Electronic flat roof leak detection Testing a leaking roof Roof surveys

  Рет қаралды 26,265

Steve Roofer

Steve Roofer

Күн бұрын

Пікірлер: 56
@d8461
@d8461 3 жыл бұрын
I'm no roofer but to me this shows somebody who takes pride in their work and has a keen interest in all aspects of their job. Cant beat someone who's passionate about what they do. Brilliant.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Thanks
@benrichards1
@benrichards1 3 жыл бұрын
Glad you're making videos again. Very informative.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
More to come!
@jaki1979
@jaki1979 3 жыл бұрын
Yes please
@chriscolameco6850
@chriscolameco6850 15 күн бұрын
Which moisture meter do you use?
@haroon420
@haroon420 3 жыл бұрын
All that insulation being ripped apart is making my eyes water!! 💸💸💸
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Yes it was such a shame nex video will explain why
@dannymurphy1779
@dannymurphy1779 3 жыл бұрын
Very interesting Steve. A chain is only as strong as its weakest link! Looking forward to the reveal.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Correct except we are not training our links
@philsims6607
@philsims6607 3 жыл бұрын
As has already been said great to have you back Steve! You didn't say in the video what was wrong to cause the leak?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
I will do that in one of my next videos
@brandongranados5569
@brandongranados5569 Жыл бұрын
The membrane had small cuts that barely let water seap in. Maybe before setting the membrane the roll was sitting on top of gravel, when unrolled it got cut. Maybe somebody had a sharp object underneath their shoe when setting it up, somebody threw a rock on the roof, when setting it up they might have dropped their sviccors or box cutter knife on accident leaving a really small hole barely noticeable to the eye. Etc
@SteveRoofer
@SteveRoofer Жыл бұрын
No, we know what the problem was. The problem was that he didn't use enough liquid to saturate the reinforcing membrane. You could actually see that some of it was still naked.
@aryana2324
@aryana2324 10 ай бұрын
Hello great video! I have a question, Ive a concrete ceiling which has been waterproofed but still I see water during inside the hoouse thorugh a crack, the issue here is that none of the experts who came to inspect where able to get to the source of the leak, we see the leak but not knowing from its coming, any trick to check that please?
@warrenbarton6608
@warrenbarton6608 3 жыл бұрын
Hi Steve, why do you say "good choice of insulation,tissue-faced not foiled-faced ? Thanks Warren
@haroon420
@haroon420 3 жыл бұрын
Tissue faced is the recommended one I believe but I think everyone uses foil because of price. And I don’t think performance is *much* more different.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
@aroon420 is correct basicly tiles faced insulation is more oven cell IE it breaths a little better however its more expensive
@dominiktur6235
@dominiktur6235 2 жыл бұрын
Good job.But there are better and faster methods, such as the electric imulsus method on a wet and dry roof. Good for any weather. Although I must admit that RWS Tramex is one of my favorite devices. Best regards from Belgium and good luck.
@SteveRoofer
@SteveRoofer 2 жыл бұрын
Thanks for the tips!
@AWB70UK
@AWB70UK 3 жыл бұрын
Another great video, I've been watching these now for months and the tips I've picked up are priceless regarding why warm roofs fail. Just waiting for a break in the weather before getting mine fitted which hopefully is very soon. I wish you worked up our way as I often find myself having to point things out to the roofer. Steve, one things I'm still confused about is I appreciate that you recommend using a self adhesive VCL but in one of your previous videos you advised someone to use a novia polythene kit which I bought at the time, one thing I'm not sure about is what do you think is the better detail for the vcl at the top of the kingspan layer? Folding the excess vcl over the upstand and perimeter before fitting the secondary layer of osb or folding it back in over the top of the kingspan and taping it down?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
If its a warm roof you should be using Alutrix 600 novia polythene kit can be used for a warm roof but is more difficult to use I think he already had it and that's why it was used
@AWB70UK
@AWB70UK 3 жыл бұрын
@@SteveRoofer yes, I wish I did get the alutrix but I found out about the product after I had already bought the Novia. The guy who did the drawing just stated "vcl" then I found a celotex detail showing 1000 gauge vcl so went with that. I had to buy 100m2 worth when I only need 18 so I couldn't really buy the alutrix as well. Any tips or mistakes that should be avoided when using the Novia?
@timmymues9256
@timmymues9256 2 жыл бұрын
If only the top layer Epdm is repaired and leak proof, is it possible that the moisture drys by time itself?
@SteveRoofer
@SteveRoofer 2 жыл бұрын
yes but slowly
@kenmammel7748
@kenmammel7748 Жыл бұрын
I've got water between layers on my flat roof. It sounds like a tennis shoe sneaker after walking under water. From the sky inward, there is a standing seam metal roof, then TPO rubber roof, then 2 layers of ice and water-shield. How can I get the large amount of trapped water out of there?
@bobjit252
@bobjit252 2 жыл бұрын
Doesn’t this show that these types of roofs aren’t actually that good as the workmanship doesn’t look bad , and looks as though it’s been done the right way ?
@SteveRoofer
@SteveRoofer 2 жыл бұрын
Its the workmanship they didn't apply the liquid to the correct depth
@kevinrae3299
@kevinrae3299 3 жыл бұрын
