Taking a Look at the Orient Power 230Ah Server Rack Battery

  Рет қаралды 2,475

Adam De Lay

Adam De Lay

Күн бұрын

Join us as we dive into a review of the Orient Power 230Ah server rack battery. In this video, we'll explore its key specifications, conduct a discharge test, and examine its integration with both the EG4 6000XP inverter and the Victron system for optimal power management.
10% Off Discount Code: Adam
Note: the discount code will be valid for limited time.
Affiliate Link
------------------------------------
Orient Power 230Ah Battery - www.opsolarbattery.com/produc...
Supporting the Channel
--------------------------------------------------
There are several ways that you can help support this channel.
- Affiliate links help the channel by providing me with a small commission of the sale. It does not change the cost for you at all.
- The 'Buy me a Coffee' - link is here (on the bottom, right corner of the website): going-off-grid.com
- You can also click on the "Thanks" button under the video to support the channel.
Thank you for your support!
For more information, please check out my website with links to all the components, materials and products I have used in developing my off-grid solar system: going-off-grid.com
Chapters
--------------------------------------------------
0:00 What's in the Box
1:13 Intro
2:19 Specs
5:30 Discharge Test
7:22 What's Inside
11:16 Discharge Test Observation
12:04 Communication with EG4 6000XP
14:54 Communication with Victron Environment
17:31 Final Thoug & Wrap Up
#offgrid #solar #diy #solarproject #orientpower
*** Disclaimer ***
Please remember, I'm just a DIYer like you. Don't take what I'm doing as gospel truth, it's just how I'm doing things. If you're unsure of how to do something, look into hiring a professional or at least consult with a professional to determine the correct way to do things.

