wife I thought it was the thermostat! Since the unit is under warranty, the HVAC installer diagnosed and replaced the thermostat (with Ecobee). BTW, the 3amp little popper is a must with this type of diagnostic workflow. Thank you.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks Pedro!
@garza7676
@garza7676 Жыл бұрын
Thank you so much for making this video . A much needed updated on all the newer thermostat , which everyone wants now.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks a lot Charlie!
@RyanEhli-MusicAndGuitar
@RyanEhli-MusicAndGuitar 9 ай бұрын
Excellent explanation of each wire's function - functionality of each wire location (more specifically). Great information!
@acservicetechchannel
@acservicetechchannel 9 ай бұрын
Thanks for watching our video!
@RobertMChambers
@RobertMChambers Ай бұрын
Thanks for this... had a A/C no compressor start problem after doing a breaker identification exercise. Found my yellow line not continuous to the compressor. Traced that back to a failsafe connection on the condensate pump. If the pump stopped it would shut down the compressors. That pump was plugged into an outlet we couldn't identify. Once power was restored to that the compressor started. Your description of how the wiring works gave me a much better handle on how to track it down. Thank you again!
@bakermark6891
@bakermark6891 Ай бұрын
Excellent video and instrucciones!! The Best I've sen so far!!! Keep them coming brother
@zAlaska
@zAlaska 8 ай бұрын
I bought a Royalton 2-stage furnace. I gave it to my friend and it is 60 miles away from here, I have never been able to make this Honeywell thermostat work, I bought one before and we gave up on it as we did in this case again. The furnace says not to hook up the C wire but it doesn't talk about two-stage thermostat connections. I don't know what to switch position is I will check it when I go back to town but we could not get it to operate heat at all. And I contacted them but it was Friday so it's the weekend now and I appreciate the knowledge that I got from this video. I'll get back to you and tell you my progress and we'll check out your wiring charts. I checked out your thermostat wiring charts and it doesn't talk about two-stage furnaces. I would prefer the old-fashioned double Mercury thermostat without all the confusion, and they're not on offer at Lowe's Home Depot.
@tubehead357
@tubehead357 6 ай бұрын
I just took a T2 back to the store thinking it was broken! Your explanation of each wire is very helpful! The instructions in the box are worthless! Thanks!
@maluu6192
@maluu6192 4 ай бұрын
THANK YOU SO MUCH ❤ You saved me so much money and a migraine 😅 Many BLESSINGS TO YOU!!!!
@billlong3059
@billlong3059 11 ай бұрын
Excellent, exactly what I needed versus installation instructions which left many questions unanswered. Honeywell owes you at AC Service Tech bigtime!
@spikekavalench
@spikekavalench 6 ай бұрын
Agree, very informative.
@marconantel7735
@marconantel7735 Жыл бұрын
I’ve come to like the new Honeywell/Resideo stats. The set up programming is not intuitive, but they are pretty flexible in what they can do
@mondavou9408
@mondavou9408 8 ай бұрын
This was great! Thumbs up. Fantastic instructions for a complete newbie DIY'er.
@MrWaynesea
@MrWaynesea Жыл бұрын
Excellent! Thanks for the tutorial. Very relevant.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks a lot Jonathan!
@carlsbadidea8639
@carlsbadidea8639 4 ай бұрын
Best explanation yet! I found that the installer incorrectly wired my T6 so it never ran properly from day one. They had the white wire on "W" which is wrong for a heat pump system. I replaced it with an RTH8500 unit and I also have noticed that the outside unit runs much quieter now. I'm not sure why but the T6 was the date code that is supposed to be defective.
@paulrozinski1488
@paulrozinski1488 Жыл бұрын
Another great, informative video. Thanks again 👍
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks a lot Paul!!
@user-kf8hn5ro2n
@user-kf8hn5ro2n Жыл бұрын
Thank You so much for your detailed info, You really helped me tremendously!!
@TKESB_AZ
@TKESB_AZ Жыл бұрын
Excellent video! Many thanks.
@Jury.13
@Jury.13 7 ай бұрын
Definitely the most informative video producer of all time! Thank you for what and how you do it!!
@acservicetechchannel
@acservicetechchannel 7 ай бұрын
Glad it was helpful, thank you for watching!