Maybe laid the boards in the wet? Liquid applied should have a carrier membrane. Is the water detector a good investment?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Think it was dry but one of my next videos will explain why we striped this. is it a good investment if it lasts another 5 years yes but at around 2K No
@peteramberley9952
@peteramberley9952 3 жыл бұрын
Looked like duoply epdm or was that the grid lines put on?. What we really want to know Steve is the fallout and who's paying for it to be put right. There's a lot of money someone's losing.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
All that info will be coming in my next video
@saintslad5399
@saintslad5399 3 жыл бұрын
Very informative video thanks. One question though, I assume this piece of equipment works similar to a conductive damp meter you would stick in walls to find rising damp etc. Does this piece of equipment have the same shortfalls of a damp meter for example giving false high readings when a conductive material such as foil backed plasterboard is detected within the roof?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Yes, also won't work through some single plys such as rubber but I have tested it on rubber and it worked!
@asif530
@asif530 3 жыл бұрын
Would it have helped if there was ply ontop of the insulation?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
No they didn't apply the liquid roofing correctly
@THE-AIDEN-PROJECT
@THE-AIDEN-PROJECT 3 жыл бұрын
Hi Steve, would you cover SE3 at all? Could you give an indication on how much a non invasive flat roof survey would cost? Roof is less than 10m2
@SteveRoofer
@SteveRoofer 3 жыл бұрын
Email me with more info and photos and ill get back to you with a cost info@londonflatroofing.co.uk
@ianhastwell9194
@ianhastwell9194 2 жыл бұрын
Crazy .... just let's get this right...you laid a roof on top of the old roof ...that's fine but you say roof has only been down a few days and had rain before you arrived to test ...maybe the roofers got caught out by the rain when doing the installation and water got under the insulation before they could cover it up ...the liquid roof looked OK to me...why is the customer walking around the roof ....was water showing inside ...if not then that's just stupid ripping up the roof ...as if new roof wasn't leaking into the building surely what water was sitting on the old roof would of evaporated in time and would of been find 🤔
@SteveRoofer
@SteveRoofer 2 жыл бұрын
The problem was the water was in the roof and could not get out
@ML167305
@ML167305 10 ай бұрын
@@SteveRooferHey Steve what’s the name of this machine or the manufacturer? I’m across the pond and no one does this over here. It would be cool.
@zigavojska1672
@zigavojska1672 3 жыл бұрын
culdnt you just put another layer of liquid insulation?
@SteveRoofer
@SteveRoofer 3 жыл бұрын
No as there was water trapped in the constitution now
@zigavojska1672
@zigavojska1672 3 жыл бұрын
it would dry out eventually
@SteveRoofer
@SteveRoofer 3 жыл бұрын
​ @Ziga Vojska Possibly and there may not be any mildew or fungus that grown. however, the scaffolding is there the opportunity is there the other roofer is at fault and needs to give the customer a proper roof with no Ifs and buts. What would you do if you were the customer?
@advancedue476
@advancedue476 6 ай бұрын
They probably should have painted that membrane over the wood as well
@dublinboy
@dublinboy 3 жыл бұрын
That could of been put down with wet weather. Sorry to say but flat roofs in the uk are lagging miles behind europe.
@SteveRoofer
@SteveRoofer 3 жыл бұрын
It is wet weather and bad workmanship and choice of materials
@Jackzuk
@Jackzuk 3 жыл бұрын
Has the poor owner had to pay twice to have this roof fitted due to the 1st persons poor work or was he lucky enough to have insurance company cover it
@SteveRoofer
@SteveRoofer 3 жыл бұрын
From my understanding, the roofer wasn't paid really unfortunate as he tried his best and used a lot of expensive materials but as you can see the work was substandard
@PeakyBlinder
@PeakyBlinder 2 жыл бұрын
Always perform an electronics test on completion of any liquid roof, As morons will use the roof as a storage area. This will then puncture the membrane. And never apply liquid directly to insulation. Fix ply onto of the insulation to prevent punctures.
@beltdrivetypea6534
@beltdrivetypea6534 3 жыл бұрын
Why not just go over it again rather than rip it up
@SteveRoofer
@SteveRoofer 3 жыл бұрын
It had water under it and they hadn't insulated around the side
@beltdrivetypea6534
@beltdrivetypea6534 3 жыл бұрын
@@SteveRoofer cheers
@eddjordan2399
@eddjordan2399 2 жыл бұрын
what a waste of materials
@SteveRoofer
@SteveRoofer 2 жыл бұрын
Yes unfortunate
Vapour barriers for roofs and walls explained
9:58
Steve Roofer
Рет қаралды 118 М.
why roofs in Sydney leak only in heavy rain
8:20
The Roofing Professionals Westside
Рет қаралды 86 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
How to find a roof leak that does not have obvious damage.
11:27
Grand Roofing Inc.
Рет қаралды 220 М.
Condensation In the loft things not to do
10:53
Steve Roofer
Рет қаралды 55 М.
leak detection video
9:10
otshooter
Рет қаралды 8 М.
Warm roofs, the biggest mistake I see when doing a roof inspection.
7:34
Inspecting a 2 month old TPO roof that still leaks
16:40
JACK @ DOCS ROOFING
Рет қаралды 7 М.
Badly fitted insulation between joists and thermal imaging
8:54
Steve Roofer
Рет қаралды 233 М.
How To Find A Leak In Your Shingles
5:51
HouseImprovements
Рет қаралды 361 М.
Hybrid roofs explained  Flat roofs Warm and Cold
11:59
Steve Roofer
Рет қаралды 188 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН