Installing PEX Water Lines: Replacing Polybutylene Piping

  Рет қаралды 134,181

Pros DIY

Pros DIY

Күн бұрын

Replacing polybutylene piping and shutoff valves under a kitchen sink with PEX. Tips and tricks on how to properly crimp and connect PEX piping, shutoff valves, and fittings.
𝗔𝗺𝗮𝘇𝗼𝗻 𝗔𝗳𝗳𝗶𝗹𝗶𝗮𝘁𝗲 𝗟𝗶𝗻𝗸𝘀
1/2" & 3/4" PEX Crimper: geni.us/xjau
PEX Cutter: geni.us/1AIbA6
PEX Rings: geni.us/i2vAp
PEX Clips: geni.us/cyZa7Xe
𝗦𝘂𝗽𝗽𝗼𝗿𝘁
Want to support my channel or give back? Help me improve on these DIY videos by making a financial contribution. All contributions no matter how small are greatly appreciated!
ko-fi.com/prosdiy
Thank you!
𝗖𝗼𝗻𝗻𝗲𝗰𝘁
More DIY videos! www.prosdiy.com
Facebook: / prosdiy
Instagram: / prosdiy
Subscribe: / prosdiy
Amazon: www.amazon.com...
Disclosure: Pros DIY is an Amazon Associate. We earn a small commission from qualifying purchases through our affiliate links at no additional cost to you.
Videos produced by Pros DIY (www.prosdiy.com) are provided for informational purposes only. Please check with all national, state, provincial, and local codes and regulations before attempting any work. Pros DIY does not assume any responsibility or liability for any damage or injury from the information provided in our videos. Please hire a licensed, certified, professional.

Пікірлер: 78
@PROSDIY
@PROSDIY 3 жыл бұрын
𝗔𝗺𝗮𝘇𝗼𝗻 𝗔𝗳𝗳𝗶𝗹𝗶𝗮𝘁𝗲 𝗟𝗶𝗻𝗸𝘀 1/2" & 3/4" PEX Crimper: geni.us/xjau PEX Cutter: geni.us/1AIbA6 PEX Rings: geni.us/i2vAp PEX Clips: geni.us/cyZa7Xe Disclosure: Pros DIY is an Amazon Associate. We earn a small commission from qualifying purchases through our affiliate links at no additional cost to you.
@tyronedavis1672
@tyronedavis1672 3 жыл бұрын
1
@dottiemarkland9069
@dottiemarkland9069 Жыл бұрын
That has absolutely nothing to do with whether or not any of you Amazon people are going to come help this old senior citizen get my water working again
@garyshearer13
@garyshearer13 2 ай бұрын
Best Pex and good plumbing practices I’ve ever seen. Great tips … preempted multiple errors Thanks
@simonlarkin2539
@simonlarkin2539 Жыл бұрын
About half way through that copper soldering was masterful!
@davidwoodard7488
@davidwoodard7488 3 жыл бұрын
Awesome details!!! The pex crimping " goofs"... FANTASTIC!!
@TheSlipperyNoodle
@TheSlipperyNoodle 3 жыл бұрын
Great video. I have the poly b too. Mostly behind finished walls. Going to replace whenever a room needs to be painted. Doing the upstairs bathroom now.
@PROSDIY
@PROSDIY 3 жыл бұрын
Nice! We are pretty much tackling it the same way. I'm going to replace them as I renovate or paint each room as well. Good luck on your projects. Cheers!
@fearfacts755
@fearfacts755 2 жыл бұрын
Great demonstration in detail. Thanks for sharing the knowledge. Good job.
@tomgarges7045
@tomgarges7045 2 жыл бұрын
Thank you for the examples of errors. Very helpful
@JeffLifeInReview
@JeffLifeInReview 3 жыл бұрын
You earned a subscriber. This video was more helpful than you know. I am hoping you have some videos about connecting from the rough to an island sink. How to connect the drains properly with traps and a proper island vent?
@itsraheem
@itsraheem 2 жыл бұрын
Yes I agree
@joseglez4741
@joseglez4741 Жыл бұрын
Is always some kind of history teller about safety 😂😂
@mattwaters6987
@mattwaters6987 3 ай бұрын
This was a great video. Nicely done. 👌
@ielwyab
@ielwyab 2 жыл бұрын
Like your video and super clear instructions. Just one comment as I learnt from other videos that Pex could not start for UV; i.e. sunlight.
@wadethomas1043
@wadethomas1043 3 жыл бұрын
I coughed up my drink when you drank from the poly b after cutting it. Lol. Hilarious.
@PROSDIY
@PROSDIY 3 жыл бұрын
Lol, Glad you enjoyed it! Cheers!
@wadethomas1043
@wadethomas1043 3 жыл бұрын
@@PROSDIY no problem. Great video. Curious.... I've read multiple conflicting information on safety of pex for drinking water. Also whether to use sharkbite push adapters. Thoughts?
@PROSDIY
@PROSDIY 3 жыл бұрын
I haven't read too much into PEX safety to be honest. It's pretty much the normal in new construction though. I personally only use sharkbites for temporary emergencies. Mainly because of the cost of the fittings. That being said sharkbite (push-fit connections) have been around for a long time (30+years). I've seen some leak, but no more common than a poor solder joint or bad PEX connection. Personally I think they have proven themselves to be a reliable fitting. Will the o-ring fail at the 50 year mark? Only time will tell, but I don't think so. I know some jurisdictions that trust them enough that they allow them on their main water supply lines to the water meter. That's saying something.
@danabrown7822
@danabrown7822 3 жыл бұрын
Much appreciated! Have a great one.
@ArmchairRamb0
@ArmchairRamb0 Жыл бұрын
Thanks, very helpful.
@notcharles
@notcharles 3 жыл бұрын
Curious, why did you hang your new piping below the furring strips?
@PROSDIY
@PROSDIY 3 жыл бұрын
Good question. There's so much already hanging below them, that when I decide to finish that room, I'm going to install a dropped ceiling.
@jeepsblackpowderandlights4305
@jeepsblackpowderandlights4305 2 жыл бұрын
@@PROSDIY so you went from 80s poly b to modern piping, then youre gonna go retro and ugly with drop in ceilings lol.. yuck.. why not just frame with 2x4s and do drywall ? Our house was built in 93.. has poly B, and dropp ceilings.. those things are going... not sure if ill replaced the poly B though, were on well water, and i have the 3rd gen poly B with metal fittings not plastic elbows and such. Im not too worried about poly B leaks on well. But redoing piping isnt that hard.. so i guess i might as well if im going to dry wall. The MAIN reason though why i would replace poly B isnt because im paranoid about leaks.. but more so water pressure.. I have to keep my pressure tank at 45 psi.. any higher say 55psi, and i risk the poly b bursting, so water pressure isnt too great.
@scionofliberty2967
@scionofliberty2967 Жыл бұрын
Excellent. Thank you.
@claycannon2818
@claycannon2818 3 жыл бұрын
very informative video ! I have poly quest pipe which is failing all thru the house !!
@billsmith9249
@billsmith9249 2 жыл бұрын
first time here, subsribed! You definitely know your stuff very well! I am hoping you have the time to answer 2 questions for me: 1. I bought a house which is done mostly in pex B. I bought a milwaukee Pex A expansion tool from a retired plumber. I would like to do some remodeling under my sink using Pex A (currently, they have pex b going to below the sink in the crawl, then they transition to copper to come up through the floor for some reason). Question: What kind of transition should I be using? I want to use Uponor Pex A fittings. 2. If I remove the existing copper coming up into the fixtures, shower, etc.., and just have the short copper run after the main incoming water shut off ball valve, do I have to worry about 'arrest' issues? I think I know what that is, it is when you go to use the water, or turn it off, and you can hear the "thump". If you're near Toledo, OH, can I hire you for a few hours? lol
@garyring8306
@garyring8306 3 жыл бұрын
how is that pipe holding up in all that window sunlight coming in? pex is very ultraviolet sensitive regardless of the type if i am not mistaken.
@JosePerez-kn5cu
@JosePerez-kn5cu 3 жыл бұрын
great knowledge thanks for sharing
@kyfeam
@kyfeam 3 жыл бұрын
awesome.. our mobile home is a PolyB nightmare.. got all the PEX just not looking forward to installing it under our trailer.. i'm 52 and not as flexible as i used to be :)
@PROSDIY
@PROSDIY 3 жыл бұрын
That does sound like a nightmare. Trailers add an extra challenge for sure. Good luck on your replacement!
@AntLive29
@AntLive29 2 ай бұрын
Proper video!
@geejay2717
@geejay2717 3 жыл бұрын
You had some great suggestions!!! Thank you.
@bunhead8
@bunhead8 3 жыл бұрын
excellent video, thank you!
@dertwerst
@dertwerst 2 жыл бұрын
Looks so nice!
@simonlarkin2539
@simonlarkin2539 Жыл бұрын
Very slick!
@rockomapaw13
@rockomapaw13 3 жыл бұрын
outstanding video...learn a lot
@chipsun2504
@chipsun2504 Жыл бұрын
Thanks, what’s that plate thing at the bottom of the sink holding the hose?
@jamesclab1
@jamesclab1 7 ай бұрын
Helpful info!
@lxmzhg
@lxmzhg 2 жыл бұрын
The reason why the hot copper line is always shinier than the cold, is because of condensation. Condensation on the cold water line, which doesn't occur on the hot, causes oxidation/corrosion.
@GaryYoung-eq1ph
@GaryYoung-eq1ph Жыл бұрын
Is it better 2 have a straight flex hose attachment than a curved one or doesn't matter? My copper pipes stick out from bottom not from wall which they always show.( 2nd floor condo) and sell.
@shivraj67
@shivraj67 2 жыл бұрын
Awesome video. The crimp rings that you're using seem to be convenient by being a pretty snug fit and not sliding around on the pipe. Do you pre crimp them?
@PhobiaOS
@PhobiaOS 3 жыл бұрын
Great video Pros DIY!
@tomlevandoski
@tomlevandoski 11 ай бұрын
Do you hook into the old water line?
@driftsdragsdrives4938
@driftsdragsdrives4938 2 жыл бұрын
Awesome video man! However I had to pause it at 8:44 and come down here because I'm not an electrician nor am i a plumber but the jagged cut tin against that 14-3 wire there seems a little nightmare material 🤣
@1huishi
@1huishi 2 жыл бұрын
Thanks . Our house has in-floor heating using poly-b and replacing is a huge pain as all floor has to be damaged . Do you have any other idea ? I am just wondering if I can insert a smaller size of PEX into existing poly-b tube to replace ? Cheers
@thomashunt6000
@thomashunt6000 2 жыл бұрын
I'm new to plumbing and learning on the mobile home I just moved into, after discovering two leaks and that it's a lot of polyb piping which I've now read is extremely prone to leaking. Will be slowly repiping and putting PEX in. Just curious, is there a reason for using crimp rings instead of cinch clamps? The supply valve that I replaced in the bathroom I used Teflon tape and a cinch clamp to secure. Is this incorrect?
@joeyjennings9548
@joeyjennings9548 3 жыл бұрын
i had steel braided line let go. spraying right thru the steel. the inside line just fell apart. seems today the quality look hides where the manufacturer cut cost on?
@friedel8338
@friedel8338 2 жыл бұрын
Very helpful thank you!
@vachibal3553
@vachibal3553 2 жыл бұрын
Thank you !
@difarr1618
@difarr1618 3 жыл бұрын
Hi... Would you say using a curved 90 is better for end pressure, as opposed to an elbow fitting 90?... Using 3/4 pex...Thanks...
@dottiemarkland9069
@dottiemarkland9069 Жыл бұрын
Yes I am a senior citizen I live in a trailer so I have to go crawl from the front all the way to the back underneath the trailer to turn the water on and off and before I started the Water Project I had to put the skirting back up so my hands are all cut up to and I got bandages all over them don't forget the senior part
@byronewhite
@byronewhite Жыл бұрын
Avoid the solder joint use compression and that way the DIY will not burn down the house. :)
@rolande5043
@rolande5043 Жыл бұрын
Great video instruction. Should I run 3/4 pex all the way to my sink (upstairs kitchen same as your layout) and then find a 1/4 stop valve to faucet lines? I Want to get more water volume. OR it doesn't matter currently 3/4 pex runs about 3 feet from faucent and is reduced to 1/2 copper to faucet line. Basically I am asking does it make sense to replace 3 feet of 1/2 copper with 3 feet of 3/4 pex to get more water volume
@weelgunny
@weelgunny 2 жыл бұрын
An old license plate for a heat barrier works for me every time.
@atashalynn
@atashalynn Жыл бұрын
Ty u just saved my ass
@MrMarbles0Xecution
@MrMarbles0Xecution 2 жыл бұрын
4:15 🤨🤔😟🤢😖😮‍💨😕 .. .. I just read a comment about you drinking some too.. I.. I can't handle this. Good day sir. be safe.....
@frankish5314
@frankish5314 3 жыл бұрын
I think the root cause of PB failure of the pipe itself is not embrittlement, its a slow chemical interaction of the chlorine in the water. We have a rental trailer on well water (no chlorine obviously) that is 26 years old and the PB pipe is pristine condition. I have replaced a few section due to leaking valve stems and the PB pipe is pliable. Now the fittings came in both plastic and copper. I have the copper ones, but I think the plastic fittings may have been failing when going brittle.
@PROSDIY
@PROSDIY 3 жыл бұрын
I'm just quickly summing it up. There are many studies due to the thousands of lawsuits. A common one is that UV light caused damage prior to installation, which I tend to believe. In Canada where all the piping is stored indoors prior to purchase (winter) they had a lot less issues than in the USA where the piping was far more likely to be sitting outside either at the wholesaler, or at the job site. You're right. There are still 1000s of homes that have poly-b that still seem in great condition, I'm glad yours is one of them.
@frankish5314
@frankish5314 3 жыл бұрын
@@PROSDIY Haha.. Yeah me too..:). Actually the UV degradation theory is entirely plausible as well.
@jcd13able
@jcd13able 3 жыл бұрын
My mobile home has that poly b pipe. It also has plastic connectors that either leaked or broke due to being brittle. The only problem with a pinhole leak occured in the hot water heater line. Then the water sprayed on the wall socket which almost started a fire under the house. The breaker tripped but some sparking still happened as the socket was black. I'm going to be replacing poly b with pex which also has problems with chlorine but it should last at least 50 years. I already use some sharkbite connectors for couple years and no leaks so I might install all 16 of them when I redo the lines. I don't trust crimp on connectors as some came undone already. Also, it's easier to replace a bad sharkbite connector than crimp the connections.
@frankish5314
@frankish5314 3 жыл бұрын
@@jcd13able interesting. I agree on the PB plastic connectors going bad. On the PEX crimp rings there are two types. The ones that are the black copper rings that are crimped like the ones on the PB pipe.. I've never had any of those fail in the 300 or so I have done. Have you checked your crimper is working right?.. i.e did you check the finished crimp with the go-nogo gauge that came with the tool? I have not used the other type of metal crimp the one where you just squeeze the edge of the stainless steel band. The other option is to use type A PEX where you use the expansion tool and the pipe/PEX ring shrinks back down on the fitting. Those work very well too, but the extra cost of the pipe/tool may not be worth it for 16 joints. Note, NEVER use an expansion tool on type B pex, which is the standard Home Depot stuff.. Crimp rings only with type B.
@1sthawkfeathers547
@1sthawkfeathers547 Жыл бұрын
I am attempting a redo on 1988 Fleetwood. The Grey pipe has not leaked. Tenants (caretakers) of property were hoarders and allowed the home to deteriorate. It will be a tear down to the studs. I might as well replace while I am there. 😊 Thank you for the advice.
@BFArch0n
@BFArch0n Жыл бұрын
Why no teflon on the connections?
@spartaeus
@spartaeus 2 жыл бұрын
I never had any trouble with PB. I'm pretty sure it was one company getting rid of it's competitor
@MrTooTechnical
@MrTooTechnical 3 жыл бұрын
great vid. you removed the dahl valve! :(
@PROSDIY
@PROSDIY 3 жыл бұрын
Lol I know, I'm sad too. I typically only buy dahl valves but my local supplier has them on backorder.
@censortube7160
@censortube7160 5 ай бұрын
@ 3:51 Whoever wired that house was not a qualified electrician, wires run under the strapping. 😢
@dottiemarkland9069
@dottiemarkland9069 Жыл бұрын
I'm old and I've been working on this Plumbing for three days I'd appreciate it if you'd come help me out with underneath must think it's killing me thank you
@Iam_jardow
@Iam_jardow Жыл бұрын
There was enough slack in that initial install for 20 sink replacements
@stevenmoomey2115
@stevenmoomey2115 3 жыл бұрын
I hate those nail in hangers, he’s using. About every has broken, and I’ve had to yank the nails out, replaced every one with the Black Loop Clamps, screwed in.
@michaelholliday100
@michaelholliday100 3 жыл бұрын
Way.... to much heat when soldering, the flux will burn and the solder will not adhere properly....
@adrowsypoet
@adrowsypoet 3 жыл бұрын
Can you do it on low heat?
@michaelholliday100
@michaelholliday100 3 жыл бұрын
@@adrowsypoet You always want to use the torch wide open. But you need to apply the solder as soon as the solder melts. Overheating the joint will burn the flux and will cause many undesirable issues...
@kristoforkolumb4158
@kristoforkolumb4158 Жыл бұрын
Это очень всё ужасно.
PEX Manifold System: PEX Water Lines
13:47
Pros DIY
Рет қаралды 28 М.
How To Stub Out PEX Plumbing for PEX-A & PEX-B
8:23
Fort Knox Co.
Рет қаралды 223 М.
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН
The selfish The Joker was taught a lesson by Officer Rabbit. #funny #supersiblings
00:12
Funny superhero siblings
Рет қаралды 11 МЛН
How to Connect a Kitchen Sink Drain
11:08
Pros DIY
Рет қаралды 2,8 МЛН
PEX Pipe Installation - ALL Connections To Fittings In A WHOLE HOUSE!
21:43
The Excellent Laborer
Рет қаралды 2,5 МЛН
It's a Disaster...
47:02
Home RenoVision DIY
Рет қаралды 376 М.
How to install PEX pipe and fittings
5:26
Apollo by Mosack Group
Рет қаралды 548 М.
DIY Kitchen Plumbing 101 | Connecting Plumbing & Mounting the Sink
37:35
Home RenoVision DIY
Рет қаралды 506 М.
How to Size Your Water Lines (PEX & Copper)
17:33
Williams Plumbing & Heating
Рет қаралды 234 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
How to Install PEX Pipe: Easy DIY Tutorial for Beginners | Step-by-Step Guide
34:30
PEX Installation Methods
12:17
Plumbing Solutions, LLC
Рет қаралды 468 М.
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН