Generator Won't start? Generac Service Made Easy!

  Рет қаралды 24,847

HVACR Survival

HVACR Survival

Күн бұрын

Пікірлер: 125
@spacecadet9983
@spacecadet9983 3 ай бұрын
My Dad had a generac installed in 2021. I will be aquiring the house. This is great info, i will be back for a refresher
@HVACRSurvival
@HVACRSurvival 3 ай бұрын
Cool. I hope it helps
@karlschwab6437
@karlschwab6437 Жыл бұрын
This is great! Last October, we had a Generac 14kw installed at our cottage in northern Michigan. The operation of this generator is reporting back to us via WiFi and we are not there this winter to look in on it, but it is keeping the cottage powered when we loose power so frequently. It is important for us to be able to understand how the generator works and what we can do to maintain it. Thanks for all your home standby generator videos.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Your welcome👍👍
@cjsalzman1000
@cjsalzman1000 3 ай бұрын
Very helpful for this newbie owner. Thank you and God bless.
@richardrumplik7023
@richardrumplik7023 Ай бұрын
Well done, I was looking for a no crank issue and I’ve been doing all my maintenance since it was installed in 2003 . I already replaced the starter about 10years ago. I was hoping it was the solenoid this time👍
@nathanhurst5155
@nathanhurst5155 Жыл бұрын
Wonderful video Rick. It’s a good thing for homeowners to know how to do basic maintenance on everything. Good explanations of what your were doing and why👍
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks so much Nathan!
@mwrcrft
@mwrcrft Жыл бұрын
Great video for home owner level maintenance. I just bought a 7.5 Kw unit and the motor looks to be half of the two cylinder model and the crank rides on roller bearings not like bushings that a lot of motors have gone to, The form a funnel will be a good thing to have.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks !
@jeffsignore7953
@jeffsignore7953 Жыл бұрын
First let me say you’re great. Love watching your videos, learn so much from you and have the utmost respect for you. Not sure if I would have even touched that generator because it’s a liability issue. Windows are way to close to the generator. Generac recommends 5’ from any window, door or air intake and 3’ working clearance on sides and front.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
I said a lot of things that I cut out. I agree, there were several things that weren't correct.
@jeffsignore7953
@jeffsignore7953 Жыл бұрын
@@HVACRSurvival yeah I already know that you knew that. You’re way to smart to not know! I appreciate you sharing your knowledge. I learn a lot from you! Thanks for all you do!
@bladerunner1458
@bladerunner1458 Жыл бұрын
Thank you for the maintenance review and tips. My 2003 unit is in Northern Michigan. From previous videos U have given me a very clear understanding how these things operate and their issues. I do all my maintenance myself since I’m a very remote farm. For survival I have to be self reliant and I’m well trained technician and engineer. Fortunately, I don’t have any critical loads (home is super insulated) that need to be attended too so I will operate the generator manually (once a day) for larger loads, and to charge a battery with inverter used for light loads during an outage. Plan to add a solar system in the future. Looks like at the end of the video U may have left the quart oil bottle in the generator compartment since you’re working with the camera. Great explanation of all the details involved with important safety notifications.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
I leave the oil for the owner, because it's an air cooled motor it will naturally burn more oil than a liquid cooled motor. I'm doing a review on a solar generator real soon. It's 3600 watts RMS and 6000 peak, I also have a 400 watt solar panel to charge it. This sounds about what you'll need. I ran the whole house with it, the only issue is you need to use power management if you want it to last. It has a 3600whr battery, the load test showed it tested at the listed rating when l tested it with a continuous 1200 watt load, it lasted about 2.1 to 2.5 HR. I did a review on a smaller solar generator a few months back that was 1200watts rms, with a 9xx watt hr battery. It did fairly well too.
@garypoplin4599
@garypoplin4599 Жыл бұрын
14:49 - Another way to avoid the ‘klunk, klunk, klunks’ is to use it the way the bottle was designed to be used which is to pour with the spout in the highest position.
@Mike_Grant
@Mike_Grant 10 ай бұрын
I have an older generac generator and it is so hard to find good qualified repair techs. Just found your channel and lots of great info. Not sure if you noticed but you left the empty oil container in the generator.
@HVACRSurvival
@HVACRSurvival 10 ай бұрын
Negative, that has a little bit of oil left in it so when they check the oil and it’s low, they can add some to it and it lets them know exactly what type of oil has been used because people tend not to listen when you tell them.
