I CAN'T SHAKE THIS STICKY BOOGER OFF ME

  Рет қаралды 45,671

HVACR VIDEOS

HVACR VIDEOS

11 ай бұрын

I just cant shake this booger off ... so I guess I will just get it running...
SLOPPY FLOPPY HAT AFFILIATE LINK - amzn.to/3s3i7vu
HVACR VIDEOS NEW MERCH WEBSITE - www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon / hvacrvideos
Becoming a KZbin channel member / @hvacrvideos
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - / hvacovertime
Social Media
Facebook / hvacr-videos. .
Instagram / hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Пікірлер: 190
@whodat90
@whodat90 11 ай бұрын
I'm not an HVAC guy. A while back my wife asked me why I watched you, and I told her it was because it's always worth watching a good teacher teach. Fast forward, couple days ago the AC went off in my house so I started with the big picture, grabbed the ammeter and figured out the compressor wasn't running, checked for and found voltage at the contactor, checked the compressor for short to ground (none) pulled and tested the capacitor and found it bad. $18 later for a new one and my AC is up and running again with no service call. Thank you sir!
@wolphin732
@wolphin732 11 ай бұрын
hope you broke down to your wife the amount a service call would be... compared to your time learning basic knowledge of of troubleshooting :) Great for you!
@FrNMGuy
@FrNMGuy 11 ай бұрын
GOOD FREAKING WORK!
@Exile1213
@Exile1213 11 ай бұрын
And a blowy
@ronroth8788
@ronroth8788 11 ай бұрын
saved yourself $250++
@zaccody6980
@zaccody6980 11 ай бұрын
Heck yeah man that's awesome
@stazeII
@stazeII 11 ай бұрын
Literally LOL’d when you redid all the wiring. You’re a good man sir! Today Chris fixes problems for future Chris (and/or his employees).
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 11 ай бұрын
With how much that cabinet resembled a Cult of the Flying Spaghetti Monster's Alter after a 6 day bender, he pretty much had to to figure out what went where... 😄😁😆😅😂🤣
@Colt-wr6wx
@Colt-wr6wx 11 ай бұрын
Yes.. and I love it. Lol gotta do it right the first time
@jordanhenshaw
@jordanhenshaw 11 ай бұрын
But only to have the entire unit be replaced a month later. I did that a couple months ago and the unit was replaced a week later, lol.
@user-sas._.
@user-sas._. 11 ай бұрын
My house has this exact rtu. Total hackjob, horrible intallation, wires are a mess, 3rd party condenser fan, and beat up condenser coil. Before i rented that house i saw how it was remodeled when they replaced the swamp cooler and installed the 20 year old used york unit. landlord doesnt care if anything happens to the house once there was no cooling called the landlord but i got no response but bakersfield heat is no joke so my only choice was to fix the unit and thanks to your videos i diagnosed it and replaced the contactor, capacitor, redone the wiring and cut off the heating because that heat exchanger was sketchy and it doesnt get that cold here anyways.
@SOU6900
@SOU6900 11 ай бұрын
Ok the fact that you can read your meter remotely through your phone is amazing
@InconsistentManner
@InconsistentManner 11 ай бұрын
That York unit is from Norman, Oklahoma and was Manufactured in November of 1998. They still make a similar version of this model to this day. I know this because I used to work for Johnson Controls before York was bought out and became a subsidiary. I worked four years from 2002 to 2006 and a family member still works there to this day.
@Bryan-Hensley
@Bryan-Hensley 11 ай бұрын
They made a Coleman version of it too. Or basically different stickers
@fredflintstone8048
@fredflintstone8048 11 ай бұрын
Eat before you're hungry, and drink before you're thirsty. Once you get behind it's too late, you can't catch up during that day, especially if you remain out in the heat. Take it from someone who lives and works in southern Arizona where these kinds of temperatures are normal every summer. It's a normal way of life here. Dehydration also has an effect on your ability to think clearly.
@MrGamerholic
@MrGamerholic 11 ай бұрын
Also remember to keep your electrolyte levels up. Look up water drunkenness due to electrolyte imbalances.
@thomashines8
@thomashines8 11 ай бұрын
In Iowa as a tech I live off Liquid IV, Gatorlyte and Body Armour. I promise it’s worth it at the end of the day. We get 100 with 80% humidity. Absolutely brutal.
