@kkutube1972
@kkutube1972 3 ай бұрын
That remote will be my choice. The whole video, dang, the walk back.
@PressureCleaningSch
@PressureCleaningSch 3 ай бұрын
Yes, saves a ton of time and walking
@ronaldleeejalu3889
@ronaldleeejalu3889 12 күн бұрын
I am starting a pressure washing business and was considering buying the X-Jet M5 to apply chemicals. However, you’ve convinced me to go with the Downstream Bypass Injector instead. Thank you for sharing this valuable information with us.
@PressureCleaningSch
@PressureCleaningSch 12 күн бұрын
Glad it helped. Best of luck you you in your business.
@1painter4hire
@1painter4hire 7 ай бұрын
The " Pioneer Of the Washing Industry " Mr.Rucker 💪
@MrDozier23
@MrDozier23 Жыл бұрын
My go-to place when I need help. The OG Doug Rucker, you gotta love this guy!
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Thank you sir
@kkutube1972
@kkutube1972 3 ай бұрын
Thanks, regarding home owner.
@PressureCleaningSch
@PressureCleaningSch 3 ай бұрын
Very welcome. Thank you
@ApexPressureWash
@ApexPressureWash Жыл бұрын
Nice!
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Thanks!
@kashi2843
@kashi2843 Жыл бұрын
Hey Doug a great video as usual, I had a question hope you can help out - For DownStream injector bypass why to create such an elaborate setup will it not be more efficient if on a regular downstream injector put a ball valve on the downward pipe/hose which pulls the chemical/soap mix... and once that ball valve is shut there is no air intake issue either this simple 1 piece ball valve can also help regulate amount of chemical you need to mix with the water spray ??
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Still will lose pressure and flow. There are adjustable injectors you can do the same thing without having the ball valve.
@cfuzzkennedy
@cfuzzkennedy Жыл бұрын
I was going to ask the same thing. I can’t see why the need for such an elaborate system when a simple on/off valve will shut off the intake. He says you will still lose pressure, but I cannot see how. It’s almost like plugging or capping the injector line or even not having one at all.
@cfuzzkennedy
@cfuzzkennedy Жыл бұрын
So after a little more research, I now understand what Doug is saying. If you have a 4gpm machine and the injector is 2gpm, the internal orifice of said injector will restrict the machines maximum flow. The bypass offered a no restricted path for the water to flow and return to maximum flow.
@kashi2843
@kashi2843 Жыл бұрын
@@cfuzzkennedy Yes that is what I assumed by Doug's statement "still will loose pressure and flow", but my question was in a setup with same orifice sizes, so the doubt and to better understand the physics I checked out other YT experts on pressure washing and all of them had similar concerns of a pressure drop if there is no bypass and then I myself setup a rig to check pressure loss and I did find a noticeable pressure (but not too much) drop if there is no bypass. btw I checked with both orifice sizes same
@coastalcreekwoodworks8795
@coastalcreekwoodworks8795 8 ай бұрын
Hey Doug, when you put your SH in the 5 gallon bucket are you mixing it with water? Or are you just using your bypass with straight SH.
@PressureCleaningSch
@PressureCleaningSch 8 ай бұрын
I use Straight SH
@Bleachsprayer
@Bleachsprayer Жыл бұрын
Would this be a good back up on a 10 gpm machine when your running a dedicated soft wash system?
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Yes, absolutely. But won’t get as strong a mix as the dedicated pump
@kkutube1972
@kkutube1972 3 ай бұрын
If X-Jeting, will this matter. Just because I am still confused.
@PressureCleaningSch
@PressureCleaningSch 3 ай бұрын
X-jetting and Using a bypass are two separate things not to be use at the same time. Hope that clears up confusion. If not let me know.
@nathanpagano989
@nathanpagano989 Жыл бұрын
Hey Doug, is a 100 gallon water tank too small for a 10 gpm unit? The water pressure in my area is pretty good with 5 gpm on the low end and 10 gpm on the high end. I mainly do residential jobs and would like to have between 100-150 gallon tank if possible.
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Should be fine unless you wide open for an extended period. I’ve always 100 gallon on my 8gpm w no issues unless there was a supply issue
@Chilltown13
@Chilltown13 Жыл бұрын
Hey Doug, will the bypass work and siphon with a 4gpm 4200 psi GX390 direct drive ? Thank you
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
Yes it should work fine
@Chilltown13
@Chilltown13 Жыл бұрын
@PressureCleaningSch Thank you will place an order for an RTU
@rickwashek478
@rickwashek478 Жыл бұрын
Does your plug out version limit corrosion on plug or doesn't it matter ?. I have some brass plugs I use and they tend to collect corrosion. I use a brass brush to clean them off. I know I should have all stainless.
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
I use SS plugs. But I use both brass and SS couplers and never noticed a huge difference on either lasting longer due to corrosion.
@rickwashek478
@rickwashek478 Жыл бұрын
@@PressureCleaningSch okay, I was sorta thinking that way. Thank you.
@pressureandsoftwash21
@pressureandsoftwash21 Жыл бұрын
Dont know why, but when I connect 200 feet of hose, it's not pulling any SH from the bucket ??? Any suggestions
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
What injector?. Machine?
@pressureandsoftwash21
@pressureandsoftwash21 Жыл бұрын
@@PressureCleaningSch 2.1 3-5 GPM Injector 5.5 GPM Honda gear drive
@pressureandsoftwash21
@pressureandsoftwash21 Жыл бұрын
@@PressureCleaningSch?
@PressureCleaningSch
@PressureCleaningSch Жыл бұрын
@@pressureandsoftwash21 hmmm very odd it won’t pull. It definitely should. Try it with an open valve or nothing on the end of your hose just to see if it will pull.
@seanjohnsons6915
@seanjohnsons6915 11 ай бұрын
Good for you for looking out for the little man trying to make a living- I’m assuming I can buy online from you so you have a new customer
@PressureCleaningSch
@PressureCleaningSch 11 ай бұрын
Yes sir. You can order here. And thank you. www.dougruckerstore.com
Troubleshooting Your Downstream Injector: Why It Won't Suck Bleach
8:16
King Of Pressure Washing
Рет қаралды 4,9 М.
Downstream Injector Bypass. How and Why it works
15:58
Powerful Improvements
Рет қаралды 24 М.
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Pressure Washing VS Soft Washing from Pressure Cleaning School
23:18
Power Wash Water Tank Float Valves from Doug Rucker Store
29:41
Doug Rucker
Рет қаралды 7 М.
How To APPLY Chemical | Soft Washing Vs Pressure Washing
18:18
Austin Davis
Рет қаралды 69 М.
Injector Bypass- Downstream to Either Reel
5:30
All Pro Exterior Services LLC
Рет қаралды 8 М.
Why Do I Use A Downstream Bypass and How I Rinse My Downstream Injector
33:08
Pink Flamingo Power Wash LLC
Рет қаралды 17 М.
Downstream Injector Bypass Kit | DEBUNKED?!
15:50
Sean Weber
Рет қаралды 2,3 М.