How to Install a P-Trap for Kitchen and Bathroom Sinks

  Рет қаралды 79,981

Hammer & Pine Home Services

Hammer & Pine Home Services

Жыл бұрын

Learn how to install or replace a P-Trap for a Kitchen or Bathroom sink. Avoid using an S-Trap when installing with a vertical, through the bottom of the cabinet, drainage pipe.

Пікірлер: 40
@dannylake1968
@dannylake1968 10 ай бұрын
One of the most informative videos I've seen. Thank you for all the details, reasonings, and thorough explanations.
@meyou8141
@meyou8141 3 ай бұрын
Sorry, it's still incorrect. He drew it right, but his install was the same as an s-trap if not worse.
@JLange642
@JLange642 Жыл бұрын
Loved the defunct new primer lid! Was the brush in the can (broke off) or not there at all? Good video btw!
@johnolock1508
@johnolock1508 Жыл бұрын
Thanks!
@samash1704
@samash1704 Жыл бұрын
Vent? All traps need venting in all cases. Without a vent, the water seal in the trap gets sucked out and sewer gases can enter the room.
@hammerpine
@hammerpine Жыл бұрын
Good catch - and warrants some clarification. First solution would be an Air admittance valve - While not all codes allow one, it would be easy to install one here by substituting the 90 degree sweep from horizontal to vertical with a sanitary T and then placing the air admittance valve usually about 6 inches above the horizontal portion of the P trap. Second would be to create an upside down "U" to create a loop so, a sanitary T to replace the 90 elbows, go up about 6 inches put on a 180 bend and go straight back down. The loop was not chosen since this is a retrofit (just new cabinets and sink) and would be difficult and costly to install. The air admittance valve while possible, is not needed given that the piping for this single fixture is arguably considered oversized as under the floor it quickly increases to 3 inches and the distance to a vertical vent that goes through the roof is about 2 feet. In summary, I would put it this way: a good, better, best scenario. Best would be the air admittance valve, while the better scenario would be what is shown in this video. This would work 100% fine with normal usage. Maybe warrants a follow up video on the specifics since plumbing is simple yet complicated.
@wadeinn463
@wadeinn463 Жыл бұрын
Thanks guys! New project for me.. will get an air admit valve too😊
@WinmanDesigner
@WinmanDesigner Жыл бұрын
Thanks for the video! I'll be doing this later today. Id replaced the faucets that went bad around 6 months ago. And I should have known the assembly would need replacing too!
@patrickmarquez4619
@patrickmarquez4619 5 ай бұрын
Please tell me you didn’t follow his instructions? He literally made a S trap after saying no to do it 🤦🏻‍♂️
@Arthur-wr6zl
@Arthur-wr6zl Жыл бұрын
Can I attach the connection hub directly into the elbow without having a small piece of pvc pipe between the elbow and the connection hub?
@mfoco1
@mfoco1 9 ай бұрын
This is an S-Trap with a length of pipe added at the top of the S. You didn't create a P-trap, and it won't stop any siphon action as it's missing that vent pipe behind the wall.
@jjramz6618
@jjramz6618 8 ай бұрын
This is what you call a long s trap. "Capital S trap? Lol Spanish S?
@dandychiggins9061
@dandychiggins9061 10 күн бұрын
He should've installed an air admittance valve, right? I'm just learning about plumbing...
@billjewell5528
@billjewell5528 5 ай бұрын
What did he solve by doing this?
@user-iu4us6hz7j
@user-iu4us6hz7j 4 ай бұрын
Hi there sinks have a flat bottom discharge which it means it prime's the trap ,same as a bath
@michaeltenzer4635
@michaeltenzer4635 Жыл бұрын
Great video once again! Excellent job Hammer & Pine!
@mejicanito
@mejicanito 7 ай бұрын
Need the sand tee with a vent on tub your not doing a waste arm inside the wall drain is coming from bottom up and need the stud vent unstead of using that 90 should be a sant tee just and advice Godbless
@realexperiences8748
@realexperiences8748 5 ай бұрын
I'm pretty sure that's still an S-trap. You need some kind of vent where the elbow that turns down is. At the very least, using a T instead of the down elbow and putting an air admittance valve on the top of a T.
@bradjenkins932
@bradjenkins932 2 ай бұрын
It's an unvented P trap
@user-iu4us6hz7j
@user-iu4us6hz7j 4 ай бұрын
Hi on a sink a short pipe is code on a hand basin it is not eg a trap vent or a 300mm. 600mm horizon tal 30 to 1 fall
