How to Add a Receptacle to a Lighting Circuit

  Рет қаралды 332,147

Sparky Channel

Sparky Channel

Күн бұрын

Пікірлер
@JChamberlin
@JChamberlin 4 жыл бұрын
These are the types of videos that I always enjoyed on the old channel. It's how I found the channel in fact. A good 'how-to' video is hard to beat. Have a great Fourth of July, Bill.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Hi Jim! I hope you guys are well and have a great 4th!
@ramonruiz2521
@ramonruiz2521 3 жыл бұрын
O
@rogerdevero8726
@rogerdevero8726 Жыл бұрын
You're a gifted teacher Bill. Your videos are clear, well presented and well filmed. Kudos - John 14:6
@josephguzman6019
@josephguzman6019 2 жыл бұрын
I enjoy watching your video everything you explain was clear and I was able to hook up the connection at home I'm at 78-year-old and let me tell you this was very groovy explanation thanks
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Groovy! I'm not that far behind you. LOL!
@jtrom
@jtrom Жыл бұрын
Thank you. You are a great instructor and the type of teacher I always appreciate. I'm somewhat lacking in the wiring/electrical department and trying to increase my knowledge and understanding so I can do more around the house. I will be checking your other videos for sure.
@SparkyChannel
@SparkyChannel Жыл бұрын
Thanks! You can do it!
@align450sport
@align450sport 3 жыл бұрын
By far the best electrical how-to video channel ever.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks so much James! Sparky Channel has by far the best viewers ever!
@cessna89811
@cessna89811 2 жыл бұрын
Thanks for this great video! I changed out a switch and my outlets quit working. After watching this I saw how easy it was to fix my dumb mistake!
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Excellent!
@screwdriver9955
@screwdriver9955 3 жыл бұрын
Excellent. Clear, concise and informative. Just the video I needed. Thank you! 👍
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure, thanks!
@terridumas
@terridumas Жыл бұрын
Thank you so much. I have watched several other videos and yours is by far the best yet.
@SparkyChannel
@SparkyChannel Жыл бұрын
Thanks Terri!
@johng30
@johng30 3 жыл бұрын
Your videos and instruction are the best on you tube
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks so much John!
@davidgiesfeldt6650
@davidgiesfeldt6650 2 жыл бұрын
Thanks for all of your great tutorials. With changes to the NEC 2020, you will need a neutral for the switch location… a 4 way WAGO would remove the need to later change it IF a device is added
@JustOneRedSoloCup
@JustOneRedSoloCup 4 жыл бұрын
Happy Fourth to the Sparky Channel! Bill, I'm sure it's just second nature to you, but if there's anything that sets the pros apart from others in the world of electricians, it's the attention to detail. You, sir, are a true professional.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks so much! I'll try to live up to your kind words! Have a great 4th!!!
@ricardovarajr
@ricardovarajr 3 жыл бұрын
First year apprentice for local 11 Los Angeles. Putting new Mc 12/2 in my garage. Ran into this exact problem today needing to wire 5 outlets to 2 lights that are controlled by 1 switch. Thank you for this!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure, thanks!
@MrWzeljunior
@MrWzeljunior 3 жыл бұрын
How long did it take you to get in local 11? I'm also in LA and I'm waiting for a call.
@Kuya_Raf143
@Kuya_Raf143 3 жыл бұрын
Bill the sparky channel you have a superb skills with regards in electrical wiring, lot of lessons i learned everytime i watch your video Kudos 😊
@DRstayhard2
@DRstayhard2 Жыл бұрын
I love your work and you make it so simple and you're very thorough. But tell me this, why are you always using metal boxes and is it just because of your area?
@patriciogonzalez4882
@patriciogonzalez4882 4 жыл бұрын
Well done, lesson learned.can't be explained Easier than that. i like those tools.please keep doing these videos. God Bless HAPPY NEW YEAR 2021 L.A. CALIF.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Patricio!
