You can wire those after market motors as a 3 wire or 4 wire motor. There is no need to pull an extra conductor
@TheSoundmanPete2 ай бұрын
Exactly. Typically white and white/brown is connected internally. Cap the white/brown wire off.
@hosseinovisi98653 ай бұрын
You could install the fan blades to other sides, so you could tight the set screws easier, because the motors are reversible.
@JesseDoesHVAC3 ай бұрын
Back baby! You gotta leave a bag of tools inside each of these units my dude, you there all the time
@BLUE_COLLAR_REFER3 ай бұрын
Done these many time. Remove old motor install the new without the blade so it’s easier to fasten. Then once motor is tight you adjust the blade to proper height. Also you only need 3 wires on all universal motors, cap the brown with white stripe and leave cap where it is.
@DonJose863 ай бұрын
When you know u know
@TomHyatt-i7z3 ай бұрын
Tip. When you have the fan blade up that high on shaft take Chanel locks on bottom of shaft and spin blade off. ❤
@av78093 ай бұрын
I had to do that when I forgot my hub puller once. An old tech told me to try it.
@hkhsm3593 ай бұрын
Nice to see Jumper Man doing back to KZbin. Thanks for sharing. 🎉🎉🎉
@gordonpotts7533 ай бұрын
That was a high wire act. Nice work.
@moutrap3 ай бұрын
You make it look so easy, good work
@scottmaz40633 ай бұрын
Another job well done by JMT
@pewpeww5563 ай бұрын
Are those fan blades up side down? Usually I leave the set screws up top and configure the motor rotation to match. Love your vids bro. The stuff you deal with in nyc is wild.
@nickc63993 ай бұрын
They are upside down
@blancoz90003 ай бұрын
All condenser fan blades are installed upside down, he could’ve flipped the blade and switched rotation on the wire to change rotation of the blade to make it easier for him or the next guy after
@australianfridgie44693 ай бұрын
@@blancoz9000 blades are curved would lose airflow
@mxslick503 ай бұрын
With the old wires having failed once before, running all new wire was a good idea. But........on those new motors, the white and white/brown wires are electrically the same. The note on the label right below the diagram on the motor shows that. So you could have left the old wiring in use, by connecting as follows: Black to black, Brown to Brown, and the white plus white brow to the yellow. The end result would be electrically the same.
@Hvacnc3 ай бұрын
Thought the brown/white could be capped off and not used… so it has to go along with the white and the yellow( in this scenario)
@mxslick503 ай бұрын
@@Hvacnc Depends on the motor actually. I'd say most of them you can indeed cap off the white/brown, but it doesn't hurt to tie it and the white together. A simple test to verify is use your meter between white and white brown. If the reading is zero ohms (or whatever your meter reads when you touch the leads together when checking the meter itself) , you can cap it off. If it is anything other than zero, best to tie them together.
@Hvacnc3 ай бұрын
@@mxslick50 thanks
@thesilentonevictor3 ай бұрын
Another one for the books chris is a good pilot to have
@JohnDoe-ej1lw3 ай бұрын
Clean, neat job! You the man! JMT
@stevencossaboon32373 ай бұрын
Nice work Jumper Man.
@chrissmith5133 ай бұрын
Thank goodness you have those pullers !!! 😊😊😊 Yes cut that axle
@zekenzy64863 ай бұрын
Great video. Thank you for sharing
@Shawn_RHVAC2 ай бұрын
Use a 1/4” extension in your rachet set. Use the end that would attach to the rachet and place over the square screw head. Use wrench on the opposite end and loosen. Or tighten.
@hmrody3 ай бұрын
In my experience, and if the customer allows, it is much preferable to replace the fan blade as well. I would think that much force from your puller would deform the blade assembly, resulting in vibration and premature failure of the motor. But, sometimes you have to do what you have to do... Regrettably.
@hmrody3 ай бұрын
I also reuse the rain slinger and make sure the top weep hole is plugged and the bottom weep hole plug removed... Just some arm chair suggestions.
@tacydit3 ай бұрын
There are some things he's not very smart 😕 on.
@HVACR5592 ай бұрын
12 pt 3/8 works on those square screws. Usually use my open ens box end wrench
@alexz77353 ай бұрын
On these types of units, I've come across to were the new CFM gets hooked up with 2 capacitors mistakenly. What I do is cut off the brown/white wire on the new motor and isolate it.
@TheSoundmanPete2 ай бұрын
Good quality 12 point sockets can be used on square head bolts/screws. PB Blaster is a better rust breaker choice.
@djdaex3 ай бұрын
is all time old stuff fun lol we have go true some time good job
@matthewcarello92803 ай бұрын
You can drop the brown with the white stripe and run the 3 wires to a dual cap whit black and brown. The brown with white stripe is internally jumped as if on the common. If u don't use the brown with the white strip you just need a dual cap with the c.
@thesilentonevictor3 ай бұрын
Man this building is your favorite i guess keeps your on your feet
@austinkraus7563 ай бұрын
Service wrench will get those lock in nuts off those
@jasonjohnsonHVAC3 ай бұрын
99% of the time I also replace the fan blade as well....when I don't and they are being a pain like it was for you......use your channel locks behind the blade by the motor.....grab the shaft with one hand....the other hand you spin the fan blade....it'll break loose and you can get the blade off the shaft.
@timshields53083 ай бұрын
you could have saved alot of tiime by wiring it with 3 wire instead of 4 wire, usually tells you on motor diagram both ways. or just used oem an would have been a quick swap. atleast you didint let cap hang down under motor, witch i see to often. nice job overall, you just made it a little harder on your self
@franks68373 ай бұрын
You're ac service wrench should be able to take the shaft set screws out same as on blower wheels
@davidjohnson94383 ай бұрын
I WOULD A BEEN TERRIFIED OF THAT HEIGHT 😳
@demorteparkinson60143 ай бұрын
How can I go on one these missions with you ?
@easterdayryan3 ай бұрын
leave the blade off until last makes everything easier.
@donaldkenney26482 ай бұрын
Get a hub puller brother 😮😮
@jayred37773 ай бұрын
By the time u get the blade off it would have been better to get a new fan ! Less frustrating and faster ? Ps use a small socket that will fit through the hole !
@DonJose863 ай бұрын
Everydollar counts, if your charging by billable hours take your time also good practice to show your helper how to get busy
@av78093 ай бұрын
I think he mentioned his van got broken into and tools stolen. But I’ve also had some where the nut is too close to the bracket so I couldn’t fit a socket. Had to use a small wrench.
@australianfridgie44693 ай бұрын
should’ve just swapped a motor and blade from circuit not working. if they decide to replace/repair evaporator then put a new oem in then
@nickc63993 ай бұрын
Could’ve just cut the brown/white wire it’s essentially the same wire as brown and could’ve just wired it back the way it was and not needed to do all the extra work.
@richardbartlett6932Ай бұрын
fan blades are set too low. not set correctly so not pulling enough air through.
@ILoveKittys783 ай бұрын
😻💚💜💚
@JumpermanTech3 ай бұрын
@@ILoveKittys78 💜🔧⚡️
@perryseidler4343 ай бұрын
That pulley is not for condenser fan blade can bust the fan hub
@JesseDoesHVAC3 ай бұрын
It didnt but
@bonexsher3 ай бұрын
I cringe when you put your tools on top of condenser waiting for it to start 🥴
@loramurray79543 ай бұрын
Why not go OEM?
@johnwalker8903 ай бұрын
You're missing a Two pole contactor for the condenser fans, on that circuit, it shouldn't be doubled up on the compressor contactor..........
@DonJose863 ай бұрын
O really obviously u don't know shit that's how ALOT of units are shipped from the factory
@HVACR5592 ай бұрын
The condenser fan grabs 2 legs from the 3 pole contactor to the compressor, there's nothing wrong with that. A little strange for 2 motors to share 1 capacitor.