@dandychiggins9061
@dandychiggins9061 10 күн бұрын
Shouldn't you have installed an air admittance valve instead?
@caribbeanbound8357
@caribbeanbound8357 7 ай бұрын
S traps have been used forever and now people act like your house will collapse if it is used. Bizarre
@KingKatura
@KingKatura 5 ай бұрын
I wish my kitchen sink was just one pipe, We like 4 under there, garbage disposal & the wierd way the old metal pipes were hooked
@simonpaine2347
@simonpaine2347 Жыл бұрын
Disappointed! The diagram on the lead in, shows a vent! I wanted to see what kind of vent you installed and all you seemed to do was install a slightly extended s trap. I'm guessing that this will syphon depending on where the vent in the system is, if indeed the system even has a code compliant vent installed.
@hammerpine
@hammerpine Жыл бұрын
The piping for this single fixture is arguably considered oversized as under the floor it quickly increases to 3 inches and the distance to a vertical vent that goes through the roof is about 2 feet from that point. This will (and has) will work fine.
@yevgeniytsarkov7256
@yevgeniytsarkov7256 Ай бұрын
Where is the vent pipe?
@espirite
@espirite 4 ай бұрын
Didn't you just create an s trap after all that?
@jonathanklopf7581
@jonathanklopf7581 6 ай бұрын
I can always tell a novice from a pro by the terms they use to describe the parts they are using," connection hub"?
@mrfabio3760
@mrfabio3760 11 ай бұрын
Funny u talk about no to do s trap and you did one ,instead of the 90°,use a 1 1/2 tee and on top of the tee use a short piece of pipe and on top install a in line vent
@egondzintars8209
@egondzintars8209 11 ай бұрын
this is terrible. After all your talk about P traps all you did was install an "S" trap which is against code. Where's the AAV?
@joshuacragan3321
@joshuacragan3321 10 ай бұрын
I was watching this and I'm like that's the wrong trap why am I watching this
@atvridgerunner
@atvridgerunner 5 ай бұрын
I have the same situation, if I were to put a Tee where the drain is going through the bottom of the sink, then a elbow with a pipe extending up with a Studer vent would that be OK?
@babyhullk
@babyhullk 5 ай бұрын
​@@atvridgerunner tee wye with a fitted end clean out on the top if the drain is back vented
@jasongreathouse1827
@jasongreathouse1827 2 күн бұрын
So I’m doing this and I am set up to have a Tee connected to the P-Trap. I plan to stub up about 6 inches and put Air Vent above the Tee and below would be drain out. Hope that’s correct.
@brad1367
@brad1367 8 ай бұрын
Thats still an s trap tho
@zzubuzz
@zzubuzz Ай бұрын
So how do I know if I've accidentally made an S trap? A: It will smell like S How do I know if I made a correct P? A: If it's a P, it's odor free.
@mbrntly11
@mbrntly11 Ай бұрын
Improper installation
@larryvance2817
@larryvance2817 9 ай бұрын
Sorry Bro you accomplished nothing!,, you should have showed people how to install a auto vent!! Just saying!!
@emiltchilev9026
@emiltchilev9026 5 ай бұрын
Wrong! This is still S-trap and will siphon the water. I hope you are a DIY enthusiast. Not serving customers.
P-Trap Installation: Drain Doesn't LINE UP with Bathroom Sink Pipe - 2022
5:21
The Building Expert
Рет қаралды 1,2 МЛН
Llegó al techo 😱
00:37
Juan De Dios Pantoja
Рет қаралды 56 МЛН
How to Connect a Kitchen Sink Drain
11:08
Pros DIY
Рет қаралды 2,8 МЛН
GOOD P TRAPS, BAD P TRAPS, AND FUNKY P TRAPS!!
8:43
That Fix It Guy
Рет қаралды 135 М.
How to Install Sinks, Faucets and Toilets!
35:57
Home RenoVision DIY
Рет қаралды 647 М.
How to plumb a sink through the floor (complicated install) (AMAZON LINKS)
13:38
DIY for the average guy
Рет қаралды 71 М.
The Astonishing Reason Why The Sink Refused To Drain!
10:29
That Fix It Guy
Рет қаралды 66 М.
Fixing an Illegal S Trap with In Line Vent AAV and P Trap
4:26
Vincent Stevenson
Рет қаралды 14 М.
Когда пытался заново изобрести велосипед
0:11
Короче, новости
Рет қаралды 8 МЛН
Опасность фирменной зарядки Apple
0:57
SuperCrastan
Рет қаралды 10 МЛН
Головоломка от дедушки🔥
0:31
FERMACHI
Рет қаралды 18 МЛН
Что делать если забыл ОЧКИ??? #моястихия #swimming #юмор #fun
0:23
МОЯ СТИХИЯ | ПЛАВАНИЕ | МОСКВА
Рет қаралды 1,9 МЛН
Mummy naya le aayi 🥰
0:36
Cute Krashiv and Family
Рет қаралды 46 МЛН
Será Que a FITA vai Grudar ela na PAREDE😱 #shorts
0:44
Lucan Pevidor
Рет қаралды 38 МЛН