@idahahs
@idahahs 2 жыл бұрын
I felt like I was back in shop class with the one teacher who knew his stuff.
@evdure
@evdure 2 жыл бұрын
Excellent quality. Thank you. This video was very helpful.
@JtotheRizzo
@JtotheRizzo 6 ай бұрын
Would love to see a video tutorial where the power (hot wires) comes into the light fixture rather than the switch box. But thanks for this video!
@CarlosAugusto-li8dl
@CarlosAugusto-li8dl 3 жыл бұрын
Excellent educational video. Thanks a lot for sharing your experience. This is was my first time seeing the wago lever-nuts, those are great and very practical for an organized and space saving installation. Thanks a lot again sir.
@josedelacruz7279
@josedelacruz7279 4 жыл бұрын
Thank you for all your teaching help me a lot good blessed you
@SparkyChannel
@SparkyChannel 4 жыл бұрын
My pleasure, thanks Jose!
@joer9276
@joer9276 4 жыл бұрын
As always great video. Those WAGO connectors sure make this a lot easier. I bought enough to wire the house I’m building. Will make pig-tailing easier and quicker.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
I agree. Thanks Joe!
@sagebrushoutdoors5712
@sagebrushoutdoors5712 4 жыл бұрын
A lot of fireman claim to not like them.
@surferdude642
@surferdude642 3 жыл бұрын
@@sagebrushoutdoors5712 I don't know about firemen, but some older electricians hate them. It's hard to tell who is right though as most of the evidence for or against is anecdotal.
@paulcalhoun6339
@paulcalhoun6339 4 жыл бұрын
Mr Sparky, your videos and instructions have given me the courage to wire my 12’x36’. So far so good. I am having trouble with a circuit that will control a light and outlet. This video situation is exactly what I want to do, but the light switch is located outside, about 15’ from the outlet. How can I wire to control the light and the outlet from the switch?
@SparkyChannel
@SparkyChannel 4 жыл бұрын
It would be like wiring multiple lights except you're wiring a light and an outlet, both which are controlled by a switch. Check this out, I think you'll get the idea: How to Wire Multiple Lights and How To Prepare Wiring for Drywall: kzbin.info/www/bejne/aGrakIajiriVlas
@kenmiller3073
@kenmiller3073 2 жыл бұрын
I have a question sir I love your videos...now why didn't you install the line wires going to the switch on the top terminals of outlet ? Usually the feed is on top and the load is on bottom.or maybe I can learn a different way.
@mitchellhofmann2981
@mitchellhofmann2981 4 жыл бұрын
Your passion makes me smile
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks so much!
@jimross2101
@jimross2101 4 жыл бұрын
Many lighting circuits are not 20 amp but typically 15 amp instead and therefore you will likely see a 14-2 with ground romex to a lighting fixture. Also, the romex from the switch junction box to an outlet box would then be a 14-2 with ground romex in your example.
@ebadss1
@ebadss1 3 жыл бұрын
First off thank you for your informative video thank you for the time to make this available for us, question if I wanted the receptacle to turn off and on with the switch how would that be wired,
@mandan5
@mandan5 4 жыл бұрын
Your videos rocky sparky, never stop.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks so much! have a great 4th!
@Mymusickb
@Mymusickb 2 жыл бұрын
Could you also replace the 12/2 from the switch box to the light fixture with 12/3. Use the red from switch o light. Use the black to carry the current through the light fixture to the outlet, using 12/2? Tying together the neutrals, and grounds of course. 😀
@SeanLarinzo
@SeanLarinzo 6 ай бұрын
I was thinking the same thing. What’s the difference in using the two when Adding a receptacle
@ddallas8540
@ddallas8540 3 жыл бұрын
Great video. I have a question. What if the hot wire is coming through the light fixture, how would you add the outlet then?
@Guardducks
@Guardducks 4 жыл бұрын
Excellent video. Understood every bit if what you were doing never got lost once. I was waiting to see if you would wrap your receptacle and switch and you did, because if you hadn't i was gonna get on you. Ha ha
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Hi! Thanks so much! Yes, I'm a device wrapper. LOL! Have a great Sunday!
