@TRS-Tech7 жыл бұрын
erm. spirit level anyone.... As stated this is a great " how to do a crap install " video. I'm suprised he didn't wire it with speaker cable!
@golfwagen41737 жыл бұрын
What mistakes I made
@TRS-Tech7 жыл бұрын
golf Wagen ..... Your mistakes are.... 1. The wrong type of cable, you should never use solid core cable with alarm systems they can fracture and create intermittent faults..... 2. The panel wiring is messy and your low voltage cables are right next to the mains, this puts noise on the wiring...... 3...... I'm not sure of the purpose of the relay but its good that you placed a diode in parallel with the coil...... 4....... The PIR is at the wrong level. It should be at least 3M from the ground or at ceiling hight.......5....... The bell should be outside on the wall, it serves little purpose inside.....6...... When you installed the PIR you touched the sensor head with your finger, this can damage it and reduce its lifespan.....7 ........ There is no fused spur on the mains inlet, I can only speak from a UK perspective but this is a regulation here..... 8 ...... You didn't set the time and date on the system, this won't stop it working but is bad practice..... Finaly the install is rushed, none of the cables are tidy or loomed as someone else has noted. The entire install is just sloppy and no care has been put into it. Good alarm engineers are proud of the job they do and like to make sure the wiring is tidy and the install is neat. Take more care, use the correct cable and follow best practice. I have to say I agree with the comments and I would give you the sack if you left an install like this in a customers home. Sorry to be so blunt but decent engineers cringe when they see things like this. Can I ask what you have used the relay for?
@golfwagen41737 жыл бұрын
He would be a good inquisitor. I will reply later.
@nicom66814 жыл бұрын
@@TRS-Tech Now we wait for your video Stuartbe. Lets see how you put in practice the theroy. Thanks in advance.
@calleheras37273 жыл бұрын
To many mistakes firs mistake the panel its not lavel
@moodrahdule44358 жыл бұрын
some of us we are the first learner please try to speak when ur doing but its very nice...thanks
@golfwagen41738 жыл бұрын
I do not know English, so I prefer silence
@renatomyrto75912 жыл бұрын
Good job , there are so many tools 🛠 out there,proper tools makes proper job bro. Aiaiaia
@fahimhridoy3076 жыл бұрын
Many Many Thanks For your Hard Working to Show us this....
@jorvaughngoodwin79697 жыл бұрын
Thank You for this example even though its not for all and not in english for programming but thanks
@golfwagen41737 жыл бұрын
so
@ISSTECHNZ134 ай бұрын
❤❤❤ your the man bro
@kevinfrazier59148 жыл бұрын
I understand ur just showing us your skills networking do that
@svltanachouaf80303 жыл бұрын
thks a lot i was looking for how to install all this detectors and bell , good job , i can tell after all the research i made , i tray to fix the lousy job one""expert "made
@donaldmututu84476 жыл бұрын
thanks man i got a clue with this thinks from now i can work on tt with a know how...!!
@athenalarm36632 жыл бұрын
Very professional. We manufacture burglar alarm control panel and others. Maybe you can give us a suggestion. Besides, our network alarm monitoring system solution integrates alarm and monitoring in one solution. Maybe it is useful for you.
@dejandex17 жыл бұрын
very helpfull for basic instalation
@alanwestport6 жыл бұрын
You always want to keep the drill motor moving as you break through the wall. This will ensure the best possible chance of hitting electrical or plumbing. Never use a level, most burglars have OCD and this will confuse them if they happen to locate the panel. I can't speak to the rest of the video, I had to stop watching before I got hurt.
@theintruder776 жыл бұрын
My sentiments exactly. This installation is dangerous. I am amazed that the transformer is placed inside the panel and being 240vac that makes it even more fun.
@TRS-Tech Жыл бұрын
Stop it, my sides are hurting ! Would love to see a tube and batten install. It is installs like this that jacked up false alarm rates and is the reason people ignore intruder alarms sounding. Just like many industries you can install something and you can install something properly !
@fahimhridoy3076 жыл бұрын
Many many thanks Bro.......
@hugo.00868 жыл бұрын
Podobný pořad je i o jídle. Myslím že se to jmenuje peklo na talíři. Good luck with the pertinax. Tonek Trósil from Katoda Olomouc.
@golfwagen41738 жыл бұрын
ale dobre som to domontoval, co hovoris na to
@hugo.00868 жыл бұрын
To jo, ale silnoporud nech radsi nekomu jinemu. :-)
@golfwagen41738 жыл бұрын
zelenožltému odborníkovy
@audiophileplanet8 жыл бұрын
THIS IS A GOOD EXAMPLE OF HOW NOT TO INSTALL!
@golfwagen41738 жыл бұрын
'm not arguing
@abankwakingsley74068 жыл бұрын
+golf Wagen .
@HeckLawert7 жыл бұрын
Totally agree
@golfwagen41737 жыл бұрын
What mistakes I made
@grigorstepanyan25816 жыл бұрын
:D
@Malta-fn9wf2 жыл бұрын
Hi, did you programm it using pc or did you from the keypad only thanks
@misribanda55558 жыл бұрын
This type of installation is not up to the standards in Australia,though; it will work. Thanks
@golfwagen41738 жыл бұрын
You're right, but this is a demonstration of how to make it go
@rscelectrical70916 жыл бұрын
Jesus, please tell me this was someone's idea of a seriously bad joke. This guy hasn't got a bloody clue, thought I'd seen some bad installs out on site but the guy takes it to a whole new level. No point asking about a spirit level guys, he wouldn't know which way up the bubble went. Not only a crap job but he's using telecom cable for wiring.
@AlenRedzovic5 жыл бұрын
Why using utp cable for installation? Can you get 6 wire cable for alarm?
@takpednrogiannis87627 жыл бұрын
very good thank you
@golfwagen41737 жыл бұрын
thank for comment
@MsMc1115 жыл бұрын
You will generate hotspots on the wiring without ferrules! They are obligatory in most places so USE THEM! (Especially on the power lines). Also the speaker and the keypad needs reinforced alarm cable because of the power consumption.
@golfwagen41735 жыл бұрын
siren AS500 very little comsuption 100mA only
@theintruder77 Жыл бұрын
Keypads consume so little energy in the form of milliamperes that no perceptible heat is ever generated. Telco quad wire is the norm for installations in Canada. Some ULC systems demand that stranded wire be used but only in commercial ULC locations. Stranded wire has its merits but not in normal residential installations. Cat5 level and higher are not recommended because of the corruption of data transfer between various modules.
@MsMc111 Жыл бұрын
@@theintruder77 Time flies, and I am through a lot of wiring. For the stranded wires, I still use ferrules, even if it's 12V DC, I sleep well that way. And for the wires, we use alarm cables here, 6x0,22 or 8x0,22, and for the siren 2x0,5+6x0,22 for when there is a battery to charge, while the siren is operating. That's what I meant by the reinforced part. But yes, don't use cat5, it is also a mess when it comes to color coding the system. And looks extra bad in the documentation.
@dmzsniper4 жыл бұрын
The reason why this was installed in his secret place is because NO ONE should ever see this mess. 🤦♂️
@garygilbuena83897 жыл бұрын
It gave's me more idea on how to install this alarm system.. Sir Golf Wagen, do you also have diagram? thanks for this video.
@golfwagen41737 жыл бұрын
i am not sir, mick jagger is sir, i am "normal human"
@george80157 жыл бұрын
If only he could also talk..... How great would that be??? Other than that , Great, very educating.
@golfwagen41737 жыл бұрын
добрый день
@User517x Жыл бұрын
How big is the main box, please?
@menthebasilic88497 жыл бұрын
Hello. Thank you for this video. I have a digiplex evo 192. Can i assume it is the same procedure? Thanks
@golfwagen41737 жыл бұрын
Installing the same, but slightly different programming
@Dime_Bar6 жыл бұрын
I don't have a wall with secret place written on it, so can i still fit a intruder alarm in my house?
@majadhussain14942 жыл бұрын
Whole point of adding video is so others can learn .. well of course to get all the hits. FFS commentary is needed..
@Elektroniker638 жыл бұрын
Unprofessional work! No locking resistance (EOL), there is not screening (Shield). I drive the students away because of work like this! :P
@golfwagen41738 жыл бұрын
+Márton Palkó eol I did not use to be operating easier and shield ... to explain - shield what is good please
@martonpalko91198 жыл бұрын
+golf Wagen EOL prevents the plain sabotage of the system. Without it plainer the system, but a pupil can cut it out! The shield protects the system from the exterior electrostatic and electromagnetic disturbances. He will not leave in from a lightning! Read the manufacturer's setup guide.