Пікірлер: 53
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
10% Off Discount Code: Adam Note: the discount code will be valid for limited time. Affiliate Link ------------------------------------ Orient Power 230Ah Battery - www.opsolarbattery.com/product-page/48V200AH?ref=going-off-grid
@GavinStoneDIY
@GavinStoneDIY 2 ай бұрын
I like their wire management design on this battery. I’d say that one cell will right itself soon enough. If you charge the pack up to 57v or so and keep it there for a while, that will likely help.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
That's kinda what I'm hoping.
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
You have a good understanding of batteries👍
@powerwall
@powerwall 2 ай бұрын
Get one for testing?
@leeshively669
@leeshively669 2 ай бұрын
Nice review, glad to see you adding some capacity, I have 2 of thier 100ah and they both show over 100ah full cap, have worked well for over a year.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Thanks Lee! Glad to hear their 100Ah batteries are working well for you!
@Mkiepert
@Mkiepert 2 ай бұрын
Thank you for the video, Adam. Alway’s enjoy how detailed you are.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
I appreciate that! Thank you!
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
The video is very detailed. Worth like👍
@Roll2Videos
@Roll2Videos 2 ай бұрын
Wow, Great job. I have a 230Ah server rack and could barely lift it from the ground to the back of my truck alone. It is a great video covering the communication with different inverters. Thanks
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Thanks! Things a beast!
@alanblyde8502
@alanblyde8502 2 ай бұрын
We have one of those albeit a 100ah I replaced the bms to a JK-bms and a Peter board (info on Andy’s off grid) So much info from the battery and control of balancing also integrated into home assistant, reason was so I can remotely monitor in detail the battery working a treat, they are a great battery even with the pace bms.
@JMS7410-
@JMS7410- 2 ай бұрын
Hey Adam, hope all is well! Long time haha - glad to see you're still pushing the community further. I am still rocking the dual Victrons and DIY 48V/280AH battery pack as a standby basement power source...been killer but fortunately (or unfortunately cause I really wanna test it out lol) havent needed it often since installing this time last year.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Yeah it has been a while! Like yours, my Victron system has been running strong and steady! Some additional capacity might help adding some more loads...we'll see. Sounds like you need to just flip the switch and run off the Victron full-time. Just let the system decide if it needs to switch back to grid power.
@JMS7410-
@JMS7410- 2 ай бұрын
@@AdamDeLay07 haha I would but the system is charged monthly via grid - it only cycles once a month and stays in float down to about 70%. Solar panels to keep it going 24/7 in MD are still nuts compared to other places. My goal is to transition this system to the future house as a detach garage or carport solar/battery charging for plug-in hybrid/EV and have a proper solar system professionally installed and ground mounted for the house.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
@@JMS7410- Gotcha. Yeah, I understand all to well about how expensive solar panels are...plus you have to have the real-estate to put them up. At least you have something ready for those warm-weather storms!
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
You can take 1 as a standard reference for DIY project.
@kennedymallery665
@kennedymallery665 2 ай бұрын
Damn! Batteries are getting huge these days!!
@tiborchren
@tiborchren 2 ай бұрын
I like big breaker, double terminals and overall build quality. The only thing I would replace is the PACE BMS with the new JK Inverter BMS - the communication boards are the same, probably the balance connectors are the same too, it would need to solve the BMS mounting with internal BMS wiring and who would want to solve the holes and mounting of a small or larger JK display.
@EastLondonKiwi
@EastLondonKiwi 21 күн бұрын
I like this battery build its very clean, and great value for money. I am howver, not a fan of the Pace BMS. I have two Rosen Solar Batteries here which also use Pace BMS' and thier cells get out of ballance constantly. I am in fact about to upgrade the BMS' to the JK Inverter BMS' which have 2amp active balancers built in to solve the issue I have had with my Rosen batteries. One note on the DIP switch settings of the PaceBMS, when you only have 1 battery installed, you can set the Dip switch to any value, it makes no difference. However if you have two or more PaceBMS' in parrarel, the master battery has to be set to zero (all DIp switches off) and each slave set to any other uneque value. Also the RS485 of the internal battery communications (the two most right ports) the Master to the first slave goes from port1 on the master to port0 on the slave (port0 on the master must be empty), then if you have a 2nd slave you go port1 on slave1 to port0 on slave2 etc (for a maximum of 16 batteries in parrell). if you get this setup wrong, nothing communicates properly. Also beaware in a parrareled situation the Cebro GX only communicates with the Master BMS, the settings in the slave BMS' have no impact on charging or discharging. I hope that helps take care Duncan
@DannyCsaszar
@DannyCsaszar 2 ай бұрын
Another great video :) I had a 8 cell battery that one battery constantly reached an earlier discharge point compared to the others. I found out that that one cell was 10ah lower than the bank. I had to Charge each cell to 3.5 and then it was balanced. This could be what is causing the under capacity you are getting.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Thanks! That's interesting. I'll have to take a look at that!
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
It comes from your experience. That's a good reminder.
@simon359
@simon359 2 ай бұрын
Nice review as always! As somebody who uses Victron equipment and different battery manufactures for multiple battery banks on the same system. My question is, are you checking all your batteries using separate Victron shunts like I do? I’ve tried inputting my 300 amp hours, 200 from the Battle Born Batteries and 100 from the SOK batteries. Unfortunately they don’t seem to show up properly on my Victron Quattro 5000. It doesn’t seem much of a problem when it goes to zero on the amp hours reading on the inverter, because I guess it’s using the Victron shunts for that. Perhaps you don’t have multiple battery banks?
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Thanks! No I only have the one shunt. I may use the battery communications just to "see" the other packs in the VRM but I'll use the shunt as the end-all SOC value. This is my first non-DIY battery pack that I've added to my system.
@seanyiya
@seanyiya 2 ай бұрын
EG4 wall mount indoor battery is about the same price but much better looking form factor.
@YeOldeTraveller
@YeOldeTraveller 2 ай бұрын
Great content. I might use this in a business where I have a chassis jack I can use. At home, I will stick to 100 pounds or less. I twitch when I see rings around active components. I've been bitten a few times with hot (both senses) surfaces.
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
OMG!You should pay attention to safety when using it.
@Raphael_Hofmann
@Raphael_Hofmann 2 ай бұрын
Yea, might be just one cell with less capacity...usually those cells should be capacity mached...but when they come back together on a full charge, there is now issue, using that battery for 10+ years
@agtcovert
@agtcovert 2 ай бұрын
Ahh, taking the plastic off a screen/controls. Total ASMR moment.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Such a good feeling! 😄
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
Aha, you are very enjoy the process of video.
@herbertvonsauerkrautunterh2513
@herbertvonsauerkrautunterh2513 28 күн бұрын
I have 4 of the 100ah batteries. I might sell them an switch to these
@boomermatic6035
@boomermatic6035 2 ай бұрын
The weight is the only downside I see; 100lbs is the about the max for me, anything more than that it gets challenging to move it around and even more dangerous if dropped.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Yeah, depending on where you have to put the battery, it can be difficult to move around. A dolly works great if you can keep it on the ground but if you have to lift it up, it gets troublesome.
@ThePonderi
@ThePonderi 2 ай бұрын
50A recommended charge current is too low why? That's like charging a lead acid battery usual 0.2C
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
I've actually seen a lot of these server rack style batteries "recommend" .2C as the standard charge rate. I'm assuming the thinking is that less charging stress will lengthen it's lifetime? Just a guess though. Ultimately if you have multiple batteries in parallel, the charge current is spread across all of them so it's less of an issue.
@retrozmachine1189
@retrozmachine1189 2 ай бұрын
@@AdamDeLay07 That's it exactly - extending the life of the battery. It doesn't mean you can't charge with higher currents, just that you be pushing towards the nominal lifespan of the battery as you get to the recommended max which is usually 50% and eating into the nominal lifespan if you do higher than that. It's part of the reason we see the quite high cycle life on many cells these days, that and of course deception and outright lies in the cheapies.
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
@@retrozmachine1189 Thanks for confirming!
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
@@retrozmachine1189 Great science of battery use tips!
@powerwall
@powerwall 2 ай бұрын
0.2C-1C is all ok. But suggested 0.2C if it is not hurry
@2hotscottpro
@2hotscottpro 2 ай бұрын
I have 4 12v 230ah bats wired 48v.There 45 lbs each
@2hotscottpro
@2hotscottpro 2 ай бұрын
They weren’t $3k OUCH
@slugbyte
@slugbyte 2 ай бұрын
Good review, sounds like you need to pump some iron 😂
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Thanks! I'll just start bench pressing batteries...🤣
@serverrackbatteryusa
@serverrackbatteryusa 2 ай бұрын
LOL!
@computersales
@computersales 2 ай бұрын
Being able to run my rack for 11 hours off grid would be amusing but probably not practical. 😅
@AdamDeLay07
@AdamDeLay07 2 ай бұрын
Guess it depends on if it’s mission critical or not… 😁
@slimanus8m
@slimanus8m 2 ай бұрын
Dude, bruh...you really need another person to handle this mf, you gonna hurt yourself
Installation & First Impressions of the NHX-10 Hybrid Inverter
25:17
New JK Inverter BMS Review + Test with Sunsynk Inverter
18:23
Grant Burton
Рет қаралды 7 М.
The day of the sea 🌊 🤣❤️ #demariki
00:22
Demariki
Рет қаралды 88 МЛН
1❤️#thankyou #shorts
00:21
あみか部
Рет қаралды 88 МЛН
How This New Heat Pump is Genius
18:03
Undecided with Matt Ferrell
Рет қаралды 770 М.
Is Bigger Better?  230Ah, 11,776Wh, Server Rack Battery
20:41
DavidPoz
Рет қаралды 87 М.
LFP Rack Battery Buyer's Guide, Comparisons and Things to Consider
10:08
Check Out My Rack!
15:13
Greg Salazar
Рет қаралды 47 М.
Going Over the Settings for the EG4 6000XP
22:02
Adam De Lay
Рет қаралды 3,7 М.
The Only Batteries I would Install in a Skoolie, RV, or Van
12:24
Mobile Dwellings
Рет қаралды 6 М.
Installed THE BEST New Home Battery Storage!
10:05
WHAT'S INSIDE? FAMILY
Рет қаралды 384 М.
The Truth about EV Battery Life and Charging Best Practice ! | 4K
23:46
SmartShunt vs BMV-712 vs Lynx Shunt
9:11
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 97 М.
Hisense Official Flagship Store Hisense is the champion What is going on?
0:11
Special Effects Funny 44
Рет қаралды 2,2 МЛН
1$ vs 500$ ВИРТУАЛЬНАЯ РЕАЛЬНОСТЬ !
23:20
GoldenBurst
Рет қаралды 1,3 МЛН