Been waiting on this 1, as always quality video! Great content, have heard these Boilers are real good. Thanks for sharing br 👌✅💯
@PlumbingDoctors3 жыл бұрын
Yes good boilers I fit these every week 👍🏻
@andyr2011ar3 жыл бұрын
Just found you. Enjoyed your video. Cracking job. Following mate.
@ondarae6423 жыл бұрын
Great video, helped me to find the water inlet to re-pressure the boiler, as I over vented the radiators, and the boiler went off just at the weekend when I couldn't get any help. So massive thanks.
@PlumbingDoctors3 жыл бұрын
No problem!! - I also have made a shorter video just for increasing pressure if you search other vids
@ondarae6423 жыл бұрын
@@PlumbingDoctors Will do, and thanks again.
@saidahmed410 Жыл бұрын
Thanks brother. I like your all video. Very helpful video for me as a new Gas engineer. 👏👍😊
@imaginehomes38713 жыл бұрын
Thanks for the installation vid. I got a PCB for a Vaillant Ecotec 831 for £75 and fan for £110 all fitted for £80 and it's been running for years since. Didn't need a new boiler. I do always have Main Eco Compact Combi or system as replacments.
@PlumbingDoctors3 жыл бұрын
Landlard had enough and wanted new boiler so i replaced ;) - i love repairing tho
@rajeshbangera61493 жыл бұрын
Thanks for your detailed video. Its definitely helps new comers. Cheers
@PlumbingDoctors3 жыл бұрын
No problem 👍🏼
@nkhalid6773 жыл бұрын
Great video as I’m new gas engineer very helpful
@sodig8763 жыл бұрын
Good video 👍 proper real world work. Not fitted a Baxi combi since the Netatec! days Will definitely consider it now not many boilers come with brass components inside nowadays.👍
@PlumbingDoctors3 жыл бұрын
Thanks mate.. Ive come across a few Netatecs they have the gas valve which is adjustable from the display.. I fit these everyweek and not had any major issues and the build quailty it great 👍 well worth the money 😎
@theetheeyog98783 жыл бұрын
Good work pal there are other chanel they don't wont to show as much detail as you do when it comes to fixing boilers
@PlumbingDoctors3 жыл бұрын
Thanks buddy! Im just trying to help share some knowledge
@lalaji923 жыл бұрын
Best video ever so clear welldone bro keep it up ma sha Allah
@DaBriars3 жыл бұрын
Love your channel Best on KZbin by far Thanks for sharing
@PlumbingDoctors3 жыл бұрын
Thanks 😊
@neilbirkett8353 жыл бұрын
Love the videos, keep em coming.
@PlumbingDoctors3 жыл бұрын
Every sunday at 4pm 👍🏻👍🏻👍🏻
@darrenowen3338 Жыл бұрын
Excellent, informative video. Thank you.
@PlumbingDoctors Жыл бұрын
Glad it was helpful!
@laurentiudaniellobont6253 жыл бұрын
Very nice and good video!!!! All the best !!!!
@simonhelps3023 жыл бұрын
When cutting flue for example. One mark for measurement....then wrap a piece of paper snug and inline( quick to do) then run marker around paper 100% square everytime.
@PlumbingDoctors3 жыл бұрын
Nice 👌
@rayc15033 жыл бұрын
Btw the flue's supposed to be dead on straight out the wall. The flume exhaust already has condensate fallback built in. At baxi training they said with the main eco compact the back top casing can be trimmed off to accept vertical pipework. It's why they come with the vertical pipe bracket in the box. Simple boilers to install 👍🏼
@PlumbingDoctors3 жыл бұрын
I did not know you could put the flues on straight 🤔 Ive always put them on an angle.. & Yep ive heard about cutting the back casing so you can pipe behind 👍🏻
@rayc15033 жыл бұрын
@@PlumbingDoctors bro look at the flue itself the exhaust plume isn't death on centre. It's towards the top of the flue. This is to account for condensate fallback. Great upload 👍🏼
@parvizahmadi2983 жыл бұрын
Thank you, very informative. helped me a lot.
