Crazy domestic consumer unit install

  Рет қаралды 31,062

Residual Electrical

Residual Electrical

Күн бұрын

Пікірлер: 155
@residualelectrical
@residualelectrical 10 ай бұрын
PART 2 OUT NOW 👇🏼 kzbin.info/www/bejne/fZO5mad8qbWFmZYsi=fPsbpehSFyRcRUKw
@vScottYx
@vScottYx 10 ай бұрын
Mike, which mascot work trousers are they? Cheers
@hackwoodelectrical
@hackwoodelectrical 10 ай бұрын
Audio seems fine really mate
@stuartthespark
@stuartthespark 10 ай бұрын
Audio is fine, but you need to sort out the lighting engineer.
@farmersteve129
@farmersteve129 10 ай бұрын
First thing to do if the fuse "falls out" is to whack in an isolator on the tails so that you can lock off in case the fuse falls back in before the DNO engineer arrives... then maybe in future the fuse is less likely to fall out again!
@residualelectrical
@residualelectrical 10 ай бұрын
Fuse upgrade, Smart meter and isolator is being fitted by the DNO real soon 👍🏼
@thedemolitionman4208
@thedemolitionman4208 10 ай бұрын
@@residualelectrical yo mate just wanted to ask as you said that the dno is changing the meter i was wondering if it could be saved as i have been looking to have one for a while and also that radio telleswitch
@jasonmart1081
@jasonmart1081 10 ай бұрын
I would have run the existing cables into a DIN rail enclosure and extended from that. Then run metal trunking from that enclosure to your new board. You could have also used singles then for the extension wires.
@callumwhitelaw4581
@callumwhitelaw4581 10 ай бұрын
My thoughts exactly
@residualelectrical
@residualelectrical 10 ай бұрын
Fair enough 👍🏼
@vScottYx
@vScottYx 10 ай бұрын
@@residualelectricalMike, which mascot trousers are they? Cheers
@residualelectrical
@residualelectrical 10 ай бұрын
They are Blaklader mate, hard to find but here is the item number: 199816449900 They are called CRAFTSMAN TROUSERS 4-WAY STRETCH X1900 but there are a lot of other pairs with similar names so it gets confusing, expensive but the best trousers I’ve ever had and lifetime warranty on the seams, NOT sponsored 👍🏼
@OldLordSpeedy
@OldLordSpeedy 10 ай бұрын
16:44 Good pre-work between trunk and CU. Very good! In Federal Republic of Germany we pre-install all things inside CU too and use up or down DIN-rail for give-over all power lines from CU to outside. This make the make-over more easy and faster work at place to make all work more easy and fast. 😊
@timalejandroalm
@timalejandroalm 10 ай бұрын
Clean install mate. Consider taking the main fuse out and putting the carrier back in, you made me nervous with the cables hanging around the open main head 😂
@residualelectrical
@residualelectrical 10 ай бұрын
I’ve got insulated cut out shrouds somewhere, but yeah he was thinking the same on the day 👍🏼
@Spiretail
@Spiretail 10 ай бұрын
who's that guy with the steady hand?
@residualelectrical
@residualelectrical 10 ай бұрын
Don’t fuel his ego 😂
@christopherkingston9601
@christopherkingston9601 9 ай бұрын
Great to see you guys showing the legend David respect.
@ForTheBirbs
@ForTheBirbs 10 ай бұрын
My favourite heatshrink is 4:1 double wall glue lined. Awesome stuff.
@Zapelectrical
@Zapelectrical 10 ай бұрын
Loved the slim packout screw organising! Might have to copy that idea and I was just thinking I’ve got enough packout stuff 😩😂
@residualelectrical
@residualelectrical 10 ай бұрын
Haha sorry mate 😂
@ninjasixrr
@ninjasixrr 10 ай бұрын
Them pesky fuses,the way they just fall out!😉👍
@residualelectrical
@residualelectrical 10 ай бұрын
😅
@RichardArblaster
@RichardArblaster 10 ай бұрын
Yeah David Savery is underrated and he's actually a very nice guy when you meet him 😎
@AGU-95
@AGU-95 10 ай бұрын
Cushty install buddy, loving the industrial/commercial look!! Only gripe, when carrying out safe isolation you need to prove before and after isolation, as you have no idea if the voltage tester has failed halfway through the procedure. Definitely worth investing in a proving unit for this.
