HOW TO CHARGE REFRIGERANT WITHOUT DIFFUSING ANYTHING IN THE ATMOSPHERE.

  Рет қаралды 81,286

leckyjake

leckyjake

Күн бұрын

Пікірлер: 149
@kabarotv6591
@kabarotv6591 2 жыл бұрын
Free knowledge from a world class seafarer. I hope your channel will be discovered more. You deserve all the commendation. thank you very much for the knowledge.
@leckyjake
@leckyjake 2 жыл бұрын
Thank you very much. Comments like this is enough to keep me going.
@thuweinmassoud9062
@thuweinmassoud9062 Күн бұрын
​@@leckyjake we learning from you do you have a group
@antonioreyes7476
@antonioreyes7476 2 жыл бұрын
Leckyjake is a world class Filipino ETO no doubt.
@leckyjake
@leckyjake 2 жыл бұрын
Very much appreciated. Thank you for your wonderful comment
@zainahmedmalik6759
@zainahmedmalik6759 2 жыл бұрын
Yes no doubt I am Pakistani ETO.... Love and respect for sir Leckyjake from Pakistan
@benzjang765
@benzjang765 Жыл бұрын
Nkakaproud Ka Sir Lecky Jake sa mga Filipino na nagbabarko. Isa Kang magaling na ETO.
@mariyaan1545
@mariyaan1545 2 жыл бұрын
Sir , i got a placement in Maersk line as a traine cadet of ETO ,Your videos play the vital role to improve my knowledge sir ,thank for giving ur knowledge to us . I'm very proud to say I'm going to work in same organisation.
@leckyjake
@leckyjake 2 жыл бұрын
Good luck and good to know that my videos was useful to you. Thank you so much
@engr.sohelrana2395
@engr.sohelrana2395 2 ай бұрын
Exactly. We miss him badly.
@sanjay0216
@sanjay0216 5 күн бұрын
What he died?​@@engr.sohelrana2395
@etbt1058
@etbt1058 11 ай бұрын
you are just different ,thank you for the knowledge you gave us. you just make it easy to understand. thank you again
@garethjones5179
@garethjones5179 Жыл бұрын
Hi Jake great video. Very well explained.That was a trip down memory Lane for me! I was an engineer officer cadet in 1982 and later became a HVAC engineer.
@TechOne7671
@TechOne7671 2 жыл бұрын
I helped change an evaporator in a walk in fridge today with one of our fgas techs. The gas charging operation was similar to yours but we had scales. He also had a funky ratchet spanner for the valves. As a 25 year electrician this was something different. I am doing my City and Guild’s fgas next week so I can play with the AC units at work. As always good videos. Best wishes.
@leckyjake
@leckyjake 2 жыл бұрын
Thank you and good luck to your next week's job
@noelnoel4916
@noelnoel4916 Жыл бұрын
@@leckyjake what brand of pressure manifold ur using or those connectors, send me link I need to buy Thank you
@androcadivida957
@androcadivida957 Жыл бұрын
Galing nmn po salamat sayo sir sa mga vedios mo na marami talaga mapupulot na dagdag kaalaman God bless po😇
@christianjayedubos543
@christianjayedubos543 2 жыл бұрын
wow sir, nakaka amaze ang dami mo pong alam.
@leckyjake
@leckyjake 2 жыл бұрын
salamat sa panonood
@ayeayesoe2793
@ayeayesoe2793 Жыл бұрын
Great video and thanks a lot. It will be perfect to slag and tight the gland packing while handling the valves and do leak test again before leaving.
@yashrawatantartica
@yashrawatantartica Ай бұрын
Very good job greetings from Antarctica
@hachinthaniranjana3986
@hachinthaniranjana3986 2 жыл бұрын
Thank you for the clear, easy to understand presentation.
@leckyjake
@leckyjake 2 жыл бұрын
thank you for watching
@LarrydWoodruff
@LarrydWoodruff 2 жыл бұрын
Always appreciate the refresher course! Please keep em coming friend. SF ILWU
@irishgiancarlohizole136
@irishgiancarlohizole136 2 жыл бұрын
Thanks for sharing this technique Sir.Lecky! 💯 Godbless you and safe sailing! 😇 More power on your vlogs po!