@kevinmarchini5272
@kevinmarchini5272 Жыл бұрын
It really helps to have it hot with the air filter it softens up those back clips especially in cold weather less chance of it breaking do to brittleness good video
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks Kevin! 🤜🤛
@kevinmarchini5272
@kevinmarchini5272 Жыл бұрын
@@HVACRSurvival 👍
@DieterMe
@DieterMe Жыл бұрын
A 2 zylinder 1 Liter combustion engine is not a hack and made simple and cheap. Nice Video.
@gray8797
@gray8797 8 ай бұрын
Great video!!! Very helpful. BTW I think you left the oil container inside the generator. Hope no damage done.
@HVACRSurvival
@HVACRSurvival 8 ай бұрын
I did! I leave that so the customer has some to add when it goes low and they will know what they need.
@FPHA697
@FPHA697 Жыл бұрын
Great job. Everyone can tell your not a half ass tech very thorough on you job. This hvacr industry needs more folks like you.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks Brother!
@CajunReaper95
@CajunReaper95 8 ай бұрын
I mean it’s pretty half assed to take things off the generator and not put them back on and say oh well the next guy might have some in his bag or carry them is it hard to put things back on after taking them off??
@FPHA697
@FPHA697 8 ай бұрын
@@CajunReaper95 talking about the bracket
@Eddy63
@Eddy63 Жыл бұрын
Very thorough training session Rickster ... Interesting as well ... Thank you Sir ...
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Glad you enjoyed it!
@VE3NMW
@VE3NMW Жыл бұрын
I like your honesty on things!!
@HVACRSurvival
@HVACRSurvival Жыл бұрын
🙂👍👍 thank you, it's gotten me in trouble since I was a kid 🙂
@davidaustin9009
@davidaustin9009 Жыл бұрын
Great training
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks 👍
@dsonyay
@dsonyay Ай бұрын
Very good tutorial :)
@HVACRSurvival
@HVACRSurvival Ай бұрын
Thank you very much!
@marvinmoore5315
@marvinmoore5315 12 күн бұрын
I have a 24kw 200 amp generac but looks just like the one in the video. It is saying RPM sensor. It does buzz (the rpm sensor) so I guess I should see about putting a multi meter on it. However the battery I’m using isn’t really anything and not sufficient CCA. So should I just try a battery first? I picked it up for $500 was thinking I could put a little work in it and make some $. Let me know what you think
@HVACRSurvival
@HVACRSurvival 12 күн бұрын
Speed helps with the pick up voltage but there are a few different things that can cause it. It takes several tests and steps to figure it out.
@ThomasMarcotte-jt9od
@ThomasMarcotte-jt9od Жыл бұрын
Thanks. Great video.
@Ted_E_Bear
@Ted_E_Bear Жыл бұрын
Rick, Thank you for sharing your knowledge with us as dumb owners don’t know what to do ! Keep up the amazing work !
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks Bear!
@marvinsellers4457
@marvinsellers4457 Жыл бұрын
Hey Hoss that was very informative I really enjoyed that and I don’t even have a generator a lot of good information.! Have a great week
@HVACRSurvival
@HVACRSurvival Жыл бұрын
@Marvin thanks man! I really appreciated hearing that! 🤜🤛👍👍
@DrMGomezJr
@DrMGomezJr 9 ай бұрын
Nice little sermon...
@zekenzy6486
@zekenzy6486 11 ай бұрын
Great Video. Thank you for sharing
@jakepeoples9238
@jakepeoples9238 8 ай бұрын
I love these videos! keep em coming! awesome information!
@HVACRSurvival
@HVACRSurvival 8 ай бұрын
Thanks! Will do!
@jeremywalker1668
@jeremywalker1668 Жыл бұрын
You DA MAN!!
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
Good stuff Rick
@anthonymarino4260
@anthonymarino4260 8 ай бұрын
WELL DONE THANKS FOR SHARING
@HVACRSurvival
@HVACRSurvival 8 ай бұрын
No problem 👍👍
@xiaoboliu4377
@xiaoboliu4377 Жыл бұрын
Great video! I am learning about this type of generator just by looking at your videos! The tech support line of Generac is not that helpful! One question to you and everyone, I inherit a Generac generator from the previous owner, the battery currently connected is a 34 battery but the manual says this generator needs a 26R battery. Is this mean the 34 battery is useless to me and could cause damage to the unit? Please advise! Thank you so much!