@Yutnom2woof.
@Yutnom2woof. 3 жыл бұрын
Clear concise thank you now let me go do my connections
@joelnewsome597
@joelnewsome597 Жыл бұрын
Mr Sparky I'm glad I've found you again not knowing what or why you were off KZbin but there are a lots of evil people who would do any of us harm for selfish reasons but they have there reward in this life if you know what I mean but I appreciate your kindness in sharing your knowledge and skillets that has been a wonderful blessing to many of us and will be staying tune for future videos as you build again but as to the tools you mentioned after each video that one can get I personally can't find your link that you reference that I might use for locating and purchasing, please clarify, thanks?
@SparkyChannel
@SparkyChannel Жыл бұрын
Hi Joel! Yes, my whole channel got destroyed but I started a new one with the same name and it's doing well. All the various tool links should be in my video description below the video. Thanks!
@realtorserg3538
@realtorserg3538 3 жыл бұрын
Good quick explanation. Thank you for the video
@graphguy
@graphguy 2 жыл бұрын
How about discussion on how many of these could you daisy chain in a garage?
@jprovenzano87
@jprovenzano87 4 жыл бұрын
Right on, going to give this a try. Great informative video!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks!
@Matt-mh7yg
@Matt-mh7yg Жыл бұрын
Great video! I'd like to do something similar on a 15 amp circuit and use a switchbox to power other switchboxes on the same circuit. However, I'm confused (and stuck) by NEC 404.3 Enclosure, (B) Used as a Raceway, which states: Enclosures shall not be used as junction boxes, auxiliary gutters, or raceways for conductors feeding through or tapping off to other switches or overcurrent devices, unless the enclosure complies with 312.8. When I look at 312.8, it looks as if I can use enclosures meant for switches for feeding through, spliced, or tapping off to other enclosures, switches, or overcurrent devices as long as 1) The total of all conductors installed at any cross section of wiring space does not exceed 40 percent of the cross sectional area, 2) the total area of all conductors, splices and taps installed at any cross section of wiring space does not exceed 75 percent of the cross sectional area, 3) Bending space for conductors 4 AWG and larger complies with 314.28A2, and a warning label complying with 110.21B is applied to the enclosure. So with 312.8 in mind, will I be ok to use a switchbox to power another switchbox as long as I comply with 312.8 1, 2, 4 (3 does not apply)? Thank you so much for the help!
@jonnyz5758
@jonnyz5758 4 жыл бұрын
Very detailed and informative video, thanks for sharing!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure, thanks!
@brokenj75
@brokenj75 3 жыл бұрын
Need to do a video on archfault breakers and troubleshooting .
@raulanthony3958
@raulanthony3958 4 жыл бұрын
sir your video r very helpful and u have made it super easy for wiring understanding i am so glad i found your video please keep up the good work
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure, thanks!
@billhandymanbill2775
@billhandymanbill2775 3 жыл бұрын
Nice and clear video. But through video editing at 8:18, you didn’t show adding the third black wire to the Wago connector that goes to power the switch as it magically appeared a few seconds in the video. Also, I would extend the electrical tape around the switch as some of the copper was visible on the switch which cause a short if it touches a ground in the box.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks!
@chriscandies7371
@chriscandies7371 2 жыл бұрын
Thank you for sharing your knowledge. Much respect. Good teacher.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Thanks so much!
@johncockerham7410
@johncockerham7410 2 жыл бұрын
I have looked and looked for this explanation Thank you!
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Glad it was helpful! Thanks John!
@johnnytenorio3943
@johnnytenorio3943 3 жыл бұрын
This was very informative! I am trying to do the same concept but from a 3 switch. Would you be able to demonstrate how this would be done? So adding a always hot receptacle from a 3 switch light. Hope that makes sense. Thank you.
@rayzorman46
@rayzorman46 3 жыл бұрын
VERY clear instructions. Thank you very much!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
My pleasure, thanks!