@rustblade5021
@rustblade5021 11 ай бұрын
yeah those hats are great, i've got a few. also instead of a cold towel around neck, dunk your arms in a bus bin of ice water. also drinking a slushy or something like that before going on a hot roof helps immensely
@44R0Ndin
@44R0Ndin 11 ай бұрын
If it gets truly nasty outside (or you have to work in an un-conditioned attic), they make "cooling vests" which is a simple vest with a layer of insulation on the outside and a multitude of mesh pockets on the inside, and inside those mesh pockets you put gel cold packs. Sometimes they are a little too effective, but the key thing to know is that they cool your torso, aka the core of your body, and that's the most efficient place to apply cooling because your body already has a "coolant" system in it, in the form of your blood, arteries, and veins. That's also why dunking your arms in a bus bin of ice water is so effective, your blood rather quickly transfers the cooling to the rest of your body.
@gregdennis3523
@gregdennis3523 11 ай бұрын
Wish I was young. I would definitely have enjoyed working in HVAC! The rewire looks amazing!
@markae0
@markae0 11 ай бұрын
@ 7:42 (later on) Someone downstairs- ground level sees the fuse box " Hey this fuse is turned off. I better turn it back on!" and you on the roof have bare exposed wires that you are wiring to a new disconnect. I hope you padlocked the door to the fuse box. Great VIDEO!
@awesomestuff9715
@awesomestuff9715 11 ай бұрын
Usually you don't lock out the entire panel, instead you have a lockout on the specific breaker(s) that you are working on
@HVACRVIDEOS
@HVACRVIDEOS 11 ай бұрын
Yes it was locked out
@Farm_fab
@Farm_fab 11 ай бұрын
Chris, I used to work for a maintenance contractor at a food manufacturing company, and one of my coworkers took Gatorade up on the roof, and kept it cold in the run off from the AC units, in a bucket. He got in trouble, but not for long, when the safety manager told my boss that anyone working on the roof needed adequate breaks and needed to stay hydrated. Keeping his drink cold was a good idea. I've used that water to help wash the inside of locked out units that couldn't be pressure washed, since water on some areas of the roof was on the front side of this massive roof, and no one wanted hot water on a hot roof, even though there was a bit of an advantage to warm water for cleaning.
@tedhicks5431
@tedhicks5431 11 ай бұрын
Sux to have to run 400 plus feet of water hose no pressure
@tbelding
@tbelding 11 ай бұрын
You have to watch out. If you're running REALLY hot, you don't want any drinks to be lower than cool, preferably lukewarm. Really cold drinks can cause colic, basically. Tie your guts in knots.
@tedhicks5431
@tedhicks5431 11 ай бұрын
@@tbelding I've heard of that
@_iLLuSiv3_
@_iLLuSiv3_ 11 ай бұрын
The most important and best fix for a York is to push it off the roof!
@Bryan-Hensley
@Bryan-Hensley 11 ай бұрын
The problem with these is they called them commercial units but they are residential
@hrdworkin7633
@hrdworkin7633 11 ай бұрын
I'm sure someone else commented but the unit is single phase and amp draw usually higher than 3 phase. be careful in the heat.
@melkortdl2010
@melkortdl2010 11 ай бұрын
I know it sounds dumb, but Thanks for reminding us to watch the Entire video. Most people (including me) didn't know for the longest time that it makes a big difference in the money you receive. You make great videos and spend a lot of time providing an after-action summary of what went down to help folks in the industry understand the thought process. Thanks, Chris.
@kellyleach8991
@kellyleach8991 11 ай бұрын
I do my best to watch the entire video, including not skipping the ads. However, when KZbin throws in a 15- or 30-minute ad, i just can't do it. Sorry, Chris!
@skuresture
@skuresture 11 ай бұрын
Wow. That electrical bowl of spagetti is a real dumpserfire.
@FrNMGuy
@FrNMGuy 11 ай бұрын
As soon as I saw the rat's nest, I knew your OCD was not going to deal with it 😂
@75sRax
@75sRax 11 ай бұрын
it’s always a good day when Chris uploads. Love your videos!
@fshn76
@fshn76 11 ай бұрын
Great video Chris. I find my OCD drives me crazy with wiring and also with my van. Drives my wife nuts at least 3 times a week I will go in the back of the van and organize. You can keep that Coachella heat to yourself😂
@pedrojardim325
@pedrojardim325 11 ай бұрын
Hi. Chris I was. Lissen to. U on. Livestream And. Some1. Said Having hard. Time. Getting. In To. The HVAC tryde For. Mi. ( Ty branamen) Is. The. Best teacher out. There. To. Learn. Something
@jeffsmith846
@jeffsmith846 11 ай бұрын
That unit must have been built extremely well to work in the desert with temps 110 plus on the regular. And it is 25-35 years old.
@417HVAC
@417HVAC 11 ай бұрын
Above & Beyond for another customer. That’s why Chris is the best
@timothyhiggins8934
@timothyhiggins8934 11 ай бұрын
hey. i'm new to the channel, and new to high end refrigeration but have done residential a/c for 17 years and working with some cool guys showing me the ins and outs of this side of the field. just wanted to thank you for the time and effort you guys put into these videos. i can see it helps a lot of people, including myself
@tonyking9235
@tonyking9235 11 ай бұрын
YOU WONT NEED TO WATCH ENEY ONE ELSE . GOOD MAN IS CHRIS
@Starchface
@Starchface 11 ай бұрын
When you discussed having the manager call your guys on the roof it got me thinking. If you were alone up there and had an accident or lost consciousness in these conditions, it could be curtains. Be careful out there. The last thing you want is the manager finding you on the roof the next day.
@buixote
@buixote 11 ай бұрын
"Shake that Booger"! Sounds like disco! You're probably too young to remember, Chris! ;-) It's inspirational to see you "lose it", and polish the Turd!
@mysock351C
@mysock351C 11 ай бұрын
Regarding the wire size, fwiw starting the compressor is what it usually needs to be sized for due to the inrush current, which can’t really be measured on a DVM due to the short duration. Combine a long run with sagging line voltage and the compressor might not start. Used to do the MEP design for PETCO years ago, and they had a 110V reach-in fridge (can’t remember who made it) for their aquarium department, and in certain stores they would all end up nuking their compressors after a while. Turned out the compressor would intermittently fail to start at times due to the excessive voltage drop with normal 12 AWG wire, and that was what kept killing them. Had to retrofit all the stores with either 10 AWG (or 8 AWG for long runs) to stop them from going locked rotor at start-up. Edit: And yeah working on roofs in 100+ degree heat really sucks. Hated that.
@jhill.7216
@jhill.7216 11 ай бұрын
Most definitely guy respect to you I work in the trade but mostly hospital work but I salute you my guy 👏🏽
@justink303
@justink303 11 ай бұрын
I have the same hat too! They are floppy but they are awesome at keeping the sun away. Stay cool. We have not as hot temps but sure making up for it with the humidity.
@al6347
@al6347 2 ай бұрын
Hey you found an hvac roof top seat. 😂😂😂
@matthewrichardson2467
@matthewrichardson2467 11 ай бұрын
Can't imagine working in that heat! Nice you have a plan to stay cool and good idea getting the manager to check on your team when they're on the roof! I just imagine when you send them an invoice for a new disconnect, evap fan motor, rewire and R22 they'll go "Hmm this unit is costing us lots in repairs, Lets replace it next week"..
@44R0Ndin
@44R0Ndin 11 ай бұрын
Especially that R22, like Chris said that stuff's "liquid gold" because they literally don't make it any more, what people have stashed away is all there is to use.
@GeminiSeven43
@GeminiSeven43 11 ай бұрын
Great job Chris and thanks so much for going the extra mile on that wiring. Looking at that mess makes you cringe and now it will be easier for anyone following you to check for problems and you can leave there knowing that the "Dumpster Fire" is a little bit better. Thanks for taking us along.
@williambutler7312
@williambutler7312 11 ай бұрын
Bravo Chris , another HVACR win . . . #respect to the wiring repair given the circumstances
@lillian6023
@lillian6023 11 ай бұрын
We've got the same policy of checking on reefer techs when we do a roof job any time of day during summer. Dispatch will call us and make sure we're ok, taking breaks and staying hydrated
@salvatoreluciano864
@salvatoreluciano864 11 ай бұрын
Probably a good idea to run your continuity/short to ground test BEFORE moving wires around.
@retrozmachine1189
@retrozmachine1189 11 ай бұрын
These days you don't need to be a genius electrician if electrical isn't your trade. There's a good selection of web sites that will give you a good idea of what wires you should be running. Plug in your expected load, run length and other environmental considerations and they spit out regulation compliant recommendations. Note, it's a recommendation only. It's still up to the tech to make the determination to use that recommendation. Of course, only do electrical if you are permitted to do it.
@richardbartlett6932
@richardbartlett6932 11 ай бұрын
Makes no sense you don't set up an umbrella. Makes such a massive difference when working Great job
@djish3223
@djish3223 11 ай бұрын
I love when you said "I went crazy" when the video cut back in and then everything was nice and neat. OCD. LOL
@davebigdog
@davebigdog 11 ай бұрын
22% humidity LoL We wish we saw 22% humidity here in the south
@ratoone233
@ratoone233 11 ай бұрын
Hi Chris ! As usual, nice video and good work. Just wish we could see this rewiring, this seems a pretty insane thing to do, especially for a unit this old (probably not worth, but we got to respect the dedication and professional awareness 😉). Cheers
@gregmercil3968
@gregmercil3968 11 ай бұрын
I’ve work on a few Yorks like that one, and it’s newer than you think it is. This one was manufactured 2003. That 2 pole contactor to the left is for the draft inducer, which is never used but the heat isn’t hooked up. Seems a bit overkill to use a contactor for that little inducer motor. 😂
@coreyb4073
@coreyb4073 11 ай бұрын
Hack job electrical is one of my biggest pet peeves, i am guilty of gutting more than a few cabinets because it bugged me
@stevencossaboon3237
@stevencossaboon3237 11 ай бұрын
Great job Chris. Watch that heat.
@rcstl8815
@rcstl8815 11 ай бұрын
Fashion plate you are! A floppy hat does not take away anything from our appearance. We are gods doing this work.
@appomattoxross6751
@appomattoxross6751 11 ай бұрын
The fuse holder disconnect box: A worthless design in my opinion and experience. Always replace with a safety switch.
@gdoggy1678
@gdoggy1678 11 ай бұрын
As a Safety Manager your point on lone working at 12:50 is vital. Thanks for always looking out.
@MrIsaiah00
@MrIsaiah00 11 ай бұрын
I threw up and got anxiety attic with leg cramps on Friday, Stay safe and hydrated everyone…
@ivoryjohnson4662
@ivoryjohnson4662 11 ай бұрын
I like your work ethic …. Stay cool stay safe
@805HVACR
@805HVACR 11 ай бұрын
Well done Chris thumbs up 👍🏼👍🏼
@thehappytexan
@thehappytexan 11 ай бұрын
I’m not an hvac tech or electrician, just a guy that researches projects before doing them. When you said they ran #8 wire on a 100’ run for a 60 amp circuit, I started shaking my head. There are simple charts that show what is needed for a given amperage over different distances.
@Alexelectricalengineering
@Alexelectricalengineering 11 ай бұрын
Nice fix of the wiring, I would agree that the wire should be 6 AWG
@smithno41
@smithno41 11 ай бұрын
I didn't see him tag out lock out the breaker before he started installing the new disconnect. Maybe I'm paranoid, but if I can't see the breaker from the place where I'm working, it gets locked out.
@HVACRVIDEOS
@HVACRVIDEOS 11 ай бұрын
It was locked out, I actually locked the entire panel shut
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 11 ай бұрын
It doesn't matter what you actually run at, you MUST size the wires for the Circuit Breaker/Fuses protecting the circuit modified by the ambient temperature and circuit length (they each derate the circuit requiring a larger wire size to compensate for the wires reduced current carrying capacity - hot wire and long wire runs can't carry as much current as a shorter, colder circuit)... Depending on just how hot it CAN get in summer, I likely would have gone with a 4 Gauge wire for a run that long (unless the NEC specified a 4 Gauge to begin with, then I might have gone with a 2 Gauge)...just in case the area got a record breaking heat wave, I don't want my circuits to overheat and either blow fuses/trip breakers or catch fire...
@jrmcferren
@jrmcferren 11 ай бұрын
Air conditioning has special rules. You should do the ambient adjustment, but the wire for air conditioning is sized at the maximum circuit ampacity. The breaker is sized based on this figure or the largest breaker and fuse marked on the unit. You may size the wire based on the fuse and breaker like normal, but you are allowed to use the ampacity figures. The reason you are allowed to do this, is the air conditioner has overload protection and that is figured in on the minimum ampacity. The breaker or fuse can be sized at a higher than normal value for the wire size because the breaker or fuse is only providing short circuit and ground fault protection. Simply the overload in the AC protects the wire (and the AC) against overload, the fuse or breaker protects against shorts and ground faults. Mike holt had a video on this.
