this might help you, when I was a wildland fire fighter we always rolled up our hose with the connectors outside. When you lay your hose out fold it in half. start rolling it from the middle section. that way you can grab the connectors fling it out and you'll already have the both ends that you need. when it's rolled up you can secure with a makeshift bungee. we use sections of cut up inner tube. go with one inch if you can. it'll be easy easier to handle. you could do use your large hose as a distribution line and run gated Y's off of it. just be careful of how long your lines are. 45psi isn't much but if your well ahead of the fire you can put down a good wet line. cheers
@Ndnlover5 сағат бұрын
Well done.. Thanks for getting me motivated to make sure my home fire equipment is up to par..Job well done..
@anthony9thompson3 жыл бұрын
Great to see you getting prepared. You can prime the suction hose by jiggling the foot valve as fast as you can in the water. Moving it back and forward will push water into the hose on the forward stroke and the foot valve will stop the water coming out on the backward stroke. Works best if you are standing in the water . Also works better if you leave the priming cap off the pump to let the air out at the top. Cheers from Western Australia
@sixoremenos3 жыл бұрын
Good suggestion! I fill the suction hose with water before firing up the pump. Greetings from Greece.
@garymeyer3294 Жыл бұрын
@@sixoremenos That's the best suggestion.
@francescoartusa91683 күн бұрын
Great set up!!! I'm shocked you don't have more views.
@jeffbyrd79765 ай бұрын
Yet another word on a great system. You are not limited to a 24' suction hose, you are limited to 24' of lift. If you have a water source a foot lower, you could have a couple of hundred feet of suction. I am glad you put a recirc line on it, I have seen some that have not. Thanks for the video.
@waxdemo Жыл бұрын
Brilliant. Best how-to on KZbin. I use 'trash' pumps to move water out of the ditches during spring run-off if the culvert gets overwhelmed. The recommendation to use a check valve on the intake and kink the discharge hose then walk the discharge through the hose as it fills is something I never thought of. I would often have problems getting the hose to expand to capacity. The tip I would add is if you are pumping and the temperatures are just above freezing, soak your discharge hoses in hot water first. Great video.
@leebennett36722 жыл бұрын
Excellent good idea .thanks for posting.
@johnkenney72174 жыл бұрын
Thanks for posting. Tiny suggestion - if you can, get rid of that elbow at the outlet. It robs pressure, with no benefit. Cheers
@gtdoering46302 жыл бұрын
Thank you. I was thinking about doing this exact same thing. Saw the price of a fire pump, picked myself up off the floor, and knew there had to be a reasonable option out there in KZbin land and here we are.
@juancarlosmeneses37742 жыл бұрын
Exactly!!
@tjinnes2 жыл бұрын
We are just setting up with the same equipment. Good to see yours in action. Thanks.
@drewrushlow6947 Жыл бұрын
Nice easy set up. I will copy your head export set up. Thanks for the demo!
@BowenOrg2 жыл бұрын
FIRST CLASS ALL THE WAY!!! We're going to put a system together also as soon as we move to the Pacific NW. Suggestion For You & Your Family (since you're also in CA): * I'm going to install a sprinkler system at the top of my home along the "ridge" and then I'll be able to hook up my water pump to not only a hose system like yours but, pump the water to the top of the home (as long as a have access to a large water system like you have) and make the home "damp". * I might even have two systems to make it more redundant and easier on me. * If any fires get close to the home, we'll first turn on the sprinkler system at the top of our home (on a slow mist to moisten everything and conserve water; turn up the volume later if necessary) and then I can take a second water pump and also fight the fire farther out! If ya want to live in the forests and enjoy them, this is the prepping ya need to do and I have no problem with it! Amen Retired, Veteran
@NWMT17 сағат бұрын
As long as you don’t lose power to the sprinkler system…..