@r3alfish
@r3alfish 3 жыл бұрын
What if I have a light that I need to come off of for an outlet but it's wired with loop wiring where I get power to my fixture first instead of the switch first? I know I could tap into the hot wire but what would I do for the neutral?
@mikeryan6277
@mikeryan6277 3 жыл бұрын
Good video just an observation, I realize service panel is right behind you but you should have still mentioned LOTO most DIYer’s don’t even know about it. Ground conductor should be last one off and first one on ( it’s the one that will protect you because you didn’t use LOTO lol ) we point all connectors up so moisture can’t collect inside and corrode. Last all screws should be vertical ( just a trade thing )
@clavelarmandojesus4048
@clavelarmandojesus4048 3 жыл бұрын
Definitely so helpful! Thanks for your time to do this . Question ... is that ok adding a neutral pigtail on my switch too ?
@DerekDavis-ce6jq
@DerekDavis-ce6jq 3 жыл бұрын
Awesome presentation, Sparky...!!! Thank you
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Very welcome. Thanks Derek!
@danielcastillo-jarillo1261
@danielcastillo-jarillo1261 4 жыл бұрын
Sparky busted deveria de dar unas classes, despues de unos toques hace años no queria saver made de electricidad pero usted lo esplica muy entendible 👍
@yag3905
@yag3905 3 жыл бұрын
Why would someone dislike sparky...people are messed up
@SparkyChannel
@SparkyChannel 3 жыл бұрын
LOL! Thanks!
@mrob5278
@mrob5278 4 жыл бұрын
Great video!! Thanks for the help. You don't happen to have any videos on how to wire up an outdoor spotlight would you?? Thanks again!
@camericasoon
@camericasoon 2 жыл бұрын
Thanks for insights. I have a two 3 way switches and I want to add receptacles to each box. It’s appears I won’t have a “white” wire for the 2nd receptacle. What to do?
@firstdown80
@firstdown80 2 жыл бұрын
Thank you. Been searching to wire my attic lights and outlet. Currently the outlet is live only when the light switch is on.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Good luck!
@truthh8322
@truthh8322 3 жыл бұрын
Depends on where you are on the permit. Some counties don't require it
@ZunarZulfiqar
@ZunarZulfiqar 4 жыл бұрын
I was wondering, if you have a sinagle duplex outlet, do you need a permit to make it a double duplex outlet? Doesn't adding a power strip do the same thing as far as overloading a circuit due to added receptacles to the original circuit? I didn't know I needed a permit to do that when I changed several single duplex to double duplex outlets. I do know what I was doing and even took the liberty of finding the first outlet in the circuit and making it a GFCI.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
That's a good question but I think that would just be a replacement and wouldn't require a permit. You could always give a call to your local inspector and ask though.
@sushi13141
@sushi13141 2 жыл бұрын
This is how I did my bathroom. GFCI outlet.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Sounds good!
@carloslagunas859
@carloslagunas859 3 жыл бұрын
Mr Sparky hope you doing good, I have a question for you, can I get power from a receptacle to a light switch and use a double light switch, 1 for exhaust fan and other for a light?
@xxZOMBIEx
@xxZOMBIEx 2 жыл бұрын
I got a problem. I was replacing(not installing) a GFCI outlet and a 2 single pole switch that was in the same electrical box. Only reason was the switch that controls the overhead bathroom fan broke and was stuck ON. I bought a new gfci outlet and 2 single pole switch to replace them. I figured I just put the wires where they were on old pieces. The original had white neutral wire going to the LOAD and red wire going from hot side of Load to the hot side of switch. I couldn't get the switch out far enough to just un screw and put on the new switch. So I had to get all the black wires off. That's where my issue started. I have 4 black wires. None were going to the outlet only the red. My tester showed one black wire going down the box was hot. I can't remember where all 4 blacks were going. There were only 4 screws used on switch. No ground. Only ground was on the outlet.
