Review of BULVACK 300 Amp Circuit Breaker with Manual Reset | WattHour

  Рет қаралды 27,744

WattHour

WattHour

Күн бұрын

Пікірлер: 65
@JessedeVries
@JessedeVries 2 жыл бұрын
Wish I’d seen this before wasting my money on several of these cheap things. All ended up in the bin after failure of the contacts at much lower currents than rated.
@ClassicClay104
@ClassicClay104 Ай бұрын
Thanks for the video. Have been looking at these for a go box build but now I think I'll stick to standard fuses. These things look cool tho!
@zx10rmac84
@zx10rmac84 Жыл бұрын
Been known to fail, avoid with all costs 👌🇬🇧
@peterdkay
@peterdkay 2 жыл бұрын
Good review. Obviously any breaking current above 50A should not be used. Its rated up to 48V. DC breaker is more difficult as it can arc and destroy breaker Can it reliably break 48VDC and 50A? Also what is section in last minute?
@WattHour
@WattHour 2 жыл бұрын
thank you for the comment in here and in the other read breaker switch. I just changed the video with showing inside the switch.
@seeking70
@seeking70 9 ай бұрын
Other testers have determined that all of these with the 1/4 " studs are closer to 60 or 70 amps than whatever they are marked for.
@laurentsosson1739
@laurentsosson1739 3 ай бұрын
Hello and congratulations for the tests with the fuse I would like to ask you something I have a large LFP battery pack (EVE 280K) in 9S 4P or 28 volts 1120AH and my voltage converter is 4000 watts to 28 volts which fuse do you recommend between the + of the converter? 150A? fuse like yours or a fixed fuse like VICTRON? THANKS laurent
@WattHour
@WattHour 3 ай бұрын
Hello, your load is 4kW and 150A fuse is excellent choice, I chacked the VICTRON, they are very expensive. If you can't find a resettable fuese or breaker, then yes.
@ginnescamper7421
@ginnescamper7421 2 ай бұрын
Conclusion: complete garbage, like any other similar fuse.
@larrymiller5171
@larrymiller5171 Жыл бұрын
Junk
@WattHour
@WattHour Жыл бұрын
Which one the video or the product?
@mitch3424
@mitch3424 Жыл бұрын
Just fuse it 😉 these are not to be trusted
@steveschwartz9421
@steveschwartz9421 Жыл бұрын
Fuse quallity is another issue too . Buy better breakers. I've use the $20 ons and the $80 units, I'll never buy the cheapo's again!
@billharris6886
@billharris6886 5 ай бұрын
I have done extensive testing on this marine style of Chinese thermal circuit breaker. There are no specs associated with these parts, they just simply have a current stamped on them and, of the ones I have opened up, all use the same small 50 amp or so contacts. It appears none of these breakers are calibrated. I began measuring the resistance of each breaker using a calibrated 20 amp DC current. If you know the breaker resistance, you can calculate the trip point. If the breaker is dissipating 2 watts, it will trip in 1 to 10 minutes. Using the resistance method, I labeled each breaker according to it's actual trip point. My testing indicates these breakers are good for up to 24 Vdc and 35 amps. Also, since this is a thermal breaker, the trip point is noticably affected by the ambient temperature and the wire temperature. Most all circuit breakers are not rated for surge current, you can't use the breaker for instance, to switch power from the battery to the power inverter, the large capacitor bank in the inverter will quickly ruin the breaker contacts. Before closing the breaker, an incandescent light bulb must be temporarily connected across the circuit breaker to charge the capacitor bank.
@WattHour
@WattHour 5 ай бұрын
Thank you for sharing your experience.
@solardiyhobbyandrevies8118
@solardiyhobbyandrevies8118 Жыл бұрын
Does it really matter if load and line(battery) are hooked up backwards??
@Dan-LS
@Dan-LS 2 жыл бұрын
Isn't supposed to break the current over 300Ah? 🤔🙄😁
@WattHour
@WattHour 2 жыл бұрын