@charlesprouty213
@charlesprouty213 7 ай бұрын
Excellent video, great information on what each wire controls. Thank you AC Service Tech!
@acservicetechchannel
@acservicetechchannel 7 ай бұрын
Thanks for watching!
@victoriavishloff8207
@victoriavishloff8207 9 күн бұрын
Thank God for this video. I just moved into a brand new build and the idiots didn't wire in the G wire 😭 it's 27°c in my room right now
@JoseRamirez-ph2gv
@JoseRamirez-ph2gv 5 ай бұрын
Thank you for the help!!! Your instructions were great
@rv10flyer84
@rv10flyer84 Жыл бұрын
They did me in on on their T6 issues. I like Pro1 now.
@hvacmisadventures
@hvacmisadventures Жыл бұрын
God I replaced soooo many t6's on call backs lol
@brianmcdermott1718
@brianmcdermott1718 Жыл бұрын
Great info. Craig. Thank you.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks a lot Brian!
@The73rdSecret
@The73rdSecret Жыл бұрын
Great explanation
@alangarcia32
@alangarcia32 Жыл бұрын
Excelente tutorial
@Shagggy67
@Shagggy67 6 ай бұрын
Great video. Im looking to upgrade to a wifi thermostat for my heat pump and this video will definitely help. I just need to figure out where to connect my unconnected c wire in the pump unit .
@williamholley1232
@williamholley1232 Жыл бұрын
This is great content thank you
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks William!
@mustkeemanwar8755
@mustkeemanwar8755 Жыл бұрын
So nice explained thanks
@indiantraveller194
@indiantraveller194 Жыл бұрын
Good explain sir
@Mudcat597
@Mudcat597 Жыл бұрын
Nice presentation 👍👍
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanks Roy!
@drewcarlisle1
@drewcarlisle1 Жыл бұрын
This was a Very Helpful video that allowed me to install our new thermostat with confidence. And... IT WORKED ! There were only two wires (black and white) and the instructions were Not Clear, but this video was. R & C is all we needed. Thank You.
@maraxis1985
@maraxis1985 4 ай бұрын
This helped me out so much. I just bought a house and there are only 4 wires with this unit and they used the blue wire for the Y. I think this gives me a way to get a C Wire and keep the other 4 connected.
@judodavid1
@judodavid1 Жыл бұрын
Thank yo for the knowledge
@wahid6725
@wahid6725 Жыл бұрын
ty for ur educational video
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Glad to help wahid!
@MarkJones-jb7iz
@MarkJones-jb7iz 4 ай бұрын
I just got a lesson in thermostats by a guy that sounds like shoresy. Hell yeah
@Level-333
@Level-333 Жыл бұрын
Honeywell always made my system run all the time. Changed to a WR/Emerson and it’s running normal. I used to think all thermostats were the same but nope!
@HVACRTECH-83
@HVACRTECH-83 Жыл бұрын
You didn't wire it correctly. How is that honeywells fault? Seriously.
@alimahdavi01
@alimahdavi01 Жыл бұрын
Thanks for this useful video. In case of water source heat pump, do we need W terminal to be wired?
@riguicaminero
@riguicaminero Жыл бұрын
Gracias
@tphvac87
@tphvac87 Жыл бұрын
I’ve like the T6 model but the WiFi ones I’ve had burn out ALOT!! Has anyone else had these issues? Nice video Craig!
@AAtta-3286
@AAtta-3286 Жыл бұрын
I know it's been a while since your post but came across an HVAC video concerning your problem . Apparently Honeywell had an issue with some of these thermostats . If you look at the back of your thermostat an on the red label you'll see the model number. Right after that should be a 4 digit number. The problem thermostats have a code between 1917 through 1940 per that video. I'm betting your problem thermostats fell between that range. Best of luck.
@oiygfdxssfgg
@oiygfdxssfgg 4 ай бұрын
Thanks for posting this
@lesliealexander2485
@lesliealexander2485 23 күн бұрын
2:26
@velvin9
@velvin9 10 ай бұрын
Thank you. This video helped me install our new T5 thermostat. Honeywell’s direction was not as comprehensive.
@acservicetechchannel
@acservicetechchannel 10 ай бұрын
You're welcome!
