Thank you for sharing your tips and tricks Ralph! Stoked to have stumbled onto your videos. My METUS sales are beginning to increase and these are extremely helpful.
@tristenludewick30308 жыл бұрын
just put an MXZ-3C30NAHZ in my house. I'm a Diamond Dealer in the Wichita Area. Great Mitsubishi videos, you have a similar attention to detail as my company does. Keep up the good work.
@richardfossani64218 жыл бұрын
Inspector by me also gave me a problem with that wire. Doesn't want it running in attics or in sealtight. But he turned me onto using 14-3 uf outdoor romex. Its 10 times cheaper and can be run anywhere and in sealtight. $83 for a 250ft roll last forever compared to about $50 for 50 ft of that mini split wire. Nice job Ralph
@incognitotorpedo426 жыл бұрын
Nice tip on the 14-3 uf. Honestly, I don't see a problem with the mini split wire in sealtite. It's not lamp cord.
@mdovideo14145 жыл бұрын
Do you always braze mini split line sets. I always thought that the line sets on a mini splits were charged with freon from the factory.
@phillipjoy81918 жыл бұрын
Nice little trick with the swaging tool.Good video
@brianmahoney1547 жыл бұрын
Nice job! Only thing I would do differently is that I would start charging with the micron gauge in place. When it read over atmospheric pressure I would remove it. That way I loose just a bit of refrigerant vs adding just a bit of air.
@jhhvacplumbing19448 жыл бұрын
Ralph is the mini split king , came out real nice
@NorCal-refrigeration8 жыл бұрын
I always braze the EVAP connections. Makes it zero maintenance at the connection point. Enjoyed the install. Great tip with the hilmore on the pvc.
@GlennnD6 жыл бұрын
We just bought a new house and I'm thinking of buying a HVAC unit for our bedroom. Never connected or actually touched one.. But very confident to say that I will follow up this tip! Have my experience with flares on brake lines and pressure air.. Thanks !
@keesdejong46096 жыл бұрын
Im from the netherlands... and we NEVER flare ever we always braze and im looking at these american techs all flaring and im still amazed most of the techs there are still flaring there i find flares so weak and they can so easily leak compared to brazing.. even on school where we learn the job they barely learn flaring
@fridgydownunder67348 жыл бұрын
Nice job Mr.Ralph, I hope I can see some more split install in your channel.
@marvinostman5223 жыл бұрын
What size Allen wrench does service valve take? A 3/16 doesn't fit. I specifically ask a supply house for the adapter to open the valve. I didn't look at it close as I was in a hurry. When I went to use it it wouldn't fit, turns out it was a 3/16. I know not all of them are different but Mitsubishi is..
@michaelbaldwin3356 Жыл бұрын
If brazing on a mini split voids the warranty, then I guess I shouldn’t have replaced the EEV or compressor on some units lol. Better question is why do they have these parts for warranty replacement?
@titolopez42704 жыл бұрын
Great video, I'm currently trying to understand why a MUZ-GL09NA is not working and giving my the 6 light flashing at the condensor. I verified all my connections and I am also getting proper voltage.
@justinfrias90308 жыл бұрын
I was talking to a Mitsubishi rep last week he said there's no problem with brazing their equip.
@dfj5553 жыл бұрын
There was no Sheetrock in the room behind the head unit. How are they going to install that? Aren't you suppose to run a plastic tube inside the wall?
@jamessnow77587 жыл бұрын
when you removed your micron gauge I swear I heard the vacuum pump get loud. couldn't air enter through the Schrader under high vacuum?
@mtay654 жыл бұрын
no problem, schrader valve closes under 1 nanosecond :)
@drpipe9 ай бұрын
Thanks so much.. Im new to Hvac... Seasoned Heating Engineer here in the Uk... Im impressed and Pleased to have learnt from you the Cut the flares off trick Thank you.. Question.. Is there a Need for the Flares at the outdoor Unit Can these ever be Brazed... Clearly you would need a Different Fitting at the Unit Which in turn answers the question ! Thanks for posting
@mikeroerig24996 жыл бұрын
This video was frustrating. At 17:58 you were explaining the valves but the camera was on your face.
@normala32273 жыл бұрын
How about showing what you're doing with the valves while talking?
@eddiehair18 жыл бұрын
excellent overview of the installation of the mitsubishi mini splits. thanks for sharing the information.
@TandNServices8 жыл бұрын
+HeadHunterTwo Kilo thank you, much appreciated
@ALIDIY0073 жыл бұрын
Doesn't this unit come pre charge? Why vacuum it out and re charge?
@hvacman778 жыл бұрын
Nice Job I have been Brazing them since the late 90's never had a issue. didn't use nitrogen back then either
@ronpossick4 жыл бұрын
I think there is a minimum distance between the two units which there does not seem to be.
