Free knowledge from a world class seafarer. I hope your channel will be discovered more. You deserve all the commendation. thank you very much for the knowledge.
@leckyjake2 жыл бұрын
Thank you very much. Comments like this is enough to keep me going.
@thuweinmassoud9062Күн бұрын
@@leckyjake we learning from you do you have a group
@antonioreyes74762 жыл бұрын
Leckyjake is a world class Filipino ETO no doubt.
@leckyjake2 жыл бұрын
Very much appreciated. Thank you for your wonderful comment
@zainahmedmalik67592 жыл бұрын
Yes no doubt I am Pakistani ETO.... Love and respect for sir Leckyjake from Pakistan
@benzjang765 Жыл бұрын
Nkakaproud Ka Sir Lecky Jake sa mga Filipino na nagbabarko. Isa Kang magaling na ETO.
@mariyaan15452 жыл бұрын
Sir , i got a placement in Maersk line as a traine cadet of ETO ,Your videos play the vital role to improve my knowledge sir ,thank for giving ur knowledge to us . I'm very proud to say I'm going to work in same organisation.
@leckyjake2 жыл бұрын
Good luck and good to know that my videos was useful to you. Thank you so much
@engr.sohelrana23952 ай бұрын
Exactly. We miss him badly.
@sanjay02165 күн бұрын
What he died?@@engr.sohelrana2395
@etbt105811 ай бұрын
you are just different ,thank you for the knowledge you gave us. you just make it easy to understand. thank you again
@garethjones5179 Жыл бұрын
Hi Jake great video. Very well explained.That was a trip down memory Lane for me! I was an engineer officer cadet in 1982 and later became a HVAC engineer.
@TechOne76712 жыл бұрын
I helped change an evaporator in a walk in fridge today with one of our fgas techs. The gas charging operation was similar to yours but we had scales. He also had a funky ratchet spanner for the valves. As a 25 year electrician this was something different. I am doing my City and Guild’s fgas next week so I can play with the AC units at work. As always good videos. Best wishes.
@leckyjake2 жыл бұрын
Thank you and good luck to your next week's job
@noelnoel4916 Жыл бұрын
@@leckyjake what brand of pressure manifold ur using or those connectors, send me link I need to buy Thank you
@androcadivida957 Жыл бұрын
Galing nmn po salamat sayo sir sa mga vedios mo na marami talaga mapupulot na dagdag kaalaman God bless po😇
@christianjayedubos5432 жыл бұрын
wow sir, nakaka amaze ang dami mo pong alam.
@leckyjake2 жыл бұрын
salamat sa panonood
@ayeayesoe2793 Жыл бұрын
Great video and thanks a lot. It will be perfect to slag and tight the gland packing while handling the valves and do leak test again before leaving.
@yashrawatantarticaАй бұрын
Very good job greetings from Antarctica
@hachinthaniranjana39862 жыл бұрын
Thank you for the clear, easy to understand presentation.
@leckyjake2 жыл бұрын
thank you for watching
@LarrydWoodruff2 жыл бұрын
Always appreciate the refresher course! Please keep em coming friend. SF ILWU
@irishgiancarlohizole1362 жыл бұрын
Thanks for sharing this technique Sir.Lecky! 💯 Godbless you and safe sailing! 😇 More power on your vlogs po!
@leckyjake2 жыл бұрын
thank you for watching
@cyruscruz59 Жыл бұрын
It's very informative for other
@benshentandog34342 жыл бұрын
Always watching your videos. Keep safe 👌 Magaling ka pa sa teacher ko sa refrigeration nung college ako 😆
@leckyjake2 жыл бұрын
Thank you
@eyupakdag73622 жыл бұрын
I started to watch your videos and they are instructive sooo much. Thanks for sharing your knowledge with us.
@juliusbosquehamilton1075 Жыл бұрын
great video boss , wish to be like you
@jewtubetruckers5 ай бұрын
Great knowledge and work appreciate it
@the.starsailor2 жыл бұрын
Very informative! Keep Posting much more such videos.
@TG-ng2ko2 жыл бұрын
Nice work thanks for this great lesson I’m learning something from your video
@allanfsecusana125 ай бұрын
Sir thank you very much for shàring your skills
@Perasperalife6 ай бұрын
Short and sweet
@pinoymaster1067 Жыл бұрын
good job kabayan
@nalshokagero6371 Жыл бұрын
new subscriber here..astigg lupeet!
@TECHNICIANRODTV3 ай бұрын
Nice sir
@ОганесянДавид Жыл бұрын
Thank you so much for this content.
@globalgate84802 жыл бұрын
Very cool, enjoy your posts
@davidtwumasi26847 ай бұрын
Thanks for sharing 🙏👍
@davidharrison67896 ай бұрын
I really like what you have shared with Us kindly during charging gas was compressor running or not because I can see from low side was still zero
@rb1m4262 жыл бұрын
Present 👋 lods
@leckyjake2 жыл бұрын
salamat lods
@whodat902 жыл бұрын
Very impressive that you do both electrical and HVAC! Who is responsible for paying for this type of repair, the owner of the container, the shipper, or is it covered by the boat as the cost of doing business?
@leckyjake2 жыл бұрын
i am just being paid as per monthly salary.
@Josh-b3c2 жыл бұрын
I have the same question really I think he means who ends up paying for the parts and refrigerant needed when a unit goes down while at sea is it the cargo transporter or the shipper or the receiver
@ChoroTesla2 жыл бұрын
@@Josh-b3c i think he has to write a report for each box repaired and shiping line is going to pay for the serviced container as per report.
@allanbetana59832 жыл бұрын
Bravo sir🙃
@leckyjake2 жыл бұрын
thanks
@ravisthesailor2 жыл бұрын
Hello sir Great job please continue to share knowledge. I have a question Do you get paid extra to maintain refeer or any repairs you carry out on reefers?
@crabbyjimmy18 ай бұрын
Thanks Jake!
@LucasOli09__6 ай бұрын
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
@geenumaxy9370 Жыл бұрын
excellent
@LEO-zq4rn6 ай бұрын
Smart Boi You can Join us, we need good people
@kupabella95177 ай бұрын
❤❤ Good job mate
@NivagSwerdna2 жыл бұрын
nicely done
@leckyjake2 жыл бұрын
thanks
@josemarieantepasado52678 ай бұрын
Hi sir. I just have some friendly questions and observations: 1.) As you mentioned that the system is a closed one, the diminished system pressure should surely imply a leak somewhere in the system. Were you able to find it? 2.) While you did purge the air out from the yellow hose but I did not see you purging out the air from the blue and red hoses. I haven't experienced working on a refrigerator yet so it really wonders me how to purge the air out from the blue hose considering it's below or equal to atmospheric pressure unlike in air-conditioning system where low side pressure is considerably above atmospheric. Hope you could enlighten me sir. More power to your channel.
@maksym90 Жыл бұрын
Good video.I have 1 question,during fillng up system th red valve on manifold should be open also and we can see how is pressure growing up?it was not so clear for me.
@LC-qi5ff2 жыл бұрын
Greetings. What about purging air from the red/blue hoses and the centre of the manifold? Thank you
@leckyjake2 жыл бұрын
You don't need to purge as they are always isolated. It means that below zero pressure discharge gauge (red) will keep on that position.
@leeeran1159 Жыл бұрын
hi iam a new member INDIKA
@visheshmalviya3550 Жыл бұрын
How to Use the vacuum pump and take out refrigerant from the system. Can you please make a video on that also.
@AmitKumar-ic6dd Жыл бұрын
okay you did diffuse some air,ref to atmosphere, i have heard of recovery bottle to purge out any gas from the system. please make a video using that.
@chrisantheobaranda45782 жыл бұрын
good job sir
@leckyjake2 жыл бұрын
Thank you
@bassamrajjoub98432 жыл бұрын
I told you brother...you are a great teacher...thank you and God bless you.
@OKAFARM4 ай бұрын
Thanks,..
@vimalvasavivijayalakshmi86832 ай бұрын
Hi brother, I have the same reefer system. At present it is a freezer. Is it possible to change to chiller mode.
@ShailSinha-ym5xq Жыл бұрын
Sir , it is very impressive. I have a doubt that wen u removed the discharge side hose after filling up the refrigerant why did u make the service valve of discharge side from midseat to backseat(open) . It shud be front seated after charging
@ScottYdo Жыл бұрын
👍👍🎯
@yusuf2169 Жыл бұрын
I want to work with You're good teacher
@simpleguy55216 күн бұрын
Kabayan anong problem kapareho sa unit mo carrier primeline,,Yong compressor Di makapag high seem on and off Yong high speed.tnx
@ЭлектроМеханикСудовой2 жыл бұрын
Hello, good video for begginers, but where is scale for refrigerant bottle, this is especially need for people who is learning this. It”s good to now how many kg you get in to the system.
@leckyjake2 жыл бұрын
I always depend on the working pressure as the ship is moving from places to places, different ambient temperatures which might affect the operation of the refrigeration system.
@ЭлектроМеханикСудовой2 жыл бұрын
@@leckyjake, yep this is also correct, for expirience people who now this. Any way thanks for videos, good job!
@Vad-tl8re6 ай бұрын
@@leckyjakehow do you know what is correct working pressure?
@benjiebajuyo94622 жыл бұрын
I would like to ask, during charging does the compressor is running that time?
@leckyjake2 жыл бұрын
Yes it is running
@benjiebajuyo94622 жыл бұрын
@@leckyjake so it means, during charging you just to wait to run the compressor before opening the manifold valve?
@mlenstra2 жыл бұрын
@@benjiebajuyo9462 since the temperature is way above the set point, the compressor is continuously running.
@benjiebajuyo94622 жыл бұрын
@@mlenstra yes your right thank you for the response I just realized it just now hehe.
@fredsalter19152 жыл бұрын
When you connected to the low side service port, there was a lot of moisture and water droplets present. Should you have wiped off the water with a paper towel first so that water won't get into the system? Thanks, Lecky! God bless you!
@markm0000 Жыл бұрын
There’s always going to be a little contamination. The filter drier will take care of it.
@jopiaza2016 Жыл бұрын
Sir, ask po ako kung ilan po ba ang normal pressure ng freon sa provisionn compressor at Ac compressor? Thanks and god bless sir.
@GSOURUSAIPRASAD11 ай бұрын
What type of leak detector has been used?
@jjkhd-dc4xl15 күн бұрын
What's the vacuum pump for? 🤔
@ryanbaria34213 ай бұрын
Sir, what is the probable trouble of having high pressure in compressor motor fault alarm in chiller Carrier Brand give me atleast the list of possible correction thanks...
@Jay-r6c4 ай бұрын
Sir yung valve po ba ng suction line fully open o half lng?salamat po sir
@boyethcodilla52142 жыл бұрын
Sir is it normal that the suction line is theres no presure only the discharge line?or maybe only for that system we can check presure on discharge line thanks for info.
@simongipsyzai61302 жыл бұрын
Hello sir. During charging suction and discharge valve is open? How many rotate the service valve open , fully open or just a little bit. Because I see you open the service valve just a little bit. ,Just make sure 🙏🏿 Thanks sir
@mithileshramteke38822 жыл бұрын
Thank you sir
@joshuabarbosa48242 жыл бұрын
How do you know the required suction and discharged pressures of the system??
@mec69532 жыл бұрын
sir, we all know in refer system from evaporator slightly super heated vapour returns directly to compressor crankcase, not directly to the compressor suction side. from the crankcase compressor takes suction. why is that so? is it to eliminate risk of liquid refrigerant getting directly into the suction? or any other specific reasons? can you pls help?
@marineremran Жыл бұрын
Love u lots ❤❤❤
@leoalday3369 Жыл бұрын
Sir jake asko ko lng po new lng po sa reefer daikin alarm f603 how to fix thank you more power pagpalin po tyo ng may kapal
@leckyjake Жыл бұрын
incorrect container model setting yan
@lwangajohn32572 жыл бұрын
So where did the refrigerant which was in the system disappear to before charging since you said there was no leakage ? And also when you finished charging the low side gauge was still showing zero
@leckyjake2 жыл бұрын
please take note that the container is moving from country to country, ship to ship, and port to port in which a lot of Technicians are handling them. there are some instances that they do maintenance and troubleshooting in which they might have had charge refrigerant less esp if they are in a very low ambient temperature.
@toyen18932 жыл бұрын
Thoroughly leak check as what you’ve said on 1:37, but you didn’t show that you check the tubings on condenser, evaporator and bulkheads leading in/out the evaporator. So how is it so sure that the system has no leak at all? And how is it that the suction/low pressure side is still zero after charging? Thanks if you can be able to answer.
@leckyjake2 жыл бұрын
if i will put the whole clips then the video will take for hours. This is a moving machinery which travels all around the world, from trucks to trucks, from cities to cities, vessels to vessels and from hot area to low ambient temperature area. if the container came from a low ambient area and a service was made then there is a posibility that less refrigerant was charged but would still work since condensation on the condenser is too easy due to low ambient but once this travels to tropical countries just like malaysia, then this less freon would matter and need recharging.
@lwangajohn32572 жыл бұрын
Thanks for the explanation 👍
@tukamushabadickson681111 ай бұрын
Why is the suction gauge pressure reading 0 which the unit is running?
@pandidurai45605 ай бұрын
Hello brother, normally the system is working in chiller Mode . I can change to freezer Mode
@pandidurai45605 ай бұрын
Like if I change the temperature -18 , what I will follow?
@pandidurai45605 ай бұрын
Also Another Unit ( Carrier Thinline ) Modulation valve doesn't Open Fully , like it's Open only 17 , How I resolve that problem
@jamesdavid19768 ай бұрын
Sir, clarify ko lang po, umaandar po ba ang compressor pagmagchacharge??
@jeromediaz1883 Жыл бұрын
anung number ng ratchet gamit mo pag open ng service vlv sir
@СергейЧабан-м8д2 жыл бұрын
Bravo
@mcjamescelocia16262 жыл бұрын
sir lecky jake solid fan here . question lang po. pag nag charge ba ng refregerant dapat ba naka andar ang compressor or naka para ang compressor.
@leckyjake2 жыл бұрын
running ang compressor
@mcjamescelocia16262 жыл бұрын
@@leckyjake thankyou for the prompt answer sir. So, can we do (charging refrigerant ) on our provision reefer and HVAC onboard vessel given the system is running? because the video you shared is for reefer container . And also, i am confused on one person i asked he told me he charged refrigerant na naka para ang system. Thankyou sir idol . Answer is highly appreciated po.
@leckyjake2 жыл бұрын
charging of refrigerant, for me mas ok na running ang system para hindi nabibigla yung suction side ng system dahil continous running at circulation ng refrigerant and to add up, madali siyang papasukin sa system lalo kung vapor state na yung nasa tank at sa suction ka mag connect.
@leckyjake2 жыл бұрын
same lang hvac and provision
@mcjamescelocia16262 жыл бұрын
@@leckyjake very well explained po sir idol, and this will add my knowledge on handling hvac onboard. . looking forward for more videos regarding wiring diagram interpretation .thankyou sir. ps. i followed you on IG
@ytkennwarr53782 жыл бұрын
Ano kaya problem sa cv namin, as checker of reefer diko po alam kung paano ayosin pero gusto ko lang matotoo. Myproblema kasi yung reefer namin first issue ayaw mag andar ng fan on going cool kaso nasa positive 30 lang tapos dibumababa. ang set point is -25 after 5 to 10 nag heat tas defrost. Check ko yung maleplug ok naman at yung wiring at voltage ng container ok naman. Ano po kaya problema or ano dapat gawain po. Newbie lang po ako totally checker po ako sa reefee namin
@ampibrambram7747 Жыл бұрын
hello lucky how to become an electrician on board.?
@ronniec83708 ай бұрын
Diba liquid state yung nasa red connection?
@leandroandre5109 Жыл бұрын
My friend ,coloca uma legenda em português pra nós compreendermos blz
@patricioaguayo9088 Жыл бұрын
So there is no leak?
@Josh-b3c2 жыл бұрын
You're at a real disadvantage when checking for leaks since you can't get on the inside
@leckyjake2 жыл бұрын
especially underneath the evaporator
@mec69532 жыл бұрын
sir, since u didn't find any leakage in the system, then why refrigerant level was low? cz we all know this is a close loop system, nothing comes in and out
@leckyjake2 жыл бұрын
i cannot see any source but it could be on the last service by other tech which might mistakenly charged less refrigerant
@toyen18932 жыл бұрын
Does it mean that at the time of your troubleshooting, the reefer container had just been loaded?
@gantlahemanthkumar4562 Жыл бұрын
Hi sir
@macmacsumarapnah19062 жыл бұрын
Sir ask ko lng po bakit po zero ung value ng low side?
@НиколайЛарин-ш4п2 жыл бұрын
Sometimes it is better to put bottle bottom up to charge liquid refrigerant.
@leckyjake2 жыл бұрын
id rather wait for the process while charging vapor in the suction side
@Natnat_816 Жыл бұрын
Where you will charge the liquid refrigerant to the system if you want to charge the system by liquid rfrgnt. I'm asking the foreigner Sir lecky.
@arjunkumara7341 Жыл бұрын
Why that blue line i.e suction line was showing zero psi
@leckyjake Жыл бұрын
because it it the suction line, it is normally into that range if your setpoint is deep freeze
@alvinalcasid-fm6nm3 ай бұрын
bosing paano kung ang set point is -10.0 F tapos return is 20 or 15 F kailangan ba magkarga ako ng 134a pls reply
@alvinalcasid-fm6nm3 ай бұрын
boss reply naman dyan
@Laba-Diena2 жыл бұрын
Condenser coil leaking :D
@leckyjake2 жыл бұрын
i can say no, because it's been a week now and unit is still running good and pressure is holding at 9.5 bar pressure
@Laba-Diena2 жыл бұрын
@@leckyjake i might be wrong ;) but most of these units have issues with condenser coil
@arlanalvar362 Жыл бұрын
500 a day to sa oil&gas hehehehe
@romiecer19bhongbhong96 Жыл бұрын
Pinoy po ba kayu sir
@bradgeary34672 жыл бұрын
what country are you from? are those charge hose fittings required by your countries laws? how do you push air from your hoses with those silly low loss fittings? hope you don’t have to pull vacuum through all that silly stuff also. we can and are made to always contain our refrigerant as techs and you here prove it’s easy to do, yet it commonly leaks from refrigerant systems with little or no regulations or punishments when it does. brand new equipment leaking its charge from day one. i’ve seen 100’s of kilos of refrigerant go freely, but it’s not made a big deal. but your using a manifold thats overly complex, expensive and burdensome i’m assuming because it’s required by your laws. let’s try building equipment that’s not junk
@mlenstra2 жыл бұрын
“Complex and burdensome” in which way(s)? This looks to me like a perfectly standard HVAC manifold set with some automotive QD fittings to connect to the service ports, which parts would you say are unnecessary?
@bradgeary34672 жыл бұрын
@@mlenstra look like low loss fittings to me
@abecoulter8550 Жыл бұрын
dont teach people how to recharge, its ONLY TO BE DONE BY PROFESSIONALS
@leckyjake Жыл бұрын
Just make decisions to my life
@TopViralMiX Жыл бұрын
how to mnow which is suction vs discharge
@TopViralMiX Жыл бұрын
and where did you read 8.6 par
@charliejohnson5630 Жыл бұрын
Hi Mr Lecky please can you share your email address so I can discuss some questions I have about reefer repairs. Thank you for your good videos