Excellent video. Just getting ready to install one and wasn't sure why 5 inches of tailpiece was needed under the sink but you explain that very well. The instructions also call for over 6 ft of vertical pipe above the check valve before it ties into the outlet. Is that just so that there's water weight to keep the check valve closed? I'm not going to be able to accomplish this in my scenario so hope it's not a deal-killer.
@devoidjames1 Жыл бұрын
this is exactly my question. any resolution?
@timgarvey18742 жыл бұрын
Thank you, very good video!
@bbooe14 жыл бұрын
What do I connect the pump to or how do I connect the pump to the drainage of my house in my garage
@dalelloyd80037 ай бұрын
Do you need a drain vent for this? I want to run it to existing washer drain pipe along with the washer drain.
@bkoz3194 жыл бұрын
excellent video
@RCworstwater4 жыл бұрын
Thank you very much!
@andymccann82365 жыл бұрын
Very nicely done, both video and explanations. I have a quick question: Can I drain a utility tub and adjacent small sink into a single pump, using a T-fitting or something? Thank you.
@botero29love3 жыл бұрын
Can this be set up outside?
@jjeremy3503 жыл бұрын
My pump run constantly i replace the diaphragm still run all the time some told me about check valve?
@DavidGalan7774 жыл бұрын
Good info. Can you give details on whether or not it needs a p-trap and addresses sewer gases ?
@brentmagazine84963 жыл бұрын
It's supposed to be used in conjunction with a "check valve" for basement applications. Gravity weight of the water above the valve holds it shut. If using it ABOVE the level of the sewer line, you would need a flap valve. P traps don't work with forced water because it creates the siphon effect and would vacuum out the trap.
@sagegriot24552 жыл бұрын
I thought a P trap would also protect the pump and collect objects like jewelry. I know the screen is there but screens get removed/misplaced.
@Ace-ig6vs2 жыл бұрын
Can you wash paint brushes and stuff like that without killing the pump?
@powellt01152 жыл бұрын
Can this be used in an office setting to pump water up wall & over to a near by restroom drain pipe? My office doesn't have drain access but needing to install a hand washing sink.
@RCworstwater2 жыл бұрын
As long as the vertical lift is under 10 feet it would work for that.
@robtheisen58445 жыл бұрын
Sweet!
@jayotto3 Жыл бұрын
Does this pump have a built in check valve or is a separate check valve required?
@RCworstwater Жыл бұрын
It has a built in check valve
@darlenepresley59455 жыл бұрын
with this kind of pump, do you need a vent? and if so what does the vent do?
@Victor-nn2wi3 жыл бұрын
You do not
@iasimov59604 жыл бұрын
Good idea. I want to install a clawfoot tub on a concrete floor. It has six inches of clearance. Is there a low profile pump available? How do I achieve the pressure I need to activate the pimp?
@RCworstwater4 жыл бұрын
Please give our techs a call for help finding a solution: 855.329.4519
@chrishodskins74822 жыл бұрын
What size is the union? 1-1/2?
@bkoz3194 жыл бұрын
good stuff
@barboni134 жыл бұрын
Can you tell me the brand and model of the pump. I can’t find one that connects directly.
@RCworstwater4 жыл бұрын
Here's a link: www.rcworst.com/Myers-MUSP125-Utility-Sink-Pump-1/8-HP-115V-p732.html
@daviddistefano15752 жыл бұрын
Can this be used for kitchen sink?
@cymac353 жыл бұрын
What kind pump is it?
@CarlosMunozlapiceron2 жыл бұрын
A very expensive one, You can make it a lot cheaper