@michaelleone1957
@michaelleone1957 3 жыл бұрын
Great and simple. Thank you.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
You're welcome and thanks!
@LuisSanchez-wf9zw
@LuisSanchez-wf9zw Жыл бұрын
@sparkychannel What do you do with metal boxes where the house doesn’t have a bonding system because the house hasn’t been updated (with ground wires and only has black and white wires) since the late 50s? My new bathroom vent says I must connect the unit to the ground of the house but this dedicated circuit doesn’t have one even though the 20amp/12 ga was powering / used for a ceiling mounted heater.
@E5826T
@E5826T 3 жыл бұрын
Hell sir. Thank you for the video. Can you tell me how you’d run a new circuit from the panel in my unfinished basement that goes to an outdoor grill island. It’s a 75’ run total and I’m installing 3 outlets in the island. I’m considering running NM from the panel to a metal junction box near the point it exits the house, transition to THWN individual conductors that run outside in PVC conduit to the island.
@Eddy63
@Eddy63 4 жыл бұрын
Good 1 Wild Bill ... Love those how to vids ...
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks Eddy! Have a great 4th!
@maxmcbyte
@maxmcbyte 3 жыл бұрын
Hi Sparky, Use to know a fellow who went by the name of Sparky Marine in Sausalito, Ca that provides services to folks with yachts. He helped me install a radar system on a 47-foot Gulfstar motor sailer, was that you? Anyway, I followed your excellent instructional video and it all worked! I was able to plug in a lamp for testing and I could turn it on or off, independent of the light switch position. The problem is that it did not work for my particular setup. Let me explain. Just for clarity, I have a ceiling light in my hallway that has a Lutron dimmer switch and I want to have an outlet to plug in a Vornado heater. Note, I am temporarily using an extension cord that has 3 wires for proof of concept before I get the proper outlet as you are using, perhaps this is the problem. Am not sure what the correct terminology is but my old school terminology would say that the power cord (that I cut off the plug) has a ribbed (positive) conductor, a negative conductor (not ribbed), and a ground. After I followed your instructions, it all worked using a lamp plugged into the outlet for test purposes. I thought, great! Now that it is working, I will go and get a proper outlet. THE PROBLEM Even though the test lamp worked as expected, when I plugged in the Vornado heater and then turned it on, the ceiling light in the hallway would come on, not what I wanted nor expected as the test lamp did not behave this way, and the Vornado heater, even though it was on did not put out any heat nor was the fan turning. Note, my Lutron dimmer switch has 3 screws, 3 terminals, one black, one gold, and one blue, not sure what the blue is used for. The Vornado heater has 3 settings, 750 watts, 1100 watts, and 1500 watts. It requires 12.5 amps at the max setting of 1500 watts. Obviously, I am doing something wrong. If you can help guide me, I'll buy you dinner or a couple of cases of beer! Thank You! MaxMcByte...
@chilson88
@chilson88 3 жыл бұрын
Awesome video and very informative. I can listen and watch your videos all day. New sub for you
@JPO1184
@JPO1184 2 ай бұрын
I have a question. I installed a GFCI outlet, jumping off of a light switch following this same configuration. My Klein GFCI outlet checker says everything is good. I later bought a circuit breaker finder tool and was trying it in different applications. When testing it on this circuit, I discovered it fails to work on both the GFCI outlet and the light socket (using an adapter), but does work if I open the light switch panel and connect the transmitter to the hot and ground wires with jumper clips. Could you please help me understand why it doesn't work on the outlet and light fixture on this circuit, but does work when connected to the switch wiring? Thanks. It works great on other light fixtures and outlets that aren't sharing a circuit.
@keithkeithkeith9874
@keithkeithkeith9874 2 жыл бұрын
Can 15amp lights be wired on a 12 guage circuit? Trying to avoid using 14 guage.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Yes, that's not a problem. You can exceed code if you like.