@leckyjake
@leckyjake 2 жыл бұрын
thank you for watching
@cyruscruz59
@cyruscruz59 Жыл бұрын
It's very informative for other
@benshentandog3434
@benshentandog3434 2 жыл бұрын
Always watching your videos. Keep safe 👌 Magaling ka pa sa teacher ko sa refrigeration nung college ako 😆
@leckyjake
@leckyjake 2 жыл бұрын
Thank you
@eyupakdag7362
@eyupakdag7362 2 жыл бұрын
I started to watch your videos and they are instructive sooo much. Thanks for sharing your knowledge with us.
@juliusbosquehamilton1075
@juliusbosquehamilton1075 Жыл бұрын
great video boss , wish to be like you
@jewtubetruckers
@jewtubetruckers 5 ай бұрын
Great knowledge and work appreciate it
@the.starsailor
@the.starsailor 2 жыл бұрын
Very informative! Keep Posting much more such videos.
@TG-ng2ko
@TG-ng2ko 2 жыл бұрын
Nice work thanks for this great lesson I’m learning something from your video
@allanfsecusana12
@allanfsecusana12 5 ай бұрын
Sir thank you very much for shàring your skills
@Perasperalife
@Perasperalife 6 ай бұрын
Short and sweet
@pinoymaster1067
@pinoymaster1067 Жыл бұрын
good job kabayan
@nalshokagero6371
@nalshokagero6371 Жыл бұрын
new subscriber here..astigg lupeet!
@TECHNICIANRODTV
@TECHNICIANRODTV 3 ай бұрын
Nice sir
@ОганесянДавид
@ОганесянДавид Жыл бұрын
Thank you so much for this content.
@globalgate8480
@globalgate8480 2 жыл бұрын
Very cool, enjoy your posts
@davidtwumasi2684
@davidtwumasi2684 7 ай бұрын
Thanks for sharing 🙏👍
@davidharrison6789
@davidharrison6789 6 ай бұрын
I really like what you have shared with Us kindly during charging gas was compressor running or not because I can see from low side was still zero
@rb1m426
@rb1m426 2 жыл бұрын
Present 👋 lods
@leckyjake
@leckyjake 2 жыл бұрын
salamat lods
@whodat90
@whodat90 2 жыл бұрын
Very impressive that you do both electrical and HVAC! Who is responsible for paying for this type of repair, the owner of the container, the shipper, or is it covered by the boat as the cost of doing business?
@leckyjake
@leckyjake 2 жыл бұрын
i am just being paid as per monthly salary.
@Josh-b3c
@Josh-b3c 2 жыл бұрын
I have the same question really I think he means who ends up paying for the parts and refrigerant needed when a unit goes down while at sea is it the cargo transporter or the shipper or the receiver
@ChoroTesla
@ChoroTesla 2 жыл бұрын
@@Josh-b3c i think he has to write a report for each box repaired and shiping line is going to pay for the serviced container as per report.
@allanbetana5983
@allanbetana5983 2 жыл бұрын
Bravo sir🙃
@leckyjake
@leckyjake 2 жыл бұрын
thanks
@ravisthesailor
@ravisthesailor 2 жыл бұрын
Hello sir Great job please continue to share knowledge. I have a question Do you get paid extra to maintain refeer or any repairs you carry out on reefers?
@crabbyjimmy1
@crabbyjimmy1 8 ай бұрын
Thanks Jake!
@LucasOli09__
@LucasOli09__ 6 ай бұрын
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
@geenumaxy9370
@geenumaxy9370 Жыл бұрын
excellent
@LEO-zq4rn
@LEO-zq4rn 6 ай бұрын
Smart Boi You can Join us, we need good people
@kupabella9517
@kupabella9517 7 ай бұрын
❤❤ Good job mate
@NivagSwerdna
@NivagSwerdna 2 жыл бұрын
nicely done
@leckyjake
@leckyjake 2 жыл бұрын
thanks
@josemarieantepasado5267
@josemarieantepasado5267 8 ай бұрын
Hi sir. I just have some friendly questions and observations: 1.) As you mentioned that the system is a closed one, the diminished system pressure should surely imply a leak somewhere in the system. Were you able to find it? 2.) While you did purge the air out from the yellow hose but I did not see you purging out the air from the blue and red hoses. I haven't experienced working on a refrigerator yet so it really wonders me how to purge the air out from the blue hose considering it's below or equal to atmospheric pressure unlike in air-conditioning system where low side pressure is considerably above atmospheric. Hope you could enlighten me sir. More power to your channel.