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Having at least 525 cold cranking amps for most air-cooled generators is the most important thing, the number you're referring to is the physical size of the battery and the dimensions.
@xiaoboliu4377
@xiaoboliu4377 Жыл бұрын
@@HVACRSurvival Thank you so much boss! Understand! Salute!
@aitutaki98
@aitutaki98 8 ай бұрын
Great video!
@jayfowler4747
@jayfowler4747 Жыл бұрын
Cue the putting contaminants into the filter arguments......
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Isn't that what the oil filter is for? To catch the contaminants LOL it's not like this thing's hydroscopic
@jayfowler4747
@jayfowler4747 Жыл бұрын
@@HVACRSurvival apparently the oil enters the small holes and comes out the center so pouring oil could put particles after the filter...I always thought the oil went the other way and always filled em up as you did so I just oil the seal and fit it empty. I think the oil moves so fast its not a big deal these days...
@HVACRSurvival
@HVACRSurvival Жыл бұрын
If the oil is brand new and the oil filter is brand new, then if there are contaminants in there, it's probably from the oil filter. Even then worst case scenario to catch it on the other side of the filter as it circulates through. I don't necessarily think filling the oil filter in advance is that big of a deal either but it's just something that made sense so I just started doing it.
@jayfowler4747
@jayfowler4747 Жыл бұрын
@@HVACRSurvival my thoughts too but if you let a mechanic see you do that you can set em off... especially if they are by the book mechanics....they say all you need is a tiny particle to destroy the crank journal...
@slvlt69
@slvlt69 Жыл бұрын
@hvacrsurvival I just bought a home and it comes with a 20kw generac generator. I just followed the steps and changed the brand new battery, oil change, filter change, and new spark plugs (the whole package came together). But my generator just cranked couple times but no start at all. What could be the problem? Thanks I’m advance.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
To many possibilities, Take it back and exchange it is what I would do if you just bought it.
@JohnWilson-greytyphoon
@JohnWilson-greytyphoon 2 ай бұрын
Is it ok to leave an oil container in the cabinet to top off
@HVACRSurvival
@HVACRSurvival 2 ай бұрын
That’s what I do
@HVACGUY
@HVACGUY Жыл бұрын
Love the generator videos
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks for checking it out!
@dougking7592
@dougking7592 Жыл бұрын
Nice job brother as always
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Much appreciated👍
@dougking7592
@dougking7592 Жыл бұрын
👍🏻
@dougking7592
@dougking7592 Жыл бұрын
👍🏻
@dthreatt
@dthreatt Ай бұрын
Great video. I learned alot from you looking at all your videos. You left a bottle of oil in there though. LOL :)
@HVACRSurvival
@HVACRSurvival Ай бұрын
I do that on purpose so the customer knows what brand and type of oil they need plus, it usually has a small amount of oil left in there to get them by until they get more. I appreciate you letting me know that you’re getting something out of them. It means a lot.
@miketaggart3803
@miketaggart3803 3 ай бұрын
Noticed that the genny was next to a window. Isn’t that a code violation? I had one put in and was told the genny had to be at least 6’ from any windows so CO won’t enter the house
@Shuffler703
@Shuffler703 9 ай бұрын
Where did you get that Pennzoil? I have not even seen it on the market. My 24kw Generac is close to it's schedule A. I am in a warmer climate and the maintenance pack from Generac has 5w-20 in it.
@HVACRSurvival
@HVACRSurvival 9 ай бұрын
From a local supplier.
@thonatim5321
@thonatim5321 12 күн бұрын
Is there a better generator then Generac? I see there are many problems but I do not know if other brands are worse.
@HVACRSurvival
@HVACRSurvival 12 күн бұрын
I like Kohler but Generac are better than they were.
@thonatim5321
@thonatim5321 12 күн бұрын
@@HVACRSurvival Thanks. You have a new sub.
@jimokeefe6392
@jimokeefe6392 Ай бұрын
can you tell me what causes the stators for fail
@HVACRSurvival
@HVACRSurvival Ай бұрын
It really depends, dirt can cause major issues if it’s running, the vibration of the dirt in the windings can cause it to eat through the insulation. Another possibility is getting degreaser or some sort of chemical like battery acid in the windings or over loading the generator.
@marktomlinson3448
@marktomlinson3448 Жыл бұрын
Correction: Your battery tester is showing milliohms, not megohms. Milli is 1/1000, mega is 1 million!
