REFRIGERATION PUMP DOWN AND HOW TO CHANGEOVER COMPRESSOR?

  Рет қаралды 56,938

leckyjake

leckyjake

Күн бұрын

Here is the step by step procedure on how to pump down the provision refrigeration system onboard as well as the correct way on how to changeover the compressor.
#reefer #refrigeration #refrigerationcycle #refrigerationequipment #seafarer #seaman #airconditioner #hvac #refrigerationandairconditioning #leckyjake #electrician #electric

Пікірлер: 83
@antonioreyes7476
@antonioreyes7476 2 жыл бұрын
Another learning from my favorite KZbin channel. Mabuhay po kayo leckyjake.
@scorpiomarine-electrocutio7460
@scorpiomarine-electrocutio7460 2 жыл бұрын
Goodjob.this is very informative sir lecky.
@mahmoodhassan4537
@mahmoodhassan4537 Ай бұрын
The best ETO on the planet 👌
@dennisabad7862
@dennisabad7862 Жыл бұрын
full of information thank you sir for the free knowledge.
@BernieQuinia-fl3ed
@BernieQuinia-fl3ed 5 ай бұрын
T.y sir to gud explaination.gud bless
@akarl6578
@akarl6578 2 жыл бұрын
You are the best. Thank you from Greece
@dennisdumale5599
@dennisdumale5599 2 жыл бұрын
Thank you so much sir jake for these video. More power sir. And keep safe always. God bless to u & to ur famly🙏
@yousefhaeiri360
@yousefhaeiri360 2 жыл бұрын
Hi Lecky,thanks a lot please make an introduction video about the Boilers
@willrobbinson1
@willrobbinson1 2 жыл бұрын
boilers??? anyway like vid thanx
@yousefhaeiri360
@yousefhaeiri360 2 жыл бұрын
Marine Auxiliary boilers
@eduardcalong796
@eduardcalong796 Жыл бұрын
Thank you for this knowledge master lecky jake.. I had learn a lot.
@fenflyer
@fenflyer Жыл бұрын
Thanks for great videos 👍 Good video on twin compressor pump down 👍can you do video on inverter scroll refrigeration compressors , please 👍 I only worked on old twin 120 KW Sabroe piston compressors systems Amonia and R22 etc 😑 Thanks for great videos 👍
@princefernandes5789
@princefernandes5789 2 жыл бұрын
Excellent job 👏👏👏🛠🔧🛠🔨🔧 good explanation 😎😎😎😎
@judebrosas4663
@judebrosas4663 11 ай бұрын
Thank you sir this is a big help to me...thank you❤
@Tutorial_Ref_Aircon_more
@Tutorial_Ref_Aircon_more 2 жыл бұрын
Thank u for sharing sir
@leckyjake
@leckyjake 2 жыл бұрын
Thank you for watching
@arielcunanan4994
@arielcunanan4994 Жыл бұрын
Excellent tutorials
@mahboobKhan-uy7sm
@mahboobKhan-uy7sm 3 ай бұрын
❤❤❤❤❤
@markvillaspin6643
@markvillaspin6643 9 ай бұрын
Thank you Lect God Bless
@pedrojardim1163
@pedrojardim1163 2 жыл бұрын
Thanks for the very helpful and very good explanation 👍
@LinkWrayisGod
@LinkWrayisGod 2 жыл бұрын
Nice one Lecky! Greetings from Spain.
@cck1496
@cck1496 Жыл бұрын
Thanks but why do we need the system to be pumped down? Why we can't keep one compressor off (rather than isolating it)? Thanks.
@leckyjake
@leckyjake Жыл бұрын
normally the changeover is being done every month, you do not want any refrigerant in the line for the non running compressos as in will condense in the latter.you do not want liquid state refrierant to enter into your compressor.
@edwardjackson8183
@edwardjackson8183 2 жыл бұрын
😱🤯.. you blew my mind
@man15h
@man15h 2 жыл бұрын
Hello sir can you please suggest a book for understanding single line diagram and learn about switch gear and Power systems protection, relay setting and fault current calculation
@Winstly
@Winstly 2 жыл бұрын
husay sir!!!
@akarshanilkumar3461
@akarshanilkumar3461 3 ай бұрын
@khuatamipatheihhuaithulehl4769
@khuatamipatheihhuaithulehl4769 Жыл бұрын
Good
@rb1m426
@rb1m426 2 жыл бұрын
Present mr. Secretary 😊 about sa plc naman Sec.
@leckyjake
@leckyjake 2 жыл бұрын
Thank you
@aaronjettroehidalgo534
@aaronjettroehidalgo534 Жыл бұрын
Thank you sir!
@kiageungwirengrana5374
@kiageungwirengrana5374 2 жыл бұрын
Many thanks my bro
@paologringoescalante6916
@paologringoescalante6916 Жыл бұрын
Maraming salamat po. ❤
@joseenricoaguila5218
@joseenricoaguila5218 2 жыл бұрын
thank you
@leckyjake
@leckyjake 2 жыл бұрын
Thank you for watching
@kuldeepsingh8486
@kuldeepsingh8486 2 жыл бұрын
