For future people watching they incorrectly connected the neutral and hot together on the neutral bus. They fixed it in their next video yet I don’t think they ever mentioned their huge and dangerous mistake. If you have one of these square D sub panels do not do what they did.
@phillipmccain76013 жыл бұрын
Agreed and 10-4 that
@reluctantprophet3 жыл бұрын
It’s also installed upside down...
@jbdesignandconstruction3 жыл бұрын
what they should’ve done is deleted this video and made a new one 🤦🏻♂️
@pl8333 жыл бұрын
Yeah the video I was like " no....no...no" .
@douglastheriaque54862 жыл бұрын
Yes, absolutely
@jenniferharter18273 жыл бұрын
As of 7/27/2021 this video still has not been corrected. I appreciate that this video was made as it was the only instructional video I could find for this specific box, but in this video both the neutral and one of the hot wires are connected to the neutral bar. The neutral should be where the left hand hot wire is (parallel with the hot wire on the right) and the second hot wire should be connected to the other end of the hot circuit. In this case, the second hot wire connection should be all the way to the left and slightly above the right hand hot wire (if you install the box right-side-up it would be all the way to the right and slightly below the left hand hot wire).
@sergcamargo13433 жыл бұрын
I agree his ass gonna get shocked
@AaronBregg2 жыл бұрын
@jennifer harter Make one for us rookies!
@RandomTechWZ2 жыл бұрын
And now that one hot is too short to reach the correct location lol.
@jorgerios1420 Жыл бұрын
They also installed it backwards, and flipped the whole panel around at the end 😂. Look at the breakers before and after
@barrymclaughlin7943 жыл бұрын
This video shows the INCORRECT way to wire this panel, at 6:01 in the video you will see that both the Black (Hot) and the White (Neutral) are connected to the same bus bar. This video should be corrected or removed.
@bobbyj78063 жыл бұрын
You clearly aren’t a Electrician
@jameslawnmowerrepair2 ай бұрын
@bobbyj7806 You're clearly not very smart, watch the video, please don't wire how they did, you'll be injured
@Threshold20122 жыл бұрын
The older guy says "He was an electrical contractor in another state" Is that where he learned to land a Neutral and a Hot wire to the same buss? You may wonder why they didn't show a circuit test at the conclusion of the video! This video should be flagged for removal due to dangerous and incorrect procedure.
@RustyPumpkinRanch2 жыл бұрын
I bet they got a surprise when they turned the power on, since they hooked the power to the neutral bar.
@RangerMorris2 жыл бұрын
omg I was just thinking the same thing i was like wait a minute they hooked a hot to a natural omg can we say flash bang lol+
@EnriqueSanchez2 жыл бұрын
my words exactly
@tedyBear592 жыл бұрын
He did not attach power to neutral bar. He used a black wire wraped in green tape for Id purposes. Its commonly done everywhere
@rongraham1730 Жыл бұрын
I thought it was just me😂. I just did one of these so I second guessed myself for a second.
@beaniril8870 Жыл бұрын
@@tedyBear59--that’s the ground wire. The white/neutral wire and a hot wire all clamped together in the neutral bus bar
@rcud12 жыл бұрын
yeah, you put your hot onto the neutral lug that has plastic around it on 3 sides. The first hot lug is up to the left of that. I almost thought the same thing when I installed mine.
@thedailyveteran31012 жыл бұрын
The box is upside down in the beginning. Note the breakers put in. Then note breakers at end. Wonder if when box was turned around if they had some short wires? Reason I noticed it. I have same box. The word Top is engraved inside the back
@TipsNNTricks2 жыл бұрын
Correct, we noticed that and turned it around:)
@thedailyveteran31012 жыл бұрын
@@TipsNNTricksdid it tooo. Lol
@MC-de6tf Жыл бұрын
The layout on the panel can confuse you if you are not watching close or have not identified hots versus neutral bar it is possible to connect hots and neutral improperly.
@Burtchiropracticrehabilitation Жыл бұрын
1. Box is upside down, the holes a ground bus bar used for attachment of the box 2. Neutral and hotwire on the same bus bar - hope there is no fire 3. Kudos for doing this box though. Hope these guys are safe
@kcuhc84 Жыл бұрын
It's also now code that the breaker "ON" must be up not down like here. The panel has been installed upside down. It would be fine if the breakers went east/west the "ON" can be either left or right.
@ETTE-d4z9 ай бұрын
Neutral is separated from the hot wire it just looks like they are connected. I have the same box and the way he connected the wire are correct and yes the box is upside down.
@ETTE-d4z9 ай бұрын
********** Sorry he did connect the hot to the NEUTRAL WTF
@DanielTeague-pr1js Жыл бұрын
How is this video even still up!!! Totally wired it WRONG !!!
@phillipmccain76013 жыл бұрын
Why did u put your white parallel to your hot wire this is not right power is on the bottom and Top screw
@jbdesignandconstruction3 жыл бұрын
Yikes! Could’ve been avoided had he installed it the right way by that I mean not installing it upside down .
@icandreamstream3 жыл бұрын
I just bought this box and was like “wait wtf are they doing!?”
@phillipmccain76013 жыл бұрын
@@icandreamstream yeah I bet when they turned on power they found out real quick that That shit was wired wrong 😑 kinda like a boom 💥 sound idk 🤷♂️
@phillipmccain76013 жыл бұрын
@@jbdesignandconstruction yeah some ppl just dumb
@Baasicstuff11 ай бұрын
Why is this video still up? 171 thousand subs and you just showed everyone the wrong way to do this. Unbelievable. 72 thousand views....$700 really dude WTF?
@KevinCoop1 Жыл бұрын
10 months ago I commented that there should be a ground rod (grounding electrode) connected to this panels ground bar as required in Article 250. No comment from anyone! If you do not test the rod to prove 25 ohms or less resistance, then you are required to install two ground rods. The ground rods are for the purpose of sending lightning to Earth, not ground fault in any way.
@rileycrain57843 ай бұрын
Hi, I was just going to ask if they should install a ground rob. Of course I’m installing a sub panel in my detached shed (70ft), and I’m curious if I install a ground rod
@KevinCoop13 ай бұрын
@@rileycrain5784 Before I answer, I’m going to tell you the ground rods function. Ground rods are connected to electrical systems to dissipate lightning to earth to lessen damage within the system. Normal sub-panels in the same structure are not required to have grounding electrodes (ground rod or others). But when you feed a detached structure, you are required to install two of them. Unless you test it for only one. Just so you know. You are also required to have a means of disconnect in the incoming feeder to the detached structure at or near the point it enters the structure. What does that mean? If the feeder enters the structure, at the panel, a main breaker will satisfy the requirement. But if it enters and the sub-panel is further than (let’s say 10 feet of conductors) then there must be an enclosed breaker or a safety switch. Non fusible meets the requirement. Any other questions?
@bubbleslovebird4974 Жыл бұрын
I only have one hot to connect to it. How do i connect the other side? Ps. Im not electrician savvy but i did catch that mistake.
@GadgetMan77710 ай бұрын
Was wondering the same. I have heard you can jump them but not sure
@capnleux Жыл бұрын
Why not use the lugs?
@jerrynonofbss25882 жыл бұрын
To the viewers, don't do as they say and do. Skip this video if you don't want to burn your house down! I can't believe this video is still up. They need to be fact-checked. Also, spend $80 bucks and get a permit to do it, it's worth it if you don't know what you are doing.
@joyceattaway90813 жыл бұрын
you do not put the white neutral to the hot bus bar !!
@Threshold20122 жыл бұрын
I know what you are saying, but actually they put the White wire where it should be, and the Hot wire on the Neutral buss.
@BruceDuffus2 жыл бұрын
The white wire is on the neutral bus, but it should go where they put the first hot wire - the big terminal on the left of the neutral bus.
@badejenkins2 ай бұрын
So I see now the white wire should have gone to the big lug where he pulled the black wire to and the black wire should have gone to the upper lug at the top left
@johndavies2949 Жыл бұрын
You have your panel upside down. Code violation. On a circuit breaker the handle on the breaker must be down in the off position.
@donl14102 жыл бұрын
Should have been titled, "How NOT To Wire Your Main Wires For Sub-Panel Electrical Box For Home Garage Pole Barn." Totally rookie errors for "dad" being an electrician.. As soon as that 70 amp breaker in the house "blew" they should have reshot the entire episode. I guess KZbin doesn't protect us from negligent activity, just "naughty" subjects... Panel was initially installed upside down. Ungrounded phase conductor and neutral (grounded conductor) landed on neutral bar. Where is the GEC and Grrounding electrodes? Never was addressed.
@mikejustice1196Ай бұрын
Pop, I don’t think you need a parrot in your background, because you were doing just fine.
@tomg9476 Жыл бұрын
Yeah, that whole wiring to the neutral bar twice thing got me. Also, the box is upside, so that should’ve been my first clue..
@haboud7051 Жыл бұрын
Very dangerous, got both neutral and live wire connected together.
@jbear83 Жыл бұрын
I’m glad I’m not the only one who caught they wired it wrong. If you don’t know 100% what you’re doing, DON’T do it. Call a professional, that’s what they are trained for.
@CarlosCastro-ij7nb3 жыл бұрын
Please Please Do not connect the black hot wire on the right next to the white (incorrect) it should be connected to the far right of this particular panel! This video should be removed before someone gets hurt or cause serious damage to your home. Did like the video very much on instructions on how to install but needs correction if haven’t already!
