Ideal Logic Plate heat exchanger no hot water combi

  Рет қаралды 17,607

Mend Your Home

Mend Your Home

Күн бұрын

Пікірлер: 49
@Carl-re6zb
@Carl-re6zb 2 жыл бұрын
Bruv... it takes guts and sacrifice to continue to film this to educate people whilst forsaking the requirements to make a straightforward job so tricky. The fact you had to run downstairs to isolate the mains whilst having no means to control the situation and still continue to film... I salute you... 99% of us.. me included would of after the 1st attempt, thought sod it... I'll use both hands to do it then film and explain.. Your a star brother... Thank you.👍🏾
@mendyourhome
@mendyourhome 2 жыл бұрын
I appreciate it, hopefully 1 day I'll improve and be up there with top KZbin boys 😂 thanks
@ryanjennings7830
@ryanjennings7830 Жыл бұрын
Well done matey working on boilers is nothing but a challenge these days
@a-spaceman
@a-spaceman 7 ай бұрын
Great you showed us what can go wrong and how to fix it!
@edthelasttribe9580
@edthelasttribe9580 2 жыл бұрын
I can’t see , you rubbed enough silicone on those washers, apart from anything else, it’s spot on , brother 😂
@experienceb4bob
@experienceb4bob Жыл бұрын
A very brave video...with phone in one hand and the job in other ..running down the staircase and dealing with a leak on a new fitted plate...really helpful video. Any more you have how to change diverter valve and prv on these
@mrnsp5013
@mrnsp5013 Жыл бұрын
Top video buddy
@mendyourhome
@mendyourhome Жыл бұрын
Thanks 👍 sub for more
@kennethdzengedza8978
@kennethdzengedza8978 2 жыл бұрын
Thanks for sharing
@NibblestheHamster
@NibblestheHamster Жыл бұрын
Could you not have isolated cold under boiler?
@mendyourhome
@mendyourhome Жыл бұрын
No it couldn't
@grimawormtongue2014
@grimawormtongue2014 Жыл бұрын
​@@mendyourhome I changed a hx plate on a Worcester greenstar erp, I drained the heating system, hot and cold taps and took out the pressure from the Expansion vessel and isolated return, flow and cold under the boiler. When I opened the screw on the hx plate, quite a lot of water was still coming out, so I let it drain out slowly as I didn't want the water to damage any other parts, ESP the electrics. What could I have done differenly to make sure all the water is out regardless of which boiler is being worked on? Thanks.
@wiggyflat
@wiggyflat 8 ай бұрын
I do this every 2 years but isolate the water from in the kitchen and drain. I use Knockout industrial strength liquid unblocker that does the trick and gets it clean after leaving overnight.Never had to replace the unit.
@lcfc42
@lcfc42 Жыл бұрын
What would be an acceptable price for this job? I've got the exact same boiler and the same issue. Not covered by boiler plan as limescale buildup (hard water area)
@vladimird3575
@vladimird3575 Жыл бұрын
What grease silicone do you use?
@mendyourhome
@mendyourhome Жыл бұрын
1) servisol Silicone Grease 2) Regin Silicone Grease 3) Polypipe silicone grease (this 1 i also use for some plumbing)
@anandyadav5918
@anandyadav5918 2 жыл бұрын
very good explanation 👏
@mendyourhome
@mendyourhome 2 жыл бұрын
Thanks for the support
@davidrussell3890
@davidrussell3890 Жыл бұрын
I dont uderstand why you did,nt isolate the cold main under the boiler?
@mendyourhome
@mendyourhome Жыл бұрын
Can't recall didn't work or wasn't installed I think it was bodged in
@lewiscoles4350
@lewiscoles4350 2 жыл бұрын
Hi there just a quick one what was the reason you changed the plate heat exchanger I have a l3 fault on my boiler and I get next to no flow with 2 taps running I’m assuming the plate heat exchanger is blocked
@pauls826
@pauls826 Жыл бұрын
Fan matw
@wisechatswithash
@wisechatswithash 2 жыл бұрын
Thank you for sharing
@MrRawMonkey
@MrRawMonkey 2 жыл бұрын
Why did the heat exchanger become blocked when the system had a magnetic filter fitted?
@shandd9640
@shandd9640 2 жыл бұрын
This is a secondary heat exchanger. It's likely to be blocked on the domestic hot water side which is caused by lime scale and other minerals from poor water quality ie hard water coming on from the mains although It can still be blocked on the heat side from sludge as a magnetic filter will not catch everything.
@mendyourhome
@mendyourhome 2 жыл бұрын
Magnetic filters mainly capture magnetic particles, but not everything. Also this is a plate heat exchanger limescale is a common culprit on the hot water side being blocked. Because the plates are so tightly crammed in it not 1 blockage it's a slow build up over time, like a Dam that keep collecting more debris.
@alistairnewton8898
@alistairnewton8898 2 жыл бұрын
Thanks for the real time information.👍
@tk4270
@tk4270 Жыл бұрын
Whats next if plate heat exchanger has be cleaned or renewed but still no hot water and no fault codes appearing.
@mendyourhome
@mendyourhome Жыл бұрын
Diverter valve
@tk4270
@tk4270 Жыл бұрын
@mendyourhome The boiler guy has checked the diverter valve by adjusting flow to check but has not taken it apart. So far, new plate heat exchanger fitted, checked turbine, replaced fan, gas valve, switches, and checked gas flow rate at gas meter. The hot water dial is at max hot, but we are only getting lukewarm water from taps. CH radiators are piping hot. No fault codes appearing on boiler.
@jackhoskins722
@jackhoskins722 2 жыл бұрын
Can't you just shut the mains off at the boiler with the cold feed valve that's under the boiler that's how I isolate ideals normally that way would off saved you running outside
@mendyourhome
@mendyourhome 2 жыл бұрын
I couldn't isolate as normal. I might of explained it in the video, either it didn't work or wasn't an isolation. 😂 But thanks for the comment. I'd appreciate a sub. I have loads more videos also heat pump install coming soon
@mendyourhome
@mendyourhome 2 жыл бұрын
5:09 to skip drain down and straight to removing the parts.
@pauls826
@pauls826 Жыл бұрын
Why didn’t you isolate it under the boiler also could of just cleaned that plate out if it was blocked with acid unless it’s split in which case pressure would of risen on gauge
@mendyourhome
@mendyourhome Жыл бұрын
It was year ago, but i believe they didn't work or hadn't been fitted
@pauls826
@pauls826 Жыл бұрын
Mate the filling loop is the isolation keep the return shut and open the cold it isolates the flow into boiler it’s a 3way valve type are you a new engineer fumbled around abit if your flows getting hot it’s a diverter issue nothing to do with a plate please don’t give wrong info to people on here so there fucking around with their boilers
@FXHEROS
@FXHEROS 8 ай бұрын
older boilers say ZJ think this one manufactured in 2004 installed in 2012 heat exchanger cracked in 2024 11 year old.
@djhvideo
@djhvideo 9 ай бұрын
Dirt in the siphon water trap isnt indication of dirt in the heating system as it is only condensate and products of combustion.
@jeremyphilip1199
@jeremyphilip1199 16 күн бұрын
Spirit of salts would clean that heat exchanger for about 6venglish pounds rather than buying a new one. Evil stuff but does a good job.
@lindseypearson9768
@lindseypearson9768 12 күн бұрын
I’ve just been advised my heat exchanger needs replacing ? I’ve got a slight drip coming down from the boiler ?
@anthonygray5581
@anthonygray5581 Жыл бұрын
That looks brand new so didn't have a power flush...
@mendyourhome
@mendyourhome Жыл бұрын
Maybe or not well maintained
@gary8306
@gary8306 11 ай бұрын
Sink tap is nicely sealed to the worktop. SMH………..I know that wasn’t you.
@frundlemud
@frundlemud 2 ай бұрын
The system needed flushing badly. It will block again and expansion 1bar. dangerous.
@naseerulhaque2270
@naseerulhaque2270 Жыл бұрын
first drain the water then open hot plate
COMBI BOILER PLATE HEAT EXCHANGER REPLACEMENT FOR HOT WATER
18:20
plumberparts
Рет қаралды 48 М.
Thank you mommy 😊💝 #shorts
0:24
5-Minute Crafts HOUSE
Рет қаралды 33 МЛН
БОЙКАЛАР| bayGUYS | 27 шығарылым
28:49
bayGUYS
Рет қаралды 1,1 МЛН
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН
Logic: Servicing Guide DHW Plate Heat Exchanger Replacement
1:32
Ideal Heating
Рет қаралды 5 М.
Ideal Logic / Vogue No Hot Water - How To Test - Plumber
12:23
Allen Hart
Рет қаралды 64 М.
Ideal Logic Combi How To - Training Thursdays
17:43
Blue Bulldog Plumbing
Рет қаралды 6 М.
Thank you mommy 😊💝 #shorts
0:24
5-Minute Crafts HOUSE
Рет қаралды 33 МЛН