Sir you have explained very good way, But I would like to add my views,if you connect copper plate at the bottom of earth electrode you will get better Earth
@VijayKumar-oq9kx5 ай бұрын
Sir mujhe bataye ki agar 3 phase supply me 2 phase me tester glow kar rha hai 1 phase me glow nhi kar rha hai magar motor ke pass multimeter me voltage proper 415 aa rha hai
@ali-tj7zf3 жыл бұрын
Nice explanation. Can we connect transformer and generator neutrals earth's together? Also can body and neutral earth points can be connected together?
@AnilAutomation3 жыл бұрын
Yes #anilautomationhindi 🙏
@electricalwithabhishekjoshi3 жыл бұрын
Yes
@mohanji55303 ай бұрын
@@electricalwithabhishekjoshisir mere plate earth ka rejistane 5ohm hai kase Kam Karo ki 2ohm aa jaye
@manjitkumarpradhan7257 Жыл бұрын
Sir hamara company me ekk earthing ka resistance pehele 2.something aarahatha, Lekin abhi 5.something aarahahe ookese
@gauravpant5154 Жыл бұрын
Sir please tell what is happening when earthing resistance is coming 6ohm but earth to neutral voltage is coming 0.3 volt
@dheerajupretiuk0691Ай бұрын
Sir earthling parlal hoti hai ya series
@pankajmishra43 Жыл бұрын
Is that compulsory to measure earth resistance after shutting down of entire system??
@digitalcreator17935 ай бұрын
Siiir....in this May month... So hot days.....In our electrical MCC, PCC panel, R Y B N busbar all working as phase 😮😮😮... How ??? What to do proper details please. Neutral busbar became phase supply... Someone said daily 24 hours water 💦 filling in all earthing pit in MCC, PCC panel.. But. Still Some times its showing phase in neutral busbar 😮😮????? Please suggest me
@bhagyamishra8522 Жыл бұрын
Kya earthing pit me Bentonite powder used karna sahi he please suggest
@ishwarpatel620 Жыл бұрын
Sir 1 earth pit PE kitna equipment ka earthing laga shakte hai?
@kapilkalangutkar4749 Жыл бұрын
How to measure Earth pit resistance using clampmeter. Abhishek joshi ji pls prepare video on this.
@ssinghrajput76263 жыл бұрын
Induction motor me leading lagging power factor Improvement kaise hoga
@sanaparveen96427 ай бұрын
Sir electricity bord se 3 phase and neutral supply aati hai or hamare building me single phase ki tarh use hoti hai but tino phase k wire and neutral wire same size ka hi Aisa q Agr har phase me 5 amp current flow ho rah hi to neutral wire me 15 amp current flow hota hoga to neutral wire mota hona chaie . Yahan system to single phase ki tarh use hoara hai to system to unbalance hai yahan koi 3 phase motor to nahi chal rahe hai system balance ho or neutral me koi current nahi flow horaha . To neutral wire mota q nahi hai plese help.
@prashantkharva45273 жыл бұрын
Sir phase sequence change hone pr breaker ON kyon nahi hota
@electricalwithabhishekjoshi3 жыл бұрын
Agar aapke system mein phase reversal protection active hai to breaker ON nahi hoga.
@HarpreetSingh-dc3dh Жыл бұрын
Please make a video on " how to measure step and touch potential"
@ourcutelittlekitchen13388 ай бұрын
The standard earth practice as per IE rules. Copper plate of 3mm thick (2ft x 2ft) connected to Copper strip 25x5mm thick at a depth of 10 feet and put 5 kg salt and 25 kg charcoal around the plate. 2) For GI plate earthing. Use GI plate of 6mm thick of 2ftx2ft and GI strip 25x5mm.
@ronirajput13663 жыл бұрын
Sir aap meri ek help kardo plz muje ye bata do ki humhare liye electrical ki konsi book sahi rahegi jime hume sab mile padne ko sir plz aap comment ya koi video bana k hum sab ko bata do 🙏🙏🙏🙏🙏🙏
@electricalwithabhishekjoshi3 жыл бұрын
B.L Thereja for Machines.
@bhaskarpakhira8253 Жыл бұрын
How to reduce earth electrode
@ramkailashnishad54292 жыл бұрын
Sir Abhi mere site me transfer k pas pdb me neutral between earth below 2volt aa rha hai but aage plc panel me above 5volt ja rha hai kya reason ho skta hai vahan pe neutral ko direct earth krk dekh liye
@શ્રીમારૂતિનંદન3 жыл бұрын
11kv se hum kitana. kw load use kar sakte ha
@Magicworkfast Жыл бұрын
After doing 2 good earthing also my earthing value is 6.. tried all the best way for my industry.. wat to do now plz help out.. my machine need below 1V .. is it possible to bring this value by isolation transformer??
