I have a job like this coming up next week and now I know how not to do it so found it helpful. And yes I will be doing a zs and an IR test. And the copper will come in from the back. And I will also test the RCD as it is a split board.
@asef6985 жыл бұрын
Would of preferred the copper pipe to push in by back entry, looks like a council job with the pipe on show
@fireblade89055 жыл бұрын
How ?
@paulgreen0084 жыл бұрын
I agree the shower could have been an inch lower, pipe entering horizontal instead of vertical. Made more work for himself putting an elbow on there.
@jokeaaaa2 жыл бұрын
I don't understand why he used an elbow when he could have just push fit the inlet pipe from the back cover
@ciprian10002 жыл бұрын
@@jokeaaaa because it’s a push fit . So once fitted u can’t take it out if it comes from the back unless u have rear acces.
@anthonygaunt89742 жыл бұрын
I was also thinking along them lines
@MMG_MoonManGuitar5 жыл бұрын
Nice to have you back. 👍🏾
@mango35865 жыл бұрын
this was very neat job well done
@tobir1beetle3 жыл бұрын
Se conecta a la luz normal o hay que hacer una conexión especial?
@primavera9192 жыл бұрын
Why did you test it on one pipe? What about homes with 2 pipes (Hot & cold)?
@streetlewis2202 Жыл бұрын
I would want that copper pipe showing in my bath room
@jjjones33013 жыл бұрын
would this work in a bungalow with good water pressure
@Andrei92ify2 жыл бұрын
hi there , i had bought a bristan instant hot shower, now i have two pipes hot and cold what i supose to do with the hot one ? thanks
@ArmedTechs2 жыл бұрын
You put an End Cap on it
@dianedoran38252 жыл бұрын
Hi there .so i have just had an 8.5kw shower installed on a 6mm cable , i have been told the cable needs to be 10mm cable , will this be dangerous
@zippymo6722 жыл бұрын
It depends on the installation method. If it is clipped direct it will carry up to 47 amps. If it is installed inside conduit and embedded in a wall then thw current carrying capacity is reduced to about 32amps. Ideally the cable should be 10mm because if later in the future you decide to uograde the shower to a more powerful one, then the 10mm will cover that.
@iputyouinmyoveni55415 жыл бұрын
Mine doesn’t have any sort of pipe at the bottom, and the pressure of the water isn’t strong at all?
@jjjones33013 жыл бұрын
dont you have to turn off the electric at the mains when you do this ?
@fireblade89052 жыл бұрын
Lol
@regobertlee92545 жыл бұрын
Hi Sir, Great video tutorial. I installed this same shower unit but when i turn it off, water is still coming out of the shower head. Any help pls?
@watsonbrown95423 жыл бұрын
YOUR BUTTON MAY NOT HAVE BEEN IN THE RIGHT POSTION BEFORE YOU PUT THE COVER BACK ON
@dannyarcher Жыл бұрын
Omg what is that sparky doing to the copper plumbing - using Yorkshire solder as well 🤦🏻
@samibenben74752 жыл бұрын
Can this shower work in Africa 240w power
@davidgom30463 ай бұрын
Yes 100%
@ericthekingthekingtheking48425 жыл бұрын
The point on these videos shouldnt be look how easy this job is it should be if your gonna mess with 6mm shower cable can you prove that cable is dead before and after refit of shower and i dont mean wave a voltage pen over it, and if the answer no then then you shouldnt be touching the job full stop
@namski24105 жыл бұрын
Am I the only one thinking that this video is a good example of bad practices. Firstly, the rating of the cable. Although the shower capacity was not mentioned, 6mm cable for any electric shower should just be a no no. Secondly, force cooling the pipe weld. I mean this must not be done under any circumstances. Common on, how long does it take to cool naturally? Not sure this video is one to recommend. Quick job, bad practices
@d34nr2k84 жыл бұрын
Shower capacity is mentioned 8.5kw
@namski24104 жыл бұрын
@@d34nr2k8 you are correct. What I meant to say was that although the shower capacity was mentioned, 6mm cable should not be used for electric showers. I just think is it bad practice and should not be encouraged. 6mm cable could only support up to 7.5kW rated shower at best - not sure I have seen one of such capacity anyway
@IAmThe_RA Жыл бұрын
@@namski2410 8.5kW requires around 38A at max. On paper 6mm² cables are rated at 41A but it can handle much higher current like close to 50A.
@fireblade89055 жыл бұрын
Perfect
@duncanwright45093 күн бұрын
6mm calbe is too small for a 40amp breaker.
@abooli25 жыл бұрын
6mm for 8.5kw bet that will burn out why not 10mm And where's your Zs testing nd is the showr rcd protected
@d34nr2k84 жыл бұрын
lucky lee also no double over of the earth wire just straight in the connector block.
@farooqshah27974 жыл бұрын
plumbers dont do Z tests they screw it in ..switch it on .. no leaks ..jobs a gud one ..go home =D
@zero2005uk2 жыл бұрын
Ok, I've been watching your videos on installing everything, but there's a saying "Jack of All, Master of None". Kitchen fitter, chippie, plumber and now electrician! There seems to be no end to your talents! For an 8.5KW shower the recommended cable size should be 10mm and be protected by an 40A 30Ma RCBO. I didn't see any local double pole 40A isolation switch, nor any local water shut off valve! It's fine being the jack of all, but messing with electrics can kill! I presume you'll also fit gas appliances.. You're just fantastic and probably cheap too. Building Regs, Part P, City & Guilds, who needs any of that? Just watch KZbin channels like yours, there's no longer any need for qualified tradesmen anymore. Yours, Paul McGuinness
@hippopotamus86 Жыл бұрын
Doesn't look like a power shower. Has no pump.
@waqasbtm12 жыл бұрын
40A 10mm cable
@subframe69393 жыл бұрын
Thats a basic shower not a power shower as the title says?
@bogdanbrais92312 жыл бұрын
The pipes should not be visible... You should never heat a copper pipe when you get a push fit so close... Sorry to say but this is a big NO.
@xeeshan1263 жыл бұрын
This guy has other great videos. But, I am not so impressed with this video of his, as he didn't mention the cable from the MCB will terminate on the RCD and then to the Electric Shower. The RCD of the RCD will depend on the Shower Rating.
@rfmlets6713 Жыл бұрын
Why make a bend in the pipe? You could have put the 15mm pipe straight into the back of the shower.
@lesliemole3671 Жыл бұрын
In Thailand you have two white cables and one black your vidio was no good
@streetlewis2202 Жыл бұрын
10mm cable not 6mm
@IAmThe_RA Жыл бұрын
8.5kW will need around 38A at max. On paper 6mm² cables are rated at 41A but it can handle much higher current prollybclose to 50A.
@streetlewis2202 Жыл бұрын
@a_d2673 Correct, thanks for the heads up. Have a nice day