Today As An Electrician: 3 Phase Transformer Install (480 Volts)

  Рет қаралды 101,270

DailyElectrician

DailyElectrician

Күн бұрын

More Things About Me
linktr.ee/Dail...
Instagram
/ dailyelectricianyt
---------------------------------------------------
Channel Playlists
/ dailyelectrician
╔═╦╗╔╦╗╔═╦═╦╦╦╦╗╔═╗
║╚╣║║║╚╣╚╣╔╣╔╣║╚╣═╣
╠╗║╚╝║║╠╗║╚╣║║║║║═╣
╚═╩══╩═╩═╩═╩╝╚╩═╩═╝

Пікірлер: 92
@jamesreyes8555
@jamesreyes8555 4 жыл бұрын
Ground bushing with the lay in lugs in your transformer.
@isaiahmowery300
@isaiahmowery300 4 жыл бұрын
Love the channel and the daily vids .... I’m a junior in high school taking 4 electrical classes and in 2 years ima test for my journeyman’s and this videos have a lot of things I see in my daily scenarios so thanks a lot
@waterdown1826
@waterdown1826 3 жыл бұрын
Depending were you from your state requires certain work hours like 5,000 or 12,000
@baddleboose
@baddleboose 7 ай бұрын
did you get your journeymans yet?
@zhumusic-ng9tr
@zhumusic-ng9tr 2 ай бұрын
You need hours in the field... experience to get a journeyman. You can't just go test for one lol
@isaiahmowery300
@isaiahmowery300 2 ай бұрын
@@zhumusic-ng9tr wrong about that good sir. Changes state to state. I’m in West Virginia. In wv when your in high school there are several exams and if you pass those it qualifies for your 2000 needed on the job hours then you can test for your journeyman electrician license. The WV Governor did away with the apprentice license.
@isaiahmowery300
@isaiahmowery300 2 ай бұрын
@@baddleboose sure did man may of last year
@PWingert1966
@PWingert1966 Ай бұрын
They just put a massive solar panel array on the roof of our apartment building and they are using a 10 Kv transformer to facilitate the connection to the buildings transformer at 600V for a feed through back to the grid. Once the installation is paid off the social housing provider will get the profits from feeding thought the power from the panels. Contractor did t it as a upfront zero cost installation. I think they have 40 or 50 650W panels on the roof (Biggest I've ever seen by spec). They have a remote access solar monitor as well that is performing some control functions since we don't have a solar controller (more power then most off the shelf units are designed for) they sub the transformer in for the power management and the solar monitor does the rest.
@koarivera9151
@koarivera9151 3 жыл бұрын
That's what a good electrician does fix other people's problems that's why they pay us the big bucks
@DailyElectrician
@DailyElectrician 3 жыл бұрын
lol
@TheDakotaFrazier
@TheDakotaFrazier 11 ай бұрын
We don’t get paid big bucks where I’m at :(
@RationalPhyco666
@RationalPhyco666 2 жыл бұрын
I'm installing a 3phase transformer tomorrow and your vid helped me prep 👍🏽 thanks man
@deltaanderson5255
@deltaanderson5255 2 жыл бұрын
Bro, don't let it getcha down. I've made a living fixing people's f ups. It's been paying my bills since 1988. One thing about it, you got job security...
@No5elfCTRL
@No5elfCTRL 3 жыл бұрын
Cool how they mount a bracket with a Wago screwdriver on it to the back panel if you need to do anything. Kinda like the fuse removal tool in the fuse box of you car
@liamczarnecki3275
@liamczarnecki3275 3 жыл бұрын
You can stick a tweaker in that small hole and the cabinet will open live
@stans5208
@stans5208 2 жыл бұрын
Looks like a temporary job. All that greenfield.
@DailyElectrician
@DailyElectrician 2 жыл бұрын
nope, permanant. For an elevator.
@slant757
@slant757 7 ай бұрын
Personally I would have used insulated metallic grounding bushings in both the disconnect (considering it's 3 Phase) as well as the TRANSFORMER. And it looks like the load out side to the TRANSFORMER has no bushings at all.
@michoelmushinsky922
@michoelmushinsky922 6 ай бұрын
The point of a Metallic Insulated Ground Bushing (MIGB) is to bond the metallic raceway (pipe or flex) to the equipment. It is designed to be used where the knockout isn't full, and you have bigger knockouts around it (incase it breaks off, it will still be bonded via the ground wire on the MIGB.) Also, it is only required when unfused wires are incoming. They seem to be fused here.
@grandmasterbriggiddy
@grandmasterbriggiddy 3 жыл бұрын
Why you pissed if you’re getting paid? I love getting paid for fixing other people’s fuckups.
@rafalszachnowicz2831
@rafalszachnowicz2831 2 жыл бұрын