@Barnabus332 жыл бұрын
glad someone pointed this out
@RedPillLife19662 жыл бұрын
How to burn your house down in 9 minutes and 33 seconds or less.
@JoaquinRamos-f4j2 ай бұрын
I noticed that and i was going to comment on that, he left the top buzz bar empty and connected one hot wire on the neutral bar.
@JDStaffylover Жыл бұрын
Per Code you must drive a ground rod for a sub panel in a separate building.
@rileycrain57843 ай бұрын
How many ground rods?
@JDStaffylover3 ай бұрын
@@rileycrain5784 I do 2. Code states that that is the max. You can do 1 if you get a OHM reading of 25 or less.
@JDStaffylover3 ай бұрын
Code states that you can drive one if it is 25 om's or less otherwise drive 2.@@rileycrain5784
@JDStaffylover3 ай бұрын
OHM's
@rileycrain57843 ай бұрын
@@JDStaffylover thanks pal
@aammiranda8 ай бұрын
Great video. Thank you
@destroyneverdie26989 ай бұрын
Thank you so much for the video it definitely helped me out
@aksuarezjd2 ай бұрын
No! it is wired wrong! don't do this. Read other comments.
@LatrieceWilliams-oy9nc Жыл бұрын
Yummy four I saw that's cool yeah always wanted to now what's important and what I should string
@ricksnow8036 Жыл бұрын
Why is this video still up? Hot wired into neutral bar. Boom.
@keithharrington87152 жыл бұрын
Every day is a chance to learn something new. Read through the comments and many people question many things..... Is the panel mounted up-side down? Can you mount the breakers so off is up? Was th panel marked. "THIS END UP"? Did he physically get the wires in the correct place? Does the building require a seperate ground rod and ground wire? What about a building disconnect switch near or on the outside of the building? This may vary based on your local building department. Another videoer got a permit for his "pole bar" as an "agricultural building" which added extra wiring requirements based on NEC 547 (I BELIEVE). Specific wires or conduits based on expected animals housed/stored there. The building department or your local Electricians are great esources to get everything correct. Inspectors go from jobs items to job site and see many different ways it was done and your locals may have solved a problem last week that do not even know you have. Take care and be safe.
@FastEddieQ2 жыл бұрын
Appreciate your time
@mrc99533 жыл бұрын
No one ever includes the install of the breaking in the main panel and wiring the conductors...
@jameslawnmowerrepair2 ай бұрын
That's what I've been looking for!!!!!!!
@WayOfTheZombie6 ай бұрын
hope they used a breaker before that panel because that hot n neutral tied together is a dead short
@salehprohim98122 жыл бұрын
Great video! Thank you!
@donl14102 жыл бұрын
Just don't do it like it's shown in the video.
@johnrudd48093 жыл бұрын
If I was TipsNNTricks I would pull this down.
@joekirkendall13452 жыл бұрын
No way... I clicked on this vid for a similar project at my house and recognized the voice! Great work guys! Great video! :-)
@alanperez143 жыл бұрын
Take this video down. Yall got it wrong in this video
@FastEddieQ2 жыл бұрын
But, please correct the only mistake you made connecting your first hot wire to neutral! Otherwise excellent video👍
@brutally_honest2 жыл бұрын
wft is going on, is this still wrong?? it looks right to me, I cant figure out if Im stupid or if this was changed. WTF is going on with this video I want to wire my panel tomorrow!! very confusing, the comments. 😅
@FastEddieQ2 жыл бұрын
@@brutally_honest yes it is wrong, electrical panel is up side down, but by code it’s still ok, specially if it is place outside under the elements of Mother Nature, but if panel is installed inside it doesn’t necessarily has to be upside down… as far as wiring goes, he installed the main neutral wire to the neutral bar instead of the neutral main slot and then he installed a main hot to the neutral slot, this is wrong… the first hot he installed should’ve have been installed above the neutral main slot the rest was fine.
@FastEddieQ2 жыл бұрын
@@brutally_honest in other words where he installed the main hot coming in, this is where your main neutral wire goes, then in this case, above the main neutral slot, there is two more slots were the two main hot go in, hope this helps
@brutally_honest2 жыл бұрын
@@FastEddieQ I saw that the panel was upside down, and then in the final shot its turned over.. also confusing, like is this the same panel?!! Crazy this is the only video explaining how to wire these things.. I'm going to wire mine and make a video of it so it will be clear, once and for all.
@brutally_honest2 жыл бұрын
@@FastEddieQ ohh yes i see now he installed the hot to the neutral 🤦🏽♂ good catch.
@beaniril8870 Жыл бұрын
The funny thing here is these two clowns sound like they really know what they were doing. Neutral bus bar and live wire together?
