As a Professional HVAC installer with limited service experience, I find this video easy to follow and understand. Thanks for the video.
@JumpermanTech3 жыл бұрын
Thats awesome! Glad you found this video easy to follow & understand. I appreciate the feedback🙏 Stay safe out there & stay tuned for new videos every week🔧
@jollyscaria19222 жыл бұрын
Vrey good welcomed
@jollyscaria192211 ай бұрын
Vrey good trmial good celing testimeinv metar tedtkmg 3trmisls very good groundd no contuvit tedtinv maghet tedtinv good sdhowinv sound comeinv body vomd no ok goos come not good yes righted all3point refing sdhoeinv iz good wdlvome gues yes sirok
@smith660311 ай бұрын
Am admiring your videos, they are teach me amazing ways to level up my education.
@RalphbeingRalph Жыл бұрын
This helped me a lot furthering my HVAC career
@1mandynasty7274 ай бұрын
So easy you made this video 😮
@anvibrimel412 жыл бұрын
Thanks for the teaching,and a have a question what meant is when checking between the Wingdings you get OL on a 3 face compressor,exactly the same like you used to teach. Thanks for the answer y your time
@JumpermanTech2 жыл бұрын
You're very welcome & thank you for watching! OL would mean you have open windings which means you have a bad compressor and it must be replaced. What you are checking is the resistance of the windings to see if they are in tact or not. The best test for this is to use a meter called a megohmmeter and I made a video on how to check all kinds of compressors with that. Stay tuned for new videos every week🔧⚡️
@Steven-wp6pr9 ай бұрын
I liked the way you were direct and no fluff
@noonej6523 Жыл бұрын
The compressor I’m testing right now currently has no resistance but all three of the thermals are giving me a diffrent ohm reading what could be the reasoning for this?
@chrismuniz85153 жыл бұрын
Perfect demonstration str8 to point
@Eddy63 Жыл бұрын
Good info Jumper ... Thx
@aliqtr74954 жыл бұрын
Thanks ,u teach in easy way .GOD bless u
@JumpermanTech3 жыл бұрын
You're welcome & thank you! I appreciate that very much. Stay safe out there & stay tuned for new videos every week🔧
@alexeytech14954 жыл бұрын
Great video for the technical personal.👍
@JumpermanTech3 жыл бұрын
Thank you very much! Glad you found this video great🙂 Stay safe out there & stay tuned for new videos every week🔧
@techfive72024 жыл бұрын
Dont do much light commercial. Mostly residential. I had an rtu 3 phase carrier today 10ton that the compressor terminal port blew out and leaked all the refrigerant. Tested ohms across and got 5ohms on each leg. Will grounding it out somewhere cause it to blow like that?
@JumpermanTech3 жыл бұрын
You got 5 ohms across one terminal to the other or one terminal to ground? It could def be a possibility. Thanks for watching. Stay safe out there & stay tuned for new videos every week🔧
@techfive72023 жыл бұрын
@@JumpermanTech all 3 terminals tested 5 ohms on resistance across each other. Nothing to ground. 15 ton rtu
@softwarephil17094 ай бұрын
You should use a megger insulation tester like a Fluke 1507.
@JumpermanTech4 ай бұрын
@@softwarephil1709 That one is nice. I'm currently using the Klein Tools ET600. I have made a tutorial on that along with the Supco M500. Thanks for watching! Stay tuned for new videos every week🔧⚡️
@junior74810 Жыл бұрын
Can one of these pumps be converted to single phase? Thank you!
@rajeshparamunsee65326 ай бұрын
Brilliant stuff
@gedyx Жыл бұрын
Hey buddy what should be expected when starting a 3 phase scroll compressor?
@gedyx Жыл бұрын
Low pressure differential or high pressure differential?
@timcordero84538 ай бұрын
Excellent content thank you very much
@Rubensandoval3104 жыл бұрын
Nice explanation
@JumpermanTech3 жыл бұрын
Thank you very much! Appreciate your feedback🙏 Stay safe out there & stay tuned for new videos every week🔧
@sfchannel7643 жыл бұрын
Hello sir, if we want to check winding.. Power suppy need to be on or off?
@nickbarnes93473 жыл бұрын
Off
@MegaIsok3 жыл бұрын
Would you check the amp draw on a compressor to get a more in-depth diagnosis of its condition?
@WillieMakeit2 жыл бұрын
Not if it's shorted. If it works you could check each leg with a megohm meter
@Sc19869 Жыл бұрын
What is a 3 phase compressor and what is a single phase. Appreciate your knowledge and videos. Also when you mean check the compressor for ground, is that a short?
@johnbrewer12349 ай бұрын
OL = Over limit. Good concise video sir
@AlexLopez-rn4ex3 жыл бұрын
On a three phase compressor the windings always read the Same resistance. if the compressor is good.
@DavidBeckett-xz4lh6 ай бұрын
Are the earth and neutral combined.
@Nab-Asn28033 жыл бұрын
Great vedio jumperman tech
@airtechnologygroup17383 жыл бұрын
Thanks for simple explanation.
@JumpermanTech3 жыл бұрын
You're very welcome & thank you! Appreciate the feedback. Stay safe out there & stay tuned for new videos every week🔧
@JacksonAndrews-gn8bk4 жыл бұрын
Save your sandpaper and use that ground wire right on the compressor
@JumpermanTech3 жыл бұрын
Good tip👍 Thanks for watching! Stay safe out there & stay tuned for new videos every week🔧
@robbyclark69153 жыл бұрын
That’s fine but what IF all the windings do NOT read the same resistance? What does that mean? 🤷🏻♂️
@Four_leaf_Lord Жыл бұрын
Depends on if it’s 3 phase or single phase in this instance if he got like a 1.9 the windings would be bad
@mickeylojkar57693 жыл бұрын
So if one winding don’t read the same, isn’t the terminology called shunted windings of the compressor?
@CG-qc1ob2 жыл бұрын
I got resistance only on S+R but not resistance on the other ones
@JumpermanTech2 жыл бұрын
So from C-S & C-S you're getting nothing? Are you getting an O.L reading?
@CG-qc1ob2 жыл бұрын
@@JumpermanTech yes getting LO reading
@JumpermanTech2 жыл бұрын
@@CG-qc1ob You may get an OL reading when the compressor is hot and went off on the internal overload. Check again when the compressor is ambient temperature to confirm but it's looking like a bad compressor so it's time to replace it. Thanks for watching!
@JumpermanTech2 жыл бұрын
@@CG-qc1ob Stay tuned for new videos every week!
@CG-qc1ob2 жыл бұрын
@@JumpermanTech Thanks 😊 I just graduated from trade school. At first unit wasn’t getting any power at all, it was the breaker, then bad capacitor, changed capacitor, everything turned on except the compressor. My diagnose was bad compressor . Thanks for your videos and and respond. I hope you have a video how to turn an ecm motor to psc motor using just relay thanks 🙏🏻 again
@hafizulilmi14764 жыл бұрын
Is there any case there resistances for all windings but inequal?
@JumpermanTech3 жыл бұрын
For 3 phase compressors, that might indicate you have an issue. To go further in depth, use a megohmmeter to test the compressor. I just made a video on that last.Stay safe out there & stay tuned for new videos every week🔧
@ishworibdrniroula21502 жыл бұрын
thank you dear
@zoshimuddin52632 жыл бұрын
Good xpalandt sir
@izzybell114 жыл бұрын
Interesting subject and well explained. Thank you for sharing your experience with us. Good job. ⭐️⭐️⭐️⭐️⭐️
@JumpermanTech3 жыл бұрын
You're very welcome & thank you for sharing your feedback with me🙏 Thanks for watching. Stay safe out there & stay tuned for new videos every week🔧
@qarayen17254 жыл бұрын
Is it possible to test the running using single phase and a capacitor ?
@JumpermanTech3 жыл бұрын
What do you mean exactly by that?
@UltraHydrophobiccoat4 жыл бұрын
Why manufacture 3 phase compressors instead of one phase?
@ridered03cr4 жыл бұрын
3 phase is more for commercial. Though you can do 3 phase for your residential home, I just don’t see why you would really need to. It’s also more expensive. 3 phase compressors draw a lot less current than single phase. So you can achieve the same tonnage with less power. They have much more starting torque as well, meaning you don’t need to run a capacitor or a start capacitor for the compressor to run. They also last longer too. Hope this helps.
@justinwallace3903 жыл бұрын
@@ridered03cr Thank you for that info
@babaolowo353 жыл бұрын
Nice one
@lakhpatsingh64122 жыл бұрын
How to check amps
@justinlynn73153 жыл бұрын
Good video. O.L. is actually Over Limit which means that the value is over the measurable limit. Such as what infinite ohms would be if there is no continuity to ground
@scottshawn702 жыл бұрын
Technically it does not mean “over limit” it means open loop or open line to signify there is no continuity. When checking continuity you are checking if there is a closed path for current.. or if it’s “open”.
@jollyscaria19222 жыл бұрын
Sound ohms showesing good no grunde
@pianduchuance8592 жыл бұрын
Good
@wd85574 жыл бұрын
Next time use a megger and check the insulation.
@JumpermanTech3 жыл бұрын
Great tip👍 Just made a video on that! Appreciate the feedback. Stay safe out there & stay tuned for new videos every week🔧
@jabroski69 Жыл бұрын
Comment
@harryschrysan3183 Жыл бұрын
I have a question. Today I was diagnosing a compressor for a mini split that was making weird noises and after 3-4 seconds it stops on thermal overload. I took the resistance on the 3 terminals and all were the same resistance. But when I was checking each to ground I had continuity. I was buffled because I know a grounded comp trips the breaker but this one would trip the overload plus it would try to start for a few seconds. I read the diagram and it seems to be a star winding configuration. My boss told me that those comps are by default grounded. It's the first time I have seen this. Is it for real? I am questioning my boss's knowledge atm 😅