@DonBallew8 жыл бұрын
thanks for this, it was very nice to see this done since i am about to install my first one in the next week or so
@dgnytro3 жыл бұрын
Hole for wall unit was drilled a little to low when head is on the wall you can see it on bottom right side of unit I put a magnetic level there to make sure I have the bottom of my hole saw up enough great vid
@cengeb7 жыл бұрын
BUT, putting the unit in place before the siding is up, could make for it getting damaged, when they do the siding, why not wait?
@rickevoli34847 жыл бұрын
cengeb .
@benhawver26647 жыл бұрын
Your a dumbass your comments are not needed
@masterdebater87576 жыл бұрын
siding doesn't require much room to install I see no issues here.
@dylanreischling41516 жыл бұрын
Ben Hawver I don’t think your comment was need either.....
@99cachorro3 жыл бұрын
Mitsubishi makes superior mini split equipment, but who doesn't know that? Nice install
@MarkDrumzEntertainment8 жыл бұрын
Question, why didn't you pull a vacuum from the suction line and Liquid line at the same time?
@TandNServices8 жыл бұрын
+Mark Drumz there's only one port on mini splits.
@cengeb7 жыл бұрын
it goes though both from the evaporator, EZ PZ
@MarkDrumzEntertainment8 жыл бұрын
So there is a low and hi side but you only pull vacuum from low suction side?
@jeromyevans41518 жыл бұрын
there is only one port on the smaller units. pulls vack threw the indoor unit. the LEV is not fully closed.
@HVACChillin8 жыл бұрын
Doesn't the flare fitting have a strainer in it? I prefer brazing myself.
@bgregg553 жыл бұрын
I'm with you on leaving the lineset exposed.
@cengeb7 жыл бұрын
Did you purge it with vacuum after pulling a vac 2 times? As per the instructions?
@71dembonesTV7 жыл бұрын
Nice install. I don't usually do these so it was a good refresher course. Going to do one of these tomorrow, definitely will be brazing those evap connections in and will be mindful of the bad factory flares at the condenser. Also going to use the swaged 1/2" pvc trick. I assume the normal bell-end is too big?
@robertdiserio97485 жыл бұрын
How did you do the heat load calc for this unit ? Diamond system builder ?
@brb408wpb3 жыл бұрын
My friend needs the inside unit replaced due to a crack/leak. The company is quoting $1,500 to remove the existing wall part of the unit and replace it. Unit is covered under warranty. What would you estimate the level of effort to be? Price sound fair? Based on your video, I think they need to drain the coolant, cut a hole in the wall to get to the wiring, drain, and copper pipes, remove existing unit, hang new unit, make connections, recharge system, and patch the drywall. Great videos! Thanks.
@efman2k38 жыл бұрын
Great videos Ralph. Thanks for posting!
@qwer012306 жыл бұрын
I am buying a mits split unit. The single zone 12btu.. MSZGL12NA model. Can I run the line set and drip drain on the other side.? I believe he installed it coming out the left side of unit I would need it to come out right side due to placement of compressor. Thank u!
@ERAUWeatherMan096 жыл бұрын
Leaves out all the detailed parts of the installation
@sprockkets4 жыл бұрын
That's obviously intentional. This isn't a how-to video.
@ERAUWeatherMan094 жыл бұрын
Still useful. I installed my system over a year ago and still running strong. Saved a ton of money too
@latesilvan40045 жыл бұрын
Was the camera guy drunk? He did a great job completely missing the part of what valve did you open or close rendering the video worthless.
@sprockkets4 жыл бұрын
That's obviously intentional. This isn't a how-to video.
@normala32273 жыл бұрын
Pressure test again to make sure flare fittings at condenser is not leaking.
@jeffstefani32257 жыл бұрын
Great Video Ralph , I'm out here in Phoeniz Arizona I was just wondering have you had any Line"s kink from the downward turn (from inside to outside down the wall) that almost a 90 degree ben, I would love to hear your thoughts. And thanks againg for all the great quality videos and giving back..
@vaccumme8 жыл бұрын
I wonder how these systems remove humidity from the structure ?
@Bajaheat8 жыл бұрын
Like an air conditioner
@rezkrezk96804 жыл бұрын
How many square feet the system will cover it will be enough for apartment two bedroom &living room
@pghworkoutbuddy8 жыл бұрын
Good video. What's the minimum distance the unit can be from the wall? (I have a property line consideration...every inch matters.)
@rezkrezk96804 жыл бұрын
How much did cost to install that system
@Jerryh318 жыл бұрын
Can you flow nitrogen when you braze the connections?
@hvactecster798 жыл бұрын
Nice clean install. Great job !! Take care, Brett
@TandNServices8 жыл бұрын
+hvactecster79 thanks Brett
@harrydickson45758 жыл бұрын
Excellent job Ralph looks great
@TandNServices8 жыл бұрын
+Harry Dickson thanks Harry
@airecraft18 жыл бұрын
I'll tell you what , we do quite a few Mitsubishi systems and the flares can be enough to drive a guy crazy . We use orbital flare tools , torque wrenches and still get the random leaker on a pressure test. I still love those machines though
@ThePete24328 жыл бұрын
ralph, do you ever use the white armaflex linesets? you can pull them through the toughest holes without even getting a tear. I love em
@olegshvets8 жыл бұрын
Are you talking about PDM and PAIRCOIL? We only use those. Work great for us. A little expensive but saves bunch of time
@josemaisonet85047 жыл бұрын
The best mini split tutorial out there !. Good job !. Thanks for sharing.
@ItsMeJbird8 жыл бұрын
how many Sq feet can that cool comfortably..?
@roksnowboy8 жыл бұрын
Wondering how much would this cost?
@robinsonguevara5668 жыл бұрын
What kind of utility boots and work pants do you have on?
@craigoldenburg25848 жыл бұрын
just imagine first heat pumps in Canada and no heater for outside coil have fun they have now we can get to minus 35 wish I had pics of coil looked like angry badger got stuck in it
@mikecaffery88327 жыл бұрын
I have a 1500 sq.ft. house with a 500 sq.ft. garage attached built in 2001. My wife parks her car in one half of the garage and I use the other half as my shop, would it be feasible to condition the air in the garage and inside the house using a multi zone mini split unit? I live in central Indiana so do you think I should keep the furnace for when it gets really cold?
@mikepagel84188 жыл бұрын
nice video Ralph.. but I'll have to test the theory of a valve core holding a 138 micron vacuum with no cap on it. lol
@jetg20594 жыл бұрын
How much for the whole job
@bbm88734178 жыл бұрын
Nice install Ralph
@quivera86heights7 жыл бұрын
It puts about 4000 microns depending how quick you break the seal in a vacuum .
@eddiesellers85228 жыл бұрын
Great video as always. Quick question, If you have a lineset less than 10' ,on a mini split, how much charge to you remove?
@TandNServices8 жыл бұрын
+Eddie Sellers you don't have to remove any refrigerant. You only need to add if your linesets are over 25 ft.
@lsantana81233 жыл бұрын
@@TandNServices hi, your videos are great, question if you have a total of 40ft additional line sets, do you add additional R410A based on 40ft or just the difference of 15ft.
@johnisraelhvac20198 жыл бұрын
Looks great Ralph!!!!
@hvacrjunky61198 жыл бұрын
Looks nice and clean.
@woodway118 жыл бұрын
Good video as usual Ralph but a question comes to mind...would you braze that line set if the evaporator unit was mounted on an interior wall rather than an exterior wall. Most of your install videos are done directly to an exterior wall, which is ideal and necessary but what's your thought when the wall mounted unit is on an interior wall where the line set would then have to run maybe five to ten feet to get to an exterior wall?
@jeffshannon72824 жыл бұрын
Why didn't you braze the connections to the mini-split also?
@drexelrahming89058 жыл бұрын
Nice job neat and easy to follow
@gonzgarr15928 жыл бұрын
great job with some great tips thanks
@earnestthompson67636 жыл бұрын
Nice Job Ralph I run my line set thae same way. Where did you run your electric from your beaker to your diconnect? No big deal I was just curious... Again great work!!!
@darkbeekeeper8 жыл бұрын
Well done Ralph 👍
@lee-johnson8 жыл бұрын
Guess you couldn't get lines in wall. I like the pvc drain swedge !
@TandNServices8 жыл бұрын
+Lee Johnson I always run it on the outside of the wall if I can. I just prefer it that way.
@incognitotorpedo426 жыл бұрын
Well, it can be a PITA to get a lineset through a finished wall, but it sure looks nicer. Some HOAs will not allow lines to run outside.
@kendallfitzgerald85996 жыл бұрын
I've done it both ways over the years if it's new construction I go in the wall if it's existing space I go through the wall, it can b made to look good eather way
@heartofsoul8 жыл бұрын
Ralph, I'm installing a MSZ-GE18NA , I've cut the line set length to 10 feet, which is what it looks like you did on this install. Did you compensate the factory charge at all for the shorter line set? Will they run fine with the factory charge at a 10 ft. line length? Thanks, for any input on this issue.
@richardmitchell51298 жыл бұрын
Great job as always and explanations too. My only concern is why are you still horse, is everything ok just worried about one of the best guys on here.
@TandNServices8 жыл бұрын
+Richard Mitchell thank you for the great compliment. My voice is back now. I had bronchitis about a month ago and all the coughing messed my voice up but it's back now. It just took longer to come back because I wouldn't shut up and rest my voice.
@richardmitchell51298 жыл бұрын
Lol thanks Ralph, was just concerned about you. Your son working with you this summer. As always keep up the great work.
@kolochodelrio12348 жыл бұрын
Is this a 240v then?
@franciscrasto4 жыл бұрын
240volt supply 2phase+neutral and ground.
@335alien3357 жыл бұрын
Nice job, other than the bottom of the line set hole being visible.
@georgesummerlin16022 жыл бұрын
That bird is fucking with the dog!!!! Listen to the bird and the dog at the beginning of the video!! Love it
@OIC-es6pi3 жыл бұрын
Thanks for sharing
@rodneyjames57837 жыл бұрын
Hey Ralph, great video, did you run the power circuit for the mini split?
@sergiocosta26458 жыл бұрын
Hi Ralph, are all mini splits pre-filled with Fridgerant?
@TandNServices8 жыл бұрын
+TCB Mechanical they come precharged for 25 ft of lineset
@jojitperlado61128 жыл бұрын
great job men,,, keep it up,,,
@jeanpaulvargas3645 Жыл бұрын
Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) kzbin.infoUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.
@ggleisberg8 жыл бұрын
"Un-OSHA approved ladder" lol... Love it!
@Andrew-xs4qy5 жыл бұрын
its residential.. whats osha lol
@cengeb7 жыл бұрын
Flare nuts eliminate using flames near flammable stuff.
@robertparker5254 жыл бұрын
This video is sponsored by LOWES....NEVER STOP IMPROVING.
@RobHVAC8 жыл бұрын
Nice work
@TandNServices8 жыл бұрын
Thanks Rob
@georgesiatos98488 жыл бұрын
great work!!!!
@lyem6544 жыл бұрын
He didn't follow the factory instruction to use Nitrogen gas to purge the air/moisture out the line set 2 times after vacuum. He cut corner.
@jasonking29438 жыл бұрын
great video, I'm in the greater Birmingham Alabama area. this spring I'm adding a sun room on the house. 20x16 this is what I have in mind to cool the area. what's the avg cost of such unit?
@cengeb7 жыл бұрын
super efficient, mini splits are the way to go. Mitsubishi, quiet, efficient reliable. Size it properly and you will love it! Heating and cooling
@retagila4 жыл бұрын
Thank you didn’t show the connections😒
@musititlan19705 жыл бұрын
I was taught that line set in a mini split system , never braze it! brazing residues will affect the unit!
@clarkgwozdecki67825 жыл бұрын
Nitrogen will keep the lines clean
@fedboy6014 жыл бұрын
Angel Lopez so what do you do with you’re extra line set ?
@Dillonmechanical2 жыл бұрын
Awesome
@Andres-sr7uv2 жыл бұрын
I though this was a DIY project but I guess not. I’ll have to hire a hvac guy out here in California. 😂
@doddgarger68064 жыл бұрын
I've seen York systems cheap and it's said they're a rebadged Mitsubishi
@emmettkelly74655 жыл бұрын
This guy is NOT a professional. Not one hint of plumber's crack. How can you be a pro with no pot belly, and no butt hanging out? Excellent video though. Thanks for sharing.
@sadhvacman72388 жыл бұрын
👍
@ItsMeJbird8 жыл бұрын
nice job though!
@jasongenovajr.7766 жыл бұрын
Steve Lav would of put a Goodman in and charged 25 thousand yes mama
@SnickasBah5 жыл бұрын
Jason Genova Jr. lol
@martinhudson26575 жыл бұрын
Lol your fired! Bent the copper pipe and don’t even know if you put a kinky in the line!
@zualfredo4 жыл бұрын
safety second! Taking high risk for not using the proper stepladder.
@jspinosa507 жыл бұрын
I was amazed at the stupidity of Mitsubishi. Making such a quality AC unit with the worst flare I've ever seen. My unit had scratches in the flare and of course, they leaked behind the evaporator!! Sorry I didn't take your advice. Now I'm paying!
@nman25635 жыл бұрын
I believe the line set is not supplied by Mitsubishi. It is sold separately by the AC company.
@evelynperez7576 Жыл бұрын
The mashine it's brazed with a robot inthe manufacturer..you not a robot..men
@evelynperez7576 Жыл бұрын
Not good my friend?nononono. ..first get a pro stepe. I have I later on my truck ill give to you. .then e Wen you bended the pipe u have to use the sprint benders. Tools they way you did. It's not good... you flated. The pipe. .. the sprint cos 6 dollars..men.