I'm no roofer but to me this shows somebody who takes pride in their work and has a keen interest in all aspects of their job. Cant beat someone who's passionate about what they do. Brilliant.
@SteveRoofer3 жыл бұрын
Thanks
@benrichards13 жыл бұрын
Glad you're making videos again. Very informative.
@SteveRoofer3 жыл бұрын
More to come!
@jaki19793 жыл бұрын
Yes please
@chriscolameco685015 күн бұрын
Which moisture meter do you use?
@haroon4203 жыл бұрын
All that insulation being ripped apart is making my eyes water!! 💸💸💸
@SteveRoofer3 жыл бұрын
Yes it was such a shame nex video will explain why
@dannymurphy17793 жыл бұрын
Very interesting Steve. A chain is only as strong as its weakest link! Looking forward to the reveal.
@SteveRoofer3 жыл бұрын
Correct except we are not training our links
@philsims66073 жыл бұрын
As has already been said great to have you back Steve! You didn't say in the video what was wrong to cause the leak?
@SteveRoofer3 жыл бұрын
I will do that in one of my next videos
@brandongranados5569 Жыл бұрын
The membrane had small cuts that barely let water seap in. Maybe before setting the membrane the roll was sitting on top of gravel, when unrolled it got cut. Maybe somebody had a sharp object underneath their shoe when setting it up, somebody threw a rock on the roof, when setting it up they might have dropped their sviccors or box cutter knife on accident leaving a really small hole barely noticeable to the eye. Etc
@SteveRoofer Жыл бұрын
No, we know what the problem was. The problem was that he didn't use enough liquid to saturate the reinforcing membrane. You could actually see that some of it was still naked.
@aryana232410 ай бұрын
Hello great video! I have a question, Ive a concrete ceiling which has been waterproofed but still I see water during inside the hoouse thorugh a crack, the issue here is that none of the experts who came to inspect where able to get to the source of the leak, we see the leak but not knowing from its coming, any trick to check that please?
@warrenbarton66083 жыл бұрын
Hi Steve, why do you say "good choice of insulation,tissue-faced not foiled-faced ? Thanks Warren
@haroon4203 жыл бұрын
Tissue faced is the recommended one I believe but I think everyone uses foil because of price. And I don’t think performance is *much* more different.
@SteveRoofer3 жыл бұрын
@aroon420 is correct basicly tiles faced insulation is more oven cell IE it breaths a little better however its more expensive
@dominiktur62352 жыл бұрын
Good job.But there are better and faster methods, such as the electric imulsus method on a wet and dry roof. Good for any weather. Although I must admit that RWS Tramex is one of my favorite devices. Best regards from Belgium and good luck.
@SteveRoofer2 жыл бұрын
Thanks for the tips!
@AWB70UK3 жыл бұрын
Another great video, I've been watching these now for months and the tips I've picked up are priceless regarding why warm roofs fail. Just waiting for a break in the weather before getting mine fitted which hopefully is very soon. I wish you worked up our way as I often find myself having to point things out to the roofer. Steve, one things I'm still confused about is I appreciate that you recommend using a self adhesive VCL but in one of your previous videos you advised someone to use a novia polythene kit which I bought at the time, one thing I'm not sure about is what do you think is the better detail for the vcl at the top of the kingspan layer? Folding the excess vcl over the upstand and perimeter before fitting the secondary layer of osb or folding it back in over the top of the kingspan and taping it down?
@SteveRoofer3 жыл бұрын
If its a warm roof you should be using Alutrix 600 novia polythene kit can be used for a warm roof but is more difficult to use I think he already had it and that's why it was used
@AWB70UK3 жыл бұрын
@@SteveRoofer yes, I wish I did get the alutrix but I found out about the product after I had already bought the Novia. The guy who did the drawing just stated "vcl" then I found a celotex detail showing 1000 gauge vcl so went with that. I had to buy 100m2 worth when I only need 18 so I couldn't really buy the alutrix as well. Any tips or mistakes that should be avoided when using the Novia?
@timmymues92562 жыл бұрын
If only the top layer Epdm is repaired and leak proof, is it possible that the moisture drys by time itself?
@SteveRoofer2 жыл бұрын
yes but slowly
@kenmammel7748 Жыл бұрын
I've got water between layers on my flat roof. It sounds like a tennis shoe sneaker after walking under water. From the sky inward, there is a standing seam metal roof, then TPO rubber roof, then 2 layers of ice and water-shield. How can I get the large amount of trapped water out of there?