@maksym90
@maksym90 Жыл бұрын
Good video.I have 1 question,during fillng up system th red valve on manifold should be open also and we can see how is pressure growing up?it was not so clear for me.
@LC-qi5ff
@LC-qi5ff 2 жыл бұрын
Greetings. What about purging air from the red/blue hoses and the centre of the manifold? Thank you
@leckyjake
@leckyjake 2 жыл бұрын
You don't need to purge as they are always isolated. It means that below zero pressure discharge gauge (red) will keep on that position.
@leeeran1159
@leeeran1159 Жыл бұрын
hi iam a new member INDIKA
@visheshmalviya3550
@visheshmalviya3550 Жыл бұрын
How to Use the vacuum pump and take out refrigerant from the system. Can you please make a video on that also.
@AmitKumar-ic6dd
@AmitKumar-ic6dd Жыл бұрын
okay you did diffuse some air,ref to atmosphere, i have heard of recovery bottle to purge out any gas from the system. please make a video using that.
@chrisantheobaranda4578
@chrisantheobaranda4578 2 жыл бұрын
good job sir
@leckyjake
@leckyjake 2 жыл бұрын
Thank you
@bassamrajjoub9843
@bassamrajjoub9843 2 жыл бұрын
I told you brother...you are a great teacher...thank you and God bless you.
@OKAFARM
@OKAFARM 4 ай бұрын
Thanks,..
@vimalvasavivijayalakshmi8683
@vimalvasavivijayalakshmi8683 2 ай бұрын
Hi brother, I have the same reefer system. At present it is a freezer. Is it possible to change to chiller mode.
@ShailSinha-ym5xq
@ShailSinha-ym5xq Жыл бұрын
Sir , it is very impressive. I have a doubt that wen u removed the discharge side hose after filling up the refrigerant why did u make the service valve of discharge side from midseat to backseat(open) . It shud be front seated after charging
@ScottYdo
@ScottYdo Жыл бұрын
👍👍🎯
@yusuf2169
@yusuf2169 Жыл бұрын
I want to work with You're good teacher
@simpleguy5521
@simpleguy5521 6 күн бұрын
Kabayan anong problem kapareho sa unit mo carrier primeline,,Yong compressor Di makapag high seem on and off Yong high speed.tnx
@ЭлектроМеханикСудовой
@ЭлектроМеханикСудовой 2 жыл бұрын
Hello, good video for begginers, but where is scale for refrigerant bottle, this is especially need for people who is learning this. It”s good to now how many kg you get in to the system.
@leckyjake
@leckyjake 2 жыл бұрын
I always depend on the working pressure as the ship is moving from places to places, different ambient temperatures which might affect the operation of the refrigeration system.
@ЭлектроМеханикСудовой
@ЭлектроМеханикСудовой 2 жыл бұрын
@@leckyjake, yep this is also correct, for expirience people who now this. Any way thanks for videos, good job!
@Vad-tl8re
@Vad-tl8re 6 ай бұрын
​@@leckyjakehow do you know what is correct working pressure?
@benjiebajuyo9462
@benjiebajuyo9462 2 жыл бұрын
I would like to ask, during charging does the compressor is running that time?
@leckyjake
@leckyjake 2 жыл бұрын
Yes it is running
@benjiebajuyo9462
@benjiebajuyo9462 2 жыл бұрын
@@leckyjake so it means, during charging you just to wait to run the compressor before opening the manifold valve?
@mlenstra
@mlenstra 2 жыл бұрын
@@benjiebajuyo9462 since the temperature is way above the set point, the compressor is continuously running.
@benjiebajuyo9462
@benjiebajuyo9462 2 жыл бұрын
@@mlenstra yes your right thank you for the response I just realized it just now hehe.
@fredsalter1915
@fredsalter1915 2 жыл бұрын
When you connected to the low side service port, there was a lot of moisture and water droplets present. Should you have wiped off the water with a paper towel first so that water won't get into the system? Thanks, Lecky! God bless you!
@markm0000
@markm0000 Жыл бұрын
There’s always going to be a little contamination. The filter drier will take care of it.
