INSTALLING THREE PHASE 22KW CAR CHARGERS AT HOME! - Electrician Life

  Рет қаралды 131,243

Artisan Electrics

Artisan Electrics

Күн бұрын

A THREE PHASE 22KW EV CHARGER AT A DOMESTIC PROPERTY?
Can you install a three phase 22KW electric vehicle charger at a domestic property? In this episode of Artisan Electrics Jordan & Cory are going to answer that exact question. They also walk you through a three phase installation and show you how you can identify three phase power at your property.
VIDEO SPONSOR - Tradify 📱
Get 50% Off your first 3 months with Tradify using our discount code "ARTISAN" here: bit.ly/3HuCNPl
Subscribe to our KZbin Channel for more great electrical content: kzbin.info...
Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
⏱️Timestamps
00:00 Coming Up
00:23 Three Phase Question
01:11 Distribution Board
02:21 Metre Box
04:52 RCD Planning
06:14 Cable Route
07:48 Artisan Tip Of The Day
08:43 Audited Again
11:04 What Is This
13:45 Having A Thought
14:51 Artisan Strenght
16:09 TRADIFY
16:59 New Breaker
18:36 Wiring Up
20:13 Another Job
22:09 New Socket
23:03 Ouch!
🧰🛠️ Tool Of The Day 👇
Unilite Work Lights:
Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
🏷️😱 Big Boots - get 5% off our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
-----Electricians Business Course-----
📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS KZbin Channel 👇
I Also Have A Dedicated KZbin Channel About Tools:
➤ / tools4sparks
-----MY ENERGY PROVIDER-----
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📈Make the most of your KZbin analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер: 415
@artisanelectrics
@artisanelectrics 2 жыл бұрын
VIDEO SPONSOR - Tradify 📱 Get 50% Off your first 3 months with Tradify using our discount code "ARTISAN" here: bit.ly/3HuCNPl
@geraldelwood9660
@geraldelwood9660 2 жыл бұрын
Tip for Corey. Once you have drilled pilot holes in mini C.U. offer it up to partner enclosure (3 phase box) and mark the hole position through existing pilot hole. Perfect alignment without messing around to find centre of circle.
@gajnjaca
@gajnjaca 2 жыл бұрын
That "black paint" is probably hidro insulation of the exterior wall, drilling that low risks compromising the insulation and bridging the water or humidity entry to the house
@mikescott58
@mikescott58 2 жыл бұрын
Hi guys, Yankie viewer here. I love the channel. Electricity/electronics have fascinated me for as long as I cn remember. You were wondering about how the 110V worked. Here in North America (US specificlly) our mains for residential service is 220 V, singls-phase, though, in relity nominally more like 240 V. Unlike there, neutral is not referenced to either leg, but rather a center tap. This gives us 120 V from one leg to neutrl for most things like lighting, plug sockets, and small appliances. Larger items like air conditioners, cookers, elecctric dryers (and, of course, EV chargers) connect across both live leads for 240V. Earth is typically bonded to neutral at the main panel (consumer unit) and to the cold water supply where it enters the building. Also our plug sokets are typically fused at 15 A and 20 A for kicchen appliances. Probably a good thing I grew up here rather than there given the number of times I have gotten shocked, 240V / 32A probably would have killed me. :-)
@johnburns4017
@johnburns4017 2 жыл бұрын
We have RCD protection.
@katomate4300
@katomate4300 2 жыл бұрын
How do you not get ripped to shreds on sites with that scarf man
@chrisgoodwin3617
@chrisgoodwin3617 2 жыл бұрын
Hi Jordan, you've got a fantastic team and they genuinely like you. You are an example of an excellent boss. Chris. Northampton.
@artisanelectrics
@artisanelectrics 2 жыл бұрын
We do like him!!
@nusermane1076
@nusermane1076 2 жыл бұрын
Finally a 3p domestic installation 😍😍 Thank you for doing this project 👍👍👍
@sciencetestsubject
@sciencetestsubject 2 жыл бұрын
I had 3 phase 25A installed last year coming from single phase 35A quite an improvement. It only cost €300.
@paulf3353
@paulf3353 2 жыл бұрын
Welcome to the UK. You'll pay a fortune for any labour here.
@michielderomijn
@michielderomijn 2 жыл бұрын
Upgrading from single to three phase supply costs only €300 in the Netherlands. That's possible because all supply cables and incomers here are three phase, so the DNO only has to add two fuses and swap the meter.
@black.phoenix.
@black.phoenix. Жыл бұрын
Same in Portugal. My grandparent's home is a 3 phase instalation because of 2 drilled wells with submersible pump inside (both at 30m depth).
@julien801
@julien801 2 жыл бұрын
I'm electrician in Quebec, Canada and love watching you guy's, good work every time ! here residential is 120/240v 1phase and industrial and commercial is 347/600v 3phase. have a good day !
@dominicmcgonigle9500
@dominicmcgonigle9500 2 жыл бұрын
That is mostly the same in the UK are residential is normally 240 single phase this house is however one of the exceptions
@julien801
@julien801 2 жыл бұрын
@@dominicmcgonigle9500 120v L1+N or L2+N is for light, outlet and 240v L1+L2 is for heater, coocker, dryer etc
@MrKnatterton
@MrKnatterton 2 жыл бұрын
@@julien801 Ah ok , it's like in the US? 240V is splitted in 2*120 at the transformer, then 240 and 2*120 ist going in to the House? Here in Germany every privat building has 400V / 3 Phases 240V, mostly 63A. A Charger with 11kW is normal, if you like to install more then one or one with 22kW you must ask the network operator bevor installing.
@stephenjones9153
@stephenjones9153 2 жыл бұрын
@@MrKnatterton I always tell my family and friends about how clever the Germans are and very sensible. Her in Liverpool we even have a great German Manager in Jurgen Klopp 😊👍👍
@gonzo_the_great1675
@gonzo_the_great1675 Жыл бұрын
I enquired about getting 3ph to the house for running workshop machines. But the DNO told me that only 2 phases came down the street, with properties alternating between those 2 phases. To add 3ph they would have to run a custom feed from the substation. VFD's on the machines was cheaper!
@benjaminc1816
@benjaminc1816 2 жыл бұрын
I’m having a new build house built at the minute (due to move in around August time) and managed to get a 3 phase supply fitted as an extra (it cost me £1200 but well worth it in my opinion) - there will be a 3 Phase DB in the garage for machine tools / 22kw car charger and L3 will run from that to the house and feed a standard Hager Consumer Unit - thought it best to upgrade and future proof - so for anyone else looking at new builds, it’s well worth asking as its a lot cheaper then doing retrospectively (although they didn’t have a clue what it was asking for until i drew them an electrical plan and spoke to their electrical contractors ) - I’m baffled to why that house has a US 110v split phase system though - are they an American family who didn’t want to replace all their appliances? If so then the fitting of the 110v points must have cost more then replacing the appliances.
@stevendavies4572
@stevendavies4572 2 жыл бұрын
Sounds like you've had a bargain there.i spoke to a chap who had to pay 40k to get it installed.
@benjaminc1816
@benjaminc1816 2 жыл бұрын
@@stevendavies4572 I think because I’m getting a new build and they had to run a mains feed in anyway it was cheaper - there’s 3phase in the road so the only cost is the cable and paperwork - with the way the world is going now with heat pumps / EV’s / aircon etc I thought it best to future proof - I’d recommend anyone getting a new build to push for 3phase as I expect it will be the norm in 5 years
@dennybaker8755
@dennybaker8755 2 жыл бұрын
Thats very expensive . . . Hope its made of gold 😂
@havoctrousers
@havoctrousers 2 жыл бұрын
There isn't a scenario where those 110V points make any sense to me. Shipping appliances to the UK would be stupidly expensive, never mind setting up a dedicated 120V board, transformer and accessories. There are very few appliances that would need exact US supply characteristics, the only things I can think of being motors where the AC frequency is used for the functionality (clocks, tape decks, VHS recorders and turntables) and you could just buy 50Hz UK versions. They must need that 120V/60Hz for *something* ? Maybe as part of the building's previous purpose they had a lot of US visitors with their own devices?
@patdbean
@patdbean 2 жыл бұрын
@@dennybaker8755 I would think the cost of a 3 phase service basically comes down to the distance from the 3 phase main to the service head and how much trenching is needed.
@ForTheBirbs
@ForTheBirbs 2 жыл бұрын
Nice new intro guys! This mystery 110 install has everyone talking.
@cumberland1234
@cumberland1234 2 жыл бұрын
I don’t think the 120v will be centre tapped earth as the RCBOs only look to be single pole, I wonder if transformer is a frequency converter too as it looks expensive!
@xNYCMarc
@xNYCMarc 2 жыл бұрын
In the US and Canada (since we are on the same grid with each other), the electrical system is 240 volt with a center tapped transformer. The neutral is center tapped and bonded to earth. Neutral to one of the hots will give 120 volts. Hot to hot without the neutral will give 240 volts.
@nmccw3245
@nmccw3245 2 жыл бұрын
Yes, that looks more complex than a simple step down transformer. I bet it’s a rectifier / inverter delivering 110V 60Hz or even center tapped 220V.
@Havoc4Hire
@Havoc4Hire Жыл бұрын
9:36 That wrench blew my mind
@sk83rboy00
@sk83rboy00 2 жыл бұрын
Memshield offer a 3-phase type a RCBO with 30ma. It takes up 4 ways but the 4th pole is blanked and insulated away from the busbar. You could have shifted some breakers down and saved putting in an external RCD?
@Liberator975
@Liberator975 2 жыл бұрын
Love seeing you on the tools Jordan 💪💪
@tudorwilliams5454
@tudorwilliams5454 2 жыл бұрын
Here in South Wales I’ve worked on a few domestic jobs lately and western power have been replacing all the supply’s in the street to three phase ready for electric chargers in the future
@JustMeTalking
@JustMeTalking 2 жыл бұрын
We had 3 Phase fitted onto our 1996 built UK detached home for free. Currently running two Zappi Chargers, 1 x 7kW and 1 x 22kW on 3 phase. Very nice 👌
@owenwilson3750
@owenwilson3750 2 жыл бұрын
Whos ur provider if u dont mind me asking?
@shitgetugly
@shitgetugly 2 жыл бұрын
How did you get it installed for free?
@JustMeTalking
@JustMeTalking 2 жыл бұрын
@@owenwilson3750 Western Power
@JustMeTalking
@JustMeTalking 2 жыл бұрын
@@shitgetugly We were on a Looped Supply with our Neighbour. They wanted to remove it first, and I asked for 3 Phase instead. As they were already going to do the 'unloop' for free, they agreed.
@imprezaaudi
@imprezaaudi 2 жыл бұрын
Ive just had fitted 3 22kW Zappis on my new property. It has 100A 3phase. I understand the Master Zappi controls the total load demand across all 3 Zappis
@simonashcroft7343
@simonashcroft7343 2 жыл бұрын
Job well done lads, I have made the same mistake myself with glanding off one end of my nyyj cable before feeding it behind drain pipes etc, I only did it once the. Nice and neet job.
@Ted_E_Bear
@Ted_E_Bear 2 жыл бұрын
Thanks for sharing the video !
@ruane1995
@ruane1995 2 жыл бұрын
I wonder if this was owned by someone from USAF that was based in the UK..
@HenryLoenwind
@HenryLoenwind 2 жыл бұрын
Probably (originally) owned by the forces to be rented out to officers. We have plenty of those around here in Germany. Housing on-base with central dual-voltage supply for the normal soldiers, but officers get their rank-appropriate stand-alone houses.
@JasperJanssen
@JasperJanssen 2 жыл бұрын
with the cars mentioned and the tires shown I’m thinking more jetset celebrity. Even generals don’t really get paid Porsche Huaycan money, do they?
@owenwilson3750
@owenwilson3750 2 жыл бұрын
@@JasperJanssen fuck man you could even buy a pretty fast bike for the 12 extra rims alone xd
@nmccw3245
@nmccw3245 2 жыл бұрын
@@JasperJanssen - not until they retire into a sweet political position with kickbacks or a corporate lobbyist gig. 😜
@andrewpowell6457
@andrewpowell6457 2 жыл бұрын
Nice to see you out & about Jordan
@beeson514
@beeson514 2 жыл бұрын
Corey can you leave Jordan at home next time please.
@williedeklerk7287
@williedeklerk7287 Жыл бұрын
So weird we use the same three phase electric meters in S.A/Namibia . 😎
@johnprentice5862
@johnprentice5862 2 жыл бұрын
I have domestic 3-phase and a little known implication is not all energy suppliers have 3-phase SMETS meters (e.g. OVO - badgered me into a smart meter and when the technician turned up to fit the meter he said "Oh it's 3-phase we don't do that!" I said that I told the person booking the "upgrade" so they ended up giving me £30 for having wasted my time). Not yet a problem but the time will come when you can save money with smart-based tarrifs.
@hithere2546
@hithere2546 2 жыл бұрын
A three phase is actually 'normal' here in the netherlands, but they usually dont go above 35 amps, but with loadbalancing you can also place a 22kw.
@hithere2546
@hithere2546 2 жыл бұрын
For info 3 phase here is also 230/400v
@benjaminc1816
@benjaminc1816 2 жыл бұрын
In the US, the 110v is a centre tapped 220v supply - centre is earth referenced neutral and each live is 110v to neutral - their bigger appliances (dryers / HVAC etc) uses 220v as it feeds from both lives, and the generic appliances just use 110v - benefit is if you touch one live then the worst you’ll get is 110v through you - but the downsides are they need thicker cables as amperage is higher for the same wattage appliances on 240v - they have less protection in the board RCBO’s / AFDDs etc - but at least they don’t know the excruciating agony of standing on a UK 3 pin plug when walking through the house to go for a piss in the dark 😂
@steveb1856
@steveb1856 2 жыл бұрын
I was going to say that!
@benjaminc1816
@benjaminc1816 2 жыл бұрын
@@steveb1856 Ha! Sorry! I’m still baffled why someone would want their UK house wiring to US spec though! I’m intrigued!!
@michaelholliday100
@michaelholliday100 2 жыл бұрын
Hey we do not have 220 volt power in the US. We have 120 volts, 240 volts and 208 volts... In the US most houses have single phase L1, L2 Neutral and Ground. L1 or L2 to Neutral = 120 volt service and L1 to L2 = 240 volt service. Most major appliances in the US like Air Conditioners, Ovens, Clothes Dryers and Hot Water Tanks are 240 volts.
@kenrohde6841
@kenrohde6841 2 жыл бұрын
@@michaelholliday100 Roughly, UK nominal voltage was 240v but was changed to 230v to harmonise with Europe which was at 220v nominal. Actual voltage will be in quite a range. In the UK, the declared voltage and tolerance for an electricity supply is 230 volts -6%, +10%. This gives an allowed voltage range of 216.2 volts to 253.0 volts (so the former 240v nominal is still within the normal range, that is also reason it is only -6% as the lower bound is the same one as when the declared voltage as 220).
@ib9rt
@ib9rt 2 жыл бұрын
@@kenrohde6841 "Roughly, UK nominal voltage was 240v but was changed to 230v to harmonise with Europe" -- except it was not actually changed, the UK supply voltage is still 240 V same as it was before. There was no need to change it as 240 V lies quite well within the 230 V + 10% range. Michael Holliday is also quite correct that the normal supply voltage in the USA is 120 V not 110 V, with 240 V available for large appliances.
@neilburton100
@neilburton100 Жыл бұрын
Very informative for somebody who is also scoping out a 3-phase connection and 22kW charger. I thought I was the only person on this island with a garage full of winter wheels!
@waqasahmed939
@waqasahmed939 6 ай бұрын
The issue with the 22 kWh chargers is that most cars can only pull 11 kWh via AC So for most people it isn't quite worth the upgrade
@neilburton100
@neilburton100 6 ай бұрын
@@waqasahmed939they’ll become more common as electrical demands evolve. I went ahead with an upgrade and its proven to be extremely worthwhile now whilst undoubtedly a good future-proofing measure. The key for me is being able to charge 2 cars simultaneously at 11kW each, within a time limited off-peak charging window. More cars will support 22kW in the future. I currently have one (iX M60) and although its a rare requirement its been very handy to be able to charge it that quickly on my own drive.
@phil2pips
@phil2pips 2 жыл бұрын
Haha 13:10 'when the apprentice becomes the master' look
@robertwillcox2799
@robertwillcox2799 2 жыл бұрын
Very interesting video, looking at your audit @ 16.38 minutes i note 6mm cable for a 25 m run, other web sites suggest 10mm plus ? Any opinion please, thankyou.
@frimleyfrodo
@frimleyfrodo 2 жыл бұрын
Surely if Cory prematurely glanded one end, rather than pull the whole coil through the wall, why didn’t you just remove the gland from the board and fit it to the charger and thread the unmade end back through the hole, gland it and fit it to the board? Or have I missed something obvious?
@matthewdale956
@matthewdale956 2 жыл бұрын
Thinking the same 🤔, must of been more to it
@JC-jv5xw
@JC-jv5xw 2 жыл бұрын
What was in the board on the far right? Looks like it was intended as expansion for the main 3ph board as it does not appear to have an incomer. Could you have fitted an RCBO in there?
@effervescence5664
@effervescence5664 2 жыл бұрын
Interestingly when I first enquired with Anderson you can apparently fit the 22kw changer on single phase and it will work due to being the same charger. It's just the connector and out going lead which is different. A good option for homes that can be upgraded to 3 phase but already have a set date for delivery before hand etc. It's also the charger recommended by the Porsche dealers for the Taycan.
@havoctrousers
@havoctrousers 2 жыл бұрын
I've fitted the Schneider EVLink ones and they're the same. They don't have a tethered lead so you can use the 3P lead that came with your car for single or three phase. Ultimately, all these EVSE devices are really doing is using a contactor to link the incoming lines to the pins in your type 2 charging connector (the 3 horizontal middle pins of the type 2 connector are L1-L3) and the car is doing all the work of AC->DC. The EVSE doesn't really care whether just L1 or L1-L3 are connected although it will have an internal CT on each line for metering. Like you said, if the tethered lead is only 1P (cheaper and less copper) then it needs changing.
@effervescence5664
@effervescence5664 2 жыл бұрын
@@havoctrousers Oh I just meant from the pov that some manufacturers aren't actually using the same internals across the 1p/3p versions, either different contactors or actually no terminals for the extra phases. Not fitted the Schneider, we tend to fit the Zappi and Anderson as the main 2 with Hypervolt becoming popular mainly due to Jordan's channel here. I have a feeling that once the world stops being in such chaos all chargers will just be supplied 3 phase compatible as standard, especially as they're considering making all current homes where possible 3 phase to help with the transition to renewable - whether that comes to pass or not we'll see.