that's exactly I am doing the test for. The sellers just put a number. If you check Amazon, the same items with exact shape and size is soled and labeled from 50A to 300A. I will test them and people would decide which one is good for what application.
@Dan-LS
@Dan-LS 2 жыл бұрын
@@WattHour yes, very good! I have heard bad things about this breakers before. Best is to use a fuse instead, Or use a quality breaker, but that's several times higher price.
@camposvazquez
@camposvazquez Жыл бұрын
@@WattHour I apologize if I missed any updates.. I planned on using the blue sea version of these breakers...have you tested any?
@Thingamajigs
@Thingamajigs 3 ай бұрын
very dangerous. shouldn't be sold, and the only place they deserve is the bin. use something like that in your systems at your own peril.
@wesnelson7751
@wesnelson7751 29 күн бұрын
Thanks. You saved me wasting my time buying, which I was planning
@BVN-TEXAS
@BVN-TEXAS 2 ай бұрын
Buy the from a good company like blue seas system and keep them out of the elements or high heat like under the hood.😊
@nielsdaemen
@nielsdaemen 4 ай бұрын
Thanks for testing it. It's really bad and unsafe!
@yannistsopelas7217
@yannistsopelas7217 11 ай бұрын
Thank you for the video - useful to know this is not designed for the current it's advertised. Does it matter if you connect it backwards i.e. the battery on the side you connected the load and the load where you are supposed to connect the battery? Thanks
@danrascal4045
@danrascal4045 Жыл бұрын
Thank you for the video! This might have saved me lot of time. I was planning on using one of these in a new system. Probably shouldn't.
@nathanwest2304
@nathanwest2304 Жыл бұрын
so basically, it can handle 300 peak and then a fraction of that like, the rating is for inrush current and then oparting current is only 10-15 percent?
@WattHour
@WattHour Жыл бұрын
Correct. I have made a remarks at the end of video if you watch it fully.
@johncoops6897
@johncoops6897 2 жыл бұрын
Did you perform long-term test if it could really handle a continuous 50A load? You didn't mention the results in the video, only that 60A was "over the edge" for it. ... Did you want to add Amazon links to the 4 Gauge cables, as mentioned at 3:44 ?? Also maybe add links to Thermal Camera mentioned at 13:44
@WattHour
@WattHour 2 жыл бұрын
Hi, no did not do further test because the thermal image shown the device was not heating up. so it meant it was able to handle 60A current and not heating up. That's why for safety I said 50A and for hotter environments I reduced 10A which is would be sufficient. But to be sure we should always rely on the manufacturer information. for the links, I just add them. Thank you for letting me know.
@peterb2272
@peterb2272 3 ай бұрын
I had the same problem. I had a battery charger current limited to 50A and fitted one of these rated to 60A to protect from shorts. It kept breaking every few seconds. They work great.....as a switch. As a fuse they are utter rubbish
@coldrider3517
@coldrider3517 7 ай бұрын
Thank You for the info , I am looking for 125A DC breaker for my ebike project , i want something that will work as it should . Can you recommend one or two thanks , best reagards
@hornet224
@hornet224 5 ай бұрын
If the trip lever does not flip open when 100A trips then as an indicator it does not work for me.
@irfansensoy5901
@irfansensoy5901 6 ай бұрын
This fuse should not normally blow below the value written on it. In this way, it will not be of any use if the pulse duration is prolonged at low current. The important thing is that if the current is drawn above the fuse value, it will trip, right?
@jimhanty8149
@jimhanty8149 Жыл бұрын
I don’t want anything in my electrical system thats pumping hundreds of Amps that’s critical to safty that cost 20 bucks… give me a class T fuse so I can sleep well
@trebushett2079
@trebushett2079 2 жыл бұрын
YOU NEED TO BUY SOME SPANNERS!
@WattHour
@WattHour 2 жыл бұрын
