These guys are awesome, I love their personality and skill level.
@hpa1016 ай бұрын
Sorry it took so long for us to reply but thanks for the support mate!
@PreludeDude Жыл бұрын
I work on MRI machines which use a lot of RF cables to transmit power and signals. There was one instance where a simple pressure switch with unshielded 2 wire cable was causing interference with the RF cables enough that it would inhibit scanning. After changing that one cable/harness for a shielded version the issue resolved. My cable had a ring terminal for the shield drain on one end, and then the metal DB9 connector housing on the other end provided ground there.
@Wetfingers Жыл бұрын
In military aircraft wiring, there are various methods. The two most common are actually grounding it on both ends of the harness run. Or solder sleeve it to wire/pin that later goes to ground.
@Nikoxion Жыл бұрын
Doesn't grounding the cable shield on both ends negate the purpose? Or did I misunderstand?
@vozhdmeister5256 Жыл бұрын
@@Nikoxion Right, shields ground at one end only
@LTVoyager Жыл бұрын
@@vozhdmeister5256No, shields should be attached at both ends pretty much always. There are very few specialized exceptions. I would post a link, but often links keep KZbin comments from getting posted. I will try to post in a second comment in case the url kills the comment. Both the military and FAA get this right, but almost everyone else gets it wrong.
@alexispavlov517011 ай бұрын
Grounding both sides does not make sense. Your ground isn't just a ground, it's a conductor, it conducts the main power current. When you connect both sides of a shield to the ground you split the ground current with a part of current now flowing through your shield. As any conductor the shield has a resistance, so the current will induce a voltage drop, and your shield will start being an emitter of this ground signal. So you'll get an excellent emitter very close and all along the shielded cables. That's why the shield must be grounded at one end and at the reception end. It's possible that in military domain they create separated main power and low power grounds, in which case grounding both sides to the low power ground is safe.
@bigbothoee8617 Жыл бұрын
Lolol that brade was putting up a fight 😂
@user-dy3pq6lx5m3 ай бұрын
Thank you. As an amateur trying to learn the tricks of the trade your videos have been invaluable. Have you had any issues with the wire insulator melting and contaminating the solder?
@hpa1016 ай бұрын
What's your 'current' wiring project? 🦸♂ Building a fast car? Get $400 OFF the all inclusive VIP online course package deal: hpcdmy.co/vipy104 ⚡ 50% off your first online wiring course! Get the knowledge and confidence you want. Enrol today: hpcdmy.co/offery104 TIME STAMPS: 0:00 - Mission Critical Wiring 0:28 - Measuring & Stripping 2:01 - Boot Template 2:23 - Exposing Braid 3:33 - Cutting Braid 5:00 - Solder Sleeve Options 5:52 - Ref & Sync Marking 6:20 - Solder Sleeve 7:02 - Splicing 11:02 - Heat Shrink 11:25 - Finished Splice 12:18 - 1 Of Over 40 Modules
@0xgggz Жыл бұрын
How far should the shielding go on the sensor end?
@BraydenSummerlin-f7v10 ай бұрын
Where do we find those clamps?
@donnymcballer4659 Жыл бұрын
Great information. Had to turn on CC, though, cause I have no idea what language he’s speaking. Its very bizarre, it’s like english, but with a bunch of funny sounding gibberish nonsense words thrown into every sentence.
@hpa101 Жыл бұрын
That's exactly what it is 😎 Glad the captions helped, we refrain from throwing gibberish in those too - Taz.