@golfwagen41738 жыл бұрын
+Márton Palkó I agree, but eol only enhances the protection against sabotage and when he blows the flash and faith in the shield will not help
@zkraiabdoh71136 жыл бұрын
I don't andrestan ....
@theintruder776 жыл бұрын
Two screws is totally unacceptable for installing the most touched item in any security system. The keypad control.
@TRS-Tech Жыл бұрын
Could not agree more. I remember a housing estate that had the first fit done and a local company decided to fit the Scantronic 9800 (if anyone remembers that panel). We ended up checking all these systems that kept going into tamper.... We discovered that the keypads were all mounted using double sided sticky pads (facepalm) .... They had a dodgy enough back tamper as it was ! The installing company ended up having every single URL pulled after the police attended nearly 60 false triggers in under 2 months. I have no objections or problems with someone filming an install.... My problem is that many people may treat this as a "how to" video. This is why the kit and industry have a bad name. Aside from equipment developing a fault a properly installed system should NEVER false alarm. To install a system properly requires the installer to know all the pitfalls like mounting a PIR above a radiator or selecting mouse fart sensitivity modes on detection devices. This may sound petty, picky or over the top but people need to remember that a system that fails to operate can give insurance companies the perfect excuse not to pay out. Would you expect your car to work most of the time aside from the engine cutting out and the wheel coming of now and again ? Not everything is suitable for DIY installation !
@Rymat233 жыл бұрын
As a Smart Home Contractor, this is a horrible, sloppy job. The wrong tools are being used, the panel isn't leveled, it's just very sloppy. I would fire any of my employees if they did a job like this.
@Phouze7 жыл бұрын
wooaawww great instal
@golfwagen41737 жыл бұрын
everyone does not think so, read comments
@harrysharma5545 жыл бұрын
Nice
@machelaronson19247 жыл бұрын
Great Information Video , thank you for your time !
@golfwagen41737 жыл бұрын
thanks for coment
@apapados8 жыл бұрын
Why use relay for the external bell trigger?
@golfwagen41738 жыл бұрын
+Akis Papados reacts to faint bell but on the central terminal there comes less, it should be rotated by a relay
@dejandex17 жыл бұрын
Can you show how to install more then one IC detector on one zone,please. (serial), and how to install TOL resistor?
@golfwagen41737 жыл бұрын
OK
@jbelectric7778 жыл бұрын
you can make these things cut the grass if wanted anymore! just so long as the relay to the outlet is strong enough. Jim besides I'm from US other countries use 240
@golfwagen41738 жыл бұрын
I do not understand
@thearachchies85328 жыл бұрын
hi there, any idea about atz setup, for TC and com port does it matter the wiring or can it be swapped ? As i understand it is just a circuit that needs to be completed in order to set off the alarm from motion.
@golfwagen41738 жыл бұрын
NC contact can be, can be and with EOL resistor
@thearachchies85328 жыл бұрын
ok thanks, do you know much about the programming ? I see i can program the atz by accessing section705., Do i input Power + installer code, then table button and then 705 ? Not sure from there how to enable and disable each option. thanks. I have setup zones 1-5 with 1K ohm resistor and 6-8 with 2.2K Ohm as supplied. thanks
@golfwagen41738 жыл бұрын
The Arachchies I think it is difficult to explain this through comments, be it to study
@user-ol4mk3zo2g3 жыл бұрын
How to operate 10 fire sensors, each sensor in a different zone from the other
@bryancarr61835 жыл бұрын
To whoever made this video. I'm going to break in to your house. The alarm won't go off.
@ColinDH12345 Жыл бұрын
Not level, nicked the line core when you stripped the incoming (4:14), cable types wrong. Good grief... what a shambles!
@shaggy2710737 жыл бұрын
wheres your end of line resistors??,id love to see how you zone double??
@golfwagen41737 жыл бұрын
I also have a video about zone doubling "very special" ATZ
@grahammitchell64358 жыл бұрын
Dont you own a spirit level ??
@golfwagen41738 жыл бұрын
+Graham Mitchell not use am use my eye. 2 eye
@unapro38 жыл бұрын
He doesn't have a hammer either....
@golfwagen41738 жыл бұрын
understant
@TRS-Tech7 жыл бұрын
just spoted the cat 5 cable to. The scary thought is that someone may find this video and think its an instructional video. This video shows some good reasons as to why I think DIY alarm systems should not be sold to the public. !!!