@heroknaderi3 жыл бұрын
I enjoyed it. Great job. (Oh the box seemed upside down when you were installing the breakers) I appreciate your time.😁😎👍
@mathieuchenier95512 жыл бұрын
Thought I was crazy but the comments proved me right. For the love of pete, don't connect your hot wire to the neutral bar...
@KevinCoop12 жыл бұрын
No grounding electrode conductor or electrode? Violation of NEC!
@UwwBlake9 ай бұрын
I have a sub panel in my garage like this. I wish there was a cover that actually covered up the breaker switches... not the greatest design.
@AA8285 ай бұрын
I totally agree.
@ronaldtreitner14603 жыл бұрын
Among the other things wrong with this, isn't the box upside down.
@kevinmach7303 жыл бұрын
It definitely is- I think that may have been what confused him in incorrectly connecting the neutral and hot to the same conductor.
@tedyBear592 жыл бұрын
Great video, right to the point. Thank you Sir
@cpt84242 жыл бұрын
It's actually not. This is extremely dangerous how they did this. Copy this method and you will probably die before you have a chance to to praise anyone else's errors and shortcomings
@m3thid3 жыл бұрын
The hot and neutral connections are not right, see the other comments! Delete this video!
@cakeismtrader42272 жыл бұрын
This is so wrong take this video down before others get hurt
@wolfpack20072 ай бұрын
I bet the fireworks lite up when they applied power! Why is this video still up?
@cakeismtrader42272 жыл бұрын
Better have got it inspected and approved by local electrical safety authority
@2004niteshift2 жыл бұрын
he incorrectly connected the neutral and hot together on the neutral bus
@jerrtheripper13497 ай бұрын
Wow 😮
@avguytx436124 күн бұрын
So how was the fireworks show when this was done?
@ZPDSurvival3 жыл бұрын
Very Dangerous.
@3636054 Жыл бұрын
As Monty Python (John Cleese) would say, "Let's not worry about WHO killed WHO."
@Jat0ne Жыл бұрын
For real!?
@thomasharman70792 жыл бұрын
They should not go near anything electrical !
@jbdesignandconstruction3 жыл бұрын
Do not turn it on!!
@paulflores43312 жыл бұрын
Where the hell is part 2?????
@cakeismtrader42272 жыл бұрын
They didn’t get that far
@norsk54472 Жыл бұрын
do a continuity check first
@everettogden81322 жыл бұрын
You should really delete this video because of the incorrect install, dangerous.
@fizwin12 жыл бұрын
This is the messiest video I have ever watched. I installed the exact same panel years ago and of course mine looks nothing like this... We know they wired it wrong, and why would you NOT use the main lug for the Neutral? That should have caught your mistake right away!!!. Sorry guys thumbs down. Take this video down.
@itzBiscuitsB10 ай бұрын
ya ummmm CAUTION folks
@keltecshooter Жыл бұрын
The most bassakward video ever, this is a dangerous video and should be taken down
@constantbrousseau77585 ай бұрын
It’s also not legal because the panel was mounted upside down. Lol😂
@robsp322 жыл бұрын
What the hell? I followed these instructions and now my shed burned to the ground.
@richardschumacher70722 жыл бұрын
Should be taken off , trying to be respectful but this is very dangerous to leave posted!!!!!!
@richardschumacher70722 жыл бұрын
Box upside down that should be a clue , please remove this garbage!!!!!!
@adamortega277 ай бұрын
Ain't no way
@allenshaw21882 ай бұрын
I’m pretty sure you’re wiring that wrong
@tankbrook3 жыл бұрын
are you trying to kill someone????? please take this down. you wired the hot in the neutral bar
@stanloos552 Жыл бұрын
You hooked your first hot wire to the neutral lug. Don't do a video if you don't know what your doing!
@cakeismtrader42273 жыл бұрын
Dangerous Wired that wrong don’t do it like this he has hot and neutral on same bus 🤦🏽♂️ and box is upside down 🤦🏽♂️
@cakeismtrader42273 жыл бұрын
I wonder what the out come of this was ? Probably felt dead and alive at the same time for a few seconds.
@FastEddieQ2 жыл бұрын
It doesn’t matter if sub-panel is upside down, unless it is outside then yes otherwise the only problem I see is a wiring mistake… please correct me if I’m wrong.
@cakeismtrader42272 жыл бұрын
@@FastEddieQ that’s right but it’s not recommended unless you have no other option also need 30min fire wall and so much distance around panel
@FastEddieQ2 жыл бұрын
10/4
@makojuicedaniel93072 жыл бұрын
No one wants to show where ot hooks into tge main box
@foxbmd157 ай бұрын
Prolly should be making videos if you don’t know what your doing your going to kill somebody looking for information that your giving improperly this is wired completely wrong nobody do what they did