@toddwyndham7009
@toddwyndham7009 2 жыл бұрын
I’ve got a question I’ve got A12/2 Wire running to a 20 switch that I’m using as a disconnect in my shed right next to the switch same 4x4 metal box is an outlet coming off the outlet ran a wire to a another light switch by the door then another cable 14/2 going to the light receptacle for the shed my question is can I go from the light receptacle on the ceiling center of shed with another wire and put another plug-in other side of the shed?
@toddwyndham7009
@toddwyndham7009 2 жыл бұрын
Or do I need to run another separate wire all the way back to the main 12.2 power wire coming into the shed ?
@sapreaper
@sapreaper 2 жыл бұрын
Technically you can pigtail a hot from anywhere to power more lights or a receptacle. But a white/neutral is needed for a receptacle.
@sapreaper
@sapreaper Жыл бұрын
Fyi i cannot tell, but that 14/2 wire needs to be supplied by a 15 amp cb. NOT a 20a
@jpalumbo98
@jpalumbo98 3 жыл бұрын
Hi thanks for your help. If your installing say two light fixtures to this setup would you use the 12/2 wire to connect the two lights or 14/2 ?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
I would, yes.
@gilshar316
@gilshar316 3 жыл бұрын
Thanks just what I was looking for
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Excellent!
@garydudgeon
@garydudgeon 4 жыл бұрын
Great video Sparky.
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Happy 4th to you and Family!!! Have a great day and thanks!
@rickeykeeton4770
@rickeykeeton4770 3 жыл бұрын
That is a circuit feeding the switch first. What if the light is being fed first and the switch is at the end of the circuit? Wire the outlet past the switch and just have it where the outlet AND the light are controlled by the switch? Or, can the outlet be fed first then the switch and the outlet remains live regardless if the switch position?
@justinmaloney910
@justinmaloney910 Жыл бұрын
How would I do the same setup but make the outlet a switched outlet?
@kyleberndt8315
@kyleberndt8315 Жыл бұрын
Switched outlet is set up the exact same as a light-- you treat the outlet receptical the same as the light receptical. So you'd be going directly from hard wire
@paulflorida8640
@paulflorida8640 4 ай бұрын
I have a lamppost that I installed, I added a receptacle to the bottom of the lamppost, the the box does not work only if the light switch is on, How can I have the box hot all the time and when the lamppost is off. I have a junction box tapped off from the light switch and wire leading to the lamppost? Paul
@gbpce7766
@gbpce7766 3 жыл бұрын
Good job sir. It was knowledgeable session. I wish you have more discussed about switch connection. I am bit confused that which side we should connect HOT and neutral on switch. Does it matter ? Like, on receptacles gold is for Hot and silver is for neutral. Likewise does switch has same terminology? Thanks
@Ryan-dj5ku
@Ryan-dj5ku 2 жыл бұрын
Single pole switches take two "hot" wires, they do not take a neutral. The neutral just passes through the box without connecting to the switch.
@TheOctane24
@TheOctane24 3 жыл бұрын
What would happen if you just put the ground from the 12/2 straight on the outlet?
@truthh8322
@truthh8322 3 жыл бұрын
Nothing. The grounding wire (stinger) To box just ensures proper grounding at all times. It will also ground itself when you screw it to the box. It's a precaution
@patrickarchuleta9594
@patrickarchuleta9594 2 жыл бұрын
Sparky question can u use the newerled lights on the 20 amp.
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Sure.
@tracykey9227
@tracykey9227 Жыл бұрын
You can even use more of them than the old light bulb types; just keep within the max circuit ampacity
@allenstautz9506
@allenstautz9506 2 жыл бұрын
Sparky, Help! Like your videos and tutorials, Thank you! But got a problem here for you...bath vanity lights, wth switch OFF, lights have a dim glow. Function great with switch on. 2 yrs ago, added a GFI outlet to sink area, and light switch above GFI. Lights powered through GFI outlet. But lights have dim glow when switch is OFF...What do I need to do. GFI tests ok.
@DejuanJohn
@DejuanJohn 3 жыл бұрын
What if you have a 12/3 in a junction on ceiling but want to connect 12/2 is it possible to cap off the red hot in order to do that? Or the 12/3 must go to a light then a switch then 12/2 to switch and 12/2 to outlet?
