@wpherigo1
@wpherigo1 6 жыл бұрын
Nice video. Thanks for putting it out. That’s a great idea to consider not only the other professional installers like yourself, but the DIY subscribers.
@neomatrix2722
@neomatrix2722 5 ай бұрын
Thanks for sharing Johnny love you bro up here in Canada
@dobson777a
@dobson777a 6 жыл бұрын
Johnny pease don't consider this trolling but let me clarify. The midnite solar SPD responds in less than 15 ns. Which in length is a little over 12 inches. That is about the length of the wires on the SPD. Not a major concern for wire length because the next closest sensitive device should be yards away through the electrical wiring from the panel. I bought two of these from you (one for each utility panel) due to convenience. Both Home Depot and Lowes carry surge suppressors for electrical panels and I've used several brand for my homes including my rentals for over 20 years. I have never had a surge related device failure. I highly recommend these devices for every home and they are very easy to install.
@GainSolarPower
@GainSolarPower 6 жыл бұрын
dobson777a I agree with you Robert and I don’t doubt there are other good brands out there. The installation manual for the SPD says to “avoid excess lead lengths and the need for sharp bends in the wires”. I’m just an avid install Manual reader/follower. The whole reasons for this video was because people always have questions about the blue light ufo things....
@fasnuf
@fasnuf Жыл бұрын
LOL. Blue light special! That one got me! Nice presentation. I wonder if these ever fail and send all current to ground making a fire.
@yankey4
@yankey4 6 жыл бұрын
@GainSolarPower
@GainSolarPower 6 жыл бұрын
yankey4 thanks yankee. I’d love to get a shout out from you on your channel. You seem to have good traction. Did you call me one time a while back? Let me know if you have any video requests.
@AndreMiller-RED
@AndreMiller-RED 5 жыл бұрын
The mallet made me like this video!!!
@scotthenderson4376
@scotthenderson4376 Жыл бұрын
I have blown 2 inverters (grid tie) without an SPD installed. I installed one of these in the top of a sub panel (powered strait from the main leads on the main panel) Anyway my inverter faulted out with an ark fault and the breaker for this SPD was tripped. Reset all and running fine now. So I assume I had a power spike on the A/C input side as the solar wasn't that high (cloudy day)
@josegarcia-th3pj
@josegarcia-th3pj Жыл бұрын
I INSTALLED THEM AROUND 8 YEARS AGO NOW I TRY TO KNOW WICH MODELS ARE?
@TheRedneckprepper
@TheRedneckprepper 6 жыл бұрын
Lets ask Scott tell us about how and why it works ?
@GainSolarPower
@GainSolarPower 6 жыл бұрын
Theredneck Prepper he’s a mechanical engineer. Definitely not electrical.
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 2 жыл бұрын
HOWdy G-S-S, You seem to wonder what the difference was between your TWO (2) SPD's that you unboxed & why they were different in appearance the FIRST (1st) SPD was a TYPE-2 SPD the SECOND (2nd) SPD was labeled as a TYPE-1 SPD COOP ...
@russb2945
@russb2945 6 жыл бұрын
I always get a charge out of your videos...both in and out...ZAP..POW...ouch..! I should have hooked it up with shorter leads and no sharp bends...
@uns3cur3
@uns3cur3 Жыл бұрын
How would this get wired into a 120V AC main panel?
@EdenEchoes
@EdenEchoes 2 жыл бұрын
I was wondering....Wouldn't 120 volts, be OVER the 115-AC version of the SPD, and therefore to protect the 120 Volt AC side of the circut, and avoid damage to the 115 version, wouldn't we need to go with the 300-AC Version of the SPD, since 120 volts AC is between 115 and 300 Volts? Also I think midnite has possibly changed the Part numbers, and the AC&DC Designations of these now days, I know you put this video out 4 years ago?
@GainSolarPower
@GainSolarPower 2 жыл бұрын
The 115 would install on the hot and neutral of a circuit. The 300 installs on the two hot legs of a 240 v circuit or service
@electromechanicalstuff2602
@electromechanicalstuff2602 5 жыл бұрын
U always use the midnights. Y? I bought the Eaton ones. Dont remeber back when i was looking y i went with Eaton. My guess is the biggest eaton unit had the most/highest joul protection. Id have to look it up. I use mine on my house grid power/ generator l, no solar yet. Edit just looked it up. Eaton chsp2ultra is the 120/240v Rated at 2820 jouls With clamping of 600v L-N 1000vL-L 800v N-G 600v L-G About $108 at Home depot Midnight mnspd300 is the120/240v Rated at 3130 jouls With a clamping of 775v @$89 So looks like midnight might be slightly better jouls wise. But midnite does have different voltages and for dc eatont doesnt. Mike holms can go pound sand i guess
@GainSolarPower
@GainSolarPower 5 жыл бұрын
electromechanical stuff they are NEMA3r and they work for me. I’m sure there are plenty of good ones out there
@electromechanicalstuff2602
@electromechanicalstuff2602 5 жыл бұрын
@@GainSolarPower ya the eatons are not made for outside thats for sure. Well u definatly made up my mind next time i get one
@dadoymatulac
@dadoymatulac Жыл бұрын
do u have link where u buy this
@dwfdwf5371
@dwfdwf5371 6 жыл бұрын
why do we need 2 on most inverters
@JasonAndrade427
@JasonAndrade427 6 жыл бұрын
dwf dwf input and output
@GainSolarPower
@GainSolarPower 6 жыл бұрын
dwf dwf you really don’t. I have two because I want a backup/loner for myself and my customers. I’m a prepper so redundancy is always in mind. Also needed the extra inverter for ac coupling. When you ac couple a grid tied inverter to a battery inverter the maximum possible output power of the GTI (inverter handles the solar) exceed 90% of the continuous output power of the battery inverter. Sorry long answer. You don’t need too. I’m just a solar guy with lots of junk!!!
@GainSolarPower
@GainSolarPower 6 жыл бұрын
Oh man I spaced on this question. Thought you were asking why two inverters. You need two spds because inverter chargers have an input from the grid or gen and an output to a load panel.
@dwfdwf5371
@dwfdwf5371 6 жыл бұрын
lol it's all those kids Johnny. I understand it's for the path of the overload.
MidNite Solar - Introduction to the Surge Protection Device
9:38
MidNite Solar Inc.
Рет қаралды 26 М.
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 48 МЛН
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 4 МЛН
The Giant sleep in the town 👹🛏️🏡
00:24
Construction Site
Рет қаралды 20 МЛН
All about Wireways for Solar Installs
10:21
Gain Solar Services
Рет қаралды 9 М.
Installing 3 phase surge protection
19:54
Residual Electrical
Рет қаралды 21 М.
DIY Home Solar System Lightning Protection EMP Shield
18:26
Projects With Everyday Dave
Рет қаралды 36 М.
Current Technology Surge Protection (TVSS/SPD) Part 1 of 2
9:03
criticalpowergroup
Рет қаралды 81 М.
Equipment Grounding for PV Systems
26:14
Penn State Solar Center
Рет қаралды 122 М.
Do surge protectors really work?
20:43
ScottiesTech.Info
Рет қаралды 65 М.
MidNite Solar's Surge Protection Comparison Test
9:28
MidNite Solar Inc.
Рет қаралды 19 М.
Off Grid Earthing & Bonding Made Simple | ØY17
21:44
Cory Mac - ØY Electrical
Рет қаралды 50 М.
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 48 МЛН