@Mhill19
@Mhill19 10 ай бұрын
Proper spark 👌
@OldLordSpeedy
@OldLordSpeedy 10 ай бұрын
17:32 Why do you not clean the place in front of your working place first before do you make the new CU and trunking? 😮
@drewcameron6675
@drewcameron6675 10 ай бұрын
That trunking is stunning! Great work mate.
@RichardArblaster
@RichardArblaster 10 ай бұрын
11:02 was that nearly one of those "go and sit in the van" moments? 😆😆😆
@danielelise7348
@danielelise7348 10 ай бұрын
Dave Savery knows what he's doing,don't worry about that!👍
@fireykev
@fireykev 10 ай бұрын
Well caught with the mains fuse, the number of times they fall out just as your starting a job, quite spooky really 😊
@Ronny86_
@Ronny86_ 10 ай бұрын
Good job you were there when the fuse fell out! 😂
@residualelectrical
@residualelectrical 10 ай бұрын
Exactly! 😂
@black.phoenix.
@black.phoenix. 10 ай бұрын
​@@residualelectricalDamn fuses always falling from the holders, really they need to make a review in the fuse cages. 😂 But in reality very nice job. The only thing I would do different was exactly what was said by other user, who was put a Wisker Wago Consumer Relocation Unit and then from there extend all the cables. But hey your way also works, you had taken the time to heat shrink and/or protect the connectors with tape so it is still in Regs. To be honest I have to agree that it is cleaner this way, when the trunking is closed is as it never existed in the first place and all the wires were already with the size needed for this new consumer unit. Keep up the good work, waiting for part 2.
@_Miner
@_Miner 10 ай бұрын
When he said he was staving, I thought you was reaching for the dog food for him.
@residualelectrical
@residualelectrical 10 ай бұрын
😂
@g5madethetrack224
@g5madethetrack224 10 ай бұрын
These new videos are brilliant
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks man 🫡
@aidandillon9520
@aidandillon9520 10 ай бұрын
Great vid, looking forward to part 2!
@peterprice8393
@peterprice8393 10 ай бұрын
Maybe I,m just old school but would not have heat shrink the cables till they have been tested we have had some faulty splice connectors in the past.
@Spark55278
@Spark55278 10 ай бұрын
When you were extending the t+e to the board , you could have used singles, easier to work with.
@Dibbo1979
@Dibbo1979 10 ай бұрын
Great video mate. Did you not think of doing one long knock out from top to bottom of DB with paxolin between DB and trunking? Just might struggle if you want to add more circuits in future..
@residualelectrical
@residualelectrical 10 ай бұрын
I did contemplate it, but there is more than enough access to each section and a lot of the domestic boards aren’t designed to be adapted like that, you’ll see more in part 2 👍🏼
@jimbossimrigs7961
@jimbossimrigs7961 10 ай бұрын
Hey Mike, cracking job. Actually interested in how you put together the metal trunking, if you have a quick bit of footage from that it would be great for the next part (as a flashback) Great work 👍
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks, I didn’t film any of that, my bad! But I’ll make sure I do in future content 🤝🏼
@adamjwhite50
@adamjwhite50 10 ай бұрын
Mate ,coop meal deals are the best get you and your boy there
@Satters
@Satters 10 ай бұрын
Nice job, very well done, but we each have our own way of doing things, what I would do differently... Not fit AFDDs, replace cables rather than extend, fit enclosed MET, fit separate isolator between meter and DB, run trunking to the right of DB to avoid incoming tails running through outgoing trunking.
@jacobspringman
@jacobspringman 10 ай бұрын
I’m honestly surprised at how you spliced those cables. I know it’s different across the pond, but I can’t imagine electrical taping a bundle of connectors as part of a high-end installation. I thought you would have taken the existing cables into an enclosure with din rail Instead. It doesn’t look professional, and now those joints will be difficult to inspect or work on in the future, since they are in-line with no slack.
@residualelectrical
@residualelectrical 10 ай бұрын
There is no difficulty in inspecting the joints, they can be removed from the trunking due to the slack around the right angle, the tape can be removed and they can be inspected, the connections are maintenance free and they have been left double insulated. I never said it was a high end installation, I needed a quick and easy way to join the cables, this meets regs and it’s very common in the UK. An enclosure would have taken a lot more time, labelling and creates its own set of problems on an installation with this many problems already while also being incredibly disorientating for any electrician in the future.