@Grayback1973
@Grayback1973 2 жыл бұрын
Hi, I want an existing switch to control an outlet instead of the fan light it controls now. I know that I would run a red wire from the switch "hot out" terminal to the outlets hot terminal but my question is this.....because it would just be a single wire could I just run it up the wall and through the 2x4's then down to the outlet? I don't want to run conduit or use a 2-wire Romex if I don't have to. Thanks for any input!
@tracykey9227
@tracykey9227 Жыл бұрын
Im pretty certain code does not allow a single wire run; you have to run a romex or conduit; the wires, even if using only one of them, have to be protected with an outer sheathing.
@jeffmcclure888
@jeffmcclure888 3 жыл бұрын
A permit to add a new receptacle? What state are you in?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
California.
@KenPryor
@KenPryor 4 жыл бұрын
Another great video! Thanks Bill!
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks Ken!
@MrMed-hl2fq
@MrMed-hl2fq 3 жыл бұрын
Could u answer a question: if the outlet and switch were in the same box would the wiring be different?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
I'll do a video on that. It will be a 3-way switch, not a regular switch but it should answer the question.
@MrMed-hl2fq
@MrMed-hl2fq 3 жыл бұрын
I only want the switch to control the light, the outlet is always hot for a Washing Machine.
@adamsharr9948
@adamsharr9948 3 жыл бұрын
@@MrMed-hl2fq to do that you pig tail a neutral and the constant hot to the receptacle. make sure it's the constant hot and not the hot going to the light.
@RR-ce9tu
@RR-ce9tu 3 жыл бұрын
How do i check if the yellow wire is 12/2.....i have a switch that controls the light of my backyard and a power outlet in my living rooms..so my problem is that if i turn off my backyard light my tv also turns off ...so i need to leave my backyard light on all day...how do i fix that? Please help me thank you so much
@daviddelacruz7158
@daviddelacruz7158 2 жыл бұрын
What if the line is in the light 4s box and you still want to add a receptacle from the switch single pole. Will everything be pig tailed?
@cc3968
@cc3968 4 жыл бұрын
Is this basically how you would wire to a new switch for a different light without the first existing switch turning it on and off as well?
@busterking5895
@busterking5895 2 ай бұрын
I am not going to town and get in line to get a permit for that
@alexandrekflores
@alexandrekflores 3 ай бұрын
Great video!! What if, in the same configuration, I need to create the receptacle from the light fixture?
@josianrodriguez1249
@josianrodriguez1249 3 жыл бұрын
SALUDOS SPARKY ANOTHER GREAT VIDEO. G.B.Y.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Josian!
@REdgar66
@REdgar66 3 жыл бұрын
I tried this and the outlet is only working when the light switch is on. I’m going crazy trying to figure out why.
@Lando1020
@Lando1020 3 жыл бұрын
Switch should have 2 black wires. 1 goes directly to your light. Other is a a small piece of black wire (pigtail) that connects to wago lever nut or wire nut of your choice along with black wire from outlet and black wire from power coming in.
@Lando1020
@Lando1020 3 жыл бұрын
Right around 8:31 you can see additional small piece of black wire aka pigtail
@omarguevara3
@omarguevara3 3 жыл бұрын
@@Lando1020 what if the lamp is on a wall far from the light switch.
@elliotlg6364
@elliotlg6364 4 жыл бұрын
Thank you Mr. I like
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Thanks Elliot!
@streetgainer
@streetgainer 3 жыл бұрын
Excellent tutorial. Thank you.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
You are welcome, thanks!
@Prekkersaurus
@Prekkersaurus 2 жыл бұрын
Thank you for teaching.
@jimeagle1952
@jimeagle1952 2 жыл бұрын
What's the cost difference between 12 and 14? Why not just go with 10 on a 30 amp giving the advantage of being able to put even more receptacles. What's difference in cost between 15amp and 20amp receptacles? What's the difference physically between a 15amp and 20amp receptacle?