@johnburns4017
@johnburns4017 2 жыл бұрын
@@havoctrousers EVSE, another acronym to confuse and keep guys in the _club._
@stephenjones9153
@stephenjones9153 2 жыл бұрын
I imagine it would be really easy and fairly inexpensive to get 3PHASE supply in an old terraced house. Just run a phase from each neighbours supply. Most streets have 3 phase running under the pavement.😉
@jamieblatantsparky
@jamieblatantsparky 2 жыл бұрын
So the house is definitely a current or former USAF safe house for offsite secure comms in the event the base was bombed or placed out of action it’s all to USAF Europe specs and probably contains a load of bits we don’t get to see unless they ahe been removed , I am guessing it’s been sold off because there is no way filming would be filming place if it was still USA property
@farmersteve129
@farmersteve129 2 жыл бұрын
Seen plenty of similar installations that are nothing to do with USAF or US government, a safe house would not have a visibly obvious 110V system with yankee plugs everywhere. Some Yanks just like their own stuff... even though it comes out of a the same plant in Shenzhen...🤣🤣
@jamieblatantsparky
@jamieblatantsparky 2 жыл бұрын
@@farmersteve129 Thete are a few other things I’ve spotted that lead me to belive it’s not a normal house
@tonybutterworth1221
@tonybutterworth1221 2 жыл бұрын
Hi all at Artisan Electrics I’am not an electrician but watch your videos all time I like your work ethic. I have question, I have a 32amp round pin with switch on the outside wall for when my son visits to charge his Tesla, can I use one of those round pin extensions to 13 amp socket for use on electric mower??
@CrownRider
@CrownRider 2 жыл бұрын
Most modern homes in the Netherlands have three phase power (230/400 Vac). The main breakers are 25 or 50 Amp. When charging an EV with e.g. a 90 kWh battery, at night, with 22 kW from 35 to 85% SOC, that takes 2 to 2.5 hours. So it's ready before you go to bed. A bit over the top don't you think?
@thecooletompie
@thecooletompie 2 жыл бұрын
Yeah I was kinda surprised to learn most british homes do not have 3 phase. Don't they have any 380-400V appliances over in the UK.
@cmjones01
@cmjones01 2 жыл бұрын
@@thecooletompie Generally only industrial and commercial appliances are 3 phase in the UK. Domestic properties just have high current single phase supplies. 100A single phase is not unusual (my own, quite small, house in the UK has a 100A supply), and even high power appliances like instant water heaters for showers (up to 13kW, 55A at 240V) run from single phase. I now live in Poland and most houses here have 3 phase supplies but only 25A per phase, so large appliances have to use all three phases.
@johnburns4017
@johnburns4017 2 жыл бұрын
@@cmjones01 11.5kW was the maximum on a single phase supply - last time I looked.
@njipods
@njipods 2 жыл бұрын
@@johnburns4017 there is no limit on single phase. As long as the wiring is up to it and the network is ballenced.
@johnburns4017
@johnburns4017 2 жыл бұрын
@@njipods In the UK 11.5 kW for a single appliance
@ronan4853
@ronan4853 2 жыл бұрын
Just wondering do ye install load management clamp on clamps to monitor the loads of each phase , and if so how does it link to the charger
@heladas90
@heladas90 2 жыл бұрын
Looks like they haven't on this one which is a bit crap as this house has a bit of load on it. You would install a cat 5 cable from the chargepoint to the main tails of the house just after the electricity meter.
@Paul_Holmes
@Paul_Holmes Жыл бұрын
I would have un-glanded the cable and make Cory re-gland it after passing through the wall 😄
@MB-alarms_and-more
@MB-alarms_and-more 2 жыл бұрын
Awesome video guys
@havoctrousers
@havoctrousers 2 жыл бұрын
What's wrong with Makita? They're reasonably priced and they last pretty well in my experience
@dg2908
@dg2908 2 жыл бұрын
Would you like three old drills and a vacuum to work it out for yourself?
@peterjones6640
@peterjones6640 2 жыл бұрын
I recently had a 3 Phase charger installed, I was lucky that three phase supply to the house ( many years ago the house was three separate flats), internally it had been downgraded to single phase but reasonably quick to get U.K. power networks to upgrade main fuse and Eon ( after a lot of nonesense from EOn via email telling me I couldn’t have a three phase meter, clearly a training issue for their customer department) to put in three phase meter.
@johnburns4017
@johnburns4017 2 жыл бұрын
Do you pay more standing charges for having a three phase meter?
@peterjones6640
@peterjones6640 2 жыл бұрын
@@johnburns4017 No , all charges are exactly the same as for single phase.
@metrotechguru5863
@metrotechguru5863 2 жыл бұрын
Nice job as usual, lads.
@Kevin-ij8qb
@Kevin-ij8qb 2 жыл бұрын
Western Power Distribution have started installing 3 phase cables & service heads on a lot of new connections. Often only a single phase connected but it makes the upgrade process far easier (and hopefully cheaper)
@benjaminc1816
@benjaminc1816 2 жыл бұрын
Most DNO’s are happy for new build developers to install 3 phase - my DNO is northern power grid they’ve approved me to have 3P on my new build - just a £1200 upgrade fee to the developer (bargain in the scheme of things) - 3 phase should be the norm on all new homes with 3+ bedrooms I think - a lot of countries in mainland Europe have been doing it that way for years
@computeraddic675
@computeraddic675 2 жыл бұрын
@@benjaminc1816 Yep!Since the war,they had to rebuild a lot off houses,so in every house since then the supply cable is 3 fase.But not all houses have 3 fase.But the cable is there allready.
@haldo691
@haldo691 2 жыл бұрын
It's standard now with western power you don't get the choice it's future proofing and allows for easier load balancing
@benjaminc1816
@benjaminc1816 2 жыл бұрын
@@haldo691 eFIXX Did a video about this a few months back actually and WPD was the DNO - search for “this is not a consumer unit” and you’ll find it - it’s good to see!
@haldo691
@haldo691 2 жыл бұрын
@@benjaminc1816 I work for WPD so I know about it lol
@andybell7415
@andybell7415 Жыл бұрын
A 3 phase supply upgrade starts from £1500 + VAT, just been looking into this today for a 3 phase electric combi boiler.