@gwil6100
@gwil6100 10 ай бұрын
Hi Mike, I have the millwaukee heat gun aswell, it works better with the nossles that clip on to the end. :) Great work!
@residualelectrical
@residualelectrical 10 ай бұрын
Yeah those adapters are good! Thanks for tuning in 🙂
@hackwoodelectrical
@hackwoodelectrical 10 ай бұрын
Mine have disappeared 😂 have to put gloves on and use my hand to like funnel the heat 😅
@ryanoshaughnessy1844
@ryanoshaughnessy1844 10 ай бұрын
Class job Mike keep up the good work. Really tidy work I’m electrician myself
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks buddy 🤝🏼
@almerdiahmed3160
@almerdiahmed3160 10 ай бұрын
Thanks brother 🙏 💙
@Nihilumbra
@Nihilumbra 8 ай бұрын
Привет друг, подскажи, что это за коннекторы, которыми ты соеденял кабеля для удлинения? Спасибо 😉
@TM-kf1nz
@TM-kf1nz 10 ай бұрын
Turning a shitty domestic install into a industrial style masterpiece👌
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks mate
@landroverlandyman
@landroverlandyman 10 ай бұрын
The tool in question is for levelling up a grinding wheel. You hold the spinny wheel up against the spinny grinding wheel for a true flat surface. 👍
@landroverlandyman
@landroverlandyman 10 ай бұрын
Sorry on the next video not this one . My bad
@syoufass3043
@syoufass3043 10 ай бұрын
A very nice system and a great job too ❤❤
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks!
@pinmast0r
@pinmast0r 9 ай бұрын
I was just about to say check Dave Savery for the AFDD tester and as I was typing this you mentioned him anyway :)
@billsbasementworkshop1902
@billsbasementworkshop1902 10 ай бұрын
Hi Mike, Just a thought, but don't you think that doing a Van Tour is letting anyone who wants to break into your van, know what is worth stealing?
@residualelectrical
@residualelectrical 10 ай бұрын
It’s a very good point, nothing is kept in the van overnight, and it’s all tracked and insured, I’ll have to weight up if the video is worth it I guess 👍🏼
@truthwillout7909
@truthwillout7909 10 ай бұрын
Excellent video and a good install. Keep it up.
@matt4436
@matt4436 10 ай бұрын
Which connectors are you using in 26:30 ?
@pinmast0r
@pinmast0r 9 ай бұрын
I promise last question :) What derating factor was used (if any) for the cable grouping in the trunking?
@residualelectrical
@residualelectrical 9 ай бұрын
Nah I personally wouldn’t apply a de-rating factor, for 10+ cables contained in trunking “spaded” like they are it would be 0.90, which is nothing, but that is based on them being contained in trunking for 100% if their run, not 1% of their run, it’s the same reason why you wouldn’t apply it for cables within a board. There are unique exemptions but for this small domestic install we don’t need to worry 👍🏼 No problems with the questions, keep em coming!
@pinmast0r
@pinmast0r 9 ай бұрын
Thanks for taking the time to reply, I'm always learning and I much appreciate it!
@pinmast0r
@pinmast0r 9 ай бұрын
Genuine question - why did you not use a maintenance free extension box?
@residualelectrical
@residualelectrical 9 ай бұрын
Because this was quicker and simpler and the whole place is going to be re-wired eventually 👍🏼
@pinmast0r
@pinmast0r 9 ай бұрын
Fair play. I love the mix of domestic and commercial in this install. Might be a tad ott but I kinda like that for who's place it is.
@michaelscott3401
@michaelscott3401 10 ай бұрын
Hello MIKE you could have used two inch bushes and galv couplings even more room to work with why struggle thats what i say otherwise a good quality install well done that man.
@residualelectrical
@residualelectrical 10 ай бұрын
To be honest the holes in the DB where knockouts, as I didn’t need them to be any wider I just used what was there 👍🏼
@johnburns4017
@johnburns4017 10 ай бұрын
Convert the earth to TT as an earth rod was fitted.
@residualelectrical
@residualelectrical 9 ай бұрын
Nah, going to use it a a supplementary electrode as recommended by BS7671 👍🏼
@stuartthespark
@stuartthespark 10 ай бұрын
A well planned and executed installation. I still find it odd seeing metal trunking in domestic jobs, it makes perfect sense when you have a metal board. When that pesky fuse falls out, I use a piece of gaffa tape over the exposed hole. I also kept forgetting my ear defenders, so I purchased the type you roll and put into the ear. I have packs in most of the tool kits and screw kits. I wonder if they will make a din rail mounted Guardian. The job is certainly future proofed.
@chubbychubs4636
@chubbychubs4636 16 күн бұрын
I prefer it how it was before 😊
@ForTheBirbs
@ForTheBirbs 10 ай бұрын
Collab time with Davo Savo and edumicate Callum. Lol. Love the banter
@sergiofernandez3725
@sergiofernandez3725 10 ай бұрын
Nice work Mike. A collaboration video with Davo Savo to test the AFDDs would be mint. You might have to edit out some swearing
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks buddy, maybe I’ll see if Savo is up for it!
@sbmorris2k6
@sbmorris2k6 10 ай бұрын
If you have a rod with a pme would you still put a separate rod for any outbuildings with metallic services or export from house?
@residualelectrical
@residualelectrical 10 ай бұрын
Yeah mate, Haven’t fact checked but I would assume the same rules for exporting PME apply as you would have the same potential difference possibilty at the outbuilding. PME is just a Rod at every joint, transformer etc upstream of the supply so the supplementary rod doesn’t change that, it’s just a fail safe and future proof 👍🏼
@sbmorris2k6
@sbmorris2k6 10 ай бұрын
@residualcurrent cheers bud 👍
@Watsy
@Watsy 9 ай бұрын
what happened to loadout?
@therookieca
@therookieca 10 ай бұрын
Techies? Teckys? it looks like self drilling or self tapping screws.
@residualelectrical
@residualelectrical 10 ай бұрын
Yeah, they are also known as tek screws 👍🏼
@amfcontractors
@amfcontractors 10 ай бұрын
Good work man. What camera do you use/recommend?
@residualelectrical
@residualelectrical 10 ай бұрын
I use a Sony A7C, but i got it a few years ago now, if i was buying today for that money it would probably be a Sony ZV-E1 👍🏼
@amfcontractors
@amfcontractors 10 ай бұрын
@@residualelectrical bit steep! Maybe some point this year hopefully. Thanks
@residualelectrical
@residualelectrical 10 ай бұрын
Yeah they are, they aren’t easy to use either!
@DanielCraigie
@DanielCraigie 10 ай бұрын
Hi Mike, what music did you use over the time-lapse?
@residualelectrical
@residualelectrical 10 ай бұрын
Tongue Tied by T-Shirts & Sweats 🤝🏼
@tonywebb9909
@tonywebb9909 10 ай бұрын
Nice job Mike, I might have used singles after splitting the cables, that earth sleeve looks like a pain
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks buddy, yeah if I had it I would have used it, had plenty of T&E handy that’s the only reason why it was used.
@rondo122
@rondo122 10 ай бұрын
great video!
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks rondo!
@jimmy00007
@jimmy00007 10 ай бұрын
WHAT WAS YOUR INSTALLATION PRICE
@residualelectrical
@residualelectrical 10 ай бұрын
FREE (Its my parents house)
@jimmy00007
@jimmy00007 10 ай бұрын
@@residualelectrical COOL HOW MUCH WOULD YOU CHARGE FOR ONE CONSUMER UNIT INSTALLION 10 WAY BOARD
@marcusgibbons4627
@marcusgibbons4627 10 ай бұрын
Great job Mike. Loving the videos.
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks bro!
@max246
@max246 10 ай бұрын
What are the extension connectors?
@Ragnar8504
@Ragnar8504 10 ай бұрын
Ideal Spliceline
@BB-iu7rx
@BB-iu7rx 10 ай бұрын
Why this is insane? For us in germany is this a smal size
@ErenPlaysNsh1t
@ErenPlaysNsh1t 10 ай бұрын
We only use on average 3 circuits for our sockets in an household, our appliances are fused at the plug itself which results in far less copper being used and frees up a lot of space in the fusebox rather than the rest of Europe who fuses their plug outlets at the fusebox.
@residualelectrical
@residualelectrical 10 ай бұрын
I’ve never seen a domestic board like this in the UK, the trunking, the board, the supplementary electrode, AFDD’s.. but tbh it’s just a video title.
@YENDORCARLOS
@YENDORCARLOS 10 ай бұрын
would like to know about that watch !
@residualelectrical
@residualelectrical 10 ай бұрын
Apple Watch Ultra 2 - I’m a bit of a geek but there are are few things with my watch, phone and headphones that really help on site, might do a video on it 👍🏼
@YENDORCARLOS
@YENDORCARLOS 10 ай бұрын
@@residualelectrical the noise exposure app or is it just that phone ?
@svdleer
@svdleer 10 ай бұрын
@@YENDORCARLOS it's default enabled on the Apple Watches.
@leexgx
@leexgx 10 ай бұрын
They be so sad when they lose Economy 7 (unless they are keeping the storage heaters)
@residualelectrical
@residualelectrical 10 ай бұрын
They never had storage heaters, they where removed long before they moved in which was 25 years ago now 👍🏼
@williamlowther7051
@williamlowther7051 10 ай бұрын
3x 25 mm bushes to each db, why oh why
@residualelectrical
@residualelectrical 10 ай бұрын
2 x 32mm Bushes to each section of the DB, 6 in total - because that's the prefabricated knock outs on the DB and that's all your going to need...
@ForTheBirbs
@ForTheBirbs 10 ай бұрын
Hmmmm, Callum's comments on his chances with the 600 female viewers reminds me of a mate who had two girfriends who split from him and changed "teams" .... Nice video BTW
@dorianwylie9000
@dorianwylie9000 10 ай бұрын
yea man, those DNO fuses are like some women i know.....its hard to keep it in 🤣🤣
@Hiccup77
@Hiccup77 10 ай бұрын
Argh mate, that is as rough AF. seeing this really makes we want to change my profession. I get extending cables, but crappy inline push fits and gaffer tape. Looks like some demented plasterer did the wiring. And you charge people for that?
@residualelectrical
@residualelectrical 10 ай бұрын
Yeah mate charged them £5000 for all this what’s wrong with it
@hackwoodelectrical
@hackwoodelectrical 10 ай бұрын
Yeah man that heat shrink gaffa tape is wild…
@callumwhitelaw4581
@callumwhitelaw4581 10 ай бұрын
It’s my understanding your not allowed to make joints in trunking,you have to box it. I would have just put a big galv joint box in where the cables come through the wall and tubed it or trunked it from there
@AGRElectrics
@AGRElectrics 10 ай бұрын
Joints have to be in an enclosure and accessible or maintenance free so trunking is perfectly acceptable
@residualelectrical
@residualelectrical 10 ай бұрын
Not true, but yeah I could of fitted a dedicated junction box, regardless it’s far better than I found it 👍🏼
@HarryTheSparks
@HarryTheSparks 10 ай бұрын
great video mike. 👍 if this was pvc trunking joints inside the trunking wouldn't be allowed as you can remove the lid without a tool as I see it from the regs
@AGRElectrics
@AGRElectrics 10 ай бұрын
@@HarryTheSparks the way he has done it in the video with non maintained connectors and heat shrink technically doesn't need anything as double insulation has been achieved with the heat shrink. The trunking plastic or metal additional protection. 👍
@HarryTheSparks
@HarryTheSparks 10 ай бұрын
@@AGRElectrics 👍🏼
@Subgunman
@Subgunman 10 ай бұрын
So that watch basically tells you that you are going deaf? Now knowing how much noise is created by a hammer drill and comparing it to Death Metal music, those listening to that music are basically brain dead. I would add several layers of gaffers tape or otherwise known as duct tape to the inside curve of the wire trunking just as an extra layer of insulation to keep the wires from chafing even though it might be smooth.
@Walktheline1991
@Walktheline1991 8 ай бұрын
Is your dad a spark?
@anthonybragg
@anthonybragg 10 ай бұрын
Mike, is your mate using your channel to appeal to the ladies (or men) for a date?😊😊
@residualelectrical
@residualelectrical 10 ай бұрын
He certainly is 😂
@svdleer
@svdleer 10 ай бұрын
@@residualelectrical With the first lunch review video in the car i thought Callum was longer then you, but in this video you seem longer.
