How to add refrigerant (R22)

  Рет қаралды 32,180

HVAC Tech Tips

HVAC Tech Tips

Күн бұрын

Charging with R22. Pressures, line temps, exc.

Пікірлер: 22
@amtrakusa1
@amtrakusa1 2 ай бұрын
Great pressure number presentation at different air temps. Thank ya!
@TylerDurden-zr4xv
@TylerDurden-zr4xv 3 жыл бұрын
Straight to the point!! No bullshit!! Thanks man you saved me some money!! Much appreciated!! 🇺🇸
@enushalu2548
@enushalu2548 3 жыл бұрын
Nice Video on R22 pressures & temperatures.
@Berni0707
@Berni0707 4 жыл бұрын
Best refrigerant you can ever find, efficient, less GWP than 404a and 410a and for some reason it was used for so long! Just 0.05 ODP! And they want to ban it...
@colorizedenhanced-silentmo9027
@colorizedenhanced-silentmo9027 4 жыл бұрын
Howdy, HVAC Tech Tips. fantastic video. thanks. :)
@HVACTechTips
@HVACTechTips 4 жыл бұрын
👋 Thanks Man! I appreciate it.
@jeffcarpenter396
@jeffcarpenter396 2 жыл бұрын
Great job
@bude8234
@bude8234 2 жыл бұрын
Have an old R22 unit that does not cool well. I believe it uses a piston as the metering device, but I can't see inside. On the outside unit it has "Piston no. 70" on the label. The suction side line near the outdoor unit never seems to sweat, or get cool. My low side pressure is 75 PSI, and my high side is 205 PSI on a 90 F day with high humidity. The liquid line pipe temp was about 92 F, and the suction side pipe temp was about 64 F. So, I calculate about 20 F of superheat (64 line temp - 44 sat temp on guage = 20), which is too high, right? (should be about 5 according to the charts). Indoor WB was about 60-62 F. Do I just need to add more refrigerant? Or is it normal that the suction line does not sweat? Thanks to anyone who can offer advice!!
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 жыл бұрын
What size system is this, I'm inclined to think the indoor piston could be a bit large based on those pressures. Maybe the air handler is moving more than 400CFM/Ton? Your compression ratio is 1.88, meaning the compressor is having an easy day. Typical compression ratio is 3~4. If the system was undercharged, the compression ratio would be much more, or too high. I bet you've got an indoor txv and need to concentrate on subcooling, which seems a bit low. And that superheat is high in that case. But make sure it's an indoor txv so you know for sure, got to know this.
@HienLe-qh6mo
@HienLe-qh6mo Ай бұрын
I have a 2.5 Ton Carrier (27 years old) with almost leak free system. You will lose some heat removal capacity from the air on days with high humidity. In your case, you can add some refrigerant to get the low side to 80 PSI and the high side 220 PSI to see the low side sweat. What is your Indoor DB temperatur?
@americanallergy
@americanallergy 2 жыл бұрын
Hi You sound like you know how to charge the ac system with SC and SH. FOR Topping off an AC system. For R22 3ton 10LBS system. Evap temp 40F - What percentage of freon (LBS) is lost when the suction line freezes @ 32F. And it it more % (LBS) for R410a because of a high evap temp 45F. Is it less than 3 LBS? Just try to figure customer costs for jan 2022.
@MrBadtboy
@MrBadtboy Жыл бұрын
What if the low pressure side is higher than high pressure side?
@staytight6340
@staytight6340 3 жыл бұрын
Weird Charged a r22 unit today the low side was at 70 which is good but the high side was at like a hundred. The air from the vent got 5 degrees cooler so I left it like that. 75 ambient temp Any reasons?
@HVACTechTips
@HVACTechTips 3 жыл бұрын
Sounds like you had a compressor problem or maybe txv/piston issue
@The1realro
@The1realro 6 ай бұрын
Had this same issue ! Thank you
@w8what575
@w8what575 2 жыл бұрын
Since my money isn’t good enough for the hvac guys where I’m located …I’ve rigged up a hose for a vehicle with adapters that will fit my central air unit and bought a can of r22 online..gonna attempt to charge it on the low side vapor instead of high side liquid…all this could have been done and paid for in full if the hvac guys in town weren’t so prone to violating peoples civil rights…sad what egos are doing to the profession…u tell someone u do hvac ur probably going to get shunned and treated like the dirt bags most are…u have a responsibility that comes with ur chosen line of expertise and when these guys pick and chose who they will do work for it’s bs! Especially when the customer NEEDS ac or they could die! There’s a medical condition that requires constant temp be at room temp or the blood thickens….so yeah! People can die without ac! And when someone can’t get ac because the hvac guys are too good to work on a home that’s in progress of being remodeled…it looks like crap but it’s a home! Get over it! The notes are the same as rich ass joe down the street! U get to chose whether I get to live or not? Nope!
@LubaLuba1
@LubaLuba1 2 ай бұрын
Question to any enthusiast If I added refrigerant to high side by accident what will happen?
@Geronimo1501st
@Geronimo1501st Ай бұрын
How much did you add? Also what are your current ac symptoms? If it was a little bit don't worry. Do you have a Txv or piston on your system?
@HienLe-qh6mo
@HienLe-qh6mo Ай бұрын
Nothing bad is going to happen actually to your AC unit. It would be much slower to charge if your bottle pressure is still higher than the high liquid line pressure.
@LubaLuba1
@LubaLuba1 Ай бұрын
@@HienLe-qh6mo I accidently bought these moisture remover cans to put in my system cost just as much as freon does this stuff really work?
@HienLe-qh6mo
@HienLe-qh6mo Ай бұрын
@@LubaLuba1 The moisture removal agent is used together with a leak sealant product. My 27 years old 2.5 Ton Carrier is still almost leak-free so I did not need yet to try them. I do not have an answer to your question.
@americanallergy
@americanallergy 2 жыл бұрын
This ac system is 30K btu 2.5 Tons R22 4.75# or 76 OZ SP 60# You added 13 OZ to raise the SP to 70# . R22 loss = 13 / 76 17% loss @ 60# PSIG R22 What would the % or LBS at 55#PSIG suction pressure.
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,8 МЛН
R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge!
7:41
Violet Beauregarde Doll🫐
00:58
PIRANKA
Рет қаралды 50 МЛН
Angry Sigma Dog 🤣🤣 Aayush #momson #memes #funny #comedy
00:16
ASquare Crew
Рет қаралды 48 МЛН
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
超凡蜘蛛
Рет қаралды 16 МЛН
Will A Guitar Boat Hold My Weight?
00:20
MrBeast
Рет қаралды 86 МЛН
How To Refill R22 AC With Subcooling Method
14:37
Word of Advice TV
Рет қаралды 374 М.
How To Add Refrigerant To Your Air Conditioner R410A & R22
10:15
The DIY HVAC Guy
Рет қаралды 759 М.
air conditioning not cooling house low on r22 refrigerant
12:06
steven lavimoniere
Рет қаралды 183 М.
How to refill air conditioner by R22 (video 32)
8:06
Dahen Zana
Рет қаралды 5 МЛН
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,3 МЛН
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 382 М.
R-22 and R-410A Refrigerant Operating Pressures on Air Conditioning Units!
14:56
Charging R-22 into an Air Conditioner that is VERY LOW on Refrigerant!
25:13
AC Service Tech LLC
Рет қаралды 256 М.
Goodman Heat Pump Leaking R22 re-charged
8:12
Anti DIY HVAC
Рет қаралды 11 М.
Violet Beauregarde Doll🫐
00:58
PIRANKA
Рет қаралды 50 МЛН