How to check the Flame Sensor?

  Рет қаралды 25,911

Taddy Digest

Taddy Digest

Күн бұрын

Пікірлер: 100
@byronlentz4825
@byronlentz4825 8 ай бұрын
I always knew this but I have never actually measured the amps. Thanks for the class.
@TaddyDigest
@TaddyDigest 8 ай бұрын
Happy to help!
@andresbarragan8595
@andresbarragan8595 8 ай бұрын
FROM CHICAGO EXELENT I'M ONE OF MANY PEOPLE FOLOWING YOUR VIDEOS THANK YOU SO MUCH
@Quentyn73
@Quentyn73 8 ай бұрын
The microamps are not identical on all furnaces, so they need to be checked against the furnace documentation. Those very rarely need to be replaced. They are just a piece of metal. It's usually connectors that are corroded that give problems
@myHVAClife
@myHVAClife 8 ай бұрын
Notice you did not actually show cleaning the flame sensor and if it changed your reading. That is usually all it needs 9 of 10 times. Can count on one hand how many flame sensors I have actually had to replace in 20 years, and still have a couple fingers left. They were either broken/cracked on the insulator and one was burnt into from an old LP Gas pack.
@philindeblanc
@philindeblanc 7 ай бұрын
Well, the replacement is $40 !! vs maybe $10, so someone is happy selling them, LOLOL. Its amazing the amount of crappola I see people doing.
@sfl6307
@sfl6307 8 ай бұрын
I have no idea, that’s why I come here to learn!
@rcstl8815
@rcstl8815 8 ай бұрын
Seems like a lot of work when two seconds removing and rubbing it on material and reinstalling will work or not. If not, I use a resistor/ diode jumper (it fakes the reading back to the board) to make sure the board is good. Flame sensors rarely, almost never go bad they just corrode and need to be cleaned/ wiped off as long as the porcelain is not cracked and the burner ground is good.
@TaddyDigest
@TaddyDigest 8 ай бұрын
Yup you're right usually you can clean them off and then reinstall and everything works fine.
@allanbrito13
@allanbrito13 8 ай бұрын
How did you make that jumper? Would like to keep one handy
@realSamAndrew
@realSamAndrew 8 ай бұрын
@rcstl, like the person before me, I also am interested in more info on that diode jumper.
@rcstl8815
@rcstl8815 8 ай бұрын
@@realSamAndrew I am trying to find the original article on how to make it. It came from the hvac-talk board. User slctech or my id. It will take some searching. The last note I saw was from 2016. But a male spade (flame sensor spades are male) to a 1M ohm resistor to a 1N4005 diode to an alligator clip. Use some wire to make it longer and separate the components. The male spade is plugged into the FS lead to the board and when the GV opens clip the alligator to the ground (burner chassis). The diode creates the DC feedback the board is expecting.
@TheRoland444
@TheRoland444 8 ай бұрын
One interesting characteristic of the micro-amps with a real flame is that the current varies and is not "rock steady." When you "fake it" with a resistor and a diode does the controller detect that it's not "the real thing" because the current doesn't follow the pattern of a flame?@@rcstl8815
@livingyourbestlife711
@livingyourbestlife711 8 ай бұрын
absolutely great vlog. You do good work Taddy!
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thanks so much
@truettunderwood7615
@truettunderwood7615 8 ай бұрын
Excellent video brother! I’m glad I found your channel👍
@palitopeque2111
@palitopeque2111 8 ай бұрын
I started at the field couple years ago and your videos are very helpful thanks alot tadd for sharing your experiences and knowledge
@LegendKiller2073
@LegendKiller2073 8 ай бұрын
Great video Tad!
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thanks!
@JR-ch8rt
@JR-ch8rt 8 ай бұрын
Bro you should have an mascot name tip, so you can say he is de one giving us the “knowledge”. So you can say “Hey this is Tip and and I am Tad here to drop a tip for technicians”
@dporrasxtremeLS3
@dporrasxtremeLS3 8 ай бұрын
That's a Mouthful ...
@christianurbano1483
@christianurbano1483 8 ай бұрын
Awesome job, straight to the point, not filters, thanks .
@RockoRocko-rz7kx
@RockoRocko-rz7kx 8 ай бұрын
I always went by 2-4 micro amps is a good read and no cleaning of the stainless steel rod required.