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 11 ай бұрын
@@jrmcferren This is basically what I said, Chris mentioned the System had a Minimum Ampacity of 45 Amps (I think, somewhere around that) but had a 60 (or 70 Amp) fuse in the on unit disconnect and 70 Amp Breaker in the local Panel. According to my comment, that means that regardless of what the Minimum Ampacity listed for the Unit is, the wires MUST be sized for the 70 Amp Fuse/Breaker ACTUALLY Protecting the Circuit derated according to the ambient temperatures found at the location and length of wire run...
@edwinpadilla6093
@edwinpadilla6093 11 ай бұрын
Heeeey, at my younger age, I had the opportunity to choose in my vocational school year and watching your video show me I should have chosen yours , I've would have been earning tons of money 💰 here in year round sun 🌞 ☀️ Puerto Rico 🇵🇷 😀 Heeeey keep up the good acoustic work !!!
@electroimpex8897
@electroimpex8897 11 ай бұрын
Greets from Germany
@sven33r
@sven33r 11 ай бұрын
I'm from Germany too and can't imagine the heat on the roof. 110 F is 43 C. I know Germany is quite cold right now but still our hot days don't start at 9 am with over 40 C
@Bryan-Hensley
@Bryan-Hensley 11 ай бұрын
Every time I see that unit I'm scared I'm going to get a call from my customer who has one of those.
@jordanhenshaw
@jordanhenshaw 11 ай бұрын
You said it was a fixed orifice but you had measurequick on capillary tube.
@peterhodgkins6985
@peterhodgkins6985 11 ай бұрын
You should sell those high-shade hats! Those are great. Yeah, they look a bit dorky, but it's better than heat stroke. Good job under some seriously bad conditions!
@danpresson
@danpresson 11 ай бұрын
Awesome video good you got off the roof when you did you looked flushed you always go the extra mile
@michaelcoonts6253
@michaelcoonts6253 11 ай бұрын
I’d like a video on Pricing jobs. Like how much mark up on parts and do you charge hourly or per work preformed?
@tedhicks5431
@tedhicks5431 11 ай бұрын
Haven't seen a 1ph rooftop for ever
@johnwalker890
@johnwalker890 11 ай бұрын
Good job Chris, Yeah that wire was probably under rated, meaning the feeder, the conduit looks small too, but you get upset about wire messes, and I can understand, I don't like it either, I try to make circuits look clean and uniform, a neat mess, instead of a all out mess.
@for2utube
@for2utube 11 ай бұрын
Try a Torras Coolify neck cooler. Helps me when doing outside work.
@Colt-wr6wx
@Colt-wr6wx 11 ай бұрын
Nice one.. new disconnect and condenser fan motor.. probably get another 5 years outta that one.. haha
@matthewcarlacci
@matthewcarlacci 11 ай бұрын
Good job on that wiring.
@brake_4_cake
@brake_4_cake 11 ай бұрын
I never understood the American love for wire nuts. "These are notorious for making the worst possible connections, are the most challenging to install correctly, and more prone to errors than the other choices. Let's use them!"
@alibuolayyan9038
@alibuolayyan9038 11 ай бұрын
Today, the temperature in Kuwait is 52 degrees Celsius, which is equivalent to 125.6 Fahrenheit
@billynomates920
@billynomates920 11 ай бұрын
it is literally half that temperature in the u.k right now and i've got my fan on! 🥵♨
@Transit_Biker
@Transit_Biker 11 ай бұрын
The fins on that condenser coil are toast - time to retire the booger!
@geminithugbaby473
@geminithugbaby473 11 ай бұрын
Maybe rinsing down the condenser would help with the subcooling a little ?
@infl
@infl 11 ай бұрын
The minimum circuit ampacity has the 125% oversize already added, multiply by 0.8 and you have max continuous draw
@tonyking9235
@tonyking9235 11 ай бұрын
TRY USEING A HANKY. THAT USUALLY HELPS. 😊😊 I BET YOUR GOOD WITH CHOP SUEY STICKS 😊😊😊 BIRD NEST COMES TO MIND LOOKING AT THAT . YEP THE BEARING ARE SHOT . ON THAT FAN .