There is not much - no explanation of what goes where and why. A lot of talking about unfinished job. Why? Just don't waste my time. At least inform the viewer there is a lot about everything but nothing concrete.
@DailyElectrician
@DailyElectrician 2 жыл бұрын
its a vlog not an install video. 🤷🏻‍♂️
@AmericanWireman
@AmericanWireman 3 жыл бұрын
Is the transformer bonded my guy
@adamdemartinis72
@adamdemartinis72 3 жыл бұрын
Right? Didn’t see a Kenny clamp or a bonding bushing
@arhodehamel2615
@arhodehamel2615 3 жыл бұрын
@@adamdemartinis72 I see no SBJ in this video. Does he need a bonding bushing on the flex? With drilled hole (no KO cut outs) and listed fitting?
@popcat_roblox24
@popcat_roblox24 Жыл бұрын
Wouldn’t drywall screws penetrate the panels
@jake_dev1046
@jake_dev1046 3 жыл бұрын
My transformer panel exploded lol
@DailyElectrician
@DailyElectrician 3 жыл бұрын
yikes!
@jake_dev1046
@jake_dev1046 3 жыл бұрын
@@DailyElectrician yep massive yikes im getting it replaced soon
@DailyElectrician
@DailyElectrician 3 жыл бұрын
thats good 🙌🏼
@adamdemartinis72
@adamdemartinis72 3 жыл бұрын
Too much flex. Emt then transition to greenfield. Looks good tho
@DailyElectrician
@DailyElectrician 3 жыл бұрын
i just do what im told :) thanks
@gw4411
@gw4411 3 жыл бұрын
Feed underground like the pros do.
@gw4411
@gw4411 3 жыл бұрын
Got box brackets supporting panels in stud lmmfaoooo. Damn son
@DailyElectrician
@DailyElectrician 3 жыл бұрын
in a parking garage 8" slab? k lol
@whophead6837
@whophead6837 3 жыл бұрын
I came to say the same thing.
@robertmartin5167
@robertmartin5167 Жыл бұрын
There no bonding bushing in the fransformer. Or in the disconnect
@DailyElectrician
@DailyElectrician Жыл бұрын
I'm aware 🙂
@robertbarron7995
@robertbarron7995 4 жыл бұрын
Good shit bro!
@DailyElectrician
@DailyElectrician 3 жыл бұрын
thanks!
@Tayjay7175
@Tayjay7175 2 ай бұрын
No cussing
@RRaucina
@RRaucina 2 жыл бұрын
I need to step up 240v single phase to 480v single phase for a long run up a mountain on my property. And then a step down unit back to 240/120. I have a 15kva step down unit single phase, but locating a 240v to 480 step up has been difficult. Can one use a three phase unit and use 2 phases? Thanks for any input
@DailyElectrician
@DailyElectrician 2 жыл бұрын
i think i've seen a friend do it once but im not sure on the specifics on how he did it. hope this helps
@armondmoore314
@armondmoore314 2 жыл бұрын
If you’re running it 480 just because the voltage drop that is unnecessary. You could use a buck-boost transformer to compensate for that vd.
@fnhwk
@fnhwk Жыл бұрын
Please hire a licensed electrician.
@ricardovillarreal1091
@ricardovillarreal1091 3 жыл бұрын
forgot the grounding bushing
@DailyElectrician
@DailyElectrician 3 жыл бұрын
i didnt
@blakes.8750
@blakes.8750 3 жыл бұрын
Have you heard of EMT? Flex is the lazy way!!
@DailyElectrician
@DailyElectrician 3 жыл бұрын
have you heard of following instructions??
@DS-fe7hb
@DS-fe7hb 3 жыл бұрын
Transformers vibrate. Think about that for a few minutes
@OfficialTakGiovanni
@OfficialTakGiovanni Жыл бұрын
@@DailyElectricianlol facts whatever is in the specs you gotta obey
@DailyElectrician
@DailyElectrician Жыл бұрын
that too, just doing what my boss wanted tho. both are important to follow 😋
@IanStone-ko7pz
@IanStone-ko7pz Жыл бұрын
Drink every time he says "Umm"
@DailyElectrician
@DailyElectrician Жыл бұрын
umm
@ОляПолякова-х4с
@ОляПолякова-х4с 2 жыл бұрын
Good!
@DailyElectrician
@DailyElectrician 2 жыл бұрын
Thanks
@earleclemans4836
@earleclemans4836 3 жыл бұрын
No worries it all pays the same
@isaacjansson5291
@isaacjansson5291 3 жыл бұрын
no offence but all that flex looks like dog💩. why not pipe from the panel and change over to flex close to the transformer?
@DailyElectrician
@DailyElectrician 3 жыл бұрын
what the foreman wanted.
@hehasrisen8521
@hehasrisen8521 3 жыл бұрын
By code you can’t use more then 6 feet flex.
@DailyElectrician
@DailyElectrician 3 жыл бұрын
thats not more than 6 feet :)
@jimmycrackcorn1667
@jimmycrackcorn1667 2 жыл бұрын
Unless your AHJ says otherwise, I'd look back at the NEC there, guy.
@DailyElectrician
@DailyElectrician 2 жыл бұрын
appreciate that, just following what the boss wanted. ya know?
@jamesladd
@jamesladd Жыл бұрын
You can strap it every 31/2 feet
@MillsElectric
@MillsElectric Жыл бұрын
