How To Diagnose and Fix a Tripping RCD

  Рет қаралды 23,405

sparkydave

sparkydave

Күн бұрын

Пікірлер: 28
@donovanhan7035
@donovanhan7035 2 жыл бұрын
Such an informative video. Thank you for sharing your knowledge and experiences. 👍
@teratakemp5056
@teratakemp5056 3 жыл бұрын
Please do more and keep up the good work
@basilgeorge1593
@basilgeorge1593 4 жыл бұрын
I watching your videos to Learn language and words related to the electrical field.. and iam an Trade person as well..
@michaelcostello6991
@michaelcostello6991 3 жыл бұрын
That was a good catch on the grounded neutral
@steengalunavosa472
@steengalunavosa472 10 ай бұрын
Thank u mate for an informative video..
@bigdogbaz
@bigdogbaz 4 жыл бұрын
proper good lad easy to understand
@Kratos-pz6cd
@Kratos-pz6cd 4 жыл бұрын
Hey mate. Could you do a video on adding new circuits to an existing domestic board. And the test you conduct before and after!!! Cheers. Great videos!
@bertr5650
@bertr5650 2 жыл бұрын
Hi Dave, Curious on DC Fans and whether to switch both Neutral and Active or just Active like a light. I hear varying opinions. Great channel and thanks for your time.
@bertr5650
@bertr5650 2 жыл бұрын
@Sparkydave
@clivecamangon7998
@clivecamangon7998 4 жыл бұрын
Hey man, can you pls make a video on how to wire 2-3 light fixtures on a single switch pls? Cheers!
@ranat5526
@ranat5526 3 жыл бұрын
Wonderful and sweet as!
@Goabnb94
@Goabnb94 4 жыл бұрын
Question from an apprentice. You say that an RCD trip without MCB trip means neutral and earth fault, which makes sense. But if the fault contacts phase and earth, surely that would draw a big fault current (like 800A for example) that instantly trips the MCB before the RCD is able to detect the fault, no?
@MrSlick446
@MrSlick446 4 жыл бұрын
Goabnb94 rcds are designed to prevent large fault currents developing, so trip once a certain earth leakage current is present usually around 30mA, disconnecting circuit before any damage/danger occurs. If no rcd it would rely on MCB to trip but depends how much current is drawn before it operates. 800A would rapidly trip mcb but would damage circuit/ things on it.
@theultradiamondgamer7650
@theultradiamondgamer7650 3 жыл бұрын
RCD TRIPS FOR EARTH FAULTS( I.e L TO E OR N TO E) WHILE MCB TRIPS ONLY FOR SHORT CIRCUITS BETWEE LIVE CONDUCTORS( LIVE AND NEUTRAL).
@Goabnb94
@Goabnb94 3 жыл бұрын
@@theultradiamondgamer7650 The MCB will trip from a Phase to Earth fault. Just which will trip first is the question.
@jamesparlane9289
@jamesparlane9289 4 жыл бұрын
Sparky Dave to the rescue. What should a sparky do if the tenancy tribunal orders the landlord has to get the sparky then gives notice to the tenant and then the tenant kicks the sparky out?
@rowdoradge
@rowdoradge 2 жыл бұрын
If the tenant or occupant denies access to the contractor for a fault on the circuit then the contractor should contact the owner immediately and communicate what has occured. As long as property, people and livestock are not in danger then it's basically an arse covering exercise. If for any reason their is risk of any danger to the aforementioned then remove consumer main fuses (service protection devices) and contact the network operator immediately, then the owner, etc...
@randommusings48
@randommusings48 4 жыл бұрын
How much would you have charged this customer for this job?
@gadwalidost
@gadwalidost Жыл бұрын
Still confuse what was the fault
@goodvibesglobal8453
@goodvibesglobal8453 3 жыл бұрын
You could have used the grounded terminal for the earth just remove the termination label😁
@NZNow
@NZNow 4 жыл бұрын
Ну наконец то. Где пропадал?
@sparkydave
@sparkydave 4 жыл бұрын
Been injured, took a while to recover but im back in force now. Thanks for hanging round!
@NZNow
@NZNow 4 жыл бұрын
@@sparkydave Glad to hear it! Make more video, I'd love to watch it! Do you know the electrician from Christchurch who needs an apprentice? ;)
@guangrun
@guangrun 2 жыл бұрын
hey customer range up and complaining..since someone worked there powerbox, he mucked up their family fan ... 🤣 which had been working for the last 20 years....
@davoc5140
@davoc5140 Жыл бұрын
legend
Intermittent Tripping: These Faults Are The Hardest To Finds
12:49
Eastway Electrical
Рет қаралды 21 М.
How To Verify New Installation and Test MEN Switchboard
34:11
sparkydave
Рет қаралды 72 М.
This dad wins Halloween! 🎃💀
01:00
Justin Flom
Рет қаралды 15 МЛН
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 10 МЛН
😜 #aminkavitaminka #aminokka #аминкавитаминка
00:14
Аминка Витаминка
Рет қаралды 1,8 МЛН
How To Fix Arc Fault Nuisance Tripping For Good!
8:27
Energy One Electric
Рет қаралды 39 М.
How to Test RCDs
14:57
John Ward (jwflame)
Рет қаралды 416 М.
RCD FAULT FINDING! | HOW DID I DO THAT!? 🔎
13:48
Finney Electrical Top Electrician
Рет қаралды 11 М.
How an RCD / GFI works and troubleshooting rogue tripping.
20:16
bigclivedotcom
Рет қаралды 263 М.
Fault Finding - You Will Never Guess What It Was...
13:46
Artisan Electrics
Рет қаралды 150 М.
How To Wire a Switchboard (Part 1)
23:34
sparkydave
Рет қаралды 180 М.
RCDs: Neutral - Earth Faults
11:32
John Ward (jwflame)
Рет қаралды 447 М.
How To Remove a Switchboard
10:53
sparkydave
Рет қаралды 23 М.
Fault Finding RCD tripping - Electrician
20:18
N Bundy Electrical
Рет қаралды 83 М.
This dad wins Halloween! 🎃💀
01:00
Justin Flom
Рет қаралды 15 МЛН