@frankpizarro7924
@frankpizarro7924 2 жыл бұрын
don't use 14 gauge look up the American national electrical code
@frankpizarro7924
@frankpizarro7924 2 жыл бұрын
just saying
@sapreaper
@sapreaper 2 жыл бұрын
@@frankpizarro7924 just sayin' what exactly?
@miamited69
@miamited69 3 жыл бұрын
What if the power source is inside the finished wall in plastic box? How do you get the romex in the feed box and secure it?
@DrBilly90210
@DrBilly90210 3 жыл бұрын
When I ran into this, I figured my options were to use a wire snake (aka "fish tape") from the box in the finished wall to the new box you're installing OR remove the finished box, run the wires, and install what's called an "old work" box. My experience has been better using the "old work" box, especially if you have to drill through studs to route the romex, but YMMV. Not saying you should do what I do, just putting out my experiences.
@dangatewood9801
@dangatewood9801 3 жыл бұрын
Sparky can you wire two motion detectors together in the same circuit to operate one light? Ie: staircase
@jobaecker9752
@jobaecker9752 4 жыл бұрын
Hah! Pretty did a similar job in my garage last week - except I was adding a convenience light and a 2-gang box (light switch + always hot receptacle). My line wire was coming into the lighting fixture first. I thought I could run a 12-2 from the light fixture to the gang box, but after thinking it through, it was (of course) a 12-3 that I needed. I was second guessing myself for a few minutes there...
@SparkyChannel
@SparkyChannel 4 жыл бұрын
Electricians need to do lots of thinking. That's why we're so smart. LOL! Thanks Jo!
@yusuihang
@yusuihang 4 жыл бұрын
If you add a receptacle to a lighting circuit that uses knob and tube wiring, can you just add romex wiring to the circuit to add the receptacle, or does the NEC code require that the entire circuit be converted over to romex? In general, can you just add circuits to an existing knob and tube installation using romex for the additions, and just leave the existing knob and tube wiring in place? Thanks.
@brianbell2439
@brianbell2439 4 жыл бұрын
You can add romex to an existing knob and tube circuit, providing you are not overfilling the box you are tapping off of. If you're planning on taking power from a light switch, there will most likely be no neutral in that box. Older homes usually have the neutral at the light and have a dead end switch leg at the switch. If you do find a knob and tube junction box to tap off of, you will have to install a ground fault receptacle since here is no ground with knob and tube.
@yusuihang
@yusuihang 4 жыл бұрын
@@brianbell2439 Thanks! All your comments make sense.
@nareshjaviya5182
@nareshjaviya5182 4 жыл бұрын
Can I get receptacle off 3 way switch?
@444not
@444not 4 жыл бұрын
Very helpful. Thanks
@SparkyChannel
@SparkyChannel 4 жыл бұрын
You're welcome, thanks!
@Guzman_j
@Guzman_j 3 жыл бұрын
Thanks for this amazing tutorial I just subscribed
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Welcome to Sparky Channel!! 👍
Half Hot Receptacle with Power to Switch Installation
14:10
Sparky Channel
Рет қаралды 109 М.
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 156 МЛН
How To Fix a 3-Way Switch System
14:46
Sparky Channel
Рет қаралды 228 М.
How to add a Ceiling Light to a Room with no Existing Wiring
29:48
Workin' with Wolkon
Рет қаралды 1,3 МЛН
How To Add A New Light To An Existing Circuit | Basement, Attic, Or Crawlspace
11:08
How To Add An Outlet From A Light Switch | Common Mistake
12:54
How To Home
Рет қаралды 1,6 МЛН
How To Add An Outlet To A Finished Wall
10:51
Everyday Home Repairs
Рет қаралды 10 МЛН
How To EASILY Add An Outlet In Any Room Using A Light Switch!
17:30
How to Add a Light from an Outlet
9:30
HandyDadTV
Рет қаралды 1 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 156 МЛН