@jrh86
@jrh86 8 ай бұрын
Nice instruction thanks
@andrewbrown9497
@andrewbrown9497 6 ай бұрын
Interesting I have only seen two bad flame sensors in over 30 years. Back in the late 90s trane had issues with with their very thin sensors on propane systems. The only other one was one that I stepped on while do a cleaning of a furnace. I would like to know why that was bad? I have seen several of your videos and know you know what you are doing, but that sensors looked good. I have a guess that wasn't the issue. I would be willing to bet the burners are worn and causing the flame to drop. The longer sensors is in the flame better. Goodman had issues with burners doing that. The field fix is a hack. You loosen the 4 screws to the gas manifold. Put a washer, the thickness of a penny behind each of the upper 2 screws. This will cause the flame to hit the sensors again. The fix is to replace the burners that was what the recall was on those units years ago. Happy Easter
@my-yt-inputs2580
@my-yt-inputs2580 8 ай бұрын
I'm in the process of running down a flame sensor issue with my Trane package unit(gas pack). Not definite yet but it does appear that in my case the flame sensor bracket was losing ground bond and causing early shutdown. If so I've been told this is quite rare. I'm going to add a separate grounding wire from the mount bracket to see if that keeps it working. I still need to check it as you're showing in the video. But it's outside and cold and working now so will wait till I have to open it up again.
@aaganik6726
@aaganik6726 8 ай бұрын
Great videos, have been a long time follower and have loved each one
@maxsantana1
@maxsantana1 8 ай бұрын
Thank you. Now I know.
@bigdaddy5948
@bigdaddy5948 8 ай бұрын
Thanks. Didn't know there were adjustable flame sensors out there.
@TaddyDigest
@TaddyDigest 8 ай бұрын
Glad I could help
@teflondon1620
@teflondon1620 8 ай бұрын
tadonious! great content bro!
@TaddyDigest
@TaddyDigest 8 ай бұрын
More to come!
@jamnben278
@jamnben278 8 ай бұрын
Thanks Tad!
@williamserver4332
@williamserver4332 8 ай бұрын
Thanks for another helpful video
@chriseh09
@chriseh09 5 күн бұрын
Very good video and thank you for sharing but I was wondering why you didn't first check from the IFC to the flame sensor without the burner ignited. Flame rectification requires a AC signal of around 50-180 AC volts from the IFC to the flame sensor. The flame sensor will have AC voltage on it when the unit has power on it and you could get shocked! Once the flame sensor is in the flame, that AC current travels through the flame as 2-7 DCMA through the burner and through the ground back to the IFC. I have seen Flame Sensors misdiagnosed because there was no AC voltage going to the flame sensor before ignition.
@TaddyDigest
@TaddyDigest 4 күн бұрын
good stuff thanks for sharing
@d.l.harrington4080
@d.l.harrington4080 8 ай бұрын
One note here that he should mention. The rod may look clean. You may get the rest of the season out of it if you clean it with sandpaper. What happens is the rod metal becomes crystalized from the heat and changes its electrical properties. To avoid call backs or a cold night, replace it ASAP. Just did one the other night.
@pedrovalet1506
@pedrovalet1506 8 ай бұрын
If the ceramic is cracked, the small amount of current goes directly to the ground instead of the control board.
@HvAcAprentice
@HvAcAprentice 7 ай бұрын
Great Video!!👍
@rodolfomanuel797
@rodolfomanuel797 8 ай бұрын
thank you! great video!
@juancarlosbarrios8377
@juancarlosbarrios8377 8 ай бұрын
Thank for share your video👍😎
@jonathanbradberry2531
@jonathanbradberry2531 8 ай бұрын
Better check that heat exchanger
@TheRoland444
@TheRoland444 8 ай бұрын
You don't want a "dancing flame" when the main blower turns on shortly after the ignition.
@LilMagik5
@LilMagik5 8 ай бұрын
Thanks you so much tad
@davidhorne2326
@davidhorne2326 8 ай бұрын
That” hard to see” only gets worse with age! At first more light helped, but eventually the eye glasses become mandatory! Thanks for giving those mA values!
@TheRoland444
@TheRoland444 8 ай бұрын
We are dealing with micro-amp (ua) values, not milli-amp (ma) values, thanks for a great video
@davidhorne2326
@davidhorne2326 8 ай бұрын
I stand corrected. Thanks!
@mauricioromero2280
@mauricioromero2280 8 ай бұрын
This kind of sensor is similar of the oven type. Need flame for send son voltage with microamps.
@TheRoland444
@TheRoland444 8 ай бұрын
Actually, in gas ovens the sensor is a combination of an intermittent pilot & a thermocouple-for so-called "off grid" stoves.------More traditional line operated stoves (AC power required) simply have a globar heating element wired in series with the gas valve solenoid.-----Gas valve cannot open, stay open and allow gas flow unless globar is "red hot."
@xraybravo7180
@xraybravo7180 8 ай бұрын
That flame sensor getting 120v . Watch out. ⚠️ 📢
@lakeithwashum6497
@lakeithwashum6497 8 ай бұрын
My unit is so old can't find a replacement. What do you suggest?