@stephanmetph
@stephanmetph 11 ай бұрын
That green bottle is full of gold man😮
@aprimebrahimi8960
@aprimebrahimi8960 11 ай бұрын
Hi Chris. Can I ask what kind of app and what kind of meter that you have when you cut the power from panel that you saw on your phone? Im Hvac tech and this is so nice tool.
@uxwbill
@uxwbill 11 ай бұрын
That a puff of dust (or sand?) came out of that circuit breaker is just amazing, and not in a good way. It's crazy how that stuff gets into everything.
@TeamWagy
@TeamWagy 11 ай бұрын
Used to live in Albuquerque and now I’m in Louisiana. This humid heat ain’t it, I miss the desert at times
@Payitforward42
@Payitforward42 11 ай бұрын
KNOW WHAT I MEAN VERN! ❤
@wanabeeepro
@wanabeeepro 11 ай бұрын
You can just bend the contacts of that disconnect plutnoutward. They go flat over time
@tomm5712
@tomm5712 11 ай бұрын
How come you don’t work on any daikin vrv units or split systems?
@armandotorres626
@armandotorres626 11 ай бұрын
I'll take that dry heat over Florida's humidity any day!!!!!! 🥵🥵🥵🥵🥵🥵
@WJimmy90
@WJimmy90 11 ай бұрын
Nice!
@mastahc411
@mastahc411 11 ай бұрын
I despise pulling out as well.
@alexanderkupke920
@alexanderkupke920 11 ай бұрын
There is nothing silly in waering a hat with a wide rim in such conditions. When on vacation in florida I see all the landscaping guys wearing those hughe hats, mostly like straw hats, all the time to keep them protected from the sun. It is about the same. Just yours seems to be quite eaasy to keep in your bag if needed, which might be a good idea. So you can grab it any time you may need it without having to go back to your van. It is with most specialized tools and even more so protective equipment (Sun Protection, Eye Protection, Hearing Protection,...). The stuff you can just grab will be more likely to be used than the stuff you need to go and get.
@latenitehvac868
@latenitehvac868 11 ай бұрын
Pray for the techs that brave 120 degree heat to fix those units
@TravisDoesGames
@TravisDoesGames 11 ай бұрын
The ambient is over 100 degrees and they’re getting cooling way below that. Are the buildings there very insulated? I thought you couldn’t have the ac that far below ambient. Guy from new york here
@kennethchristensen7457
@kennethchristensen7457 11 ай бұрын
Why do you have fuse disconnect ? When a non fuse disconnect is only required NEC.
@jangoofy
@jangoofy 11 ай бұрын
This might be a stupid question, but what happened to the control box thingy to the far right after cable cleanup ?
@alsavage1
@alsavage1 10 ай бұрын
@18:24 he says that it's never had the heating section connected to gas, so when he rewired, he removed all the electrical related to the heating side. You can most clearly see this before-and-after if you watch @13:19 for ten seconds.
@GlenS123
@GlenS123 11 ай бұрын
It's sad how our suppliers think we want the cheapest crap possible. Those pull-out disco's SUCK!
@MTGamingFr34k
@MTGamingFr34k 11 ай бұрын
Be on a roof when it's 101F with 80% humidity. Psh.......
@lordjaashin
@lordjaashin 11 ай бұрын
Chris can you do a video about oil traps on suction and discharge lines? especially for mini splits with long lines
@richardbartlett6932
@richardbartlett6932 11 ай бұрын
follow the manufacturers guidelines. each manufacturer has their own spec.
@lordjaashin
@lordjaashin 11 ай бұрын
@@richardbartlett6932 no mention of oil traps from mini split manufacturers but hvac technicians install oil traps in suction line when outdoor unit is above the height of indoor unit. don't know why they do that
@brandonprice2897
@brandonprice2897 11 ай бұрын
@@lordjaashinmost of the time techs will do that to prevent all of the oil from the compressor “pooling” in the lower line sets and then causing major problems with the compressor.
@lordjaashin
@lordjaashin 11 ай бұрын
@@brandonprice2897 so what rule of thumb is followed for where to install oil trap, at what distance, etc?
@brandonprice2897
@brandonprice2897 11 ай бұрын
@@lordjaashin that you would probably be best to call customer service and tell them that you’re having some issues with pooling and that you want to know the best place to add in an oil trap.
@daveyt4802
@daveyt4802 10 ай бұрын
What a mess. I hate that. Too many hackers in there?
@catfood9707
@catfood9707 11 ай бұрын
Since the unit has a 23 degree temp split and just needed a disconnect and fan motor, why you reccomending a remove and replace? It isn't the prettiest unit but it seems like it's doing a pretty good job.
@brandonprice2897
@brandonprice2897 11 ай бұрын
He recommends replacing the unit because there have already been some extensive repairs made to it and he ,probably constantly, gets calls about something else wrong. I can’t blame him one bit especially since he stated that it’s completely out of his way to come there and it’s not in his service area.
@alsavage1
@alsavage1 10 ай бұрын
It's a bit over 20 years old, which is probably beyond the service life of most RTUs in that environment. Plus, the tech has moved on and is more efficient, so the running costs are potentially lower with a replacement pkg. as well.
@danielelise7348
@danielelise7348 11 ай бұрын
See,dinosaurs do exist.😆
@tracysellman1562
@tracysellman1562 10 ай бұрын
Lord have mercy all that rats nest of wires got my OCD in high gear, Chris You are like me, I would have done the same it looks so much better in that elect component area now and makes sense. Those Yorks, Tranes, and Lennox commercial units from the 80s, I cut my teeth on, when I got out of the Air Force as an Explosives expert and changed careers, when to school for HVAVR. I even had a few RTU units I was tempted to blow up. I had a T-Shit that said "The HVACR whisper, Quiet while I work, please! Now tell me where it hurts! LMAO :)
@tiredagain6722
@tiredagain6722 11 ай бұрын
Seems to me that 23% humidity is high for the desert 😳, YUK
@Domestic_Tedster
@Domestic_Tedster 11 ай бұрын
Above and beyond Chris
@Syntappi
@Syntappi 11 ай бұрын
Damn it is hot there! I live in Finland and for us even 30c (86f) is really hot 😀
@hollieriversjustingarza6726
@hollieriversjustingarza6726 11 ай бұрын
Yo Chris we got a couple of fires going on the bonny fire and the York fire
@shakeyjakey35
@shakeyjakey35 11 ай бұрын
great video defo a rats nest i think i would have done the same tideing it up would have drove me bonkers leaveing it like that great video
@Brisket9392
@Brisket9392 11 ай бұрын
I don't know how you all deal with those temps. Not even 10am and at 104° sounds ridiculous! Not habitable! Surprised that thing works in those temps without some type of shroud. Fan blade seems so deep.
@timothygingras6939
@timothygingras6939 11 ай бұрын
Where did the ignition control module disappear to?
@alsavage1
@alsavage1 10 ай бұрын
@18:24 he says that it's never had the heating section connected to gas, so when he rewired, he removed all the electrical related to the heating side. You can most clearly see this before-and-after if you watch @13:19 for ten seconds.
@abdullah_q8171
@abdullah_q8171 11 ай бұрын
Temp 43 Celsius 😮
ONE LEAK LEADS TO ANOTHER LEAK
26:49
HVACR VIDEOS
Рет қаралды 39 М.
AC Troubleshooting Exercises
52:29
HVACTIME
Рет қаралды 4,4 М.
КАК ДУМАЕТЕ КТО ВЫЙГРАЕТ😂
00:29
МЯТНАЯ ФАНТА
Рет қаралды 8 МЛН
Heartwarming Unity at School Event #shorts
00:19
Fabiosa Stories
Рет қаралды 16 МЛН
HURRY EVERY AC IS DOWN......
31:56
HVACR VIDEOS
Рет қаралды 340 М.
YORK PACKAGE UNIT NOT COOLING
14:35
HVACR VIDEOS
Рет қаралды 99 М.
Defeating Microwave Weapons! - Part 1
29:28
Tech Ingredients
Рет қаралды 1,1 МЛН
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 218 М.
THE FREEZER IS DOWN AND WE NEED YOUR HELP!
36:43
HVACR VIDEOS
Рет қаралды 57 М.
EVER FOUND A RAT LIVING IN AN EXHAUST FAN ?
13:07
HVACR VIDEOS
Рет қаралды 34 М.
Unable to Repair 4 Year Old HVAC Unit…Homeowner is Furious! 😡
15:37
I bought an UNUSED 70-year old ROLLS-ROYCE crate engine!  How bad could it be?
1:37:54
Pacific Northwest Hillbilly
Рет қаралды 2,7 МЛН