Thank you sir can you make video for same A.C change over . And can make video on main engine course in simple way.
@leckyjake
@leckyjake 2 жыл бұрын
Will keep on the list
@babaolowo35
@babaolowo35 2 жыл бұрын
Thanks 👍
@manzillegal1
@manzillegal1 Жыл бұрын
Leckyjake hello leck could you also make video of procedure of vaccum of the system too weather Aircon or reefer thanku you ver much in advance🙏
@jrahul8136
@jrahul8136 2 жыл бұрын
Please share how to trace electrical wiring diagrams...for example motor and starters circuit
@leckyjake
@leckyjake 2 жыл бұрын
I normally include the tracing on my troubleshooting videos
@jishnur9770
@jishnur9770 2 жыл бұрын
Hi Lecky, Frst of all thank you for your wonderful easy explanation on each of your video. Im having a trouble on my ushio ref system, which is no 1 compressor is getting frosted if i let the system run. Now i changed over to no:2 not pumping down , but by charging no 2. What may be the probable reasons for the frosting, no fluctuation in suction and discharge pressure. R417A was charged on no:1 last week.
@leckyjake
@leckyjake 2 жыл бұрын
i always depend on the pressures. but most of the times if you have frost in the suction you might have an overcharged of refrigerant
@jishnur9770
@jishnur9770 2 жыл бұрын
Thank you and hats off for the dedication towards sharing your experience. Always waiting for your videos.
@stonecold1553
@stonecold1553 2 жыл бұрын
Hi just want to share my insight. The trouble is your compressor is getting frosted. One main reason, the refrigerant on the suction line all the way to the compressor is not in vapor/gas form. A lot of reason way this happened, most notorious one is overcharge, malfunctioning expansion device, dirty/clogged evaporator coil, and etc. But base on the scenario you have stated it is more likely overcharge.
@dhruvrajchauhan4126
@dhruvrajchauhan4126 Жыл бұрын
Thank you
@leckyjake
@leckyjake Жыл бұрын
thank you for watching
@syedbasheer8210
@syedbasheer8210 2 жыл бұрын
👍👍👍
@leckyjake
@leckyjake 2 жыл бұрын
Thanks
@erwinhutapea2091
@erwinhutapea2091 Жыл бұрын
Thank you so much sir .. sir I will ask about high pressure. if vegetable ekspnsi V/v open high pressure more up until 1.8 and then direct trip .. iwhat problem sir?
@amoscolod1519
@amoscolod1519 Жыл бұрын
a very good explanation sir. you said that we need to run the compressor two times so if during the first time the low pressure switch activates how can we restart again the compressor or how will the compressor start again? will the pressure increase itself due to remaining refrigerant on the system?
@ivanfmartinezm
@ivanfmartinezm Жыл бұрын
You can force to start pushing manualy the main contactor from the compressor about 3 or 5 seconds.
@bt9604
@bt9604 2 жыл бұрын
Sir, plz do a video on insulated neutral system in ship 🙏🏻
@torohdelapan8352
@torohdelapan8352 Жыл бұрын
Please give education how to change oil the provision ref machine..thx
@antenehberhanu4467
@antenehberhanu4467 5 ай бұрын
My dear what is the problem of freezer room start and stop again and again even if refrigrant gas is infe amount in the system
@thantzinaung6650
@thantzinaung6650 Жыл бұрын
Sir, When you were pumping down the condenser of unit 1, the unit 1 was running in auto mode ?
@studywithssr338
@studywithssr338 2 жыл бұрын
Sir please video on circuit diagram reading
@markpaulofacun
@markpaulofacun Жыл бұрын
👍
@freemind6231
@freemind6231 Жыл бұрын
sir. acceptable npoba yung negative 17 s meat storage? gusto kc nila negative 20 medyo naggalangan ako galawin . tnx
@rafaelhijara9534
@rafaelhijara9534 2 жыл бұрын
So the switch of compressor is off already before the closing the service valve? Am i right?
@nelsonramirez7586
@nelsonramirez7586 2 жыл бұрын
Hello sir.. i just ask if you need to deactivate first or set some setting in the control to not activate the pressure switches while doing pump down??? Thank you in advance
@leckyjake
@leckyjake 2 жыл бұрын
