HVAC: York RTU Not Cooling Properly/Overheating (York RTU High Head Pressure Troubleshooting/Repair)

  Рет қаралды 8,447

Jumper man Tech

Jumper man Tech

Күн бұрын

HVAC: York RTU Not Cooling Properly/Overheating (York RTU High Head Pressure Troubleshooting/Repair) HVAC (Heating, Ventilation, Air Conditioning) York RTU Not Cooling Follow Up & 1 of 2 Circuits Down (York Packaged RTU Troubleshooting) HVAC: York RTU Not Cooling Properly (York Packaged Roof Top Unit Troubleshooting And Repair) HVAC Service Call: York RTU Low Superheat High Subcooling (Rooftop Package Unit High Head Pressure) HVAC Service Call: York RTU Not Cooling (Package Unit Air Flow Issues) Low Superheat/High Subcooling / York RTU Not Cooling /York RTU Not Heating / York RTU No Heat / York RTU No Cool / HVAC Troubleshooting / AC Air Flow Troubleshooting / How To Clean Condenser Coil / How To Clean Evaporator Coil / How To Clean Air Conditioner Coils For Air Conditioning & Refrigeration Systems #HVAC #RTU #jumpermantech
RTU stands for rooftop unit, and it's a type of HVAC system that's mounted on a building's roof to provide heating, ventilation, and air conditioning. RTUs are also known as packaged systems because all the necessary components, like the compressor, coils, and fans, are contained in one unit.
RTUs are often used in commercial and industrial facilities to heat and cool large areas. They can be water-cooled or fan-cooled, and can produce heat using gas, electricity, or water. The unit uses ductwork to circulate conditioned air throughout the building.
GoPro HERO8 Black (Camera Used In This Video)
amzn.to/3q4FmEz
Veto Pro Pac TECH MC
amzn.to/3gURJyZ
Fluke 902 FC HVAC True-RMS Clamp Meter
amzn.to/39wvwiK​​
Fieldpiece ADK7 Deluxe Silicone Test Lead Kit
amzn.to/3VNYXDv
Klein Tools ET600 Megohmmeter Insulation Tester
amzn.to/409iNvu
Supco M500 Insulation Tester/Electronic Megohmmeter
amzn.to/42oy0ua
Fluke 1AC-A1-II VoltAlert Non-Contact Voltage Tester
amzn.to/3FcWElQ
Yellow Jacket 77930 Oil Pump
amzn.to/45k9j4i
Lenovo Tablet M9
amzn.to/3Re2Qlh
Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
amzn.to/3E4W0Fr
Fieldpiece SPK2 Folding Pocket In-Duct Thermometer
amzn.to/3mi8Fih
Fieldpiece SPK3 Folding ROD Dual Temperature Thermometer
amzn.to/3FbDufQ
Milwaukee M12 2-Tool Combo Kit 2598-22
amzn.to/3CtCRNC
Milwaukee Cut 1 Dipped GLOVES L
amzn.to/3s8H18O​
Milwaukee 2351-20 M12 LED Stick Light
amzn.to/3rVJKEK
Milwaukee 48-22-1985 Fastback Hawk Bill Folding Knife
amzn.to/3e53ygW
Milwaukee 48-22-1500 Fastback Compact Folding Utility Knife
amzn.to/3qazJkC
Milwaukee 48-22-4041 Iron Carbide Core Large-Looped Jobsite Scissors
amzn.to/32fxC6I
Milwaukee 4932459097 Billet Torpedo Level
amzn.to/30Dh6Nw
Milwaukee Wide Blade Magnetic Tape Measure 16 FT
amzn.to/3yEN7kL
Milwaukee Fine Pt. Markers Black
amzn.to/3e4fH5W
Streamlight 66604 MicroStream USB 250-Lumen Rechargable Pocket Flashlight
amzn.to/320XiEF
Klein Tools 11-in-1 Screwdriver / Nut Driver
amzn.to/3s3o8ql
Klein Tools 32561 Multi-Bit Screwdriver / Nut Driver 6-in-1
amzn.to/3e4ur4x
Klein Tools 32807MAG 7-in-1 Nut Driver, Magnetic Driver
amzn.to/321n4bW
Klein Tools 600-4 1/4-Inch Keystone Cushion-Grip Screwdriver
amzn.to/3J11hS1
Klein Tools 32581 4-in-1 Electronics Screwdriver Set
amzn.to/3yEj3WC
Klein Tools LLK12 L-Style Hex Key Caddy Set 12-Piece (Metric/Sae)
amzn.to/3yRUiGJ
Yellow Jacket 18975 Charge Tool
amzn.to/3J4pfvJ
Yellow Jacket 60613 Service ratchet Wrench
amzn.to/3E8iYeZ
Yellow Jacket 19173 5/16" Female Quick Couplers x 1/4" Male Flare
amzn.to/3q0TQ4M
Cooper Bussmann BP-FP-2 Cartridge Carded Fuse Puller
amzn.to/3e0USrY
Crescent 2 Pc. X6 4-in-1 Black Oxide Spline Ratcheting SAE Wrench Set
amzn.to/3qqKlw7
Crescent 4" Adjustable Cushion Grip Wrench
amzn.to/3J4qsmL
Knipex 09 08 240 SBA 9.5-Inch Insulated Ultra-High Leverage Lineman's Pliers (1000v)
amzn.to/30EQmw5
Knipex 09 11 240 9.5-Inch Ultra-High Leverage Lineman's Pliers with Fish Tape Puller and Crimper
amzn.to/3H9iYAu
KNIPEX Tools - Long Nose Pliers With Cutter, 1000V Insulated
amzn.to/3e3IEi7
KNIPEX Tools - Long Nose Pliers With Cutter
amzn.to/3gUSE2i
KNIPEX Tools 98 62 02, Flat Nose Plastic Pliers 1000V Insulated
amzn.to/3p6lFsZ
KNIPEX - 74 08 200 - High Leverage Diagonal Cutters, 1000V Insulated
amzn.to/3mh8K5U
KNIPEX - 74 01 200 Tools - High Leverage Diagonal Cutters
amzn.to/3F1VScb
KNIPEX Tools - Cobra QuickSet Pump Pliers, 1000V Insulated
amzn.to/3sftr5Q
KNIPEX Tools 3 Piece Cobra Pliers Set
amzn.to/3FbRwy7
KNIPEX Tools Pliers Wrench 3-Piece Set
amzn.to/3nnRLfW

Пікірлер: 57
@nonamesplease8228
@nonamesplease8228 Ай бұрын
You can wire those after market motors as a 3 wire or 4 wire motor. There is no need to pull an extra conductor
@TheSoundmanPete
@TheSoundmanPete 12 күн бұрын
Exactly. Typically white and white/brown is connected internally. Cap the white/brown wire off.
@hosseinovisi9865
@hosseinovisi9865 Ай бұрын
You could install the fan blades to other sides, so you could tight the set screws easier, because the motors are reversible.
@user-lq3hq1vp5q
@user-lq3hq1vp5q Ай бұрын
Tip. When you have the fan blade up that high on shaft take Chanel locks on bottom of shaft and spin blade off. ❤
@av7809
@av7809 Ай бұрын
I had to do that when I forgot my hub puller once. An old tech told me to try it.
@JesseDoesHVAC
@JesseDoesHVAC Ай бұрын
Back baby! You gotta leave a bag of tools inside each of these units my dude, you there all the time
@mxslick50
@mxslick50 Ай бұрын
With the old wires having failed once before, running all new wire was a good idea. But........on those new motors, the white and white/brown wires are electrically the same. The note on the label right below the diagram on the motor shows that. So you could have left the old wiring in use, by connecting as follows: Black to black, Brown to Brown, and the white plus white brow to the yellow. The end result would be electrically the same.
@Hvacnc
@Hvacnc Ай бұрын
Thought the brown/white could be capped off and not used… so it has to go along with the white and the yellow( in this scenario)
@mxslick50
@mxslick50 Ай бұрын
@@Hvacnc Depends on the motor actually. I'd say most of them you can indeed cap off the white/brown, but it doesn't hurt to tie it and the white together. A simple test to verify is use your meter between white and white brown. If the reading is zero ohms (or whatever your meter reads when you touch the leads together when checking the meter itself) , you can cap it off. If it is anything other than zero, best to tie them together.
@Hvacnc
@Hvacnc Ай бұрын
@@mxslick50 thanks
@hkhsm359
@hkhsm359 Ай бұрын
Nice to see Jumper Man doing back to KZbin. Thanks for sharing. 🎉🎉🎉
@alexz7735
@alexz7735 Ай бұрын
On these types of units, I've come across to were the new CFM gets hooked up with 2 capacitors mistakenly. What I do is cut off the brown/white wire on the new motor and isolate it.
@jayredhead3777
@jayredhead3777 Ай бұрын
By the time u get the blade off it would have been better to get a new fan ! Less frustrating and faster ? Ps use a small socket that will fit through the hole !
@DonJose86
@DonJose86 Ай бұрын
Everydollar counts, if your charging by billable hours take your time also good practice to show your helper how to get busy
@av7809
@av7809 Ай бұрын
I think he mentioned his van got broken into and tools stolen. But I’ve also had some where the nut is too close to the bracket so I couldn’t fit a socket. Had to use a small wrench.
@BLUE_COLLAR_REFER
@BLUE_COLLAR_REFER Ай бұрын
Done these many time. Remove old motor install the new without the blade so it’s easier to fasten. Then once motor is tight you adjust the blade to proper height. Also you only need 3 wires on all universal motors, cap the brown with white stripe and leave cap where it is.
@DonJose86
@DonJose86 Ай бұрын
When you know u know
@Shawn_RHVAC
@Shawn_RHVAC 23 күн бұрын
Use a 1/4” extension in your rachet set. Use the end that would attach to the rachet and place over the square screw head. Use wrench on the opposite end and loosen. Or tighten.
@pewpeww556
@pewpeww556 Ай бұрын
Are those fan blades up side down? Usually I leave the set screws up top and configure the motor rotation to match. Love your vids bro. The stuff you deal with in nyc is wild.
@nickc6399
@nickc6399 Ай бұрын
They are upside down
@blancoz9000
@blancoz9000 Ай бұрын
All condenser fan blades are installed upside down, he could’ve flipped the blade and switched rotation on the wire to change rotation of the blade to make it easier for him or the next guy after
@australianfridgie4469
@australianfridgie4469 Ай бұрын
@@blancoz9000 blades are curved would lose airflow
@gordonpotts753
@gordonpotts753 Ай бұрын
That was a high wire act. Nice work.
@MarkCarpenterHVAC-me2jg
@MarkCarpenterHVAC-me2jg 11 күн бұрын
12 pt 3/8 works on those square screws. Usually use my open ens box end wrench
@austinkraus756
@austinkraus756 Ай бұрын
Service wrench will get those lock in nuts off those
@TheSoundmanPete
@TheSoundmanPete 12 күн бұрын
Good quality 12 point sockets can be used on square head bolts/screws. PB Blaster is a better rust breaker choice.
@thesilentonevictor
@thesilentonevictor Ай бұрын
Another one for the books chris is a good pilot to have
@scottmaz4063
@scottmaz4063 Ай бұрын
Another job well done by JMT
@chrissmith513
@chrissmith513 Ай бұрын
Thank goodness you have those pullers !!! 😊😊😊 Yes cut that axle
@moutrap
@moutrap Ай бұрын
You make it look so easy, good work
@hmrody
@hmrody Ай бұрын
In my experience, and if the customer allows, it is much preferable to replace the fan blade as well. I would think that much force from your puller would deform the blade assembly, resulting in vibration and premature failure of the motor. But, sometimes you have to do what you have to do... Regrettably.
@hmrody
@hmrody Ай бұрын
I also reuse the rain slinger and make sure the top weep hole is plugged and the bottom weep hole plug removed... Just some arm chair suggestions.
@tacydit
@tacydit Ай бұрын
There are some things he's not very smart 😕 on.
@matthewcarello9280
@matthewcarello9280 Ай бұрын
You can drop the brown with the white stripe and run the 3 wires to a dual cap whit black and brown. The brown with white stripe is internally jumped as if on the common. If u don't use the brown with the white strip you just need a dual cap with the c.
@davidjohnson9438
@davidjohnson9438 28 күн бұрын
I WOULD A BEEN TERRIFIED OF THAT HEIGHT 😳
@JohnDoe-ej1lw
@JohnDoe-ej1lw Ай бұрын
Clean, neat job! You the man! JMT
@stevencossaboon3237
@stevencossaboon3237 Ай бұрын
Nice work Jumper Man.