@mianqamar741210 ай бұрын
Can translation what's you doing 😊
@davidreason83342 жыл бұрын
I wanted to cry watching this where do i start 1 NEVER EVER use dater cable for alarm installs 2 all devices should be maxing amount of fittings possible 2 screws in the keypad come on that be falling off the wall in a week or 2 and the bell box well dont get me started and the mess in CIE (control panel) come on if your going to do a job do it right if not leave it to the ppl who can and will
@Viralclown7 жыл бұрын
He stripped the power cables when he stripped the black insulation
@golfwagen41737 жыл бұрын
why
@godmars113 жыл бұрын
Jak u toho paradoxu funguje sběrnice musí se tahat do serie nebo se může odbočovat jako u Jablotronu
@golfwagen41733 жыл бұрын
kdyz paradox zacinal psal v navodu ze do hvezdice a tedy odbočovat dle libosti. ted už radeji tvrdí postupne tahat linky. ale v praxi sem to daval jak mne napadlo. u malyich vzalenosti je to určite jedno.
@chriskeenan16 жыл бұрын
I’m trying to get my head round this. I used to be an alarm engineer many years ago. I always used alarm cable-4,6 or 8 core. Never phone cable! The inside of your control panel looks like a birds nest. That needs tidying up. The mains cable and alarm cable are too close together. There’s a lot of things to talk about here. I always covered the heads of my screws inside my PIR’s with electrical tape. The foam backing on the bell box- am I missing something here? Is that how it’s done now a days? You touched the PIR sensor!- Jeez, I would have murdered an apprentice for doing that. That relay! What the hell was that? Maybe it’s just different standards in different counties, but wow! Was this some sort of demonstration video. Is this a DIY job. So many questions.
@golfwagen41736 жыл бұрын
I'm using an alarm cable in the real world. but often the customer already has a 5e cable installed. I'm going to get involved and there's no problem. I think the problem would be long distances. "he inside of your control panel looks like a birds nest. That needs tidying up" - I agree with it is my weakness relay I give because (because we do not want to program pgm) I only put the insulating tape on the screws when the situation demands it catch a sensor that is no pain
@TRS-Tech Жыл бұрын
100% agree ! 👏
@FarahFetic6 жыл бұрын
Pa sta ti spoji ziv i zdrav bio...i oni sto znaju sad su izbezumljeni....
@SoulMusic20228 жыл бұрын
what voltage is your bell?
@golfwagen41738 жыл бұрын
+Mirsad Alija all parts - bell too 12VDC, 12 to 14,5VDC
@TheBrainwasher828 жыл бұрын
i use 4 wirres for one motion detector coz i use resistors
@golfwagen41738 жыл бұрын
+TheBrainwasher82 you did well
@theintruder776 жыл бұрын
Of course you do because you need 2 for power and 2 for data.
@Mcornish867 жыл бұрын
No explanation as to what he is doing?
@golfwagen41738 жыл бұрын
GIVE ME THE QUESTION - I'm super technician DAJ MY OTAZKU - ja som super odbornik
@The3PLX4 жыл бұрын
golf Wagen Can you tell me how can I wire two or more sensors to a single zone on a Paradox system?
@golfwagen41734 жыл бұрын
@@The3PLX for example use relay. sensor nc com send minus for this relay. relay place in alarm box. sensor on = relay off. relay off = zone open.
@theintruder77 Жыл бұрын
Too many know-it-alls think they can install their own alarm properly. I know alarm company installers that still cannot get it right. Nearly all small alarm company installers are capable of wiring a home for 110vac but hardly any electricians could properly install a professional alarm system. Yet, electricians have to be licensed and alarm companies do not hire licensed alarm technicians because there is no such thing. Thus we get peel and stick systems being installed by the likes of ADT at horrendous monitoring fees and binding contracts by ill trained and installers that can barely speak English.
@ebenezeradejumobi94128 жыл бұрын
Nice job
@golfwagen41738 жыл бұрын
thanks
@mgruzz8 жыл бұрын
How to connect to a modem! Do it with spectra 1759EX
@golfwagen41738 жыл бұрын
+Mario Rosario see my last video kzbin.info/www/bejne/n6qTcqmgmb2Ba6c
@santiagomartinezromero39927 жыл бұрын
Hola amigos necesito ayuda para conectar un un discador gsm a una dsc pc1832. una ayudita por favor
@golfwagen41737 жыл бұрын
Download the install instructions and keep trying
@25monkfish8 жыл бұрын
This is the worst panel wiring I have ever seen 😁 the cables not properly loomed and no connectors used on joints
@golfwagen41738 жыл бұрын
+Colmán Boylan laying in the control panel's my weakness, but it works well
@rtpainting7 жыл бұрын
Does anyone know how to program a phone number on a Paradox 1641 Spectra keypad? please note that this keypad does not have * or # signs. Thanks
@golfwagen41737 жыл бұрын
It is a system SP 1728 old and where you think you can not program the phone number as the user. It has to do Installer
@theintruder776 жыл бұрын
Yes. Call a professional alarm installation company.
@theintruder776 жыл бұрын
This installation is dangerous. The transformer cannot be placed inside the panel box. Not kosher with the electrical code in North America. A level would have been nice. Totally inappropriate 220vac connection and could be a fire hazzard. This video should not be allowed on Utube. This is what give alarm systems a bad rap in the industry. Do not follow this instruction. Please. Cat5 wire should not be used with Paradox Panels. The data transfer can be corrupted between modules and cause many problems. Many things this guy does are not , definitely not acceptable. My company would never let this guy through the door.
@ricardoreix7 жыл бұрын
Hello, when connect the keypad to the central it gives me error: this unit is ready to communicate with the central. Please contact the installer " What can I do to bypass this? The wiring is correct
@golfwagen41737 жыл бұрын
Write What's your keyboard and what you central panel (example panel DGPEVO 192 keyboard K641+)
@andrasszeibert87928 жыл бұрын
Good. And what about the end of line, and atz. A professional technician can use the atz, i think...
@golfwagen41738 жыл бұрын
Yes, but the sample must learn first steps
@maximezankiazankia60788 жыл бұрын
j'ai une alarme a installé de marques pro lay ki prend une puis mes je ne m ensort pas au niveau de la programmation
@golfwagen41738 жыл бұрын
+Maximezankia Zankia Je l'utilise Google traducteur et bien comprendre le français
@jumabaruani4922 жыл бұрын
It's need to explain that silent
@stanimirbg9115 жыл бұрын
If one or two things were done wrong , I would be able to give an advice how to be done in a proper way. But here everything is done absolutely unprofessional.
@golfwagen41735 жыл бұрын
so I wish you a lot of success in your professional life
@nevsehirguvenlikkameraalar66967 жыл бұрын
cok fazla eklemısın kapatmaktan bakmaya zaman kalmıyo
@golfwagen41737 жыл бұрын
Ben kamera kötü bir başlangıç yaptı
@bobwarboat7 жыл бұрын
Why don't you buy yourself a nice pair of wire strippers and a small hammer to tap in rawplugs instead of end of screwdriver?
@golfwagen41737 жыл бұрын
wire strippers are we doing wrong, I often have a variety of cables. Hammer is a good thing, I agree, but I use often installation for short span screwdriver
@mikka86548 жыл бұрын
No offence but if you bending that motherboard with such force when you driving in the screws you will ruin every circuit and soldering on the piece...
@golfwagen41738 жыл бұрын
+Mikka which component mind
@mikka86548 жыл бұрын
Any component that soldered to a board at risk when you bend the board. Cheap manufacturers in China and some shady Europeans make shitty boards and bad quality soldering..so to bend a board is not something I recommend in general.
@golfwagen41738 жыл бұрын
+Mikka My father also told me that, on tightening, and you're probably right
@kaidokraeb5674 жыл бұрын
Tell me your alarm system and I'll tell you if it's good or bad. Trust me you'll be surprised
@ianbisnathsingh59133 жыл бұрын
and that ladies and gentlemen is what not to do
@vedardalarm33282 жыл бұрын
Excellent instruction thank you so much!
@damiao4607 жыл бұрын
tenho central paradoxdpg894 travada o que fazer
@golfwagen41737 жыл бұрын
894 com a gente ou vender
@bernardpeter41784 жыл бұрын
i think the house need a better bricks..
@jeff-TessAD20227 жыл бұрын
I guess hes not going to level it. What kind of system? no intro.
@golfwagen41737 жыл бұрын
level tool missing
@agusprastiyo945014 күн бұрын
Tolong penjelasanya
@adriansuditu62516 жыл бұрын
SP5500 is Spectra, not Magellan
@golfwagen41736 жыл бұрын
adrian, sp5500 mg5050 sp6000 is very similarly programing /one guide/
@istvankovacs27594 жыл бұрын
31:55
@wesselmeiring80568 жыл бұрын
Golf, do you actually know what you're doing?? I've fired technicians for working like that... Oh and in SA, shitty install like that is actually illegal...
@golfwagen41738 жыл бұрын
+Wessel Meiring I do not understand properly because I do Google translation, but it's a criticism I get it
@golfwagen41737 жыл бұрын
mexican is ilegal i am slovak boy freedom my credo / slovakia bratislava sagan,šatan, bondra, chalúpka etc.
@Malta-fn9wf7 жыл бұрын
What the hell did he do wrong?? It was just a demonstration for god sake!
@golfwagen41737 жыл бұрын
right
@AllenGoldsmith6 жыл бұрын
remind me not to call you!!!
@mianqamar741210 ай бұрын
The ar nothing know ectuly he what works
@erikkuzma6 жыл бұрын
Bude niekedy aj slovenská verzia ? :D
@golfwagen41736 жыл бұрын
jedine ze byi som to iste nadaboval
@erikkuzma6 жыл бұрын
TO by som bol za, pretože stretávam sa s mnohými ľuďmi čo si doma robia svoje zabezp. sys. a myslím že im to pomôže. Ale inak super video, čo sa týka ukážky inštalácie aj nastavenia. Prípadne ak by ste niekedy natočili aj ďalšie a boli by v Slovenčine :) Ale to je iba návrh.
@arturssalons2672 жыл бұрын
buy some right tools for this kind of job and then make a proper video...
@mirelmg57206 жыл бұрын
Armed 30:45
@virendra1682 Жыл бұрын
Kya bata rahe ho ?
@jasemat2 жыл бұрын
Possibly the worst alarm install ever, why do people bother making these when they haven’t a clue
@kevinfrazier59148 жыл бұрын
U should explain what ur doing showing just don't help much
@golfwagen41738 жыл бұрын
+kevin frazier My speaking English is bad, so just shows, but I tried to make a good
@EliteGamer9528 жыл бұрын
dobrý den, mohl bych na vás dostat kontakt? nejlépe telefonní kontakt... za ucelem pomoci :)
@TCM-dw3pz6 жыл бұрын
Mains cable going direct to panel transformer? Very bad installation, mains cable should go to an non switchable spur fuse, then from that to the panel transformer. I take it this guy is no alarm engineer.
@blackdatto7 жыл бұрын
I would like to gift you a spirit level. Can you message me with your postal address so I can send you one? I installed my first system when I was 13 years old, the programming back then was dip switches and a pot. Keep up the study on security, I wish you well.
@golfwagen41737 жыл бұрын
Hey, when I was 13 I played hockey in the yard. Work has never been my dream. But seriously - when I filmed this video so I had a camera placed askew, so it seems that I've mounted askew. but not in practice, do not use a spirit level still is governed by the eye. (Monte furniture when there is already a spirit level I use - I have such the ancient, collector's item will make of it video) ...
@smacl616 жыл бұрын
Sloppy work indeed!
@igort30567 жыл бұрын
перфоратор фирмы BOSCH дырку сделает где хошь
@WM-xd8zc6 жыл бұрын
That looks level. lol
@lou.15106 жыл бұрын
Ok , clearly you cut the cable when trying to strip it, wrong wire Gage , panel not level, oh I can keep going, get out of the industry please.
@onergokce93498 жыл бұрын
arkadaş dilsiz galiba:)
@golfwagen41738 жыл бұрын
Biz işe demek
@puregold63794 жыл бұрын
You are not explaining so it's not very effective or educative
@salanimbakile87266 жыл бұрын
paradox
@golfwagen41736 жыл бұрын
for ever
@panagiotiskatakos77117 жыл бұрын
Not a properly made connection inside the panel and inside the detector...Bad demonstration but the worst is that this kind of stuff should not be shown on internet....For godshake this is a security system...End of story.
@golfwagen41736 жыл бұрын
healthy food is more important than an alarm
@vincentgwazani57968 ай бұрын
no sense. you dont talk .
@dallasbailey42242 жыл бұрын
Waste of time just like the alarm system you installed