@@jimmycrackcorn1667 Sure the inspector may feel generous and pass you, but since you’re trying to get technical, the AHJ does not allow the inspector to pass an install that’s not up to code. It gives he or she the authority to go beyond the minimum requirements which is the NEC. I think you’re the one that should look back at the NEC. If that inspector is caught passing installations that doesn’t meet the minimum requirements knowingly by their supervisor he or she will be reprimanded.
@faturfatur9027
@faturfatur9027 Жыл бұрын
So, conection transformer step up star to delta ?
@jmoneill3
@jmoneill3 4 жыл бұрын
Who’s going to fix all that flex? Where’s your grounding bushing on the primary side?
@DailyElectrician
@DailyElectrician 4 жыл бұрын
whats there to fix about the flex? i'll look into the bushing
@cheynebest7028
@cheynebest7028 3 жыл бұрын
Plastic bushings aswell on one inch emt with wire equal or greater then #8 awg... atleast thats code in canada
@muneer6
@muneer6 3 жыл бұрын
No connection shown.
@DailyElectrician
@DailyElectrician 3 жыл бұрын
ok
@psyo123
@psyo123 4 жыл бұрын
wondering the reason why you used #10 wire for transformer but thx for sharing. btw don't forget the bushing with grounding terminal. I experienced so many inspectors obsessed with it
@DailyElectrician
@DailyElectrician 4 жыл бұрын
#10 is good enough for the amps it's sending out. thanks, i'll look into the bushing
@derekevans7780
@derekevans7780 3 жыл бұрын
Higher the voltage the lower the amps.
@BronxGummer
@BronxGummer 3 жыл бұрын
Hack Job - not his fault because Nick did most of the job.
@w4lkoff502
@w4lkoff502 3 жыл бұрын
Hey man I’m thinking of becoming a electrician out of HS. How physically demanding is it? Like am I gonna be having joint problems down the line or am I fine as long as I’m in decent shape? Also what should I know before hand before becoming a electrician cuz rn I really don’t know anything but the field interest me. Also I hear I should know algebra and reading comprehension for the test I have to take for a license?
@eddiew2325
@eddiew2325 3 жыл бұрын
Anyone with a pulse can be an electrician
@gm8507
@gm8507 3 жыл бұрын
@@eddiew2325 depends which company, the company I work at fires and hires alot.
@desertoutlaw3317
@desertoutlaw3317 2 жыл бұрын
@@eddiew2325 lmao not true at all
@DailyElectrician
@DailyElectrician 2 жыл бұрын
not too demanding once you move up, but not the worst as an apprentice. you can take preventative measures to be safer and do less wear on your body. you dont need to know anything before hand but it would help. just need to know algebra
@deltaanderson5255
@deltaanderson5255 2 жыл бұрын
Algebra sure, Bending conduit involves trigonometry. Is being an electrician hard on the body? Sure, but really living is even harder Be safe, have fun, go hard...
@mistertruth8001
@mistertruth8001 Жыл бұрын
Sizing? You didn't discuss sizing and calculations?
@DailyElectrician
@DailyElectrician Жыл бұрын
This is just a video of me discussing what I did at work, not a tutorial :)
@thomaswestfall745
@thomaswestfall745 2 жыл бұрын
Ó
@DailyElectrician
@DailyElectrician 2 жыл бұрын
:)
@brendanwilliamson127
@brendanwilliamson127 3 ай бұрын
Wow its like your super glad to be someones apprentice and not know shit about electrical.
@DailyElectrician
@DailyElectrician 3 ай бұрын
just good at doing what i'm told
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
Is that transformer reversible 220 three phase in and can get out 480 volts three phase out please let me know thanks
Delta to Wye Standard 3 Phase Transformer Connections
13:16
Pete Vree
Рет қаралды 39 М.
15 Minute Tech Talk - 75 kVA Transformer
27:36
Thomas Domitrovich
Рет қаралды 41 М.
Inside Out 2: BABY JOY VS SHIN SONIC 3
00:19
AnythingAlexia
Рет қаралды 6 МЛН
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17
когда не обедаешь в школе // EVA mash
00:57
EVA mash
Рет қаралды 1,2 МЛН
Instalación de Paneles eléctricos 480 y 208 V.
44:01
Mateo Leal
Рет қаралды 152 М.
Installing 3 phase transformer | Starting a Machine Shop 17
12:09
Erik Cortina
Рет қаралды 43 М.
100 Days of Article 100: Separately Derived System
7:15
Ryan Jackson
Рет қаралды 25 М.
Today As An Electrician: 480 Volt 3 Phase Transformer
8:15
DailyElectrician
Рет қаралды 71 М.
How to wire a 480 Volt to 120 Volt Transformer?
14:24
Taddy Digest
Рет қаралды 7 М.
How To Hookup 30kva Step-Down Transformer  #electrician #electrical
6:59
Adventurous DIY Guy
Рет қаралды 12 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,4 МЛН
How three phase math works (277 + 277 = 480?)
8:48
The Electric Academy
Рет қаралды 355 М.
Inside Out 2: BABY JOY VS SHIN SONIC 3
00:19
AnythingAlexia
Рет қаралды 6 МЛН