@franks6837
@franks6837 Ай бұрын
You're ac service wrench should be able to take the shaft set screws out same as on blower wheels
@thesilentonevictor
@thesilentonevictor Ай бұрын
Man this building is your favorite i guess keeps your on your feet
@zekenzy6486
@zekenzy6486 Ай бұрын
Great video. Thank you for sharing
@djdaex
@djdaex Ай бұрын
is all time old stuff fun lol we have go true some time good job
@timshields5308
@timshields5308 Ай бұрын
you could have saved alot of tiime by wiring it with 3 wire instead of 4 wire, usually tells you on motor diagram both ways. or just used oem an would have been a quick swap. atleast you didint let cap hang down under motor, witch i see to often. nice job overall, you just made it a little harder on your self
@jasonjohnsonHVAC
@jasonjohnsonHVAC Ай бұрын
99% of the time I also replace the fan blade as well....when I don't and they are being a pain like it was for you......use your channel locks behind the blade by the motor.....grab the shaft with one hand....the other hand you spin the fan blade....it'll break loose and you can get the blade off the shaft.
@easterdayryan
@easterdayryan Ай бұрын
leave the blade off until last makes everything easier.
@donaldkenney2648
@donaldkenney2648 25 күн бұрын
Get a hub puller brother 😮😮
@australianfridgie4469
@australianfridgie4469 Ай бұрын
should’ve just swapped a motor and blade from circuit not working. if they decide to replace/repair evaporator then put a new oem in then
@demorteparkinson6014
@demorteparkinson6014 Ай бұрын
How can I go on one these missions with you ?
@nickc6399
@nickc6399 Ай бұрын
Could’ve just cut the brown/white wire it’s essentially the same wire as brown and could’ve just wired it back the way it was and not needed to do all the extra work.
@perryseidler434
@perryseidler434 Ай бұрын
That pulley is not for condenser fan blade can bust the fan hub
@JesseDoesHVAC
@JesseDoesHVAC Ай бұрын
It didnt but
@ILoveKittys78
@ILoveKittys78 Ай бұрын
😻💚💜💚
@JumpermanTech
@JumpermanTech Ай бұрын
@@ILoveKittys78 💜🔧⚡️
@bonexsher
@bonexsher Ай бұрын
I cringe when you put your tools on top of condenser waiting for it to start 🥴
@loramurray7954
@loramurray7954 Ай бұрын
Why not go OEM?
@johnwalker890
@johnwalker890 Ай бұрын
You're missing a Two pole contactor for the condenser fans, on that circuit, it shouldn't be doubled up on the compressor contactor..........
@DonJose86
@DonJose86 Ай бұрын
O really obviously u don't know shit that's how ALOT of units are shipped from the factory
@MarkCarpenterHVAC-me2jg
@MarkCarpenterHVAC-me2jg 11 күн бұрын
The condenser fan grabs 2 legs from the 3 pole contactor to the compressor, there's nothing wrong with that. A little strange for 2 motors to share 1 capacitor.
English or Spanish 🤣
00:16
GL Show
Рет қаралды 14 МЛН
مسبح السرير #قصير
00:19
سكتشات وحركات
Рет қаралды 11 МЛН
So Cute 🥰
00:17
dednahype
Рет қаралды 43 МЛН
Magic or …? 😱 reveal video on profile 🫢
00:14
Andrey Grechka
Рет қаралды 52 МЛН
Customer Fired Other Company! Can I Figure This No Cooling Out?
18:25
Jeff’s HVAC Adventures
Рет қаралды 365 М.
How a Supermarket Refrigeration System Works
8:45
HVACR Career Connect NY
Рет қаралды 62 М.
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 258 М.
More Mistakes More Problems New Install Failures
33:14
HVACR Survival
Рет қаралды 26 М.
THIS TRANE SPACESHIP JUST STOPPED WORKING
25:51
HVACR VIDEOS
Рет қаралды 62 М.
Unit Still Has The Original 1978 TXV
19:32
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 7 М.
Как почистить AirPods Max
0:57
Romancev768
Рет қаралды 648 М.
Which phone do you have?
0:33
Adhemz
Рет қаралды 1,6 МЛН
МУЖИЦКИЙ КОМП
1:00
VA-PC
Рет қаралды 359 М.
Как настроить камеру хоп-ап
1:00
TimToker
Рет қаралды 3,9 МЛН