@mikerossman9863
@mikerossman9863 7 ай бұрын
250000 kw generator??? Like to see the size of it! I’ve done work as a CM in the navy and worked on a lot of 400 kw gens, about the size of a short shipping container. 200 kw were the size of a van. Of corse this is the entire unit as a whole, fuel tank and all. But a 250000 kw must be massive 🤷🏻‍♂️
@HVACRSurvival
@HVACRSurvival 7 ай бұрын
Sorry. I misspoke. 250kw.
@mikerossman9863
@mikerossman9863 7 ай бұрын
@@HVACRSurvival I thought so, all good…. I had to rewind it a few times to make sure I heard what I heard. Just curious if the Hoover damn could produce 250000 kw lol, I’m sure at that point it’s in the mega watts.
@Boodieman72
@Boodieman72 Жыл бұрын
I use a vacuum extractor to remove the oil on everything, zero mess.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Getting oil out of a generator that is below grade can be a challenge.
@Boodieman72
@Boodieman72 Жыл бұрын
@@HVACRSurvival Get yourself a fluid extractor.
@tbelding
@tbelding Жыл бұрын
Those generally won't help much on the filter. I've pumped fluid out of a transmission that way, rather than pull the diaper off of an engine, but I do prefer draining it using gravity.
@Boodieman72
@Boodieman72 Жыл бұрын
@@tbelding Never mentioned anything about the filter. I prefer fluid extracttion as more fluid is removed.
@tbelding
@tbelding Жыл бұрын
@@Boodieman72 - Assumed you included the filter because that's usually the messiest part. Catching a stream of oil isn't a big deal, but the filter tends to go unpredictably.
@deandigiacomo2010
@deandigiacomo2010 2 ай бұрын
👍👍
@Fireinahorn
@Fireinahorn 4 ай бұрын
Why does generac not recommend a l battery load tester?
@HVACRSurvival
@HVACRSurvival 4 ай бұрын
They claim it might cause the battery to explode if it has any damage cells
@Fireinahorn
@Fireinahorn 4 ай бұрын
I commented before finishing the video, and you address it. Thank you for this no nonsense video. Tons of info. here we really appreciate it.
@dtouw
@dtouw 10 ай бұрын
In my area that generator would have never passed code! How is it that close to the house!
@harrydickson4575
@harrydickson4575 Жыл бұрын
👍👍👍awesome
@DieterMe
@DieterMe Жыл бұрын
Propane or LPG driven combustion engines are eating Sparkplugs because Gas has a height and dry flame. Your engine has only some hours worked. They only should be replaced after 1000 Hours of running and look actually like new ones.
@chriscurtiss99
@chriscurtiss99 Жыл бұрын
That generator is out of code. It needs 5ft clearance from windows, and it’s too close to the hvac unit.
@mikerossman9863
@mikerossman9863 7 ай бұрын
Could be a garage🤷🏻‍♂️
@gerdberg4188
@gerdberg4188 16 күн бұрын
Could have been installed before those updates
@justme5384
@justme5384 Жыл бұрын
An auto mechanic said it's a no-no to fill up the filter, you're potentially introducing contamination into the system
@HVACRSurvival
@HVACRSurvival Жыл бұрын
That's the weirdest thing I've heard, I wonder how they came up with that.
@jonathanontkean7270
@jonathanontkean7270 Жыл бұрын
So when you do your oil change on your car do you not put oil in your filter. It’s the same principle. Just different application. It allows the flow of oil from filter back into the system easier on start up when it’s already has the oil in it.
@justme5384
@justme5384 Жыл бұрын
@@jonathanontkean7270 definitely no oil in the filter, just some on the o-ring
@justme5384
@justme5384 Жыл бұрын
The mechanic is Rainman Rays Repairs here in KZbin, he has a few videos where he talks about it
@kevinmarchini5272
@kevinmarchini5272 Жыл бұрын
3rd generation mechanic going back to the 50s that is completely incorrect doesn't even make sense its no different than filling the crankcase or just having the filter off all 3 are chances of contamination so in your theory the right way is don't change it which goes back to incorrect you want the media wet when the pump slams oil in to it this also helps dry starts
@jayblemsin4226
@jayblemsin4226 11 ай бұрын
Lol safety glasses and ear pro for an oil change
@HVACRSurvival
@HVACRSurvival 11 ай бұрын
Yep, people make mistakes everyday that’s why medical insurance is outrages. Laugh later when your ears are ringing and you can’t see well because something got into your eye.
@nspro931
@nspro931 Жыл бұрын
That unit was installed without much regard for proper clearances.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
True and true!
@BrianD-ds4dx
@BrianD-ds4dx Жыл бұрын
Rick, we specialize in Cummins in our shop but also have techs certified in Generac because we used to install a lot of them pre fuel plenum lawsuit. Recently moved a 22kw guardian about 60 feet for a homeowner in Houston metro area who had it installed by a “generator company” that was contracted by the solar company putting in the panels. Bottom dollar In unincorporated area of Harris County, TX with no permitting or inspection required . Gen set exhausted directly beneath dryer vent with pre existing damage. 3 days of run = fire department responding for carbon monoxide poisoning. I fail to understand why people cut corners with things that can kill them…. I hope folks who watch your videos have the self awareness to know if certain tasks are outside their ability level….and your video certainly demonstrates how the work SHOULD be done and will be done by a professional
@KuntalGhosh
@KuntalGhosh Жыл бұрын
That is milli ohm internal resistance. If it was 5mega ohm at 13v theb touching the terminals would drain your battery 😂
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks for clarifying that👍👍. It's been years since studying the electrical mathematical nomenclature.
@wcelect
@wcelect Жыл бұрын
Throw those Champion plugs in that bush in front of the generator and put in some NGK’s. Champion plugs are garbage, I don’t know why Generac keeps using them.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
🤷 beats me.
@RaySmith-x6x
@RaySmith-x6x 3 ай бұрын
@@HVACRSurvival They get them cheap
@fellpower
@fellpower 5 ай бұрын
Doing things for years means nothing. i can have bought a guitar 20yrs before - and never played it....
@tbelding
@tbelding Жыл бұрын
Rule of thumb on those filters. Oil the gasket (some call it an o-ring, but it's usually flat, so it's a gasket). Thread the oil filter into place until it just touches. Then rotate the filter _three quarters_ of a turn. In 36 years of working on my own cars (IT consultant, not mechanic), I have had _one_ brand of filter back off. Funny enough, it's the one that other people all swear by, rather than at. Wix. Luckily, I caught it on my wife's car when it was just dripping, and it hadn't popped out. I will say that when I hit something that I've paid for that has a "locked" area - I scream bloody murder at the manufacturer. I understand not making it -easy-, but it's -mine-, not theirs. If they want to hold that code, then they need to do the service on it for me for nothing. I've never failed at getting the access I want.
@xxmrgoatxxzzz4782
@xxmrgoatxxzzz4782 Жыл бұрын
I’ve dealt with way worse and also way more trees in the way
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Congratulations! We get screwed every day by stupid stuff like this, because more homeowners watch my videos than service technicians is why I made this video, it was to point it out to the homeowners that aren't real bright and put put the things like this right in our way.
Low Hours Generac Won't Start
1:14:52
James Condon
Рет қаралды 333 М.
Generac Generator Just Cranks
28:55
HVACR Survival
Рет қаралды 82 М.
ТВОИ РОДИТЕЛИ И ЧЕЛОВЕК ПАУК 😂#shorts
00:59
BATEK_OFFICIAL
Рет қаралды 5 МЛН
小路飞还不知道他把路飞给擦没有了 #路飞#海贼王
00:32
路飞与唐舞桐
Рет қаралды 86 МЛН
When Cucumbers Meet PVC Pipe The Results Are Wild! 🤭
00:44
Crafty Buddy
Рет қаралды 56 МЛН
Generac Home Generator Wont Start Over Crank 1502 Code
20:23
HVACR Survival
Рет қаралды 43 М.
Generac Generator Not Testing! See Why
16:17
HVACR Survival
Рет қаралды 24 М.
Large Diesel Generator - Shuts Down With An ERROR | Can I fix It?
19:31
Generac Generator Won't Start
1:09:21
James Condon
Рет қаралды 99 М.
More Mistakes More Problems New Install Failures
33:14
HVACR Survival
Рет қаралды 37 М.
Servicing and transfer testing a 24kw Generac standby generator
19:32
Maynard Family Homestead
Рет қаралды 50 М.
General Maintenance for Generac Generator, Schedule A & B
17:25
Jerry Jackson DIY
Рет қаралды 25 М.
Generac Standby Generator Wont Start AGAIN!!!
25:13
HVACR Survival
Рет қаралды 109 М.
ТВОИ РОДИТЕЛИ И ЧЕЛОВЕК ПАУК 😂#shorts
00:59
BATEK_OFFICIAL
Рет қаралды 5 МЛН