@mohammedrafiq30523 жыл бұрын
Very good video just to point out if you want to run pipe work from behind boiler I think they do a bracket that will allow you to do that
@SilatFanTV2 жыл бұрын
Thanks for this. Quick question. Ive got low water pressure and need to turn both blue knobs open. My second blue knob (on the right) has been installed in such a way that when I try turn it fully open its stopped by the bigger black knob behind it. Im assuming incorrect installation. Am I safe to turn the black knob to allow me to turn the blue knob? What can I do? Thanks
@PlumbingDoctors Жыл бұрын
twist the blue knob around or try closing the black knob but may not let water into the system
@javed30063 жыл бұрын
Very helpful video for new student thank you
@ShadowRealmBrosikles3 жыл бұрын
Very helpful video Waseem bahi I’m new in this game and learning a lot from your videos
@imaginehomes38713 жыл бұрын
You can pipe upwards with the stand off bracket. Also need to pipe 28mm off the back of the boiler for anything above about 35000 btu or friction losses cause slower heating, Can come out straight into 22mm and up to 28mm with a 28mm elbow. Just run the 28mm until the rest of the system is less than 35,000 btu then drop to 22mm. The stand off bracket (if you need it) is for 22mm or 28mm pipes. On the Baxi 600/800 you need the stand off for 28mm. Most people think it's 22mm only just because that's on the back of the boiler but that's wrong. The 22mm pipe causes 99% of the restriction so 28mm relieves this and the flow rates and heat up times are massively better. Below 35000 btu it's okay for 22mm. I also use full bore rad valves (14mm internal bore that open up to 14mm)..
@PlumbingDoctors3 жыл бұрын
Good info about the pipe sizing but very rarely do i need to use anything larger than 22mm as i work on Small - Mid size houses
@ArifPolicewala8 ай бұрын
Good job Waseem. Made the look easy.❤
@PlumbingDoctors7 ай бұрын
Thank you 😊
@dinosauraccounts14112 жыл бұрын
Excellent video. Please make a video on a full service for these eco compacts
@PlumbingDoctors Жыл бұрын
👍
@DannysGandB3 жыл бұрын
On the back of the pcb cover it tells you how long the electrical cable connections need to be cut to
@PlumbingDoctors3 жыл бұрын
Yep your right but i never use it
@MartyJones Жыл бұрын
Hey mate great video! I have this boiler and I’m certain the fuse has gone on the circuit (already replaced 3amp electrical) can a standard 2amp 2mm fast blow be used? Or is it a specific size for this boiler?
@PlumbingDoctors Жыл бұрын
Yes change the fast blow it may be 1amp or higher
@MultiOutdoorman Жыл бұрын
#3. Let's not forget to electrically isolate the mains supply. Fuse in pocket. And fill the kettle for a brew before you begin !
@PlumbingDoctors Жыл бұрын
Come on 👍🏽
@hamzaparvais39482 жыл бұрын
Thank you extremely knowledgeable Great
@PlumbingDoctors2 жыл бұрын
Your welcome
@mchagh95942 жыл бұрын
Great video . I have the same one . But i have no idea how to switch the boiler off . I only put in on min . But it seems to me that the boiler is always on
@PlumbingDoctors2 жыл бұрын
You can only switch these off via the fuse spur but they use no gas if there is no demand for heating or hot water so no need really to switch off
@mchagh95942 жыл бұрын
@@PlumbingDoctors thank you so much for getting back to me . I was concerned as the fan seems to be working all day and night and i was thinking the gas is been consumed.
@snagright13003 жыл бұрын
Clean work bro even in that tight space
@PlumbingDoctors3 жыл бұрын
Thanks bro 😎
@snagright13003 жыл бұрын
Plumbing Doctors will you be releasing magnacleanse video bro? Couldnt find it on your page 😅
@PlumbingDoctors3 жыл бұрын
Check the baxi vid with magnacleanse 🙄
@snagright13003 жыл бұрын
Plumbing Doctors ahh sick i found it 😅 thanks bro keep up the good work helps us learn new methods of worker smarter!
@PlumbingDoctors3 жыл бұрын
👍🏻👍🏻 more vids to come bro😎
@jazzifte Жыл бұрын
Broski what a wicked video. Ive jist had one installed and the heater symbol flashes and the pump runs constantly with no heating or water demad and advise bro
@Telstar_110 ай бұрын
Does this boiler have a pre-heat for hot water setting that keeps the boiler on intermittently? If so, where is this function turned on/off? Thanks.
@PlumbingDoctors9 ай бұрын
Nope it doesn’t
@bobbys92522 жыл бұрын
thanks for the video ,I've got one question which i saw 2 other people also ask this question but no replay given exactly about this .The question is 2 days ago someone install this boiler for me but it is always humming during day and night even thought not using hot water or central heating but still humming all the time, so could you please tell me and other readers what is that humming sound coming out of boiler? Is it normal or something need to done? Thanks
@PlumbingDoctors2 жыл бұрын
No idea best to call installer back out or call Baxi to come and take a look
@ram64man10 ай бұрын
I miss your videos sir, please bring them back soon
@PlumbingDoctors9 ай бұрын
👍🏽 thanks bro
@londonertiger77252 жыл бұрын
Good vid brother, I have this boiler for 2 years. Its been generally ok, had 1 warranty claim, slight leak above diverter valve. Some critcism, the display needs a LED light when in operation, more intuitive info on display would have been ideal (see vokera evolve ), limited controls as leave all to thermostat. Could have done with pre heat like older models, the left hand side blue lever is too stiff.
@PlumbingDoctors2 жыл бұрын
The led is bang on - shows you what you need to know. That left lever is always stiff not sure why
@ivecamperbuild_thomas40842 жыл бұрын
Can I ask is there a glass fuse in the connector block to protect the MCB many thanks
@PlumbingDoctors2 жыл бұрын
I believe so
@Juandan593 жыл бұрын
Great vid, does the outside flue have to angle down? I get water dripping from the bottom of the boiler when it rains sometimes only when wind blows a certain way.
@PlumbingDoctors2 жыл бұрын
Slight fall back to boiler yes
@murtazahussain40542 жыл бұрын
Thanks for the video just a quick question 🙋♂️. When it came to the wiring you skipped over it real quick and didn’t show the wiring on the thermostat. If I am correct the live and neutral connect via the boiler along with the switched live and common back to the thermostat.
@PlumbingDoctors Жыл бұрын
yes thats i how do it but can be done different
@MohammedAli-lb3en3 жыл бұрын
Great video 👍
@peterfido87352 жыл бұрын
Great informative video 👌 I'm looking for a 30kw combi boiler at the moment! My question is , what make and model combi would you recommend in the purchase price range of up to around £850 ?
@PlumbingDoctors2 жыл бұрын
This boiler in 30KW
@soyebmankda83873 жыл бұрын
Great video needed a magna clean and shock arrestor always test the systems water before install may need flushing or cleanse
@PlumbingDoctors3 жыл бұрын
We did flush the system and landlord did not want to pay for the shock arrestor so 🤷♂️
@emekaABC3 жыл бұрын
Mr Gods sent !! well done ....HW
@mistaceali11773 жыл бұрын
Excellent video bro 👍🏽
@PlumbingDoctors3 жыл бұрын
Thanks bro
@Fizzy011663 жыл бұрын
Amazing content. Really helping me out since being qualified. Can you do an in depth vid of power flushing. And keep up with the normal content. Jzk
@riazulhaq6211 Жыл бұрын
Excellent informative video
@PlumbingDoctors Жыл бұрын
Glad it was helpful!
@222rimantas11 ай бұрын
I did twice as you instructed, but the boiler did not activate for me. Cold water is running and the radiator is cold.
@Razz603 жыл бұрын
Brilliant video bro thanks
@faridratni67993 жыл бұрын
ما شاء الله Brother excellent video one thing I don't understand why did you put drain off in flow and return because I put 22mm cap for easy powerflash in future!!! What do you think
@PlumbingDoctors3 жыл бұрын
I put the drain off on both flow and returns to make future maintenance easier & aslo makes draining up stairs circuit easier 😉 If the system was to be powerflushed in the future they can do it from the magnetic filter elbows 👍🏻
@earthling20222 жыл бұрын
At 18:37 , the double spin, I spun the tap one and got an error code ( which was better than nothing at that stage - as the boiler wouldn’t function!) Double spun the radiator one and it all started working ! thanks for your video 👍🏽
@PlumbingDoctors2 жыл бұрын
😉
@kuldhup4746 Жыл бұрын
At 18:37 , the double spin, I spun the tap one and got an error code ( which was better than nothing at that stage - as the boiler wouldn’t function!)
@kuldhup4746 Жыл бұрын
yes
@lunedog794 Жыл бұрын
You know the heating mode symbol (radiator)? Is it normal for it to be flashing?