@bobjit2522 жыл бұрын
Doesn’t this show that these types of roofs aren’t actually that good as the workmanship doesn’t look bad , and looks as though it’s been done the right way ?
@SteveRoofer2 жыл бұрын
Its the workmanship they didn't apply the liquid to the correct depth
@kevinrae32993 жыл бұрын
Maybe laid the boards in the wet? Liquid applied should have a carrier membrane. Is the water detector a good investment?
@SteveRoofer3 жыл бұрын
Think it was dry but one of my next videos will explain why we striped this. is it a good investment if it lasts another 5 years yes but at around 2K No
@peteramberley99523 жыл бұрын
Looked like duoply epdm or was that the grid lines put on?. What we really want to know Steve is the fallout and who's paying for it to be put right. There's a lot of money someone's losing.
@SteveRoofer3 жыл бұрын
All that info will be coming in my next video
@saintslad53993 жыл бұрын
Very informative video thanks. One question though, I assume this piece of equipment works similar to a conductive damp meter you would stick in walls to find rising damp etc. Does this piece of equipment have the same shortfalls of a damp meter for example giving false high readings when a conductive material such as foil backed plasterboard is detected within the roof?
@SteveRoofer3 жыл бұрын
Yes, also won't work through some single plys such as rubber but I have tested it on rubber and it worked!
@asif5303 жыл бұрын
Would it have helped if there was ply ontop of the insulation?
@SteveRoofer3 жыл бұрын
No they didn't apply the liquid roofing correctly
@THE-AIDEN-PROJECT3 жыл бұрын
Hi Steve, would you cover SE3 at all? Could you give an indication on how much a non invasive flat roof survey would cost? Roof is less than 10m2
@SteveRoofer3 жыл бұрын
Email me with more info and photos and ill get back to you with a cost info@londonflatroofing.co.uk
@ianhastwell91942 жыл бұрын
Crazy .... just let's get this right...you laid a roof on top of the old roof ...that's fine but you say roof has only been down a few days and had rain before you arrived to test ...maybe the roofers got caught out by the rain when doing the installation and water got under the insulation before they could cover it up ...the liquid roof looked OK to me...why is the customer walking around the roof ....was water showing inside ...if not then that's just stupid ripping up the roof ...as if new roof wasn't leaking into the building surely what water was sitting on the old roof would of evaporated in time and would of been find 🤔
@SteveRoofer2 жыл бұрын
The problem was the water was in the roof and could not get out
@ML16730510 ай бұрын
@@SteveRooferHey Steve what’s the name of this machine or the manufacturer? I’m across the pond and no one does this over here. It would be cool.
@zigavojska16723 жыл бұрын
culdnt you just put another layer of liquid insulation?
@SteveRoofer3 жыл бұрын
No as there was water trapped in the constitution now
@zigavojska16723 жыл бұрын
it would dry out eventually
@SteveRoofer3 жыл бұрын
@Ziga Vojska Possibly and there may not be any mildew or fungus that grown. however, the scaffolding is there the opportunity is there the other roofer is at fault and needs to give the customer a proper roof with no Ifs and buts. What would you do if you were the customer?
@advancedue4766 ай бұрын
They probably should have painted that membrane over the wood as well
@dublinboy3 жыл бұрын
That could of been put down with wet weather. Sorry to say but flat roofs in the uk are lagging miles behind europe.
@SteveRoofer3 жыл бұрын
It is wet weather and bad workmanship and choice of materials
@Jackzuk3 жыл бұрын
Has the poor owner had to pay twice to have this roof fitted due to the 1st persons poor work or was he lucky enough to have insurance company cover it
@SteveRoofer3 жыл бұрын
From my understanding, the roofer wasn't paid really unfortunate as he tried his best and used a lot of expensive materials but as you can see the work was substandard
@PeakyBlinder2 жыл бұрын
Always perform an electronics test on completion of any liquid roof, As morons will use the roof as a storage area. This will then puncture the membrane. And never apply liquid directly to insulation. Fix ply onto of the insulation to prevent punctures.
@beltdrivetypea65343 жыл бұрын
Why not just go over it again rather than rip it up
@SteveRoofer3 жыл бұрын
It had water under it and they hadn't insulated around the side