My hot water suddenly turned off tonight and the instructions in video did the trick. Thanks so much for showing how to fix it, I owe you a beer.
@cfldriven2 жыл бұрын
Micah, congrats on fixing the problem. You may want to schedule an annual filter check on your phone. Also don't forget about flushing the system. kzbin.info/www/bejne/oIKaimmrn6uVjck
@believeinjesus8300 Жыл бұрын
My filter was striped on the out side and striped in the middle. Someone tightened way to tight. I bought “The Tankless Tool” and it absolutely worked. I was able to loosen and replace my filter.
@alexnb1853 жыл бұрын
Helpful video! This fixed my P1 error code. Note that this video does not show the user bleeding the pressure from the line. When I did this I got a rush of water coming out of the filter as the system depressurized. I'd recommend you turn off the cold and hot, and then use the pressure release above the hot water valve. Grab a bucket just in-case you still have some pressure built-up in the machine.
@cfldriven3 жыл бұрын
Thank you for mentioning that, another way to depressurize is to open hot water faucet after shutting off the cold water service valve to the tankless and prior to closing off the hot service valve. Thanks for the feedback.
@FernandoMessiasXavier Жыл бұрын
This was an exact replacement for the old one that lasted about 10 years. kzbin.infoUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).
@cfldriven Жыл бұрын
An obstructed water filter can certainly slow down and even stop the flow of water. Glad to hear the wait is over, thank you for watching.
@Julie-px7xp2 жыл бұрын
thank you so much!! our heater was not working at all. we have well water and the filter was pretty dirty. This helped immediately
@cfldriven2 жыл бұрын
If you are frequently getting lots of settlement in the filter you may want to consider larger filter before the tankless. Good to hear this video helped out, thanks for sharing and the feedback.
@CigarNZ12 жыл бұрын
Awesome, thank you!!! We had water issues due to our main filter breaking down, but replacing the filter didn't fix the hot water pressure. I figured there had to be a filter somewhere on the heater unit, you saved me calling the plumber on a Sunday :)
@cfldriven2 жыл бұрын
You have a plumber that will come out on a Sunday! Not in my area. Good to hear the video saved you a service call. Thank you for watching.
@timirving91172 ай бұрын
I've used this excellent video several times to clean my filter. I always have the same problem: I take the filter to the kitchen sink and turn on the cold water to clean the filter. When I get back to the heater, lots of water has drained onto the floor. What am I doing wrong? TIA
@cfldriven2 ай бұрын
Is it only cold water are is the mixing valve in the middle allowing cold water to back feed into tankless? Also when removing the filter residual water in the tank will leak out. I wrap a towel to prevent a mess.
@timirving91172 ай бұрын
@@cfldriven First, besides thanks for the excellent and lucid videos, thanks for your very prompt replies. So prompt that I couldn't reply until the next day! It seems it must be cold water residual in the heater that is leaking. Both the cold intake and hot outlet are closed. And there's a lot of it. I think about a quart judging from the mess on the floor. I'm going to try to buy a cap for it.
@cfldriven2 ай бұрын
@@timirving9117 There is a fair amount of plumbing for the heat exchanger and what I do after flushing the system, I leave the outflow going into the pail open. Then crack open the filter to vent the line. You will still get some water coming from the filter port but less so. Hope this helps.
@timirving91172 жыл бұрын
Excellent video with very clear instructions. A model for other instructional videos. Question: I have a RUTGH-95DVLN-2 model. Instruction manual says to drain the heater after shutting cold intake off. Is that not necessary? Thanks.
@cfldriven2 жыл бұрын
When removing water filter the water in the unit will pour out so it can get a little messy if you don't drain it first. If you have enough towels you can do it without draining. Hope this helps. Thanks for watching.
@timirving91172 жыл бұрын
@@cfldriven In video at 24 seconds in, there is a brass colored cap with a black strap and yellow tag near the blue cold water shut off valve. What is that? On my unit there is a blue shut of valve on that. My cold valve is just below where yours is, and it has a yellow handle. ??? Thanks for all your help.
@cfldriven2 жыл бұрын
@@timirving9117 That is the service port, also one on the hot water side, they are used to flush the system of minerals and deposits. This video kzbin.info/www/bejne/iaWWaXZ8nc6Uf5I will show you the process on my first Rheem. As to the yellow handle, I guess they were out of red as that tends to be the proper color for hot water, but yellow will do.
@peterholmes20892 жыл бұрын
I've had my heater for about 6 years and only just learned about this. However, I unscrewed the black plug and the filter mesh part is stuck inside. It spins around freely, but I just cant get it to come out. If I use force it will probably break the plastic surround part. Any ideas?
@cfldriven2 жыл бұрын
The plug and filter are meant to be together. Just clean the filter screen and reinstall into unit.
@davec61102 жыл бұрын
Sometime the filter screen can come off the plug. The filter screen should be able to gently tugged out with a plastic hook and it will clip back onto the plug before you reinstall.
@staceyparrott6185 Жыл бұрын
What is the fitting called that the filter screws into? I can find the filter but I can not find that fitting it seats into. Thanks!
@cfldriven Жыл бұрын
It is called Water Inlet Connector 3/4" part RTG20164J probably around $66. I believe it includes the filter. Hope this helps.
@staceyparrott6185 Жыл бұрын
@@cfldriven Thank you
@AliBaba-hn8tv2 жыл бұрын
Thank you, youvideo was helpful.
@cfldriven2 жыл бұрын
Ali, thank you for watching.
@kphyrum2 жыл бұрын
Very useful!
@cfldriven2 жыл бұрын
Phyrum, good to hear you found this video useful. thank you for watching.
@TheGreatDadoo3 жыл бұрын
it's a good video so long as you play it at 2x speed...
@cfldriven3 жыл бұрын
LOL, thank you for watching, even at 2X.
@rickywoodard8203 жыл бұрын
Shouldn’t u purge the air out before turning unit on?
@cfldriven3 жыл бұрын
Yes and that is what we do at 4:26 when we run the hot water faucet before starting the unit. The actual run in the unit is short so as soon as the water valve is opened and you open the hot water the air is purged. What you see in the video is the air after traveling through the plumbing to get to the sink. Would it hurt to do it the way you suggest, absolutely not. Thank you for the suggestion.
@believeinjesus8300 Жыл бұрын
How about if the the filter is stripped all to hell?
@cfldriven Жыл бұрын
Teflon tape may work while looking for a replacement part from Rheem or plumbing store. You could also try a search on Home Depot for Rheem PROTECH Inlet Water Filter, currently $11.
@believeinjesus8300 Жыл бұрын
@@cfldriventhanks ! I found a tool that connects to a socket wrench, the tool goes into the inlet filter it’s called The Tankless Tool. Hope it works.
@cfldriven Жыл бұрын
@@believeinjesus8300 I see your filter is stuck in place, I thought it was already out. Let us know if the tool works as this might be a useful fix for others.
@believeinjesus8300 Жыл бұрын
@@cfldriven 👍🏾
@believeinjesus8300 Жыл бұрын
@@cfldriven tool is supposed to show up today. Hopefully it shows up, and hopefully it works.
@bencorwin2 жыл бұрын
Thanks!
@cfldriven2 жыл бұрын
You are very welcome, thanks for watching.
@edwardcollins32042 жыл бұрын
What if there’s no filter
@cfldriven2 жыл бұрын
It comes with a filter. If it missing get one as you don't want particles causing a clog.
@rodneywaites71642 жыл бұрын
Rheem tankless water heater error 29
@tomh94702 жыл бұрын
That filter assembly does not seal with torque…the o-ring just has to be seated in the housing…so, turn the filter until it hits bottom…no need to use a wrench!
@cfldriven2 жыл бұрын
My experience with two of these units has been different. Removing the filter for the first time involved a wrench and seating it without a wrench always resulted in a leak. Glad to hear this is not always the case. Thank you for sharing.
@tomh94702 жыл бұрын
@@cfldriven Possible the filter was not screwed all the way down until you used a wrench, so it leaked. The filter uses an o-ring, not a bottom gasket/seal, so torque is irrelevant. Still, a very good video! Some of the videos on annual tankless flushes do not mention the filter, so your video is a terrific reference!
@GB-fe1ci Жыл бұрын
I hand tightend the filter but it was leaking a little and then used a wrench to give mine a little extra snug fit and it's still dripping or leaking a little. But I'm in the middle of the cleaning so I hope after the flush I'll re seat it and hopefully it stops leaking. 1st flush on a 1.5 year old unit.
@cfldriven Жыл бұрын
@@GB-fe1ci There are two gaskets on the filter, 2:17 in video, make sure they are clean and in place. Also a touch of plumber's grease not Vasoline might help.
@GB-fe1ci Жыл бұрын
I got it. I didn't have the O ring seated properly. Thanks for your informative video!
@gamecrazy49Ай бұрын
Whats that black nipple at the front left of the machine?
@cfldrivenАй бұрын
It is the service drain for the condensate neutralizer. Used when replacing the neutralizer unit.
@gamecrazy49Ай бұрын
@cfldriven would it damage the unit if unscrewed and drained?
@cfldrivenАй бұрын
@@gamecrazy49 You would use this drain prior to replacing the neutralization tank otherwise leave it alone.
@technicalfacilities52953 жыл бұрын
thats the most yellow water I've almost ever seen
@cfldriven3 жыл бұрын
Yes the different light color temperatures in the kitchen fooled the auto white balance of the camera. The sink is white and the water is really clear.