Awesome video. I always wondered how to do some kind of test like this to support me saying, " Drive is bad boss".
@canaldamanutencao44463 жыл бұрын
Very cool. Very well explained, I would like to congratulate you for the initiative.
@elmoncho722 жыл бұрын
Great video that helps me to understand deeper in VFDs drive field
@NLocus13 жыл бұрын
Excellent Video. If you have a problem with your control board, this may also be a cause of IGBT Gate short-circuited. Beware. The gates could not be accessed from outside, dismantle and check.
@jesusortiz68422 жыл бұрын
You are incredible. Thanks for teaching us.
@maulandhall23405 жыл бұрын
Thanks so much i am grateful for this online course very much appreciate bless
@victorpana4837Ай бұрын
Very useful courses! Thanks!
@sthabilemthembu28542 жыл бұрын
great video What would be the readings if there was a short circuit?
@laworder60924 жыл бұрын
Thank you sir. Well explained I salut for your generosity.
@electronictech7854 жыл бұрын
So nice of you
@jorgeresendiz19323 жыл бұрын
excellent video. Thank you. Very thorough explanation.
@compressorman432 жыл бұрын
Great explanation thanks . How we test hi hight volts for leak iGBT
@fernandomartins72613 жыл бұрын
Thanks a million for your great explanation and effort. Kind regards.
@haroldlanglois89863 жыл бұрын
Great explanation, very understandable. thanks
@aghvacappliancerepair41203 жыл бұрын
Awesome video man, gave a great explanation on how to check the bridge rec and igbt, I will defiantly be using this method from time to time.
@cheyguvera96802 жыл бұрын
Great explaination sir, god bless you
@AA-hu9mh3 жыл бұрын
Awesome explanation 👏🏻
@COFFEE234094 жыл бұрын
Excellent video. I never considered that method of testing.
@sudhirpatil34344 жыл бұрын
Very nice explanation!
@mattivester73532 жыл бұрын
Could you discuss what the DC Buss terminals are? I see there are 4 terminals.
@wirenutt573 жыл бұрын
How about checking the rectifier diodes with reverse polarity? You checked the forward voltage drop, but if you switch the leads, you should get an open. If you get anything other than high resistance, the diode could be shorted. Take into account the fact that the huge filter caps will take a bit to charge, and you might see a temporary short because of that.
@cdrive5757 Жыл бұрын
Have you ever revisited your comment since you posted it? I know it must have made sense to you when you posted it but think about what you said. Wakodahatchee Chris
@makashem87042 жыл бұрын
Dear Friend, Thank you for your video, i would like to know that i don't have 3 phase 380v.line in my workshop. Only 220v. available, how i can check my vfd after repair it? Plz let me know it will be very useful to me. Thanks
@therealMikhailBaryshnikov2 ай бұрын
Great explication thank you!
@guptabrothers19382 жыл бұрын
Very good explanation carry on thanks for it.
@nikhilviswam95462 жыл бұрын
Great information. Kuuyaaa.
@henrymendez59343 жыл бұрын
Thanks Lou very informative. How do I reach you?
@brianb57794 жыл бұрын
Anything different w allen bradley 4's and 40's with this kind of testing?? Also thank you for all your info
@labenrosatase Жыл бұрын
Thanks for your tutorial .. gob bless sir..
@supertech28532 жыл бұрын
Thank you for the video it is very helpful
@dizzolve2 жыл бұрын
can you test when powered up
@samsirjaafar3644 жыл бұрын
Great explaination. Tqvm.
@MDsayed-xz7df2 жыл бұрын
I have a question sir. ig5a lsis vfd. It’s showing low voltage when i run the drive. What should i do sir? We are audience waiting for your kind information. Thank you sir.
@samsirjaafar3644 жыл бұрын
Good Evening. I have washing machine (laundry) using single phase input with 3 phase motor. My priblem is.... The motor body tempreture very hot, touch by hand. Than sometime, motor not running. In this case, motor problem or VFD problem? Plesse advise.
@electronictech7854 жыл бұрын
A single phase being turned back to 3 phase is already not the best way to drive a motor but with that being said, I would check the motor out first if its heating up.
@donaldpatan9305 жыл бұрын
Thank you another day another learn
@gatedavid953 жыл бұрын
Good explanation
@ksteelcambodia5954 жыл бұрын
i have an AC motor inverter EDS2000 model. and i followed your instructions to test it. the result showed the same as in your video instructions, but when i power it up and press RUN, it showed error E013. could you recommend something?
@electronictech7854 жыл бұрын
I don't have the manual for the drive. What does the E013 fault?
@janmalesela25104 жыл бұрын
Hi, this test can be conducted in a new vfd. Or ii need to power it first .then disconnect the cables . I tested in a new vfd but everything is open. That's my question. Again what if the cable is faulty or motor . One say whole the cable was faulty the vfd was showing dc bus over voltage can you explain that to ne
@electronictech7854 жыл бұрын
Yes, new and used. You are checking the bridge rectifier and the IGBTs. This test is not for testing cables so the line input cables and motor cables should be disconnected. DC Bus over voltage means that the voltage on the Bus has exceeded the VFDs threshold.
@janmalesela25104 жыл бұрын
@@electronictech785 hi sir, I tested new vfd everything is one. Testing diode forward bias is open. Testing Igbt is open. Now I was just asking need to charge the resistor or not .
@ricardofelizco83234 жыл бұрын
thxs for video learning...can you give some information and application of SEMITRNS M SKKR400/0.2-BVR for VFD design and function..thank you and best regards Sir
@joycandromojumdar2 жыл бұрын
Dear sir thank you this inverter is diagram please
@tankmanikhapangi62792 жыл бұрын
Sir how can resolve problem fault code 5696 pu state feedback in abb acs 880 vfd drive
@emedosichijioke45573 жыл бұрын
pls i did my static check and my igbt module is good but yet i didnt get power output even when the drive is running using the local mode
@joycandromojumdar2 жыл бұрын
This inverter schematics diagram please.
@jerrellmahan48144 жыл бұрын
Most of the VFDs sold today don't provide the + and - terminals for the DC bus. How can the diodes be checked without the + and - terminals?
@electronictech7854 жыл бұрын
In that case, you'll have to get access to the bus caps which would require you to take it apart. The only time we see VFDs with no + and - terminals are the small Horse Power VFDs.
@jerrellmahan48144 жыл бұрын
@@electronictech785That's what I was afraid of. Thanks for your help.
@willskee78173 жыл бұрын
Valuable information thanks buddy
@samuelgantala52534 жыл бұрын
Thanks i've learned the basic test.
@ashishrsahu4 жыл бұрын
Please make a video on siemens simovert 430 440 drive and abb dcs drive 550 checking
@jsteele423785 жыл бұрын
is this want I use to work with dealing with Variable Frequency Drives ?
@electronictech7855 жыл бұрын
The higher horsepower VFD is profitable. You have to know what industry and where they are at.
@jsteele423785 жыл бұрын
@@electronictech785 Wow you are getting into some really super tech and more that nice to know subjects ! ! ! ! ! !
@ezhavaganesh4 жыл бұрын
Best video i found superb thanks a lott
@electronictech7854 жыл бұрын
Most welcome 😊
@gershonfroumine6827 Жыл бұрын
Thank you LU
@015diesel3 жыл бұрын
Thanks for the video
@michaelshansen70705 жыл бұрын
Wow great, now I understand...
@alankellerhouse12492 жыл бұрын
Thez video on. Ac drive was very good Iexplain how the. Ac drive works I would like to see trouble shout videos and =epairs.
@zainabbas25245 жыл бұрын
Thought it would be more indepth and more visual .
@RyanJardina5 жыл бұрын
How more in depth do you need? The only thing that's really missing is he should be drinking a bottle of whiskey.
@FixItAll14 жыл бұрын
PB where is conected?
@aldosejacobite53813 жыл бұрын
How to contact u sir
@donovanj88404 жыл бұрын
Job well done..
@kimtran85403 жыл бұрын
Thank you.
@jsteele423785 жыл бұрын
I can't seem to remember is 3 phase " each leg is 70 degrees or 30 degrees out of phase with each other " ? chit seems I wouldn't for get and maybe I wrong.
@electronictech7855 жыл бұрын
For a three-phase AC voltage source, the phase shift is 120° with respect to each other
@jsteele423785 жыл бұрын
@@electronictech785 Yep sorry I now remember thanks so much ! I was thinking that this was the reason that several motors and compresses did need starter cap if you had 3 phase.
@Jugc00062 жыл бұрын
Awesome we'll cover
@dr-gaberibrahim52685 жыл бұрын
Thanks so much
@suhailthanikal5 жыл бұрын
Thanks
@electronictech7855 жыл бұрын
my pleasure!!
@multisado75623 жыл бұрын
Hello Sir, I sell electromagnetic heater , I wish can repair by our self can you teach us ? I would send the photos of electromagnetic heater if can teach for us to repair it..
@bismillahelectronicsindust98245 жыл бұрын
Sir I teach Ac drive repairing video upload thanks
@electronictech7855 жыл бұрын
you're welcome!!
@rameshodedara14015 жыл бұрын
Hello sir, Thanks for your effort. => As power electronics engineer, I know this thing, i thought u may explain testing of control circuit, or driver circuit problem or feedback portion at signal level. Very disappointed.