@jopiaza2016
@jopiaza2016 Жыл бұрын
Sir, ask po ako kung ilan po ba ang normal pressure ng freon sa provisionn compressor at Ac compressor? Thanks and god bless sir.
@GSOURUSAIPRASAD
@GSOURUSAIPRASAD 11 ай бұрын
What type of leak detector has been used?
@jjkhd-dc4xl
@jjkhd-dc4xl 15 күн бұрын
What's the vacuum pump for? 🤔
@ryanbaria3421
@ryanbaria3421 3 ай бұрын
Sir, what is the probable trouble of having high pressure in compressor motor fault alarm in chiller Carrier Brand give me atleast the list of possible correction thanks...
@Jay-r6c
@Jay-r6c 4 ай бұрын
Sir yung valve po ba ng suction line fully open o half lng?salamat po sir
@boyethcodilla5214
@boyethcodilla5214 2 жыл бұрын
Sir is it normal that the suction line is theres no presure only the discharge line?or maybe only for that system we can check presure on discharge line thanks for info.
@simongipsyzai6130
@simongipsyzai6130 2 жыл бұрын
Hello sir. During charging suction and discharge valve is open? How many rotate the service valve open , fully open or just a little bit. Because I see you open the service valve just a little bit. ,Just make sure 🙏🏿 Thanks sir
@mithileshramteke3882
@mithileshramteke3882 2 жыл бұрын
Thank you sir
@joshuabarbosa4824
@joshuabarbosa4824 2 жыл бұрын
How do you know the required suction and discharged pressures of the system??
@mec6953
@mec6953 2 жыл бұрын
sir, we all know in refer system from evaporator slightly super heated vapour returns directly to compressor crankcase, not directly to the compressor suction side. from the crankcase compressor takes suction. why is that so? is it to eliminate risk of liquid refrigerant getting directly into the suction? or any other specific reasons? can you pls help?
@marineremran
@marineremran Жыл бұрын
Love u lots ❤❤❤
@leoalday3369
@leoalday3369 Жыл бұрын
Sir jake asko ko lng po new lng po sa reefer daikin alarm f603 how to fix thank you more power pagpalin po tyo ng may kapal
@leckyjake
@leckyjake Жыл бұрын
incorrect container model setting yan
@lwangajohn3257
@lwangajohn3257 2 жыл бұрын
So where did the refrigerant which was in the system disappear to before charging since you said there was no leakage ? And also when you finished charging the low side gauge was still showing zero
@leckyjake
@leckyjake 2 жыл бұрын
please take note that the container is moving from country to country, ship to ship, and port to port in which a lot of Technicians are handling them. there are some instances that they do maintenance and troubleshooting in which they might have had charge refrigerant less esp if they are in a very low ambient temperature.
@toyen1893
@toyen1893 2 жыл бұрын
Thoroughly leak check as what you’ve said on 1:37, but you didn’t show that you check the tubings on condenser, evaporator and bulkheads leading in/out the evaporator. So how is it so sure that the system has no leak at all? And how is it that the suction/low pressure side is still zero after charging? Thanks if you can be able to answer.
@leckyjake
@leckyjake 2 жыл бұрын
if i will put the whole clips then the video will take for hours. This is a moving machinery which travels all around the world, from trucks to trucks, from cities to cities, vessels to vessels and from hot area to low ambient temperature area. if the container came from a low ambient area and a service was made then there is a posibility that less refrigerant was charged but would still work since condensation on the condenser is too easy due to low ambient but once this travels to tropical countries just like malaysia, then this less freon would matter and need recharging.
@lwangajohn3257
@lwangajohn3257 2 жыл бұрын
Thanks for the explanation 👍
@tukamushabadickson6811
@tukamushabadickson6811 11 ай бұрын
Why is the suction gauge pressure reading 0 which the unit is running?
@pandidurai4560
@pandidurai4560 5 ай бұрын
Hello brother, normally the system is working in chiller Mode . I can change to freezer Mode
@pandidurai4560
@pandidurai4560 5 ай бұрын
Like if I change the temperature -18 , what I will follow?
@pandidurai4560
@pandidurai4560 5 ай бұрын
Also Another Unit ( Carrier Thinline ) Modulation valve doesn't Open Fully , like it's Open only 17 , How I resolve that problem
@jamesdavid1976
@jamesdavid1976 8 ай бұрын
Sir, clarify ko lang po, umaandar po ba ang compressor pagmagchacharge??
@jeromediaz1883
@jeromediaz1883 Жыл бұрын
anung number ng ratchet gamit mo pag open ng service vlv sir
@СергейЧабан-м8д
@СергейЧабан-м8д 2 жыл бұрын
Bravo
@mcjamescelocia1626
@mcjamescelocia1626 2 жыл бұрын
sir lecky jake solid fan here . question lang po. pag nag charge ba ng refregerant dapat ba naka andar ang compressor or naka para ang compressor.
@leckyjake
@leckyjake 2 жыл бұрын
running ang compressor
@mcjamescelocia1626
@mcjamescelocia1626 2 жыл бұрын
@@leckyjake thankyou for the prompt answer sir. So, can we do (charging refrigerant ) on our provision reefer and HVAC onboard vessel given the system is running? because the video you shared is for reefer container . And also, i am confused on one person i asked he told me he charged refrigerant na naka para ang system. Thankyou sir idol . Answer is highly appreciated po.
@leckyjake
@leckyjake 2 жыл бұрын
charging of refrigerant, for me mas ok na running ang system para hindi nabibigla yung suction side ng system dahil continous running at circulation ng refrigerant and to add up, madali siyang papasukin sa system lalo kung vapor state na yung nasa tank at sa suction ka mag connect.
@leckyjake
@leckyjake 2 жыл бұрын
same lang hvac and provision
@mcjamescelocia1626
@mcjamescelocia1626 2 жыл бұрын
@@leckyjake very well explained po sir idol, and this will add my knowledge on handling hvac onboard. . looking forward for more videos regarding wiring diagram interpretation .thankyou sir. ps. i followed you on IG
@ytkennwarr5378
@ytkennwarr5378 2 жыл бұрын
Ano kaya problem sa cv namin, as checker of reefer diko po alam kung paano ayosin pero gusto ko lang matotoo. Myproblema kasi yung reefer namin first issue ayaw mag andar ng fan on going cool kaso nasa positive 30 lang tapos dibumababa. ang set point is -25 after 5 to 10 nag heat tas defrost. Check ko yung maleplug ok naman at yung wiring at voltage ng container ok naman. Ano po kaya problema or ano dapat gawain po. Newbie lang po ako totally checker po ako sa reefee namin
@ampibrambram7747
@ampibrambram7747 Жыл бұрын
hello lucky how to become an electrician on board.?
@ronniec8370
@ronniec8370 8 ай бұрын
Diba liquid state yung nasa red connection?
@leandroandre5109
@leandroandre5109 Жыл бұрын
My friend ,coloca uma legenda em português pra nós compreendermos blz
@patricioaguayo9088
@patricioaguayo9088 Жыл бұрын
So there is no leak?
@Josh-b3c
@Josh-b3c 2 жыл бұрын
You're at a real disadvantage when checking for leaks since you can't get on the inside
@leckyjake
@leckyjake 2 жыл бұрын
especially underneath the evaporator
@mec6953
@mec6953 2 жыл бұрын
sir, since u didn't find any leakage in the system, then why refrigerant level was low? cz we all know this is a close loop system, nothing comes in and out
@leckyjake
@leckyjake 2 жыл бұрын
i cannot see any source but it could be on the last service by other tech which might mistakenly charged less refrigerant
@toyen1893
@toyen1893 2 жыл бұрын
Does it mean that at the time of your troubleshooting, the reefer container had just been loaded?
@gantlahemanthkumar4562
@gantlahemanthkumar4562 Жыл бұрын
Hi sir
@macmacsumarapnah1906
@macmacsumarapnah1906 2 жыл бұрын
Sir ask ko lng po bakit po zero ung value ng low side?
@НиколайЛарин-ш4п
@НиколайЛарин-ш4п 2 жыл бұрын
Sometimes it is better to put bottle bottom up to charge liquid refrigerant.
@leckyjake
@leckyjake 2 жыл бұрын
id rather wait for the process while charging vapor in the suction side
@Natnat_816
@Natnat_816 Жыл бұрын
Where you will charge the liquid refrigerant to the system if you want to charge the system by liquid rfrgnt. I'm asking the foreigner Sir lecky.
@arjunkumara7341
@arjunkumara7341 Жыл бұрын
Why that blue line i.e suction line was showing zero psi
@leckyjake
@leckyjake Жыл бұрын
because it it the suction line, it is normally into that range if your setpoint is deep freeze
@alvinalcasid-fm6nm
@alvinalcasid-fm6nm 3 ай бұрын
bosing paano kung ang set point is -10.0 F tapos return is 20 or 15 F kailangan ba magkarga ako ng 134a pls reply
@alvinalcasid-fm6nm
@alvinalcasid-fm6nm 3 ай бұрын
boss reply naman dyan
@Laba-Diena
@Laba-Diena 2 жыл бұрын
Condenser coil leaking :D
@leckyjake
@leckyjake 2 жыл бұрын
i can say no, because it's been a week now and unit is still running good and pressure is holding at 9.5 bar pressure
@Laba-Diena
@Laba-Diena 2 жыл бұрын
@@leckyjake i might be wrong ;) but most of these units have issues with condenser coil
@arlanalvar362
@arlanalvar362 Жыл бұрын
500 a day to sa oil&gas hehehehe
@romiecer19bhongbhong96
@romiecer19bhongbhong96 Жыл бұрын
Pinoy po ba kayu sir
@bradgeary3467
@bradgeary3467 2 жыл бұрын
what country are you from? are those charge hose fittings required by your countries laws? how do you push air from your hoses with those silly low loss fittings? hope you don’t have to pull vacuum through all that silly stuff also. we can and are made to always contain our refrigerant as techs and you here prove it’s easy to do, yet it commonly leaks from refrigerant systems with little or no regulations or punishments when it does. brand new equipment leaking its charge from day one. i’ve seen 100’s of kilos of refrigerant go freely, but it’s not made a big deal. but your using a manifold thats overly complex, expensive and burdensome i’m assuming because it’s required by your laws. let’s try building equipment that’s not junk
@mlenstra
@mlenstra 2 жыл бұрын
“Complex and burdensome” in which way(s)? This looks to me like a perfectly standard HVAC manifold set with some automotive QD fittings to connect to the service ports, which parts would you say are unnecessary?
@bradgeary3467
@bradgeary3467 2 жыл бұрын
@@mlenstra look like low loss fittings to me
@abecoulter8550
@abecoulter8550 Жыл бұрын
dont teach people how to recharge, its ONLY TO BE DONE BY PROFESSIONALS
@leckyjake
@leckyjake Жыл бұрын
Just make decisions to my life
@TopViralMiX
@TopViralMiX Жыл бұрын
how to mnow which is suction vs discharge
@TopViralMiX
@TopViralMiX Жыл бұрын
and where did you read 8.6 par
@charliejohnson5630
@charliejohnson5630 Жыл бұрын
Hi Mr Lecky please can you share your email address so I can discuss some questions I have about reefer repairs. Thank you for your good videos
BASIC REFRIGERATION SYSTEM,  HOW YOUR AIRCONDITION WORKS?
8:03
Smart Sigma Kid #funny #sigma
00:33
CRAZY GREAPA
Рет қаралды 12 МЛН
Кто круче, как думаешь?
00:44
МЯТНАЯ ФАНТА
Рет қаралды 6 МЛН
Lazy days…
00:24
Anwar Jibawi
Рет қаралды 6 МЛН
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
REF COMPRESSOR OVERLOADING TROUBLE
9:48
leckyjake
Рет қаралды 22 М.
Charging a system with liquid-HVAC Online Training and Courses
6:38
Aircon Academy
Рет қаралды 103 М.
How To Charge Gas/Refrigerant In A Refrigerator - R134A Freon
10:21
Forever Tech English
Рет қаралды 870 М.
AUTO PILOT POWER FAIL AND HOW TO READ WIRING DIAGRAM
11:52
leckyjake
Рет қаралды 40 М.
Refrigeration Charging #refrigerant #HVAC #refrigeration
3:22
marineinsight
Рет қаралды 83 М.
CHARGING REFRIGERANT R404A ON THERMO KING REEFER CONTAINER
3:49
Reefer Container PH
Рет қаралды 32 М.
Advanced Refrigeration - Charging
16:38
Christopher Molnar
Рет қаралды 86 М.