@pinmast0r
@pinmast0r 9 ай бұрын
I know I know, but you should be showing people proper safe isolation and proving that tester on a known power source :) It's ok, I'll p**s off myself :)
@residualelectrical
@residualelectrical 9 ай бұрын
Sure, I’ve shown it so many times, and I have tutorials on it, I always try to show the full proper process but ultimately everyone is responsible for their own health and safety, not me 👍🏼
@HeathenGeek
@HeathenGeek 10 ай бұрын
14:38 ". . .some guy" You David Fking Savery of David Savery Electrical Services (p.b.u.h.)? Lord god of Stella and homebrew? I don't know, apprentices these days 🙄🙄 Also, "sit in the van" is that code for 'shagged senseless for breaking his screwdriver'? 🤣
@rogerbean393
@rogerbean393 10 ай бұрын
What is “insane “ about this
@residualelectrical
@residualelectrical 10 ай бұрын
In my 10 years as an electrician I have never seen a domestic consumer unit to this spec.. 36 way, double pole AFDDs, SPD, Metal trunking, Supplementary earth electrode, it’s a crazy set up for a UK bungalow, so when I come to choosing a engaging KZbin title “insane” is not that far fetched..
@MDaff-v2s
@MDaff-v2s 10 ай бұрын
Main CPC in different hole mmmmm. Tbh that looks like a pretty rough way of doing the job. Stuffing glands .....round cables really. They make flat cable glands. Bends also too tight. Sparks ain't what they used to be.
@residualelectrical
@residualelectrical 10 ай бұрын
😂😂😂 - Nothing wrong with the main Earth going through a separate hole - Wiska “winserts” where used on the glands to adapt them for T&E - What bends are too tight? The T&E? The Flexi Tails? Your mad mate I don’t need my electrical ability validated online, I just enjoy my job and enjoy making videos, nice try though 🙂
@MDaff-v2s
@MDaff-v2s 10 ай бұрын
🤣🤣🤣🥔
@residualelectrical
@residualelectrical 10 ай бұрын
And yet here you are in my comments 🤷🏼‍♂️🥔
@nealecarroll8405
@nealecarroll8405 10 ай бұрын
@@MDaff-v2s - clown !
@jessiepooch
@jessiepooch 10 ай бұрын
@user Clown.
@protectiongeek
@protectiongeek 10 ай бұрын
Sorry, as a former DNO electrical engineer with over 30 years' experience working with craftsmen of all disciplines, including highly skilled electricians, this just left me shaking my head! Inline joints wrapped in PVC tape in trunking? Seriously?! Also, why not populate your 'insane' distribution board and do as much installation and testing on it BEFORE even disconnecting the supply and disturbing the existing wiring?
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks for the insight into your expertise, how would you joint the cables? They are in an enclosure that can only be accessed with a tool, with some of the best in-line maintenance free joints in the industry, and double insulated via tape or heat shrink. In the video i mentioned that I could’ve used a junction box, this would require more labelling, more prep and more downtime, while also being one of the most disorientating methods for future electricians. I could have populated the board before hand, in many situation’s that’s the obvious move.. as mentioned I didn’t have all of the parts to build the board and it wouldn’t have made for a very interesting video.
Double stack Easy9 fuse board second fix
26:41
Residual Electrical
Рет қаралды 21 М.
Shocking Fuseboards! Electrical Nightmares Exposed 🚨⚡️
59:40
AdamDunlopElectrical
Рет қаралды 10 М.
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 15 МЛН
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 27 МЛН
路飞做的坏事被拆穿了 #路飞#海贼王
00:41
路飞与唐舞桐
Рет қаралды 25 МЛН
ESSENTIAL Tools For Electricians And EV Installers
24:33
SOTA Electrical
Рет қаралды 10 М.
Upgrading a football stadiums electricity supply
51:13
Residual Electrical
Рет қаралды 48 М.
Glanding a 630A 3 phase supply | REC09
25:46
Residual Electrical
Рет қаралды 111 М.
Trying To Reinstate Old Victorian Lantern Wiring + Removing New Work
16:15
N Bundy Electrical
Рет қаралды 19 М.
Your Garage Lights Suck - Do This Now 🫵
24:30
Artisan Electrics
Рет қаралды 117 М.
Messed Up On The Isolators
15:12
N Bundy Electrical
Рет қаралды 14 М.
Retrofitting 3 phase RCBO's - Schneider Acti9 Vigi Unit's
33:34
Residual Electrical
Рет қаралды 19 М.
I worked a day with a pro LV cable jointer
27:22
Residual Electrical
Рет қаралды 73 М.
COMPLICATED Farm Solar Install - 3 buildings, 1 Barn
35:25
Cory Mac - ØY Electrical
Рет қаралды 39 М.
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН