Treadmill Board Repair : Failed Power MOSFET

  Рет қаралды 64,559

Biomed Life and Story

Biomed Life and Story

3 жыл бұрын

This video shows how to repair a treadmill board and replaced a defective components.

Пікірлер: 73
@pittsville21850
@pittsville21850 2 жыл бұрын
That is not capacitor leakage. It is some kind of adhesive they use to hold the caps in place.
@vibsosu
@vibsosu 10 ай бұрын
NOTE: This product works exactly as described. kzbin.infoUgkxguEIMc_Qwab-3QMTpF6jaRL80hiOOsIN It originally earned a four-star review due to a minor defect (see below). However, the manufacturer's customer service rep (Lita) went above and beyond the call of duty and deserves five stars now. I wish I could give even more!I purchased this item which arrived quickly. Assembly instructions were easy to follow. There was only one problem: One bolt did not screw into the hole properly. I called the company. Their customer service rep (Lita) was terrific! She took all my information and submitted a request to replace the defective part. I'm hoping to finish assembly and start using this treadmill soon. (Fingers crossed...)FOLLOW UP: Lita called back to inform me that the company will send a replacement part AND a technician(!!) to install it properly. AMAZING CUSTOMER SERVICE!! Thank you!!
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 10 ай бұрын
Great to hear!
@chard91sportsflix28
@chard91sportsflix28 3 жыл бұрын
This is very helpful to me. 👍🏻
@jed2055
@jed2055 2 жыл бұрын
The board in mine also has bad staining but capacitors look okay. Staining looks very old on this board. Maybe previous bad caps been replaced on my board. Did you match the bad mosfet or go with something close? Thanks for the video, it was interesting.
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
How to Check a Capacitor? Check my previous video. kzbin.info/www/bejne/rJK9ZHisrZ2jpcU
@HTMWorkshop
@HTMWorkshop 3 жыл бұрын
Nice video!
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks...more power..👍
@kaletsugas
@kaletsugas Жыл бұрын
It's not a capacitor stain. It's an adhesive to hold the capacitor in place.
@anganwadi55
@anganwadi55 Жыл бұрын
Philippine technician is the number one..
@sa_gravity
@sa_gravity 2 жыл бұрын
This is my type of treadmill and I might have switch the cables in wrong places on the motherboard after cleaning. Please I need a proper connection video of this very treadmill.
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Check my previous video how to check a mosfet kzbin.info/www/bejne/eWitpIB6gqyGZ7M
@domenicopascuzzo1361
@domenicopascuzzo1361 3 ай бұрын
Sir Thank you for your videos very good knowledge I have a sole f80 treadmill and it made a short on the negative ac to the relay pin that is on the reverse on the board where can I send you a picture?
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 ай бұрын
That's tricky. If it's connected to relay your multimeter will read it as short because of the relay coil. Remove it from the board and test again.
@fixnreview
@fixnreview 3 жыл бұрын
Watching from Ormoc City
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thnaks for watching
@fixnreview
@fixnreview 3 жыл бұрын
@@biomedicalelectronicsengin7192 welcome sir
@faackthewef
@faackthewef Жыл бұрын
Hi thanks for the video. What would cause the fuse on the pc board to blow when switched on?
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Check shorted bridge rectifier
@faackthewef
@faackthewef Жыл бұрын
@@biomedicalelectronicsengin7192 Thankyou for your advice👍
@tricksandfix6374
@tricksandfix6374 3 жыл бұрын
Watching Master, bagong kaibigan
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks for watching
@jnvtechelectronicstv2704
@jnvtechelectronicstv2704 3 жыл бұрын
ayos master power mosfet pala ang defect
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks bro.
@yut9798
@yut9798 Жыл бұрын
Hey man, what causes the mosfet to die out when I put weight on my treadmill?
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
What do you mean? Check flyback diode
@treadmillrepair754
@treadmillrepair754 Жыл бұрын
Mosfet can fail for some reasons. 1 Bad quality of the new transistor 2 over current, motor can be failed. 3 belt, deck or both. You need a clamp meter for test the current, if the machine works for 120 volts current never exceds the 13 amps. Using a infrared thermometer you can test the temp of the belt, never be more than 45 Celsius degrees in the contact point. Best Regards.
@DjJohnRoldRemix
@DjJohnRoldRemix 3 жыл бұрын
Nice bro
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks
@LuckydogMultimedia
@LuckydogMultimedia 2 жыл бұрын
Sir do you accept repair jobs? I'm from Marikina.
@nitinadhav9719
@nitinadhav9719 Жыл бұрын
Nice
@MORJOYES
@MORJOYES Жыл бұрын
Hi very informative. I changed the mosfet to my treadmill because was shoryted ansd as soon I started the treadmill it got shorted again do you know what is the cause in the board
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Try to start without connecting the motor. If there is flyback diode check it if short. It is parallel to the motor connected to the MOSFET.
@MORJOYES
@MORJOYES Жыл бұрын
@@biomedicalelectronicsengin7192 thank you for your fast respond, I do not know anything about electronics and how to check for a shorted flyback diode. do you have a video of how to? I changed the mosfet second time and removed the Treadmill Motor Belt and run the treadmill with the new mosfet and this time did not blow up the mosfet but as soom I installed the motor belt again and run the treadmill and this time it did blow up the mosfet again. the treadmill walking belt its find. it does not fill hard to turn. its fill free.
@antibobo4706
@antibobo4706 Жыл бұрын
@@MORJOYES a flyback diode is just an ordinary diode. In some of my video it shows how to check a diode. Similar way you check the bridge rectifier. After you replace the mosfet remove the motor connection not the belt. If connecting the motor again and blows the mosfet then you have a problem with the motor.
@MORJOYES
@MORJOYES Жыл бұрын
@@biomedicalelectronicsengin7192 I have a treadmill board Nordictrack A2250
@aesop57jay
@aesop57jay 2 жыл бұрын
E6 error ba yan sir usually MOSFET Ang cra?
@ashishshinde6374
@ashishshinde6374 Жыл бұрын
If this MOSFET is short then does the fuse gets blown...plzz reply...
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Usually no. Depends on the circuit. Short bridge rectifier will blow the fuse.
@roseelectronics4582
@roseelectronics4582 3 жыл бұрын
I found your channel recently, and I like what you're doing. My dream is to become a biomedical equipment technician but training is not available in my country, Maldives. Can you give me some training providers name from Philippines? I prefer short term training programs over year long ones. Any help would be generously appreciated.
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
I think your country is near to India. They have a lot of programs their for biomed. But due to covid cases in India, it will be very difficult to train their. My advice is try to apply for a job in hospital or company that sell and provide service for medical equipment. They usually have their own training program. There's a lot of medical equipment and its impossible to be train for all of them. Choose your field like diagnostic, life support or monitoring. The best training is always from the manufacturer.
@roseelectronics4582
@roseelectronics4582 3 жыл бұрын
@@biomedicalelectronicsengin7192 Thank you for the advice. It's really helpful. I'll keep an eye on your videos.
@kentcumberland2216
@kentcumberland2216 7 ай бұрын
I need your helpful advice, sir. I have ct9.3 horizon folding treadmill. It suddenly stops and a clicking sound starts coming from the motor control board. Then it takes long time to reset itself automatically and again stops and same clicking sound starts coming from the control board. What can be problem and what do you advise to fix it. Thanks.
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 6 ай бұрын
The clicking sound might be coming from the relay. It will be tricky you need to test the components on the board
@kentcumberland2216
@kentcumberland2216 6 ай бұрын
@@biomedicalelectronicsengin7192 Thanks for the suggestion. I will see if that will be cost effective.
@rraakkiibb1
@rraakkiibb1 3 ай бұрын
Hi boss, I have also same problem in my treadmill, many times I changed my Mosfet, few minutes work after replacing the Mosfet, and again stopped working. Please help me
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 ай бұрын
Did it damage the new MOSFET that you replaced?
@againosama
@againosama Жыл бұрын
👍
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Thanks
@mybikevlogs6670
@mybikevlogs6670 3 жыл бұрын
Watching
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks for watching
@waqasnettv3393
@waqasnettv3393 9 ай бұрын
I have also the same problem i changed the mosfet and machine is running but after 20 to 30 minutes again mosfet problem.3 times i have changed mosfit but it works only 20 to 30 minutes what i do?
@waqasnettv3393
@waqasnettv3393 9 ай бұрын
Mosfit number is Irfp460
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 9 ай бұрын
So everytime it stop working the MOSFET become defective?
@waqasnettv3393
@waqasnettv3393 6 ай бұрын
Yes every time mosfet problem
@sachinmahindrakar5663
@sachinmahindrakar5663 Жыл бұрын
My powermax treadmill MOSFET (30H60S 0H4) not work.pls give me the replace MOSFET no. because this one not available in Market.
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Download the component pinout app. You can check component replacement.
@rajaulkarim8335
@rajaulkarim8335 3 ай бұрын
Igbt replacement number need 0:48
@alirashid8543
@alirashid8543 Жыл бұрын
New card ki coast Kia he maximum.koi share kryga in Pakistan
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Sorry. I have no idea. I am based in Saudi Arabia
@markmelodheeescucharo8717
@markmelodheeescucharo8717 2 жыл бұрын
Sir yun saamin ganyan din..napalitan nman na po yung mosfet nya kaso ayaw pari gumana.ano pa kaya possible na sira?
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 2 жыл бұрын
Do voltage tracing. Check kung my enough power papunta sa motor. Check motor carbon brass and capacitor.
@markmelodheeescucharo8717
@markmelodheeescucharo8717 2 жыл бұрын
Minsan gumagawa siya sir tulad nung isang araw gumana den gagamitin na sana ng kapatid ko the same day ayaw nnman
@jorgetechofficial2368
@jorgetechofficial2368 3 жыл бұрын
Tinalo mo pa amg mga service center walang masasayang na unit
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 3 жыл бұрын
Thanks bro....more power and Godbless
@bumblebee8891
@bumblebee8891 2 жыл бұрын
Just a little info on high speed switching mosfets.Never use digital multimeter to test if mosfets are good or bad.Use analog multimeter to test switching of mosfets.🤗🤗
@OldSkoolF
@OldSkoolF Жыл бұрын
And what is your logic on this??? I've been using them since they came out in the late 70's... Thousands of repairs and I've never heard this...
@treadmillrepair754
@treadmillrepair754 Жыл бұрын
Analog multimeter in this time? What are yoy talking about?
@champspec
@champspec 9 ай бұрын
I think it has to do with the internal circuitry inside of the DMM. It will can give false readings depending on the orientation of the leads. This is just an educated guess
@abubakersiddique6322
@abubakersiddique6322 Жыл бұрын
Im your subscriber I have problem with treadmill can I watsapp u pix ??
@biomedicalelectronicsengin7192
@biomedicalelectronicsengin7192 Жыл бұрын
Could you please describe the problem
@akramkadhim9055
@akramkadhim9055 2 жыл бұрын
You don't explain nothing unfortunately... Which is which the pins of the MOSFET ....bad
@lesstime1678
@lesstime1678 2 жыл бұрын
don't repair ,,, buy new one ,,, the custom can not afford repairs , too many $$$$$$$$$ to repair
271 How to Repair Circuit for TreadMill - Circuit Explained /Troubleshooting
32:29
Treadmill not working?
9:17
Treadmill Heroes Fitness Repair and Delivery
Рет қаралды 692 М.
Василиса наняла личного массажиста 😂 #shorts
00:22
Денис Кукояка
Рет қаралды 10 МЛН
Must-have gadget for every toilet! 🤩 #gadget
00:27
GiGaZoom
Рет қаралды 12 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 14 МЛН
How To Repair Treadmill Control Board
13:04
TARIQ LAB
Рет қаралды 5 М.
Cara cek PCB dan DINAMO Treadmill
12:10
Abay tea
Рет қаралды 2 М.
Troubleshooting Treadmill Motor Control PCB
9:11
Better Biomed Channel
Рет қаралды 10 М.
Quick test for bad mosfets
4:42
Genetry Solar
Рет қаралды 108 М.
Sole Motor Control Board Troubleshooting
8:37
Fitness Technology Services
Рет қаралды 83 М.
Treadmill Starts Then Immediately Stops Try This.
7:38
Mr. Fixit
Рет қаралды 41 М.
🔴 Pro-form Endurance M7 Treadmill Repair - No.1048
27:43
Defpom's Electronics Repair
Рет қаралды 9 М.
Treadmill motor armature winding rotor winding treadmill repair
20:55
KRC KARACA ELEKTRİK BOBİNAJ
Рет қаралды 133 М.
Treadmills:  How to Swap the Circuit Breakers
1:59
XPlus Outdoor Inc
Рет қаралды 26 М.
ИГРОВОВЫЙ НОУТ ASUS ЗА 57 тысяч
25:33
Ремонтяш
Рет қаралды 331 М.
GamePad İle Bisiklet Yönetmek #shorts
0:26
Osman Kabadayı
Рет қаралды 513 М.
Что не так с яблоком Apple? #apple #macbook
0:38
Не шарю!
Рет қаралды 479 М.