Awesome video. I always wondered how to do some kind of test like this to support me saying, " Drive is bad boss".
@canaldamanutencao4446
@canaldamanutencao4446 3 жыл бұрын
Very cool. Very well explained, I would like to congratulate you for the initiative.
@elmoncho72
@elmoncho72 2 жыл бұрын
Great video that helps me to understand deeper in VFDs drive field
@NLocus1
@NLocus1 3 жыл бұрын
Excellent Video. If you have a problem with your control board, this may also be a cause of IGBT Gate short-circuited. Beware. The gates could not be accessed from outside, dismantle and check.
@jesusortiz6842
@jesusortiz6842 2 жыл бұрын
You are incredible. Thanks for teaching us.
@maulandhall2340
@maulandhall2340 5 жыл бұрын
Thanks so much i am grateful for this online course very much appreciate bless
@victorpana4837
@victorpana4837 Ай бұрын
Very useful courses! Thanks!
@sthabilemthembu2854
@sthabilemthembu2854 2 жыл бұрын
great video What would be the readings if there was a short circuit?
@laworder6092
@laworder6092 4 жыл бұрын
Thank you sir. Well explained I salut for your generosity.
@electronictech785
@electronictech785 4 жыл бұрын
So nice of you
@jorgeresendiz1932
@jorgeresendiz1932 3 жыл бұрын
excellent video. Thank you. Very thorough explanation.
@compressorman43
@compressorman43 2 жыл бұрын
Great explanation thanks . How we test hi hight volts for leak iGBT
@fernandomartins7261
@fernandomartins7261 3 жыл бұрын
Thanks a million for your great explanation and effort. Kind regards.
@haroldlanglois8986
@haroldlanglois8986 3 жыл бұрын
Great explanation, very understandable. thanks
@aghvacappliancerepair4120
@aghvacappliancerepair4120 3 жыл бұрын
Awesome video man, gave a great explanation on how to check the bridge rec and igbt, I will defiantly be using this method from time to time.
@cheyguvera9680
@cheyguvera9680 2 жыл бұрын
Great explaination sir, god bless you
@AA-hu9mh
@AA-hu9mh 3 жыл бұрын
Awesome explanation 👏🏻
@COFFEE23409
@COFFEE23409 4 жыл бұрын
Excellent video. I never considered that method of testing.
@sudhirpatil3434
@sudhirpatil3434 4 жыл бұрын
Very nice explanation!
@mattivester7353
@mattivester7353 2 жыл бұрын
Could you discuss what the DC Buss terminals are? I see there are 4 terminals.
@wirenutt57
@wirenutt57 3 жыл бұрын
How about checking the rectifier diodes with reverse polarity? You checked the forward voltage drop, but if you switch the leads, you should get an open. If you get anything other than high resistance, the diode could be shorted. Take into account the fact that the huge filter caps will take a bit to charge, and you might see a temporary short because of that.
@cdrive5757
@cdrive5757 Жыл бұрын
Have you ever revisited your comment since you posted it? I know it must have made sense to you when you posted it but think about what you said. Wakodahatchee Chris
@makashem8704
@makashem8704 2 жыл бұрын
Dear Friend, Thank you for your video, i would like to know that i don't have 3 phase 380v.line in my workshop. Only 220v. available, how i can check my vfd after repair it? Plz let me know it will be very useful to me. Thanks
@therealMikhailBaryshnikov
@therealMikhailBaryshnikov 2 ай бұрын
Great explication thank you!
@guptabrothers1938
@guptabrothers1938 2 жыл бұрын
Very good explanation carry on thanks for it.
@nikhilviswam9546
@nikhilviswam9546 2 жыл бұрын
Great information. Kuuyaaa.
@henrymendez5934
@henrymendez5934 3 жыл бұрын
Thanks Lou very informative. How do I reach you?
@brianb5779
@brianb5779 4 жыл бұрын
Anything different w allen bradley 4's and 40's with this kind of testing?? Also thank you for all your info
@labenrosatase
@labenrosatase Жыл бұрын
Thanks for your tutorial .. gob bless sir..
@supertech2853
@supertech2853 2 жыл бұрын
Thank you for the video it is very helpful
@dizzolve
@dizzolve 2 жыл бұрын
can you test when powered up
@samsirjaafar364
@samsirjaafar364 4 жыл бұрын
Great explaination. Tqvm.
@MDsayed-xz7df
@MDsayed-xz7df 2 жыл бұрын
I have a question sir. ig5a lsis vfd. It’s showing low voltage when i run the drive. What should i do sir? We are audience waiting for your kind information. Thank you sir.
@samsirjaafar364
@samsirjaafar364 4 жыл бұрын
Good Evening. I have washing machine (laundry) using single phase input with 3 phase motor. My priblem is.... The motor body tempreture very hot, touch by hand. Than sometime, motor not running. In this case, motor problem or VFD problem? Plesse advise.
@electronictech785
@electronictech785 4 жыл бұрын
A single phase being turned back to 3 phase is already not the best way to drive a motor but with that being said, I would check the motor out first if its heating up.
@donaldpatan930
@donaldpatan930 5 жыл бұрын
Thank you another day another learn
@gatedavid95
@gatedavid95 3 жыл бұрын
Good explanation
@ksteelcambodia595
@ksteelcambodia595 4 жыл бұрын
i have an AC motor inverter EDS2000 model. and i followed your instructions to test it. the result showed the same as in your video instructions, but when i power it up and press RUN, it showed error E013. could you recommend something?
@electronictech785
@electronictech785 4 жыл бұрын
I don't have the manual for the drive. What does the E013 fault?
@janmalesela2510
@janmalesela2510 4 жыл бұрын
Hi, this test can be conducted in a new vfd. Or ii need to power it first .then disconnect the cables . I tested in a new vfd but everything is open. That's my question. Again what if the cable is faulty or motor . One say whole the cable was faulty the vfd was showing dc bus over voltage can you explain that to ne
@electronictech785
@electronictech785 4 жыл бұрын
Yes, new and used. You are checking the bridge rectifier and the IGBTs. This test is not for testing cables so the line input cables and motor cables should be disconnected. DC Bus over voltage means that the voltage on the Bus has exceeded the VFDs threshold.
@janmalesela2510
@janmalesela2510 4 жыл бұрын
@@electronictech785 hi sir, I tested new vfd everything is one. Testing diode forward bias is open. Testing Igbt is open. Now I was just asking need to charge the resistor or not .
@ricardofelizco8323
@ricardofelizco8323 4 жыл бұрын
thxs for video learning...can you give some information and application of SEMITRNS M SKKR400/0.2-BVR for VFD design and function..thank you and best regards Sir
@joycandromojumdar
@joycandromojumdar 2 жыл бұрын
Dear sir thank you this inverter is diagram please
@tankmanikhapangi6279
@tankmanikhapangi6279 2 жыл бұрын
Sir how can resolve problem fault code 5696 pu state feedback in abb acs 880 vfd drive
@emedosichijioke4557
@emedosichijioke4557 3 жыл бұрын
pls i did my static check and my igbt module is good but yet i didnt get power output even when the drive is running using the local mode
@joycandromojumdar
@joycandromojumdar 2 жыл бұрын
This inverter schematics diagram please.
@jerrellmahan4814
@jerrellmahan4814 4 жыл бұрын
Most of the VFDs sold today don't provide the + and - terminals for the DC bus. How can the diodes be checked without the + and - terminals?
@electronictech785
@electronictech785 4 жыл бұрын
In that case, you'll have to get access to the bus caps which would require you to take it apart. The only time we see VFDs with no + and - terminals are the small Horse Power VFDs.
@jerrellmahan4814
@jerrellmahan4814 4 жыл бұрын
@@electronictech785That's what I was afraid of. Thanks for your help.
@willskee7817
@willskee7817 3 жыл бұрын
Valuable information thanks buddy
@samuelgantala5253
@samuelgantala5253 4 жыл бұрын
Thanks i've learned the basic test.
@ashishrsahu
@ashishrsahu 4 жыл бұрын
Please make a video on siemens simovert 430 440 drive and abb dcs drive 550 checking
@jsteele42378
@jsteele42378 5 жыл бұрын
is this want I use to work with dealing with Variable Frequency Drives ?
@electronictech785
@electronictech785 5 жыл бұрын
The higher horsepower VFD is profitable. You have to know what industry and where they are at.
@jsteele42378
@jsteele42378 5 жыл бұрын
@@electronictech785 Wow you are getting into some really super tech and more that nice to know subjects ! ! ! ! ! !
@ezhavaganesh
@ezhavaganesh 4 жыл бұрын
Best video i found superb thanks a lott
@electronictech785
@electronictech785 4 жыл бұрын
Most welcome 😊
@gershonfroumine6827
@gershonfroumine6827 Жыл бұрын
Thank you LU
@015diesel
@015diesel 3 жыл бұрын
Thanks for the video
@michaelshansen7070
@michaelshansen7070 5 жыл бұрын
Wow great, now I understand...
@alankellerhouse1249
@alankellerhouse1249 2 жыл бұрын
Thez video on. Ac drive was very good Iexplain how the. Ac drive works I would like to see trouble shout videos and =epairs.
@zainabbas2524
@zainabbas2524 5 жыл бұрын
Thought it would be more indepth and more visual .
@RyanJardina
@RyanJardina 5 жыл бұрын
How more in depth do you need? The only thing that's really missing is he should be drinking a bottle of whiskey.
@FixItAll1
@FixItAll1 4 жыл бұрын
PB where is conected?
@aldosejacobite5381
@aldosejacobite5381 3 жыл бұрын
How to contact u sir
@donovanj8840
@donovanj8840 4 жыл бұрын
Job well done..
@kimtran8540
@kimtran8540 3 жыл бұрын
Thank you.
@jsteele42378
@jsteele42378 5 жыл бұрын
I can't seem to remember is 3 phase " each leg is 70 degrees or 30 degrees out of phase with each other " ? chit seems I wouldn't for get and maybe I wrong.
@electronictech785
@electronictech785 5 жыл бұрын
For a three-phase AC voltage source, the phase shift is 120° with respect to each other
@jsteele42378
@jsteele42378 5 жыл бұрын
@@electronictech785 Yep sorry I now remember thanks so much ! I was thinking that this was the reason that several motors and compresses did need starter cap if you had 3 phase.
@Jugc0006
@Jugc0006 2 жыл бұрын
Awesome we'll cover
@dr-gaberibrahim5268
@dr-gaberibrahim5268 5 жыл бұрын
Thanks so much
@suhailthanikal
@suhailthanikal 5 жыл бұрын
Thanks
@electronictech785
@electronictech785 5 жыл бұрын
my pleasure!!
@multisado7562
@multisado7562 3 жыл бұрын
Hello Sir, I sell electromagnetic heater , I wish can repair by our self can you teach us ? I would send the photos of electromagnetic heater if can teach for us to repair it..
@bismillahelectronicsindust9824
@bismillahelectronicsindust9824 5 жыл бұрын
Sir I teach Ac drive repairing video upload thanks
@electronictech785
@electronictech785 5 жыл бұрын
you're welcome!!
@rameshodedara1401
@rameshodedara1401 5 жыл бұрын
Hello sir, Thanks for your effort. => As power electronics engineer, I know this thing, i thought u may explain testing of control circuit, or driver circuit problem or feedback portion at signal level. Very disappointed.
How To Test an IGBT
13:01
ElectroTec
Рет қаралды 373 М.
Sigma girl VS Sigma Error girl 2  #shorts #sigma
0:27
Jin and Hattie
Рет қаралды 124 МЛН
Jaidarman TOP / Жоғары лига-2023 / Жекпе-жек 1-ТУР / 1-топ
1:30:54
How To Measure Variable Frequency Drives (VFD) - Filtered vs. Unfiltered
9:40
Engineered Air Balance
Рет қаралды 37 М.
HOW TO TEST IF A VFD ( Variable Frequency Drive ) IS BAD WITH A MULTIMETER
11:57
How To Test a VFD (variable frequency drive)
9:26
Engineering Support 4 Food and Drink Manufacturers
Рет қаралды 70 М.
Variable Frequency Drives Explained | VFD Basics - Part 1
8:35
3 Skill Sets To Become A Great Electronic Tech
15:13
Electronic Tech
Рет қаралды 33 М.
How To: Troubleshoot VFDs
11:30
Radwell International
Рет қаралды 42 М.
[436] How To Test IGBT / How to Check IGBT with Mulimeter / Why IGBT Damage
15:39
Sigma girl VS Sigma Error girl 2  #shorts #sigma
0:27
Jin and Hattie
Рет қаралды 124 МЛН