I had to check the dictionary to learn what spanner is. Thanks I will buy them.
@UK100Adam
@UK100Adam Жыл бұрын
Thanks for the video. If you have contact resistance at the terminal - even as low as 1mR, it will generate a lot of heat that will conduct in to the switch and affect the switch's performance. I believe they recommend carbon of silver paste and a lot of torque to minimise contact resistance at the terminal.
@commonsense4207
@commonsense4207 Жыл бұрын
That is Trash
@honumoorea873
@honumoorea873 2 жыл бұрын
They are very bad.... Do not buy
@WattHour
@WattHour 2 жыл бұрын
Are selling similar item?
@WizzRacing
@WizzRacing Жыл бұрын
Just buy an ABB breaker and be done with it....
@MOZARTF
@MOZARTF 2 жыл бұрын
Congrats on the product review. Curious about what electronic load was used for the tests?
@gchsbus
@gchsbus Жыл бұрын
Deez Nuts... hahahaha! I see what he did there in the video.
@igornedashkivskyi1472
@igornedashkivskyi1472 Жыл бұрын
Доброго дня, дякую за огляд! Скажіть будь-ласка, яке падіння (втрата) потужності на самому вимикачі при номінальному струмі у 200ампер, чи робили ви такий замір?
@WattHour
@WattHour Жыл бұрын
I did not measure it as it can’t handle 200A continuously. It is almost zero for the value that this device can handle. I have shown thermal images and it is cool so no waste and no voltage drop across it. See video again.
@igornedashkivskyi1472
@igornedashkivskyi1472 Жыл бұрын
@@WattHour it's value important i think, because for usual 250A handle load breakers this power losses could be about 15W in 1-pole
@nomadrninet6601
@nomadrninet6601 Жыл бұрын
Awesome video! Thank you
@WattHour
@WattHour Жыл бұрын
My pleasure!
@rOSScOGITANS
@rOSScOGITANS Жыл бұрын
very nice ed important test
@arnobvlogs2862
@arnobvlogs2862 2 жыл бұрын
Hay bro long time ⌚😝
@boscodog4358
@boscodog4358 Жыл бұрын
Is that a 300amp breaker??
@WattHour
@WattHour Жыл бұрын
that's exactly why I made this video to find the answer to it.
@nightstringers
@nightstringers 2 жыл бұрын
Did it get really hot?
@WattHour
@WattHour 2 жыл бұрын
I believe I have shown the thermal image showing temperature.
@bennibenni1700
@bennibenni1700 Жыл бұрын
I installed a very similar one. Black and red instead of black and yellow. I 9.5 kW photovoltaic on the roof. 120 amps are no problem with mine, even for hours. I am lucky
@WattHour
@WattHour Жыл бұрын
wow. indeed you are. if I do battery tests, will it be interesting?
@blacklisted4885
@blacklisted4885 5 ай бұрын
$5 on Alie*press
@Jennifer-007
@Jennifer-007 Жыл бұрын
You're joking right? Even if it did handle 300 amps, you're telling me you're ok with SOLDERING that lug on? How to tell your audience you're clueless without telling your audience your clueless (or you're a fire insurance salesman, one of the two).
@WattHour
@WattHour Жыл бұрын
this happens when you don't watch all the tests. I have shown it that it can handl less than 100A contineously. Watch without skipping. it can't even handle 150A for more then 30 seconds.
@Jennifer-007
@Jennifer-007 Жыл бұрын
I LOVE the use of no name Dollar Store/Family Dollar vice grips to tighten the nut, class act my friend, class act.
@WattHour
@WattHour Жыл бұрын
Now I am clueless about "class act". ineed.
Breakers AC, DC & AC/DC - Solar Safety Part 2 - 12v Solar Shed
12:45
Testing 100A Fuses with 100A of current.
9:23
SolarEngineering
Рет қаралды 99 М.
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 21 МЛН
when you have plan B 😂
00:11
Andrey Grechka
Рет қаралды 67 МЛН
哈莉奎因怎么变骷髅了#小丑 #shorts
00:19
好人小丑
Рет қаралды 53 МЛН
Breakers vs. Fuses in the Heat // DC-DC Charging System Update
17:12
Cheap High Amp DC Breakers are they safe?  Let's find out!
5:04
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,5 МЛН
One Circuit Breaker To Rule Them All!
20:18
DavidPoz
Рет қаралды 164 М.
Inside a 125A DC circuit breaker.  Unexpected arc quenching feature.
10:19