@PlumbingDoctors Жыл бұрын
When the heating is on yes
@happyslapper073 жыл бұрын
Can't wait for this video also can you do a video on a condensate soakaway I've look on KZbin over the Internet there is so video showing anyone fitting one thanks
@PlumbingDoctors3 жыл бұрын
Soak aways are very easy just follow instructions on the bag and make sure you use limestones
@happyslapper073 жыл бұрын
@@PlumbingDoctors hi thanks for replying yeah I fitted one this week followed the instructions just wanted to make sure it was right as I've never seen anyone fitting one I did use limestone around it so am sure it will be ok. Any chance you could do video on soldering I can solder the joint I tend to over solder is the vertical joints top part of fitting is alright just the underneath one I tend to over solder as am worried there is not enough sucked up into fitting.
@PlumbingDoctors3 жыл бұрын
Yes i will make one in the future 👍🏻 with soldering there is no shortcut to experience, the more you do the better you will get 😉
@2009bager Жыл бұрын
Does the condensing pipe outside required do isolation?
@PlumbingDoctors Жыл бұрын
Nope
@Hussain-ch3pr2 жыл бұрын
Salaam bro, when I turn the rad temp down, the lowest it goes to is 25 degrees and not zero. Can this be rectified?
@PlumbingDoctors Жыл бұрын
Walaykum aslaam wa rahmaulahi wa barakathu - nah you cant just turn off from room stat
@1Monaghan3 жыл бұрын
Love these boiler install videos. Great work. How does the inner flue seal when being pushed into the elbow? Do you Leave it a little bit longer than the outer flue and it pushes inside the elbow?
@PlumbingDoctors3 жыл бұрын
No with these boilers you cut the inner flue the same size as outer flue 👍🏻
@PlumbingDoctors3 жыл бұрын
The flue elbow has two rubber seals: large seal for outer flue and small one for inner flue ✌🏼
@rayc15033 жыл бұрын
No white should of the flue Should be visible on the outside. 👊🏼
@krystopcosek76410 ай бұрын
How about the main electricity wire less than 25mm from gas pipe? ( ID?)
@bahiaharjinder3 жыл бұрын
Nice demo thanks Job done 👍
@PlumbingDoctors3 жыл бұрын
Thanks
@juberkjahmed25082 жыл бұрын
Hi, do you have to put 300ml water inside the flue
@PlumbingDoctors Жыл бұрын
I believe baxi want you to do it yes
@jsmid3 жыл бұрын
Good video keep them coming
@Shah-uw7pc3 жыл бұрын
How did you manage to set the minimum heating setting to '00'. My own only allows it to go down to '25'. Is there a setting on the PCB?
@PlumbingDoctors3 жыл бұрын
Nope just turn the dial to min
@ashokrawal38203 жыл бұрын
Great. Video, thanks
@happyslapper073 жыл бұрын
Great video thanks for showing install could you show a little more detail when you measure the flue I know its from the outside wall then is it to the front edge of the flue the black turret bit. Also there is a regulation regarding the condensate discharge to outside needs to be lagged using waterproof lagging there is a kit you can buy called condensate pro.
@PlumbingDoctors3 жыл бұрын
Yep im aware of that thanks 👍🏻
@happyslapper073 жыл бұрын
@@PlumbingDoctors also you need an air break in the condensate pipe as its going into a stack pipe to prevent back feed into boiler. The fall is not correct as there is a flat spot where water could freeze.
@PlumbingDoctors3 жыл бұрын
I'll have a look into the air break but its never froze even with the old boiler so 🤷
@joncoke82083 жыл бұрын
@@happyslapper07 you only need an air break if going into a down pipe 🤗
@happyslapper073 жыл бұрын
@@joncoke8208 good practice to put air break in as I've been to boiler breakdown where stack pipe blocked and backed into boiler full of piss and shit so I would put air break on stack pipe.
@StillLookingForHelp3 жыл бұрын
Hi brother. I have this boiler fitted new but it feels like it’s always on. It’s always humming and radiators get warm when someone is having a bath. I don’t have a themostat on it. Is there a way to turn it off
@PlumbingDoctors3 жыл бұрын
Remove the yellow link
@StillLookingForHelp3 жыл бұрын
@@PlumbingDoctors thanks for the reply. I’m really sorry but what’s the yellow link
@Rycka9 Жыл бұрын
Is it ok to keep the same flue from Worcester boiler for main eco?
@cathyoshea38445 ай бұрын
Excellent video lads, well done. What about the inhibitor? I'm sure you added to the system.
@PlumbingDoctors5 ай бұрын
Absolutely
@grahamwilson27482 жыл бұрын
Great video very informative and a great boiler I notice in the installation manual it mentions adding 300ml of water via the flue outlet is this something you do?
@PlumbingDoctors Жыл бұрын
Sometimes when i remember lol
@mightyswift2 жыл бұрын
I've just had one of these boilers installed for £1,800. Would you say that's a fair price??? How much would a baxi 800 cost??? Cheers 👍
@PlumbingDoctors2 жыл бұрын
Everyone has their own prices and it depends on loads of different factors... As long as your happy with the job that's what really matters
@1981shafi2 жыл бұрын
Hi. Great video. Can I ask what merchant you use? All the ones near me have sold out.
@PlumbingDoctors Жыл бұрын
Cov plumbing
@alistonpereira34933 жыл бұрын
What's the best setting for hot water and radiatiors.. thanks
@PlumbingDoctors3 жыл бұрын
Depends on size of rads but i usually set: HW: 50 CH: 65
@iftakharmohammed19422 жыл бұрын
Very helpful
@ismailbhayat68012 жыл бұрын
Well explanation
@PlumbingDoctors2 жыл бұрын
👍🏼
@reliabill873 жыл бұрын
Brilliant install but does the flue not need to be screwed in from both sides of the flue elbow?
@PlumbingDoctors3 жыл бұрын
👍🏻 Yes it does but i did not record it..
@reliabill873 жыл бұрын
Ah that's awesome, usually they are quite awkward, would of been good to see if you had any techniques.
@PlumbingDoctors3 жыл бұрын
Check the baxi 800 vid as i show it in that video.. Use the right screw head and also its easier if you drill a pilot hole with a metal bit first 👍🏻
@koskesh3602 жыл бұрын
Hi mate, I recently just had this boiler fitted. it is working fine, but how does the warranty work? is it with my local plumber who installed it, or the the company Main ? thanks.
@PlumbingDoctors2 жыл бұрын
The warranty is with Baxi. Any issues give Baxi a call directly but make sure you have all paperwork and it gets serviced every year
@simoncarpenter91193 жыл бұрын
Top video cheers.
@macpatel78103 жыл бұрын
Hi. Great video again. Looks like a nice job.. Just a small question.. did you power flush the system? Is it necessary on a new boiler install or is there no need ? Is it required for the manufacturers warranty? Thanks in advance.
@PlumbingDoctors3 жыл бұрын
Yep we flush all systems when fitting a new boiler and yes it's required by all manufacturers (they want system water to be clean) 👍🏻
@macpatel78103 жыл бұрын
@@PlumbingDoctors ok great.. just wondered as I did not notice you doing it on this one. I must have missed you mentioning it if you did. Do you use a magna cleanse through the filter connections with boiler running or a regular power flush machine? Cheers
@PlumbingDoctors3 жыл бұрын
Nope i did not mention it in the video either and it depends on how dirty the system is but usually i use the Magnacleanse Flush 👍🏻unless system is very old and dirty.
@macpatel78103 жыл бұрын
@@PlumbingDoctors makes good sense. Thanks
@jazdhaliwal22133 жыл бұрын
Really good video
@PlumbingDoctors3 жыл бұрын
👍🏻👍🏻
@ivecamperbuild_thomas40842 жыл бұрын
What could be the problem if you turn it on at the fuse spair and it doesn’t light up
@boigoe8 ай бұрын
Ho brother at the beginning of the video...the installation pipe, nuts and filling loop kit can all that be bought separately as a kit
@PlumbingDoctors8 ай бұрын
Yes it can
@boigoe8 ай бұрын
@@PlumbingDoctors wher from and how much roughly
@WeShowMemes5374 ай бұрын
Have u put any screw to the flue elbow?
@PlumbingDoctors3 ай бұрын
Yea
@davidhenderson98933 жыл бұрын
Great video, Is the flue connection on top of the boiler and the flue connection itself out the wall just a push-fit fitting(s)? No sealant needed?
@PlumbingDoctors3 жыл бұрын
Yep just push fit just lube the seals up before pushing it together
@davidhenderson98933 жыл бұрын
@@PlumbingDoctors Can you do a video on the procedure you go through when isolating the gas to a property? Ie. As in more than just turning the lever valve off, or do you just leave it at that? Love your videos 👍
@PlumbingDoctors3 жыл бұрын
You should carry out a tightness test before turning the gas off
@davidhenderson98933 жыл бұрын
@@PlumbingDoctors If you could do a video of that, that would be great, Ps. Qualified plumber, not just some bloke chancing my arm ha 👍
@PlumbingDoctors3 жыл бұрын
Are you Gas Safe?
@abchannel37373 жыл бұрын
Excellent
@kamranraja91973 жыл бұрын
Good video please share link in when installing a vaillant boiler
@PlumbingDoctors3 жыл бұрын
Subscribe to channel and you will see it when it gets dropped
@paulstevens53293 жыл бұрын
I find the rear nut on the gas connection always slightly leaks for some reason .
@PlumbingDoctors3 жыл бұрын
Ive never had that issue but a bit of jointing compound should sort that ;)
@ivecamperbuild_thomas40842 жыл бұрын
What if it dose not light up when your turn it on
@mihaelaghita16123 жыл бұрын
Hi if it's showing E110 what should I do?
@222rimantas Жыл бұрын
How to connect the Eco Compact boiler when the refill is over ?
@PlumbingDoctors Жыл бұрын
Im not sure what you mean sorry brother
@222rimantas Жыл бұрын
@@PlumbingDoctors I top up everything, everything is fine, but the boiler does not turn on, what should I press? What is the buttons sequence?
@waseemkhaliq9333 жыл бұрын
Brother what fault codes did it have .also what do you do with this when you take it out I could do with this for spares for my vaillant 😀
@PlumbingDoctors3 жыл бұрын
I can't remember as the job was done in December🙄 I strip all parts from my old boilers and scrap everything.. i don't ever use 2nd hand parts when repairing boilers 👍🏻 but i do keep some screws and other bits for stock
@barrydoherty6363 жыл бұрын
Well done.
@jasonoliver95493 жыл бұрын
Basically great video Basically nice job guys Basically
@PlumbingDoctors3 жыл бұрын
Basically basically comment
@UmarKhan-ww8jl3 жыл бұрын
Brother I need to install a new boiler in London please give me your details ?
@PlumbingDoctors3 жыл бұрын
I don't travel that far sorry bro
@ashrafpatel31912 жыл бұрын
My new main boiler 133 error how to solve
@Shah-uw7pc3 жыл бұрын
Was that a volt free connection for the thermostat?
@PlumbingDoctors3 жыл бұрын
At the boiler its 230V
@stevefletcher8157 Жыл бұрын
I'm having one of these installed for £1.800. Straight swap for ideal logic . Is £1800 a reasonable price?
@PlumbingDoctors Жыл бұрын
yes
@davebayliss31423 жыл бұрын
Brill vlog 👏👏
@billyoneputt18393 жыл бұрын
What was wrong with the vaillant? All parts still available
@PlumbingDoctors3 жыл бұрын
Customer did not want to repair
@leetaaprayzaanio4751 Жыл бұрын
How come you've fit the boiler onto a combustible wooden surface? Isn't that against Gas Safe regulations?
@PlumbingDoctors Жыл бұрын
Nope it's fine
@bobgibb27812 жыл бұрын
I had one installed today . Heating working fine , hot water fine . Switched it off at the socket . Switched it back on and it's completely dead . Nothing on the display .I've held the reset button down for various lengths of time , nothing . What have I done wrong ?
@PlumbingDoctors2 жыл бұрын
Check to see if you have power at board or at socket
@yasreh58458 ай бұрын
Aslamoalaikum.hope you and your family are well ameen. Iv been watching your old videos been waiting for new context.above all hope everything is ok with you.
@PlumbingDoctors8 ай бұрын
Wa alaikum as-salam - just busy at the moment
@yasreh58458 ай бұрын
@@PlumbingDoctors jazakAllah for reply.im happy you are ok. Im on training few more jobs left for my portfolio your videos help me alot.👍
@willpierce21713 жыл бұрын
Can you pipe up the back on these?
@PlumbingDoctors3 жыл бұрын
If you remove the plate at the back you can but i went on a Baxi Training course last week and asked this question to the tutor and said its not allowed and can invalidate warranty But before that my local rep told me it was fine to remove the plate... 😕
@Shah-uw7pc3 жыл бұрын
Good video
@roderickthomas1162 жыл бұрын
well presented 👍🏾
@PlumbingDoctors2 жыл бұрын
👍🏼
@Dabayare19 күн бұрын
The Main Compact 30K in my area is now £700 but the gas engineer quoted me £2600 for installation. Is that fair?
@PlumbingDoctors18 күн бұрын
Depends on the job we usually charge around £1700 for a standard main combi swap
@Dabayare18 күн бұрын
@@PlumbingDoctors I had a similar boiler with the same connections and outlets. I found one who quoted me £1800 for a Baxi 800. So my gut feelings worked.