@SashaNem
@SashaNem 6 ай бұрын
thanks
@TaddyDigest
@TaddyDigest 6 ай бұрын
You're welcome
@thelifeofguitar8082
@thelifeofguitar8082 8 ай бұрын
Clean your sensors with steel wool not sandpaper etc, if it needs something super abrasive it’s probably time to swap it.
@RC-Heli835
@RC-Heli835 7 ай бұрын
How do you like these package units man? I think I need one. The only downside I see is that your always out in the cold, snow and even rain possibly working on them. No one needs their heat worked on until you get records temp drops. Not always but sometimes right?
@TaddyDigest
@TaddyDigest 7 ай бұрын
I like package units But you can get higher efficiencies with split units plus the equipment last sometimes longer. They go out in the most extreme temperatures but not always
@RC-Heli835
@RC-Heli835 7 ай бұрын
@@TaddyDigest Well thanks for sharing man! Hey do heat limit switches to cut off the gas get power from the W terminal when using 24V? I have an old Honeywell fan limit switch. The fan side is stuck closed and the heat limit 24V side gets power from the Y terminal. That can't be right can it? the other end winds up at terminal 1 of the S86F igniter box where I am missing my 24 V to turn the gas on. This is an 86 model Rheem 11EAR-JR. Soon be knocking on 40 years old.
@mauriceshumock1869
@mauriceshumock1869 8 ай бұрын
Now I have questions like what’s the voltage that the control is sending? Is it looking for a specific resistance that a flame may provide? Could I test control integrity by disconnecting the female sensor terminal and putting it to ground right when the appears?
@TheRoland444
@TheRoland444 8 ай бұрын
No, the current must be solely in the micro-amp region----that is the actual voltage presented is alternating current, BUT the rectification process is only allowed when there is a flame- the flame basically acts as a low quality, but functioning nominally, diode where the positive versus the negative current is very slightly asymetric- that differential is the micro-amps read- the flame does create a resistance, but as a result of diode action difference in resistance (measured as micro-amps) between positive and negative alternation is perceived as the presence of a flame.
@mohmmadmohseni8404
@mohmmadmohseni8404 8 ай бұрын
Perfect 👍
@TaddyDigest
@TaddyDigest 8 ай бұрын
Glad you think so!
@Talentman18
@Talentman18 7 күн бұрын
What meter is that?
@philindeblanc
@philindeblanc 7 ай бұрын
Great video, yet that sensor is $40 vs others we use for $4bulk to $11,.... that wire must be very pricey ;-)
@TaddyDigest
@TaddyDigest 7 ай бұрын
Good point!
@forbiddenenigma4777
@forbiddenenigma4777 8 ай бұрын
i have a furnace that runs most of the day and shuts off ..usually in the morning ..it shuts off with my ac as well/ what can this be??
@peterevans8194
@peterevans8194 8 ай бұрын
Interesting video, and some obviously knowledgeable replies to the thread as well... Just a couple of quick questions re the testing...I understand that the wire from the FS could be faulty, hence why you tested between the FS and the board direct, but could you use the clamp to take a reading without disconnecting the wire? Or are the results from using the clamp meter not as accurate enough? Secondly, with the flame sensor disconnected/removed , if you hooked up the leads to your meter to the outputs directly and applied a flame from say a turbo lighter or small torch, would you expect to see an output?
@d.l.harrington4080
@d.l.harrington4080 8 ай бұрын
The clamp on meter is good for A/C but the flame sensor is very low D/C amps. This is called "Flame reification". His testing method is good.
@peterevans8194
@peterevans8194 8 ай бұрын
@@d.l.harrington4080 Thank you...I wasn't doubting the test method used, but rather trying to understand the limitations of the clamp meter....
@d.l.harrington4080
@d.l.harrington4080 8 ай бұрын
I didn't think you were. I wish it was that simple just to us a clamp on.@@peterevans8194
@TheRoland444
@TheRoland444 8 ай бұрын
clamp-on ammeter only good for AC current only- for DC ammeter the test instrument must be on the proper scale, in this case micro-amps AND wired IN SERIES by the test instrument (the ammeter function on the multimeter) @@peterevans8194
@chapmanmccollum6291
@chapmanmccollum6291 7 ай бұрын
Nicely done
@jon3862
@jon3862 8 ай бұрын
Hm Goodman I never see like this
@CRISTELRONACSERVICE
@CRISTELRONACSERVICE 8 ай бұрын
Hi dear Your video is awesome, I like it. By the way I am also a youtuber.