@BowenOrg15 сағат бұрын
@@NWMT NO PROBLEM!!! JUST MAKE SURE YOU HAVE 2+ GENERATORS ON-HAND... and fuel and solar panels. * One can be a solar generator... and the other a "combo" gas/propane generator. * We have both. * As a matter of fact, this is exactly what I suggested to everyone about the fires in LA recently... PLUS water tanks and a "fire suit and mask", which can be bought on Amazon and/or Home Depot etc. Amen Retired, Veteran
@patrickelbon87262 жыл бұрын
Great job! You're easy to follow, good presentation. I'm trying to put this together now. Having a little trouble getting the right adapters but I'll manage. Some good comments on here. Thanks again sir, and grateful for all the feedback guys.
@JoeSimple2 жыл бұрын
Hey thank you very much! A good resource for fire hose parts I found is firehosedirect.com not sponsored but has everything. One-stop shop
@REVNUMANEWBERN3 күн бұрын
Jan 2024, just think if all those LA Elites had one of those setups they could of run the hose to their pool & pumped away
@MrNiceGuy5003 күн бұрын
Yup, I’m here outta curiosity as well
@spevakdesigns6 ай бұрын
Fwiw on pump brand at the property I live at we have 2 Honda pumps, a Northstar pump and 2 harbor freight pumps and have had as many or more issues with the Hondas than the cheaper ones. They all get used more or less equally. It feels nice to know there are a few Hondas but as far as what we've seen the reliability is fairly consistent across brands. We also use FH thread instead of camlock and then carry adapters if we need to hook up to a camlock supply. Not sure exactly why, but it's what they had in place when I moved here and the whole setup saw a lot of very successful use in the 2020 lightening fires. Our tanks are located at high points with outlets on the tanks and are all plumbed downhill with underground 3" pvc and steel risers to hook into near the major structures.
@tray8411 Жыл бұрын
Rural N/E Idaho here which means Hi desert... Ive tried a few water/fire fighting systems .. My suggestion is go light as u can to get to hard to reach places.. Transportable fire skids are the best.. Most important,,get AFFF or a lite water solution to mix...Knocks the shit out of deep seeded fires.. Great vid BTW!!
@Stahodad7 ай бұрын
nice rig, well thought out...i like the suitcase idea too.
@bert26a3 жыл бұрын
I'd highly recommend setting money aside for a higher pressure pump. Honda does make some highish pressure pumps that can make at least 70psi. It is a bit of an investment but a standard transfer pump just isn't enough.
@REVNUMANEWBERN3 күн бұрын
Thanks for producing this, some details I wasn't aware of that helps to build such, ONLY thing I would do differently is to mount it, or sit in on a cart with lawnmower type wheels or skids where you can pull it easially with a vehicle or mower AND to convert to Propane & keep it hooked to a propane tank then NO issues with ANY gasoline & safer
@ultimatesoccershow Жыл бұрын
great video, I just bought one and you helped me understand it better, Thank you :)
@SrStew5 ай бұрын
I think if you had a 10 foot rope on the engine side of the suction hose. Throw that end in the pond also pull it out with the rope and it will be full bc of the foot valve and it will be an instant prime if you lift the hose 5 ft away from the pump then water will drain into the pump and out into the flat hose. Worst case you have a rope wrapped around the suction hose 2 ft from the engine. Just an idea. Hey were dod you get the case for the hose?
@mitchmccall76164 жыл бұрын
You might want to look into installing what's known as a "dry hydrant". Also, wildlands fire crews use a 1" hoseline. That and some hand tools will go a long way.
@thenukerunner49063 жыл бұрын
A dry hydrant is basically a normal municipal fire hydrant designed for areas that have freezing temperatures. I’m pretty sure you cannot simply install one a dry hydrant with a pond as the water source. You wouldn’t have any pressure in the hydrant. 1” hose is a great idea especially with using a 1.5” to 1” reducer. You might find an adapter to put at the end of the 1.5” hose then reduce to 1”. This would lengthen the total hose and help reduce friction loss while increasing pressure at the nozzle and more distance coming out of the nozzle.
@ironmatic1 Жыл бұрын
@@thenukerunner4906 A dry hydrant is installed at a pond for pumper suction. You are thinking of a "dry barrel" hydrant. But dry hydrants are intended for fire department use; I don't see what advantage it would have over what he's got unless he's gonna be buying a class A engine as well. Also, you seem to not have a basic understanding of fluid dynamics. How in the world can you possibly think a smaller hose would reduce friction loss and increase pressure?!? The only advantage to reducing the size of hose midway through is reducing the labor required to move it around. Ok well I do know how you could think that, it's a common misconception, but pipes do not behave as nozzles, pressure is pressure regardless of changes in pipe size. Only an actual outlet is a nozzle and produces a stream length. Smaller orifices look like they are making "more pressure" but that's because they are flowing less water, causing less pressure loss in the system. The best thing he could do to deal with the low pressures of that transfer pump would be to use a 2.5" hose with a 15/16" smoothbore nozzle. The undersized nozzle meaning low flow for a 2.5", and the big hose meaning minimum friction loss for such a flow. Smoothbore because it can be effective with as low nozzle pressure as 40 psi.
@SolomonMawunyefia Жыл бұрын
Very good
@Bob-gt1mq4 жыл бұрын
I was just doing research on this and had this pump in my cart on amazon. I think I'm sold, now I just need to find the rest of the parts you have.
@JoeSimple4 жыл бұрын
Hey that's great, happy to help. They should have most of the steel pipe fittings at your local hardware store. and the fire hose fittings are available at amazon or at firehosedirect.com thanks for watching.
@ianfreddy38044 жыл бұрын
Good work sir. I'm over in Sonoma County and I'm building the same setup. Subscribed and thanks for the vid. Stay safe!
@farmerchris98623 жыл бұрын
Nice i am in concow and have 1 heck of a fire setup 3 pumps 2 3000 gallon tanks plus a mobile 330 setup in my truck California mountains is 1 sketchy place to live
@JoeSimple3 жыл бұрын
Yes sir, this time of year I sleep with one eye open.
@medicopie3 жыл бұрын
I would delete that 90 and put in a ball shut off valve. You'll gain a little more psi. Also try and get some 1" hose. Use the 1 1/5 hose to get you out there and the 1" to fight fire. Lighter to use.
@kennethschultz64652 жыл бұрын
Nice job ... Just a head Up!! Most if not All fier stations Dry out ther HOSES beford Rolin Them Up!! They rot if stored wet!!
@ericpeck31802 жыл бұрын
Although historically fire hoses were spun with cotton, modern firehouse are synthetic and water doesn't affect them other than causing foul smelling water. But it is a good idea to drain them, much easier to stretch out the next time they're needed. The sun's UV destroys hoses...and extension cords.
@kennethschultz64652 жыл бұрын
@@ericpeck3180 All Danish godt stations i know of Dry out ther A B C hoses after end use Becaus of the (rubber insider the cotten Shield rot ower time when left wet MAYBE they now in 2022 hawe new Rubber silicone insider not rotting AWAY As far as I know they still dry out ther hoses)
@kennethschultz64652 жыл бұрын
And ofcorse in a city with call out EVERY DAY IT is not nessesery But when you like in Denmark Hawe MAYBE 2 calls or More terning then aculey Fiers wełl THING seems to get rotten Way faster if not dryed Up..
@MR500BULLIT3 жыл бұрын
Great informative vid. Looking to buy the Honda WT30 , for a rainy day. Thank you!
@richardroberts43553 жыл бұрын
Nice setup. Honda is the only way to go in my opinion. Put that very pump thru a lot working at a marina. Reliable.
@angelobarros77444 жыл бұрын
Great stuff love your videos
@JoeSimple4 жыл бұрын
Much appreciated
@ericpeck31802 жыл бұрын
It is much quicker to stretch a hose line if you fold instead of roll it up. Another downside to rolling is the hose close to the fitting on the inside end can see premature wear because of the kink. Small engines stay reliable when the gas in them is the best it can be. For something as dependable as a fire pump, ethanol free gas would be smart of course running the pump every once in a while. (Side note for small engines) Although I don't think Honda uses vinyl fuel line but ethanol in fuels actually will eat vinyl over time. The more expensive black rubber gas line is where it's at.
@anthony9thompson3 жыл бұрын
I’m sure you know this but the 24 foot suction limit refers to vertical distance not horizontal. So in theory your suction pipe could be much longer as long as the ground relatively flat. 🙂
@sassriverrat3 жыл бұрын
hahah I was about to comment that.
@enjay89503 жыл бұрын
This applies to head limit too
@BowenOrg2 жыл бұрын
EXCELLENT!!! DON'T forget your mask aka respirators so you don't get stuck in a bad situation if the wind changes on ya!! Amen Retired, Veteran
@realestate54612 жыл бұрын
where do I buy this set up? We have no fire hydrant at our house. Thank you
@likeaboss860 Жыл бұрын
A good way to prime these is turn of the kill switch , fill the pump with water and then pull on the recoil a few times and fill it again.
@ih8people679 Жыл бұрын
I have the wt40x 11hp. Its 4" with over 325' of hose, i wonder if its too much.. obviously its heavy-duty and the pvc hoses are heavy when full of water. Probably not great for putting out fires and only bringing water from the lake up to flood the property
@seymourpro6097 Жыл бұрын
Canvas fire hose needs to be dried thoroughly after use, this is why fire stations have(had) towers! A damp hose rots and splits under pressure.
@beckyumphrey26265 күн бұрын
The lift and head is vertical capability not horizontal capabilities.
@itptires3 жыл бұрын
You seem to misunderstand the head concept. Head is height- it doesn't matter how long your suction or discharge hose is in regards to the Head. Yes longer hoses will move less water / lower discharge pressure but you can theoretically have hoses much longer than what you currently have. I design basic fire systems in regards to pressure losses from fitting and pipe length etc. And as another person mentioned if possible get rid of the 2" 90
@kennethschultz6465 Жыл бұрын
THE FIRST HOSE .. YOU LOOSE WAY TOO MUTCH PRESIUR AND WATER ... IN TOO MUTCH 1.5" UPGRADE THE CARRIERHOSE TO 2.5" AND GO FROM 2.5 TO T 1WATER HOSE AND THE 1.5" HOSE TO KEEP PRESIUR UP FOR AS LONG A STRETCH AS POSSIBEL ... BOTTELNECK
@THEWRENCH3434 ай бұрын
You might not want to set your pump in dry, dead grass. You could be starting your own fire!!!! 🤣🤣🤣
@TheUGFUGF3 жыл бұрын
No expert here however common sense would dictate that if the hose is able to be kinked so easily (like yours) you do not have enough pressure. Remove the elbow as well. Contact local fire and verify what type of hose/fittings they use to copy
@kennethschultz64652 жыл бұрын
Common sence also dictates That a thin hose kinks EASY At same presiur as C or B Hose does!! The NOSSEL presiur Was atleast 20Meter /2+Bar / 30psi
@101boss52 жыл бұрын
How much horse power doesn't that have
@christophermozeleski71494 жыл бұрын
Get yourself a woodland nozzle. They need less pressure to work.
@chrismozeleski54694 жыл бұрын
Wildland nozzle
@ironmatic1 Жыл бұрын
Wow thanks for being one of the few people on the internet using an actual structural firefighting nozzle and not one of those ancient occupant hose nozzles that are insanely flow restricting. But maybe a gauge on the pump discharge? Is the pump able to get adequate pressure to the nozzle? Is it a 75 or 100 psi nozzle? Are you flowing at least 150 gpm? Edit: Just read another comment saying this is a transfer pump and not a high pressure pump. I would suggest if you are going to be using such low pressures (I can tell by the kinking in the line just from you holding it), that you try a 2.5" hose with a 15/16" nozzle tip. This should be able to produce adequate fire flow at nozzle pressures as low as 40 psi with minimal friction loss.
@shanestamball18864 жыл бұрын
if thats full power, better ditch it and grab a harbor freight 2inch trash pump
@albundy36962 күн бұрын
those dried brushes need to trim down , really fire hazard .
@elcampodominicano12543 жыл бұрын
Too much talking and don't star
@firedefense Жыл бұрын
Great Video! Let’s work together to help others…..