How To Whole Home Surge Protector

  Рет қаралды 8,436

Albert Hoffpauir

Albert Hoffpauir

4 жыл бұрын

Installing an EATON CHSPT2ULTRA whole home surge protector, with solar and multiple panels
www.amazon.com/gp/product/B01...

Пікірлер: 23
@mikeewing6035
@mikeewing6035 3 жыл бұрын
Be sure to use a new circuit breaker manufactured by the same source that manufactured the breaker box. It appears that your new breaker is a Square D while the already existing breakers appear to be made by Eaton.
@gregbartholomy3525
@gregbartholomy3525 3 жыл бұрын
The panel you are working on is a sub-panel. The ground and neutral wires on are two different bars in the panel. You put both ground and neutral wires from the surge protector on the ground bar in the panel. Move the the white wire from the surge protector to the neutral bar in the panel.
@romano5785
@romano5785 3 жыл бұрын
Hi there, you connected both the green and white wire to the same bus bar the manual says to connect the green wire to the ground bus bar and the white wire to the neutral bus bar
@AlbertHoffpauir
@AlbertHoffpauir 3 жыл бұрын
You are correct, the neutral and the ground are connected to each other but the proper way to do it is to split them. I will correct it.
@AlbertHoffpauir
@AlbertHoffpauir 4 жыл бұрын
www.amazon.com/gp/product/B01AQAKRSS/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&psc=1
@SovietUnion181
@SovietUnion181 3 жыл бұрын
You are in south Florida, the mocking bird is singing.
@timflory4767
@timflory4767 2 жыл бұрын
What Greg B said is correct but whoever installed this breaker panel originally failed to remove the tie conductor strap between the neutral & ground buss separating them.
@tylerregenscheid8656
@tylerregenscheid8656 2 жыл бұрын
Shouldn't the surge protection be up at the top of the panel closest to the main feed?
@AlbertHoffpauir
@AlbertHoffpauir 2 жыл бұрын
No, electricity doesn't stop or really start at the top of the panel, it is increasing "pressure" across the entire panel at once. I replaced a unit that was installed by a professional electrician that wired my whole home when it was built by a licensed builder.
@gldf111
@gldf111 3 жыл бұрын
Hi. I have a 200 amp main panel and another 200 amp sub panel next to it. Do I need 2 surge protectors or just 1 in the main panel.
@AlbertHoffpauir
@AlbertHoffpauir 3 жыл бұрын
My understanding is you just need the one in the main panel. I don't have one in my sub panel.
@davetyler8214
@davetyler8214 2 жыл бұрын
@@AlbertHoffpauir You should put one on all panels. Most surges originate from inside the structure.
@AlbertHoffpauir
@AlbertHoffpauir 2 жыл бұрын
The electrician that wired my home only put one on the outside panel, so I replaced it with a better protector and moved the one they installed to the street where I have another panel. These are to protect from lightning strikes and transformers blowing up (for some reason the people around here REALLY like hitting the electrical poles, happens a few times a year). I have never heard of a surge coming from inside the house as nothing generated electricity in there. I do know that big items can draw enough power to cause issues though.
@vincemajestyk9497
@vincemajestyk9497 2 жыл бұрын
@@davetyler8214 A good number do. Mostly Induction motors spinning down after power is removed. About half of all surges originate outside the facility and half inside. A majority of these 'self install' SPD videos are problematic.to be kind. Even supposed 'Professional' installs, usually by HVAC techs. Breaker position all over the place, unnecessarily long SPD lead lengths, not twisting the wires. INCHES matter in how long the wires are. Spec is under 12". Ideally it would be the first breaker after the service entrance cable main breaker, SPD installed directly on enclosure perpendicular from the breaker, Make sure leads are absolutely as short as you can make them and braid the leads if possible. Any self inductance voltage from excessive lead length is added to the Pass Thru Voltage.
@duanesharpjr9512
@duanesharpjr9512 2 жыл бұрын
What do you do if you have no 220 breakers slots left
@AlbertHoffpauir
@AlbertHoffpauir 2 жыл бұрын
I would recommend consulting a professional at that point. There are options but I am sure I don't know them all
@robertsimpson7113
@robertsimpson7113 11 ай бұрын
The manufacturer's instruction say to twist the wires that go to the breaker 1 twist per inch of length!!!!!!!!!!!
@AlbertHoffpauir
@AlbertHoffpauir 11 ай бұрын
Good note, Here is the link I think he is referring to. www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/complete-home-surge-protection/recommended-installation-practices-for-chspt1-and-chspt2-products-pct348102.pdf Not sure why he thought so many exclamation points were needed for a recommendation from the manufacturer but nice to see the enthusiasm ;)
@AlbertHoffpauir
@AlbertHoffpauir 11 ай бұрын
Note, adding the twists is fairly simple, just losen the nut and twist the whole unit the number of recommended twists for your wire length. No need to disconnect anything.
@timmark4190
@timmark4190 10 ай бұрын
Twist which wires?
@AlbertHoffpauir
@AlbertHoffpauir 10 ай бұрын
@@timmark4190 did you follow the link I posted above?
@timmark4190
@timmark4190 10 ай бұрын
@@AlbertHoffpauir Yes. I did. There are 4 wires. Do I twist all of them. Two is for ground and neutral. Do I twist them? Or do I twist only the ones that goes to the circuit breaker
Installing an FS140 Siemens Surge Protector
16:56
abrelectric
Рет қаралды 69 М.
НЫСАНА КОНЦЕРТ 2024
2:26:34
Нысана театры
Рет қаралды 647 М.
100❤️
00:19
MY💝No War🤝
Рет қаралды 24 МЛН
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 11 МЛН
Inkster company installs windows on wrong house, leaves job unfinished
3:49
Click On Detroit | Local 4 | WDIV
Рет қаралды 29 М.
Surge Protection
4:56
Eaton
Рет қаралды 56 М.
Installing Whole House Lightning Protection | Ask This Old House
4:04
This Old House
Рет қаралды 177 М.
Generate  Free Electricity 240 Volts On Glass 100% Real
23:35
techni for
Рет қаралды 5 М.
How To Install A Surge Protector
11:14
Electrician U
Рет қаралды 165 М.
EATON WHOLE HOUSE SURGE PROTECTOR INSTALL FROM START TO FINISH
21:28
ETPC EPIC TIME PASS CHANNEL
Рет қаралды 38 М.
НЫСАНА КОНЦЕРТ 2024
2:26:34
Нысана театры
Рет қаралды 647 М.