@prvnpareek11 ай бұрын
Have found any solution.then plz share me...
@akashmuley31163 жыл бұрын
Sir is there any standard to choose electrode length.
@gauravpant5154 Жыл бұрын
Sir please tell the difference between earth resistance and earth voltage
@SM101703 жыл бұрын
Sir is there any vacancy in birla group
@zayansiddique73083 жыл бұрын
Earthing bore 20 feet length hai aur Mai ghaR Ka load ChalaNa Chahta hoon Earth with phase possible hai long time k Liye.
@sunmitraresources96412 жыл бұрын
Sir We are working in Solar industry. As our co. directed us to keep min. distance between 2 earth pit must be equal to rod size. Why ? You are saying interconnect all pit will reduce earth resistance. Then what is meaning of keeping distance in 2 earth pit?
@AjayKumar-ct6ok3 ай бұрын
1 meter.
@manojku259 Жыл бұрын
Sir can you please explain droop CT and AVR to exciter to field exciter tak..
@sukhwindersinghsinghboy84613 жыл бұрын
Sir your video very informative for me
@AnilAutomation3 жыл бұрын
#anilautomationhindi 🙏
@GautamSaini-o8q Жыл бұрын
We need to make earthing grid please help
@lonelyplanet90772 жыл бұрын
Sir could you please elaborate causes of more voltage btw nutral to earth as I tested I found 60 volt btw nutral and earth.....
@bhagyamishra8522 Жыл бұрын
Means your Neautral is floating
@bhagyamishra8522 Жыл бұрын
Neautral not erathed
@ssinghrajput76263 жыл бұрын
Sir exam ke point of view se Scr ke bare me btaye
@afaqarif92693 жыл бұрын
Sir, please make a video on Booster transformer.
@lalitgolhar86893 жыл бұрын
Sir different types of earthing system par video baniya TN-S , TN-C, TNC-S and TT earthing system
@dgvclgebgetco70322 жыл бұрын
7 sr 10 relay keshe kam karti he or kahape lagatehe or konkonsh opshan aatahe
@arvindkumarpal61248 ай бұрын
If length increase resistance also increase
@niranjangupta78063 жыл бұрын
Very well explained!
@AnilAutomation3 жыл бұрын
#anilautomationhindi 👌
@shahlalkhan44022 жыл бұрын
Sir jee diffetent earhing standards k nam aur us me resistance ki.max. allowable limits jo ho te hain explain please
@electricalwithabhishekjoshi2 жыл бұрын
Okay...
@ramansen48123 жыл бұрын
Sir Plc ya dcs se related video banao
@hindistorylmvoice222 Жыл бұрын
Earth to Neutral :- Multimeter ko continuity mai rak kar check kare to earth to neutral short hona chahiye or open.
@magneshpatel51379 ай бұрын
Grounding k sathe short and earthing k sathe open
@zainzain80452 жыл бұрын
My 7ft copper rod is giving 140 ohms how can I down it
@industrialeeiengineering46562 жыл бұрын
If u find any answer of ur question then please let me know
@NAUGHTYBILOTA12345 Жыл бұрын
Mine 8
@avinashk22755 ай бұрын
What kind of soil is
@ganeshsahu50393 жыл бұрын
Hello sir Power plant synchronize and how to work AVR Please sir make video on this 🙏
@AnilAutomation3 жыл бұрын
#anilautomationhindi ✋
@madansharma52012 жыл бұрын
Thank u so much sir
@m.l.gambhirgambhir25492 ай бұрын
👍
@AnilAutomation3 жыл бұрын
#anilautomationhindi Nice explan dear 👌
@electricalwithabhishekjoshi3 жыл бұрын
Thank you..
@wasimsharif82422 жыл бұрын
Excellent
@jaypatel36693 жыл бұрын
Sir,how we find standard equation for choose cable size rating (amp). copper & alluminium cable. For example 1 mm2 cu cable take load approximately 6 amp. Please sir help me.🙏
@diwakardubey30032 жыл бұрын
👌
@vikashvishvakarma4653 жыл бұрын
Sir drawing bhi bataye
@adityamaurya36782 жыл бұрын
Yes sir
@deeptalati38513 жыл бұрын
One que : How much minimum current or voltage is required to initiate or catch a fire ??? Any thumb rule ?
@safiurrahaman5836 Жыл бұрын
Be age to bol
@satyajitnayak15665 ай бұрын
Bhai Saab behave toh acha krlo free me sir knowledge de rye hain so please behave properly.
@akhtermahmudabadi55432 жыл бұрын
مجھے ارتھ کی پاور بڑھانا ہے تو کیا کروں وہ پہلے سے کم ہو گئ ہے