@CEwig84
@CEwig84 Жыл бұрын
Are you from erasure? 😄
@valzzu
@valzzu Жыл бұрын
now days most houses in finland has 3 fase circuits, there still are old houses that only have 1 fase system.
@ManiacalMichael504
@ManiacalMichael504 2 жыл бұрын
Interesting to see the 110V transformer in a home, guess they travel between North America and the UK a lot. Most common setup here is corner-tapped Delta. Wonder if that is actually split phase, seems so looking at the board. Some homes built in the 1950s here have "Stinger" 3-phase as the air conditioners of the time were only 3 phase. Vast majority of houses and even some small businesses are split phase 120V.
@toddt6730
@toddt6730 11 ай бұрын
I wonder what they are using the 110 for, it still is going to be 50 Hz as compared to American 60hz
@inspireG380
@inspireG380 2 жыл бұрын
What was the reason for the 110v bits in this place ? Curious to know !
@havoctrousers
@havoctrousers 2 жыл бұрын
and is it 60Hz like in the US? It looks like a UK 2 gang plate with US sockets in it, who makes such a thing and why? We need answers!
@nusermane1076
@nusermane1076 2 жыл бұрын
😳 have they been in British Columbia? 😁
@jayja45
@jayja45 2 жыл бұрын
@@havoctrousers MK makes them, probably most popular in hotel installations.
@imark7777777
@imark7777777 2 жыл бұрын
The UK uses a step down transformer for outdoor power equipment stepping down to split phase 120V. So it’s either for outdoor equipment or somebody who brought a lot of equipment from the US. Could also be in a US military type area. I’m assuming the giant transformer since it looks more than just a transformer is doing frequency shifting as well as voltage dropping because it look fancy. Did not know that there was a whole line of US sockets in the UK style complete with permanent installed wiring that is crazy got to know more.
@michaelholliday100
@michaelholliday100 2 жыл бұрын
@@imark7777777 The US equipment would be 60 Cycles while Great Britain is 50 Cycles. You can split the power, but you cannot change the hertz of the power. You will destroy appliances with motors especially compressors. This is because, when you run an appliance like a fridge compressor motor on a slower cycle than what it has been designed for (60 Hz frequency vs 50Hz), it will cause the electric motor turn slower. This inevitably results in an increased strain on the motor windings, causing the compressor to burn out.
@jensschroder8214
@jensschroder8214 2 жыл бұрын
22kW are rare even in Germany. The electricity supplier has to approve it. 11kW are often installed because there are subsidies up to this size and the electricity supplier only needs to be informed. The problem is only when the car wants to draw 32 amps on one phase and is limited to 16 amps because of 11kW. Then it makes more sense to install a 7 kW charger one phase with 32 amps. Or trying to get 22kW approved because that's 3x 32 amps.
@mikebosman9280
@mikebosman9280 2 жыл бұрын
Here in Denmark it is very normal to see 3x25A in a house. In our small house we have 3x35A.
@thomas.6497
@thomas.6497 Жыл бұрын
Perhaps to add some info here. In Ger a typical (house) setup is 3 phases with 63 amps each. The first fuse (3) are also 63 amps. Then the next device in the path is a Selective Switch Breaker (SSB) (I do not know how you call it in English) followed by the meter. The SSB is typically 63 amps as well under normal operation (no car charger and no PV system -> so-called intermittent operation). Then come the distribution with RCD’s (usually type A) and breakers (usually B16). So installing a 3P car charger is normally pretty straight forward. Usually you just need to add another RCD (type A) and 3P breaker. The DC 6mA residual current monitoring is usually embedded in the charger. When a car charger (and / or PV system) is installed the house operation changes to so-called duration operation and the SBB has to be changed to 50 or 35 amps depending on the meter wiring.
@thehowelldiaries
@thehowelldiaries 2 жыл бұрын
Love the new intro ✨✨
@Chris_In_Texas
@Chris_In_Texas 2 жыл бұрын
1:52 not to start a comment war, however the US outlets are upside down. While there are arguments either way, the majority of manufactures assume the ground pin is down, because that is the way all the cabling are made for the transfers and other times (charges etc). Kind of like if you guys put the ground pin down, but its our assumption here. Our larger 240V style plugs assume ground pin is up as all 90 degree cables are made that way here. 😁👍
@CoolerQ
@CoolerQ 2 жыл бұрын
It is commonly done both ways. I wouldn't say ground up is wrong. Residential is most commonly ground down and commercial is most commonly ground up. The usual argument is that commercial installations tend to use metal faceplates, and if the face plate becomes loose you'd rather have it fall on the ground pin than a live pin. Of course that's only a problem because our plugs don't have sleeved pins.
@dg2908
@dg2908 2 жыл бұрын
These US outlets on a UK sized plate are part of MK's logic plus range which curve in at the top. They definitely intended them to be fitted with the ground pin at the top as in the video
@matthewdale956
@matthewdale956 2 жыл бұрын
Us switches are upside as well 😉
@HenryLoenwind
@HenryLoenwind 2 жыл бұрын
I'd argue that ground-down is the safer configuration. When the plug rattles free, the bigger gap will be at the top, so having the harmless pin there to be exposed to touch is nicer. (Really, who thought designing a plug in a way that a live pin can be exposed to touch was a good idea?)
@RB-lt8kt
@RB-lt8kt Жыл бұрын
Always check your car maximum AC charging input as a lot of cars will only charge at 11kW max on AC. Installing a 22 kW charger could be an expensive mistake. As a Ford dealer in Cardiff found out by installing 22 kW chargers instead of DC chargers against the advice of the installers and complained why his Ford Mach E cars weren't charging at 22 kW. Perhaps the issue was the Mach E only has a 11 kw charger ? LMAO.
@arr4nn_911
@arr4nn_911 2 жыл бұрын
Awesome video
@antonymcneillis
@antonymcneillis 2 жыл бұрын
What was the kVA in the property? Did you ask the DNO to increase the kVA? Also did you/ the owner get permission : letter of authority from the DNO?
@RichardArblaster
@RichardArblaster 2 жыл бұрын
Great video 😎
@danfrance7778
@danfrance7778 2 жыл бұрын
Cables In that 3 phase CU is like Bob Marley’s hair style
@dannyquinn2
@dannyquinn2 2 жыл бұрын
Is that a Hilti multi tool at 24:04?
@scottreynolds8917
@scottreynolds8917 2 жыл бұрын
Are CT clamps required?
@TeamYankee2
@TeamYankee2 2 жыл бұрын
I'm in UK and as I have my supply looped from next door on 80amps. I asked my DNO to swap too 100 amp fuse and they said I can upgrade to 3 phase at the same time as they have to dig up the garden to run new cables..might as well put in 3 phase right??
@Saaj2
@Saaj2 2 жыл бұрын
Yes definitely. Since it's a looped supply I'm guessing it's free of charge? 100% do it! You don't necessarily need to get a 3 phase meter until you're ready.
@danjenkins88
@danjenkins88 2 жыл бұрын
Updating to 3phase isn’t always extortionate - I’ve been quoted 3k inc vat from the DNO (which is still a lot considering I have a telegraph pole at the end of my 10m driveway) - I was surprised when I got the formal quote!
@stuinNorway
@stuinNorway 2 жыл бұрын
If you have a pole at the bottom of yout garden you're lucky. We needed to upgrade as our home had a 1 ph 50A circuit, had to dig 25m up the road, plus 20m under our block paved drive, and a totally new intake box, secondary distribution box to split to car charger, and then into house with rest... It was NOT cheap, just the cabling to the house was over £10k
@chapman9230
@chapman9230 Жыл бұрын
Just got a quote and yes we are lucky too. Pole directly outside. 2.6 k but we have to dig a trench.
@sstorholm
@sstorholm 2 жыл бұрын
Rather fun that up here in the Nordics the smallest supply for a house is 3x25A, with no option for single phase anymore. I think most DNOs won’t do single phase except for technical applications, like a supply for an ISP network cabinet or something.
@arnoldsmit3289
@arnoldsmit3289 Жыл бұрын
Same in the Netherlands most common is 3X25A, and in older homes and apartments 1X35A.
@grahamnicholson1553
@grahamnicholson1553 2 жыл бұрын
Why are external small cabinets always being used to house RCD protections on your installs? In Australia we would have put in something like the Hager BD163T and kept the RCD on the board. I have been meaning to ask for a long time as it seems common in your Car Charger installs to have a separate RCBO and Breaker rather than combining on the board and with single pole it is even simpler.
@nectafarious8842
@nectafarious8842 2 жыл бұрын
I have a pole with 3 phase in my garden. I dug my own trench to the house from the pole and the MEB ran a cable into a new 3 phase/pme head in my utility room (I needed 3 phase for my garage and workshop). It cost me £350....30 years ago.... Looks like I got lucky and future proofed my gaff!
@photronsardarkling2064
@photronsardarkling2064 2 жыл бұрын
You're so smug I wouldn't mind betting you're a politician 😁
@nectafarious8842
@nectafarious8842 2 жыл бұрын
@@photronsardarkling2064 Just stating facts. Got the shovel out and got stuck in.
@photronsardarkling2064
@photronsardarkling2064 2 жыл бұрын
@@nectafarious8842 Fair play dude 😁
@BrianWrenn
@BrianWrenn 2 жыл бұрын
Should you not feed the rcd from the bottom!?
@RRIDDICC
@RRIDDICC Жыл бұрын
@2:31 eeks... the box hangs just at the outside of the house, where the fog and nebula and rain and snow and hail can reach it directly?
@david103857
@david103857 2 жыл бұрын
Thought I saw somewhere that in new builds in Wales Western Power Distribution are fitting 3 phase supplies as standard to support all these car chargers. Hopefully other DNOs will follow suit!
@wyndavies5044
@wyndavies5044 2 жыл бұрын
That is true. Only 3 phase cable and head for now and only use one phase. When the works will be cartied out on the lines, all they will have to do is connect up.
@ConstantijnKool
@ConstantijnKool 2 жыл бұрын
Sad that the hilti drill is already broken I have the same Dewalt drill as Corry had never died on me!
@andyjdhurley
@andyjdhurley 2 жыл бұрын
Wow, that's exactly the meter we have. Power companies have wanted to change the meter for a smart one several times but each time the guy has come out he has gone away again not knowing how. We have L1 and L2 into the meter with L3 not connected. L1 then feeds the main house consumer unit and L2 feeds a unit in the garden (via a secondary rotary meter). We don't own the house (church rectory) otherwise I would be inclined to get this all sorted out.
@andrewjames3908
@andrewjames3908 Жыл бұрын
With a 3 phase supply like that with 3 100A fuses is the max they can pull still 100A not 300A due to the capacity of the neutral?
@fluxcapacitor
@fluxcapacitor 6 ай бұрын
Can any 3-phase 22 kW wallbox be connected using only one live wire so it becomes a 7.4 kW wallbox on a single-phase home circuit?
@dr_jonathan_whelan
@dr_jonathan_whelan 2 жыл бұрын
Love the US 110v system. Any issues with that being signed off under the regs ? I wouldn’t have thought they would contain anything about the US wiring.
@s.kxx1956
@s.kxx1956 2 жыл бұрын
Probably just normal cabling, just like running 110v supplies from a big transformer to yellow commando plugs, the outlets may be a departure from bs7671
@JC-jv5xw
@JC-jv5xw 2 жыл бұрын
It will be fun if the 110V outlets have been wired as a ring...
@johnburns4017
@johnburns4017 2 жыл бұрын
@@JC-jv5xw No reason why they cannot be.
@nmccw3245
@nmccw3245 2 жыл бұрын
@@JC-jv5xw - the could be, but no real reason. US code requires a duplex receptacle ~ every three meters. My bedroom has 14 places to plug something in. 😜🇺🇸👍🏻
@ChopperReid88
@ChopperReid88 2 жыл бұрын
Why do you need rcd protection when you're using SWA Cabel?? 🇦🇺🇦🇺
@alanjrobertson
@alanjrobertson 2 жыл бұрын
Haha loved it when Cory part-walked into shot during the intro then realised and tip-toed back out of shot again 😂😂
@Chris_In_Texas
@Chris_In_Texas 2 жыл бұрын
2:39 So you can't request larger single phase input power? We have 400A 240V service entrance ability here, with normal 200A 240V pretty common around where I live in the south.
@billccn
@billccn 2 жыл бұрын
Will be rather expensive to create a charger that takes 91A (22kW/240V) through a single phase though. Remember the "charger" on the wall is really just a smart switch, the car itself does all the AC/DC conversion. If most cars won't take it, then there will be no market for such chargers.
@HenryLoenwind
@HenryLoenwind 2 жыл бұрын
@@billccn Strike that "most". It just isn't possible to get more than 32A of a single phase to a car with a Type2 connector. There's only N/L1/L2/L3 (plus PE and 2 data lines) in the plug and each of those contact maxes out at 32A. Putting L2 and L3 on the same phase as L1 would overload N---the only reason there's not N1/N2/N3 needed is because of the phase-shift of the phases. In theory you could do L-L1/N-N/L-L2/N-L3, but that would need some very, very good communication between car and wall box to make sure neither switches to that configuration if there's anything else connected. (Not impossible, Tesla does exactly that for DC charging in pre-CCS2 models...)
@Mladjasmilic
@Mladjasmilic 6 ай бұрын
Fun fact: You can do 10A 7.2kW over 5x1.5mm² cable (total 7.5mm² of copper). Fot the same power, at 30A, you would need at least 3x4mm² (total 12mm²), which is 50% more copper for the same power.
@DarrenBoxhall
@DarrenBoxhall 2 жыл бұрын
Get a deburring tool for those holes. The pen style one
@johnyenagritis8136
@johnyenagritis8136 2 жыл бұрын
a question for Jordan, when u spured from the ring did you use 4mm wire?
@shanginadildo
@shanginadildo 2 жыл бұрын
It looked like he used 2.5mm twin and earth. Which is perfectly fine for one spur.
@rogerbean393
@rogerbean393 2 жыл бұрын
The black paint is probably a rubberised product to prevent ingress of water on the edge of the drive. You low level hole for armoured has just ruined that you should have come up the wall then drill through.
@desmondyoung5963
@desmondyoung5963 2 жыл бұрын
What about safe isolation?
@Lewis_Standing
@Lewis_Standing 2 жыл бұрын
I've got three phase supply coming into the house. Next door is looped off one. I only use one. And my meter is single phase and my consumer unit. I got a charger which is three phase ready (I'd need a new tethered cable) but otherwise if I ever get round to getting a heat pump of hvac etc I could get the DNO to 3 phase my meter ( I think - don't know if next doors lopped supply would be an issue) and then get my 3 phase consumer unit done + charger. Not sure it's worth the bother currently as my kona only accepts 11kw 3 phase. Not sure there's an aftermarket for upgrading that to 22 to be honest.
@davetay44
@davetay44 2 жыл бұрын
What's your issue with Makita Corey ?
@williammartinculleton5875
@williammartinculleton5875 2 жыл бұрын
Spectacular
@AntonyoKnight
@AntonyoKnight 2 жыл бұрын
How can you avoid the 3 phase upgrade in the future? eBoilers to replace old type of gas combi boilers require 3phase supply and I cannot see any other alternative. Gas Combi Boilers are the most common heaters in the uk and no way you can put heat pumps every where.
@johnburns4017
@johnburns4017 2 жыл бұрын
The death of gas in the UK is premature. About 20% of natural gas can be added hydrogen. Block of apartments are difficult, or near impossible, to have heat pumps fitted.
@christopherhulse8385
@christopherhulse8385 11 ай бұрын
That 110v transformer looks like the type that converts not only the voltage but the frequency as well.
@tamtdc
@tamtdc 2 жыл бұрын
We've just had 3phase installed into our garage to charge the car ... (was only £150 difference between that and a single phase to install) Total install cost £2,400 .. Garage was seperate to the house and had no electric so only way was new DNO install.
@stevie1403
@stevie1403 2 жыл бұрын
If your house only has single phase then where did you get the 3 phase supply from? Did it already have 3 phase but you were only using a single phase? I know the LA charge more than 150 quid to add 3 phase as it requires running new cables,digging up the road to the nearest 3 phase supply.
@tamtdc
@tamtdc 2 жыл бұрын
@@stevie1403 there was no electric, it was a dno dig from their main cable. £2,250 for single phase or £2,400 for a 3phase install Ie. Cost of cable difference.. Only. Same dig, same route. Etc.
@granvillebloor6569
@granvillebloor6569 4 ай бұрын
Yes
@stevendavies4572
@stevendavies4572 2 жыл бұрын
I'm installing loads of 3 phase meters for octopus energy at the moment in domestic dwellings.aldo I'm working on new build sites that are fitting 3 phase as standard or instal a split load.its surprising how many jobs I'm getting where dno are upgrading to 3 phase.they are reluctant for obvious reason to run ev chargers ,solar and heat pumps on 100 amp single phase.
@johnalvey5332
@johnalvey5332 2 жыл бұрын
Are you working for a DNO or as an electrician? I have the three 100a fuses but I don’t have the meter tails so would need a new meter. I wasn’t sure if “normal” sparks are allowed to work upstream of the meter.
@johnburns4017
@johnburns4017 2 жыл бұрын
@@johnalvey5332 You would need a three phase meter. The DNO supplies that and the tails from the three fuses to the meter. You supply the three phase Consumer Unit.
@niklaseklund88
@niklaseklund88 10 ай бұрын
Any reason too use single phase? In Sweden all houses have three phase. We use 16A or 25A and in rare circumstances 32A...we have all installed with solar and batteries and EV with 16A.
@dennybaker8755
@dennybaker8755 2 жыл бұрын
Hi I was wondering if these elecric cars can charge them selfs while being used ( driving ) - with a 12v inverter ?
@chrismitchell6478
@chrismitchell6478 2 жыл бұрын
They charge when braking (called regenerative braking). When you slow down the tires spin the motors which charge the batteries. You will use more energy to power the inverter than the power you will get out.
@andybrown3715
@andybrown3715 2 жыл бұрын
Yes they can it works perfectly, for about 30 Seconds!
@endofallhope
@endofallhope 2 жыл бұрын
That large white thing, is a riello UPS. Not just a 110v transformer. Its probably 3ph 400v in 110v out with UPS batteries.
@barrieshepherd7694
@barrieshepherd7694 2 жыл бұрын
and probably does frequency conversion (50 to 60 Hz) as well.
@steve83803
@steve83803 2 жыл бұрын
That job looked like a risk assessment nightmare, confined work area within the garage, slip, trips and falls all over the floor and a skip. Were the cut out fuse seals missing on arrival?
@onewheelnut
@onewheelnut 2 жыл бұрын
great video as usual, not sure if anyone has picked up the fact that car can only charge at 11 kw 3 phase as do tesla, very few take 22 k . lots of cars only take 7.4kw. iv'e talked to people pluged in to 22 kw 3 phase at up to 45p per kw when they can only take 7kw with free to use points close by !
@giddyupgazboy1
@giddyupgazboy1 2 жыл бұрын
Going 3 phase is a bad idea people don't realise
2 жыл бұрын
The Taycan has a 22KW onboard charger option.
@okaro6595
@okaro6595 2 жыл бұрын
3 x 100 A is massive. In Finland houses typically are 3 x 35 A or 3 x 25 A, sometimes 3 x 63 A.
@joepostle3561
@joepostle3561 2 жыл бұрын
In the UK it doesn’t always correlate that just because the labels state the rating of the service head that the actual fuses fitted match that given rating, it can often be downrated depending to what is practically required. It wouldn’t surprise me if this service head could have 80a fuses installed or even 60a depending on the size of the installation when the installation survey was carried out.
@sinder650
@sinder650 2 жыл бұрын
Why not put junction box above the cable duct and go with cable where the ceiling meets the wall and outside for outside outlet much better installation
@Ilikeeminleggings
@Ilikeeminleggings 2 жыл бұрын
The us system is 240V with 120V legs. Those plugs are 120V. A lot of american systems are 120/208Y meaning 3 phase systems have 120V legs
@the_real_hislordship
@the_real_hislordship 2 жыл бұрын
The US is daft. The craziest one is the high leg idea. You get 240v phase to phase on three phase and 120v phase 1 or 3 to neutral. But they also have that high leg nonsense with 208v from phase 2 to neutral. Delta transformer on the secondary with a centre tap between L1 and L3 to get a neutral. Then the new voltages are 277v phase to neutral or 480v phase to phase, but I doubt that is for domestic yet.
@Ilikeeminleggings
@Ilikeeminleggings 2 жыл бұрын
@@the_real_hislordship yes, that is a pain to work with
@alexZWL
@alexZWL 2 жыл бұрын
1 Phase 100amp is already a lot more than the 1phase 35 amp or 3phase 25amp in the Netherlands. Wondering why the big difference. Maybe almost all the houses are gas heated and in the UK electric?
@rossthompson1635
@rossthompson1635 2 жыл бұрын
Probably most UK houses use gas but still quite a lot, especially flats, have electric storage heating and electric water heating. Also electric showers are quite popular (although a bit rubbish for pressure) and they are in the 8 to 10kW range.
@sstorholm
@sstorholm 2 жыл бұрын
Top tip, Hilti will repair almost any tool to as new functionality for a quite modest sum!
@ianstanley5157
@ianstanley5157 2 жыл бұрын
Hilti does not have a life time warranty, they advertise a 20 year warranty. But try get support for a Hilti after 5 years. I sent in some of my Hilti products for a "service" ... there was nothing wrong with the machine, I was told they no longer support the machine :( That clutch is issue seems to be a common issue. I sent in my TE7A for a service, it now leaks oil, it was returned at "no charge", but it is back from their 3 rd attempt to repair it (it was in working order when sent in for the service) and now I am experiencing the same clutch issue with the machine, you have to let go the trigger pull the machine back and then try again, sometimes it will operate but in most cases it just makes that terrible sound.
@ianstanley5157
@ianstanley5157 2 жыл бұрын
By the way I have Hilti products ranging from 5 years old to my TE 55 which is more than 20 years old (still working), I no longer buy Hilti product after my terrible experience with Hilti service SA. Basically been told my company is too small for them to worry about my complaints, they dont return calls nor have a solution to the TE7A issue :( Yet my business which is 31 years and going strong) has supported Hilti Sa longer than any employee at Hilti Sa has worked at the company. I expected to get some money back for the Hilti products I have advertised for sale, not even one enquiry, it seems I am going to have to drop the price and basically dump it. :(
@bencoatesworth7731
@bencoatesworth7731 2 жыл бұрын
Now wondering why someone would need American sockets or power outlets as they call them. Especially in every room. If u live in the uk u probably will have uk socket appliances if you move over yeah but wouldn’t it be cheeper to by some converters for the few American socket things you would bring with you
IS THIS THE SMARTEST EV CHARGER? - INDRA SMART PRO - Electrician Life
36:56
Artisan Electrics
Рет қаралды 120 М.
Мы никогда не были так напуганы!
00:15
Аришнев
Рет қаралды 3,7 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:19
CRAZY GREAPA
Рет қаралды 23 МЛН
I'VE HAD AN EMAIL FROM THE OZEV OFFICE! Electrician Life
24:49
Artisan Electrics
Рет қаралды 92 М.
Single Phase VS 3phase Charging | I Speak ELECTRIC
6:52
Best Electric Vehicle
Рет қаралды 16 М.
"YOU CAN'T MOUNT AN EV CHARGER THERE!" Controversial Install…
26:31
Artisan Electrics
Рет қаралды 78 М.
What is the Difference Between Single Phase and Three Phase???
23:11
Electrician U
Рет қаралды 555 М.
I'VE BEEN AUDITED! AND I REALLY DISAGREE! - Electrician Life
24:38
Artisan Electrics
Рет қаралды 326 М.
How Many Amps Do You Need For Home EV Charging?
26:08
State Of Charge
Рет қаралды 406 М.
Retrofitting 3 phase RCBO's - Schneider Acti9 Vigi Unit's
33:34
Mike Page - Residual Electrical Contractors
Рет қаралды 16 М.
THE ONLY Zappi video YOU need to see!!
13:06
SOTA Electrical
Рет қаралды 12 М.
ПОКУПКА ТЕЛЕФОНА С АВИТО?🤭
1:00
Корнеич
Рет қаралды 3,2 МЛН
Телефон в воде 🤯
0:28
FATA MORGANA
Рет қаралды 1,2 МЛН
Урна с айфонами!
0:30
По ту сторону Гугла
Рет қаралды 7 МЛН
Simple maintenance. #leddisplay #ledscreen #ledwall #ledmodule #ledinstallation
0:19
LED Screen Factory-EagerLED
Рет қаралды 3 МЛН