@bdailey8065
@bdailey8065 15 күн бұрын
​@@acservicetechchannelCan you please help me sir? I just installed a Honeywell T5 smart thermostat tonight and can't get it to power up after I turned the power back on at the fuse box.
@renorussell7031
@renorussell7031 Жыл бұрын
Do you have a recommendation of how to connect the new smart thermostat to a panel that previously used an EIM?
@rotaxrider
@rotaxrider Жыл бұрын
Do you have a video that covers using a wall mounted IR thermostat like a Flair puck style for a mini split?
@tomfromtacomas7249
@tomfromtacomas7249 Жыл бұрын
Great information! You could also change the title of this to include the Amazon thermostat and you would get a lot of additional views.
@brianperry4815
@brianperry4815 8 ай бұрын
Tom Do you have the Amazon stat ? ? My pro tech stat fried so I am looking t that stat to replace old one. Static power fried the display.
@nov141992tim
@nov141992tim Жыл бұрын
Nice video. thank you for taking the time to make it and explain this in detail. I'm hoping you and or knowledgeable others would be willing to comment to my question, please. I am having installed, right now, an Amana 2 stage furnace w variable speed blower AMVC960804C and a inverter driven Heat Pump, Amana AVZC200481, with two Honeywell TH6320WF2003 ( a T6 Pro model; I have a 2 zone system) with a New Zone First zone board. The thermostats are wired to what the Honeywell Tstat manual terms a 1H/1C System w 1 transformer for a "conventional" system. This is the most basic wiring in the manual. In the manual are another set of wiring diagrams for "Heat Pump" systems. Am I missing something? Shouldn't my themostat be wired for a Heat Pump System, possibly a 2H/2C or 3H/2C? If left the way it is, is the furnace going to be able to have the two stages act independently? And is the Heat Pump going to act as variable speed or will it act as just a single speed? Which configuration should it be wired for? Given that furnace is 2 stage, seems like 2H should be applicable, or should it be 3H since there is also the Heat Pump? Given that the Heat Pump is inverter driven what #C should be the configuration? If it's left as 1, will it only behave like a single speed? I've pointed out the wiring diag in the manual to the tech who is wrapping up the HPump install now and expressed my concerns. He doesn't seem familiar with this thermostat and is going to defer to someone else later as we go over Tstat operation. I'm not too hopeful that there is going to be a acceptable explanation, but am keeping an open mind, or trying to. Thanks for any input.
@thebrownanswer
@thebrownanswer Жыл бұрын
4:24 in my old thermostat, I have a wire jumper from u1 to r and a staple jumper from r to rc . The main red line coming from wall goes into rc . Do I need to keep these jumpers or will the t9 take care of it automatically? I have a fresh air intake (I believe that is u1) thanks
@johnclampettjr196
@johnclampettjr196 Жыл бұрын
Any idea why my fan won't turn on unless I do it manually? Auto function won't work. Great video by the way!
@naughtyely18
@naughtyely18 Жыл бұрын
Hello! They recently installed a new AC Rheem both inside/out units with a T1 Pro Thermostat (TH1110D2009) , however the AC runs for only about 6 minutes then turns off. It then takes close to 1 hour before running another 6 minutes… I saw another video about adjusting the cycle rate on the thermostat… Please let me know if this will fix my issue and how can I do it on this new thermostat. Thanks!
@saulzain1957
@saulzain1957 Жыл бұрын
I have a Goodman 5tn, 2 stage heatpump package for my house. Everything is in the unit that is outside except of course the thermostat. I have a Honeywell Pro Series model number TH6220WF2006 thermostat. The outside unit also has a 15kw heatstrip. Do you have any videos showing how to wire this unit specifically?
@barrywebb
@barrywebb Жыл бұрын
Great video but it still left me questions. I have a Honeywell T6 Pro with the external temperature sensor which supports dual fuel. I have a single stage heat pump and gas boiler. So I configured the temperature change (turn off the heat pump, turn on the boiler) to 40 deg F. It seems obvious that I setup for dual power supplies (Rh and Rc) and control the boiler via the W (heat) wire. But what happens to Aux/E? Are they in effect disabled? Or is the thermostat smart enough to know that when the temperature difference is above a couple of degrees that it needs to call for heat via the W wire?
@acservicetechchannel
@acservicetechchannel Жыл бұрын
You can look up the model thermostat and verify that it is in fact for dual fuel and the settings will allow you to set this up. There should be a differential that you can set. We usually set this for 10-15 degrees or so because we don't want it shifting back and forth.
@litedesign82
@litedesign82 Жыл бұрын
@@acservicetechchannel The differential setting is called "Droop," and it's available on the T6 thermostat, but not the T5. I've read in different places that the Droop threshold will trigger the aux heat anytime the indoor temp is lower than the programmed temp by the determined number of degrees, but I've also read that it will only trigger if it drops below the threshold *after a heating call* from the thermostat, while the heat pump is supposed to be running. I'm not sure which is true.
@tmurrayis
@tmurrayis 6 ай бұрын
The W2 wire was not explained. I understand it is for second stage heat on a 2 stage furnace. My question is how/when does the stat call the stage 2 heat? Does it look for a temperature differential (room is at 16C and the stat is set for 20C and recovering from a temp set-back overnight) or does it monitor the time taken to get to the set temp and fires the furnace's stage 2 after a set amount of time?
@badjiearaya8383
@badjiearaya8383 Жыл бұрын
Is the 12 ftlb torque for the 3 bolts on top enough? It seems a little too loose considering its for the front strut/shock
@Tman2010001
@Tman2010001 4 ай бұрын
The U terminal we see there, that can also be used for a connected dehumidifier right? Say for example, if a client had a heat pump system setup that also included a Santa Fe Compact70 (formerly Ultra Aire 70H) dehumidifier inside the mechanical closet with the air handler, how then would we go about wiring it up to the thermostat?
@andrewwest4470
@andrewwest4470 Жыл бұрын
Hi. My aux and e have a jumper in between them. Do I need to set this new thermostat up the same way?
@7Engineering
@7Engineering Жыл бұрын
Sir, please explain about checking the refrigerator inverter compressor, sometimes it is difficult to distinguish the damage between the PCB and the refrigerator inverter compressor
@acservicetechchannel
@acservicetechchannel Жыл бұрын
You can always ohm out the inverter compressor, thanks and we will have a new minisplit book coming out soon at the end of the year that discusses that, thanks!
@Heinrich99
@Heinrich99 Жыл бұрын
Just bought one of these Honeywell home t3 thermostats, I have a 4-wire electrical AC heater in my home, seems pretty basic, I hooked up yellow to Y green to G red to R and white to W Gray. Turn on the unit blows hot air. So I switched the white wire to W2 aux still blows hot air. What am I doing wrong.
@evamccurdy6306
@evamccurdy6306 Жыл бұрын
on my old thermostat I had a wire in the W2 slot where do I put it? I have a regular air condition and heating combination furnace?
@idsullymichaels
@idsullymichaels Жыл бұрын
I have a Honeywell Pro series. Looks like I can just pull it out and plug the T5 in that wire-set.
@ktop4u
@ktop4u Ай бұрын
I did the same but for some reason it runs heat only
@Anon-Amos
@Anon-Amos 4 ай бұрын
I know it's been a long time since posting, but I have a heat pump. Got everything hooked up fine, but my aux heat and emergency heat are the same. I previously had the TH3210 thermos and they were jumped together. I just hooked up the aux, because there isn't enough room for 2 wires in there, do I need to change that?
@callmeic
@callmeic 4 ай бұрын
If i have a honeywell r7284 connected to this controller with a 2 wire configure to an oil furnace, can i run a third wire to the G on the thermostat to somewhere on the envirocom to allow me to run the fan separately from the furnace so i can recirculate the air?
@hollihaddix4491
@hollihaddix4491 10 ай бұрын
My old thermostat had a jumper wire in the RC and RH terminals. I don't know where to put it in my new thermostat.