@CRISTELRONACSERVICE
@CRISTELRONACSERVICE 8 ай бұрын
kzbin.info/www/bejne/Z5Ozm5ttbdablbs
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thank you so much 🙂
@CRISTELRONACSERVICE
@CRISTELRONACSERVICE 8 ай бұрын
@@TaddyDigest youtube.com/@CRISTELRONACSERVICE?si=8KuMiMmHRur9FO0j
@myo3119
@myo3119 8 ай бұрын
i still think it was the board AND flame sensor. easy a $932.86 call 😋😈
@philindeblanc
@philindeblanc 7 ай бұрын
board $50 to 140, sensor maybe 10 ro 25, if its a tough location , maybe, but otherwise its a $150 labor.
@myo3119
@myo3119 7 ай бұрын
uuh! almost forgot, 5lb of freon (r22)… $300 a lb 😈
@fistinyourface78
@fistinyourface78 8 ай бұрын
Ted what state you in? Just curios that’s for your teachings
@TaddyDigest
@TaddyDigest 8 ай бұрын
Tennessee
@pandrosik
@pandrosik 8 ай бұрын
Short and sweet. Thanks
@hectormendoza993
@hectormendoza993 8 ай бұрын
Thanks for sharing your knowledge, great video
@Eddy63
@Eddy63 8 ай бұрын
Great little demo ... I have that same meter ... How do you like it ? Thx
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thanks for watching brother I love it my favorite meter so far.
@Kansas-Paul
@Kansas-Paul 8 ай бұрын
Most decent meters give you the ability to zero out the meter leads. I’d assume yours does also.
@melvinwillingham233
@melvinwillingham233 21 күн бұрын
You need to mention the wire is powered with ac voltage. Any where from 80 to 100 volts ac.
@karellfernandez73
@karellfernandez73 8 ай бұрын
Good video
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thanks
@2969566
@2969566 8 ай бұрын
👍
@chadrayl9648
@chadrayl9648 8 ай бұрын
Were you pulling the 24v wire off transformer to reset board?
@TaddyDigest
@TaddyDigest 8 ай бұрын
yes
@dporrasxtremeLS3
@dporrasxtremeLS3 8 ай бұрын
Thank you very Much Tad! Professional All the Way!
@TaddyDigest
@TaddyDigest 8 ай бұрын
Much appreciated!
@carvajal01
@carvajal01 8 ай бұрын
Thanks for show how you do....❤
@TaddyDigest
@TaddyDigest 8 ай бұрын
You're welcome
@920HVAC
@920HVAC 8 ай бұрын
Great video! 🤝
@TaddyDigest
@TaddyDigest 8 ай бұрын
Thanks! 👍
@mahabubulalamshusom6327
@mahabubulalamshusom6327 8 ай бұрын
Thanks for spreading your knowledge with the world @Taddy_Digest.
@TaddyDigest
@TaddyDigest 8 ай бұрын
You're welcome my friend that's what i'm here for
How Do Relays and Transformers Work in HVAC?
22:38
Taddy Digest
Рет қаралды 191 М.
Top 5 Furnace Problems and How to Fix Them
20:11
Word of Advice TV
Рет қаралды 1,4 МЛН
Spongebob ate Patrick 😱 #meme #spongebob #gmod
00:15
Mr. LoLo
Рет қаралды 17 МЛН
Please Help This Poor Boy 🙏
00:40
Alan Chikin Chow
Рет қаралды 15 МЛН
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 87 МЛН
WORLD BEST MAGIC SECRETS
00:50
MasomkaMagic
Рет қаралды 53 МЛН
Gas Furnace Turning Off? Here's What Might Be Happening
15:56
Taddy Digest
Рет қаралды 155 М.
How To PROPERLY Check A Furnace Flame Sensor | Goodman HVAC No Heat
8:01
Furnace Not Working - Troubleshooting the Flame Sensor
17:05
Word of Advice TV
Рет қаралды 343 М.
Flame sensor, Flame rod, Flame Rectification
9:53
Love2HVAC with Ty Branaman
Рет қаралды 55 М.
How to Test Pressure Switch on a Furnace
14:26
Word of Advice TV
Рет қаралды 613 М.
Customer Fired Other Company! Can I Figure This No Cooling Out?
18:25
Jeff’s HVAC Adventures
Рет қаралды 465 М.
A Simple Trick To See If Your Heat Exchanger Is Cracked.
11:56
The DIY HVAC Guy
Рет қаралды 381 М.
FLAME SENSOR   FLAME RECTIFICATION.  EXPLAINED .  TROUBLESHOOTING.
23:06
Alex The Handyman
Рет қаралды 7 М.
Spongebob ate Patrick 😱 #meme #spongebob #gmod
00:15
Mr. LoLo
Рет қаралды 17 МЛН