good question, if the suction pressure switch is more than zero bar/MPa then adjust it to zero.
@nelsonramirez7586
@nelsonramirez7586 2 жыл бұрын
@@leckyjake Thank you sir.. God bless you always and takecare... one of your subscriber here 😊
@JerinMathew-rr6qs
@JerinMathew-rr6qs Жыл бұрын
Why crack open for suction side valve ??
@Tech-NO-City
@Tech-NO-City 2 жыл бұрын
Next time please add "What not to do" I learn more by learning from others mistakes.
@joalpsengineman4717
@joalpsengineman4717 2 жыл бұрын
Sir asan maganda .mag training sa pilipinas about electrical and reefer dto ako sa US as a Merchant Marine sa APL mahal ang training dto nasa $20k per training ng reefer at electrician and it takes 6 months
@bhongtorbs5685
@bhongtorbs5685 Жыл бұрын
Crack open lng ba talaga yan sir yong suction normaly? Or i full open mo rin yan.
@elecbaskogpogi2086
@elecbaskogpogi2086 2 жыл бұрын
Good day lec. I have a question I experience during pumping down discharge pressure is increasing until high pressure trip activated and suction pressure is not decreasing hard to activate the low pressure switch. What is the cause? For that reason I cannot properly pump down and changeover to another one compressor. Hope it will answer Thank you in advance.
@leckyjake
@leckyjake 2 жыл бұрын
first, the cooling should still be present during pump down. you can adjust the setting of your discharge pressure switch as per your manual max limit. 3rd. check for leak test on your suction side. the pressures you may be getting is the air that is goibg through your system
@elecbaskogpogi2086
@elecbaskogpogi2086 2 жыл бұрын
@@leckyjake thank you. Have a good day ahead.
@royceroneilramos
@royceroneilramos Жыл бұрын
Ano po yung dahilan bakit need munang naka crack open lang ang service valve ng suction side sa compressor 2? Thank you idol 🙂
@ninogonzales4621
@ninogonzales4621 Жыл бұрын
Sir leckyjake patulong naman yong fish room namin ayaw mag reach sa -18 ,hanggan-13 lang sya. Palaging nakabukas yong expansion valve kaya nag ice na yong evaporator. Kahit nag depros na kami ayaw pa din talaga tumaas . Patulong po. Salamat idol
@davidosei9560
@davidosei9560 2 жыл бұрын
Hello sir , I’m having a bachelors degree in Electrical and Electronic engineering and I will like to work on board . What are the steps I to go through before getting a seagoing job
@leckyjake
@leckyjake 2 жыл бұрын
It actually depends on your country if you are asking about requirements
@yaswanthsri2524
@yaswanthsri2524 2 жыл бұрын
u can do course called ETO
@srisatyasaidurgaprasad2380
@srisatyasaidurgaprasad2380 7 күн бұрын
How to join
@teslapower220
@teslapower220 Жыл бұрын
Haven't reefer containers made these systems obsolete?
@adepojuadewale1567
@adepojuadewale1567 2 ай бұрын
please can u send this unit diagram
@asifraza1663
@asifraza1663 6 ай бұрын
I want to join criuse line i have 5 year experience in Dubai can you help me
@randygalang4994
@randygalang4994 2 жыл бұрын
Chinese ka sir?
@leckyjake
@leckyjake 2 жыл бұрын
noypi ako
@randygalang4994
@randygalang4994 2 жыл бұрын
@@leckyjake Salamat sir....
@kaden2985
@kaden2985 2 жыл бұрын
ρгό𝔪σŞm
PROVISION REFRIGERATION TROUBLESHOOTING | Marine Electrician
8:38
HOW TO PUMP DOWN AND CHANGE OVER THE REEFER SYSTEM |Toping's World
10:29
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,5 МЛН
Blue Food VS Red Food Emoji Mukbang
00:33
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 9 МЛН
白天使选错惹黑天使生气。#天使 #小丑女
00:31
天使夫妇
Рет қаралды 14 МЛН
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 3,3 МЛН
AUTO PILOT POWER FAIL AND HOW TO READ WIRING DIAGRAM
11:52
leckyjake
Рет қаралды 38 М.
AUXILIARY BOILER NOT FIRING, TROUBLESHOOTING
9:38
leckyjake
Рет қаралды 38 М.
DIY Cascade Refrigeration System (Part I)
19:15
Hyperspace Pirate
Рет қаралды 264 М.
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 382 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 58 М.
Burnt VFD, Why?????
8:45
leckyjake
Рет қаралды 23 М.
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,5 МЛН