@wallacegray7681
@wallacegray7681 Жыл бұрын
Excellent instruction. I have a Amana 2 stage 3/1/2 ton heat pump 1 1/2 years old with a T6 Pro thermostat. I have had the thermostat replaced once because it did not turn off the unit when set temp was met. The unit normally got out of Recovery stage within 30-40 minutes going from cool 77 to 74 at night. Even though the set temp was met the unit runs for hours? The replacement is also a T6 Pro which I have noticed is NOT cutting off unit at night and runs for hours. AC company says is normal! I know it is not but should cut off within 3-5 minutes after set temp is met. The wiring is correct at thermostat (not opening outside unit). I have purchased a T5 Smart thermostat to replace the T6 but feel it is a unit problem so a waste of money. Can you address this issue for me? Thanks
@deanesmith7055
@deanesmith7055 5 ай бұрын
I am having the same issue with my Honeywell T6 not turning off when setpoint is met in heating mode. Runs constantly
@CarlitosG1711
@CarlitosG1711 Жыл бұрын
I've got a electric furnace home, the furnace fan constantly runs whether it's on auto or on. I don't believe I have an outdoor sensor but I have a black and brown wire going into both terminals could this be causing my fan to always run?
@tomt5609
@tomt5609 Жыл бұрын
Hello AC Service Tech LLC, I need some help please. My old thermostat had the red wire in the RC slot but the RC slot had a wire that was connected to RH which I am guessing that would be my jumper. My question is, on my new T3 where would that red wire go? to the R? or to the RC? Thank you in advance
@williamlobur6181
@williamlobur6181 5 ай бұрын
which terminals for only HEAT
@brucefrank6119
@brucefrank6119 4 ай бұрын
The T2 is supposed to work for 750mV heating systems. The thermocouple is the only power source. What are the connections for this two wire system?
@TonyHolmes-bd6sp
@TonyHolmes-bd6sp Жыл бұрын
I recently had my furnace replaced and my thermostat was replaced with the Honeywell T4. Now my compressor (AC Unit) will not stop running even when the thermostat is off. I have to turn off the power to the AC Unit from the power box. The wiring to the thermostat is all correct as stated in your video. I need help can you tell me what may be the problem. Now the company wants me to pay a thousand dollars for them to run more thermostat wire because my wire is bad they say. I don't it is the wire. Can you help?
@jonleone777
@jonleone777 7 күн бұрын
I have the t6 and was having issuss. The system has been working fine but lately when the target temp is reached the ac wont turn off. Air is cold, no freeze ups, condensate line flowing. Figured the thermostat may be bad. Not sure if it matters but i removed the thermostat to check gor any loose wires and jusy happen to notice there is not a wire in the common terminal. Apparenlty never has been. What kjnd of isdud might that cause
@dragalialost7345
@dragalialost7345 Жыл бұрын
Hi please help i have heating and air condition HVAC 5 wires red,green,black,white,orange. do i need to switch up the little switch? also the orange wire can i put it on Y socket?
@jasenzhao6793
@jasenzhao6793 Жыл бұрын
Hi, I have the old Honeywell control, my white wire is connecting to the port "E" in the old board, but I didn't find the E in the Amazon thermostat, could you tell me which port in the Amazon control I should connect? Many thanks.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Not sure what you mean by amazon thermostat, that could be anything. If it doesnt have an E function then you dont have an emergency heat function in that thermostat, thanks!
@litedesign82
@litedesign82 Жыл бұрын
So in this diagram, you have separate and Aux and E wires tied together at the furnace, so essentially they're jumped together and they do the same thing. In my setup, I have a heat pump on a T5 Wifi thermostat with an R and W back to TT on a gas boiler for backup. I've tried terminating the boiler W wire at E and at AUX, but as far as I can tell, there's no difference. Both terminals activate when the thermostat is calling for more than 2-3º of extra heat, and both activate when I turn on Emergency Heat manually. What gives? I guess I need a call to Honeywell.
@rock8034
@rock8034 5 ай бұрын
For a radiant building pipe system with 3 wires, where should the terminals go R, O/B and W?
@jamielegaultful
@jamielegaultful 8 ай бұрын
If I have a R and a RC wire can I use one (the RC) in the C spot and run a jumper from R to RC? I want to install a wifi thermostat without a C wire. I am installing a T-6 pro Honeywell. I have a R, RC, W, Y, G, wires. i have used a jumper from Y to G and and put the G into the C port. The heat side works great, the cooling side turns on but does not blow air at all. Any suggestions?
@fresheddie..
@fresheddie.. Жыл бұрын
I only got 2 wires ones is black n the other is blame one ? For heat only that good or no?...
@omarfattah3729
@omarfattah3729 11 ай бұрын
If i have a t-5 programmable tstat. Wired up the way it supposed to be for a heat pump and i didn’t put any batteries in cause i have a common wire. I have 28v on red but when i plug the thermostat in it does not power up. Is this a bad thermostat
@RocketMan200
@RocketMan200 16 күн бұрын
I was given a T6 pro brand new and want to install it, but I'm confused about where to put the wires from my current thermostat. So, my current thermostat wiring is set up as follows. White wire - W Blue wire - Y Green wire - G Red wire - Rc Then, there is a jumper from RC terminal to RH terminal. I'm not sure where to put the red wire on the new T6 which also has the jumper wire. Any help would be great. Thanks.
@Dooguy
@Dooguy 6 ай бұрын
I have a two stage radiant tube heater with only 3 wires coming out for therm. Just bought a Honeywell rth6360 therm. Which is digital.......... with my 3 wires coming from my heat box ...can i run both stages of heat with this therm. And not use batteries? My instructions on my heater say i need a 24v thermostat. Im lost
@Robert-1948
@Robert-1948 Жыл бұрын
Is there any video to connect my android phone and operate the temperature from my phone?
@renecuevas4128
@renecuevas4128 Жыл бұрын
The numbers are too small for our Senior Comunity Pls advice on bigger diaplay as a Pro 7 tstat
@specialranger8013
@specialranger8013 9 ай бұрын
I am currently having issues RTH6360 it goes straight to heat mode it isnt activating the reverse valve selenoid even with O/B wire in the O/B slot i am completely preplexed
@mantolaman
@mantolaman Жыл бұрын
I'm trying to use a heat pump with no auxilliary strips and a boiler for 'emergency heat' when it gets below 35°, but can't get this t-stat to switch to boiler without the indoor fan continuing to run on the heat pump?
@litedesign82
@litedesign82 Жыл бұрын
I had this problem too. After several lengthy calls with Honeywell tech support, I discovered most Honeywell thermostats are not capable of handling that setup. The T6 Pro (non-work) shown here is the only one. In Installer Setup (ISU) there are a couple of settings # 270 and 270 that control whether the thermostat runs the fan in Aux and Emergency heat mode. All other Honeywell thermostats assume you’re using a furnace as backup and always run the fan. I really like the Honeywell’s for everything else, so I’m probably going to just going to add a separate thermostat for the boiler.
@mantolaman
@mantolaman Жыл бұрын
@@litedesign82 My installer located an external circuit board from Jackson Controls, and managed to get it working as it should. I don't remember offhand what the model number of it it.
@HeavyBeam
@HeavyBeam Жыл бұрын
A lot of the calls I go to with Honeywell thermostats, anyone that installed it have that Rc switch down.
@gaoutdoor4372
@gaoutdoor4372 Жыл бұрын
What is going to happen if Rc switch down?
@AndyPlov
@AndyPlov 3 ай бұрын
I have the same thermostat, and for some reason the fan-on mode does not work. Even though the fan works normally in heating mode.
@mehowshorts
@mehowshorts Ай бұрын
Hello there, I have this thermostat and i have a question, i got new furnace, when i turn a A/C on, the fun turns on not A/C, is it bad condition in furnace??
@williamlobur6181
@williamlobur6181 5 ай бұрын
can i email you a picture of my old wired thermostat and find out where those wires go on the T4 ?
@chriskopec1858
@chriskopec1858 Жыл бұрын
❤👍
@4homemail
@4homemail 5 ай бұрын
What is the W2 is for? Mine is Honeywell and it has a wire to the W2. Thanks
@sandragarcia9205
@sandragarcia9205 6 ай бұрын
All of the wires are connected and my system is not turning on. Do you know what can be wrong? It was working and they were going to install the google thermostat but we decided to keep the Honeywell. After the reinstallation of the Honeywell the ac/heat is not turning on.
@aaronnunez292
@aaronnunez292 Жыл бұрын
How I now whish thermostat I need for my HVAC ?????
@terriwalheim8962
@terriwalheim8962 9 күн бұрын
Hello , My air conditioner guy , removed the back of my thermostat. and said this is the problem , and changed it to heat pump . Our electric bill has tripled !!! I took the back off and see a HP switch . is this what he changed and may I switch it , Thank you T
@dissociativecat7495
@dissociativecat7495 Жыл бұрын
so what about a two stage gas valve, w2 second stage ?
@ManleyCates
@ManleyCates 9 ай бұрын
Can this work on a 240 volt system
@renecuevas4128
@renecuevas4128 Жыл бұрын
If there s a short the Tstat will be shorted also Due to Red and Common wired to this Tstat control. Trust me
@kc6442
@kc6442 Жыл бұрын
Hello I'm new to your channel. Just switched from honeywell thermostat to Amazon smart thermostat. I have six wires. I believe we have central cooling with a heat pump. We have upstairs and downstairs. Upstairs has 5 wires. Outside we have two ac units it looks like one has copper coils inside. Problem is, when I put the ac on, it blows warm air and it doesn't feel cool. I hooked the wires up like this. R G Y O/B C What am I doing wrong??? Upstairs thermostat works well on heat and ac. I'm completely lost. Please help if you can. Great video btw 👌 downstairs with 6 (only 5 are connected. ) wires is having the issue. On the honeywell thermostat before, had the R wire, jumped into the RC slot I guess. Man I don't know. Thank you for your time God bless.
@robertjameson1959
@robertjameson1959 Жыл бұрын
I’ve installed a very large amount of t4 and t6 (lyric and regular) thermostats and have maybe replaced 3 that were still under warranty. Unless you’re getting the Home Depot t series or wiring them/programming them wrong, I don’t understand peoples issues.
@tycobb8621
@tycobb8621 Жыл бұрын
Seems like the T6 with a heat pump always gives me issues 🤷🏼‍♂️
@robertjameson1959
@robertjameson1959 Жыл бұрын
@@tycobb8621 no kidding? Maybe I’ve lucked out and haven’t had to put them in on heat pump systems. I’ll keep my eyes peeled.
@tycobb8621
@tycobb8621 Жыл бұрын
@@robertjameson1959 the older T6s had issues bringing on back up heat if it was a gas furnace and not heat strips. You could sometimes fix it by removing W on the heat pump but then you would lose your Aux heat during defrost.
@wallacegray7681
@wallacegray7681 Жыл бұрын
@@tycobb8621 I have a Amana 3 1/2 ton 2 stage heat pump with a T6 Pro which I replaced once and getting ready to replace the replacement T6 Pro again because it will not cut off unit once set temp is met, runs for hours so I chance temp and put on Permanent Hold! Now I will try thyT5 Smart thermostat!
@HeavyBeam
@HeavyBeam Жыл бұрын
Honeywell thermostats are probably the most versatile thermostat I’ve used.
@UltraHydrophobiccoat
@UltraHydrophobiccoat Жыл бұрын
Most people don’t use such many functions. Just like you pay higher price for something that you never use. It’s kind of waste money
@jagboy69
@jagboy69 Жыл бұрын
Could there possibly be a cheaper honeywell thermostat? At least give your customers the 1006 or the 6580 wifi. Don't install bottom of the barrel junk and NEVER install the stupid batteries! When the thing is blank, half my trouble shooting is done when I show up!
@deltasquared7777
@deltasquared7777 Ай бұрын
You are not quite clear on how the Y2 is connected and how it functions,; could you please explain/clarify? Thanks !
How To Fix A Missing C Wire | Nest Thermostat Troubleshooting
10:12
Everyday Home Repairs
Рет қаралды 686 М.
Пробую самое сладкое вещество во Вселенной
00:41
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 6 МЛН
WHY CAPACITORS FAIL in Air Conditioners! Watch it Break!
9:45
AC Service Tech LLC
Рет қаралды 1,3 МЛН
Why is Everyone Talking about Heat Pumps?
9:15
JerryRigEverything
Рет қаралды 512 М.
Thermostat Wiring
7:13
David Jones
Рет қаралды 2 МЛН
HOW TO BYPASS ANY COOLING/HEATING THERMOSTAT  HACK
9:45
D2D NY Real World HVAC Simplified
Рет қаралды 88 М.
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
The DIY HVAC Guy
Рет қаралды 190 М.
How does your AIR CONDITIONER work?
7:43
Lesics
Рет қаралды 7 МЛН