Troubleshoot the oil furnace part 1. Burner won't start.

  Рет қаралды 993,104

grayfurnaceman

grayfurnaceman

Күн бұрын

Пікірлер: 404
@dec967
@dec967 9 жыл бұрын
I wanted to thank you for putting all the videos up about oil furnaces. I had some prior knowledge about them but thanks to you I am able to diagnose and repair ours in about half the time. We dont have alot of extra money so the knowledge you have given is valuable and the reason my family is warm tonight. THANK YOU AND GOD BLESS
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
Wayne Decker Its good to be warm. GFM
@wsomervell147
@wsomervell147 9 жыл бұрын
GFM You are the man! Oil boiler in my new house was super dirty and looks like it was never serviced at all. Followed these videos and disassembled by boiler assembly and cleaned each part and its working beautifully! Thanks!
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
+wsomervell147 Welcome GFM
@peterdhal
@peterdhal 7 жыл бұрын
Thank you for your videos. Furnace was down and repairmen are too busy right now , winter time and all. Wacthed the trouble shooting videos and got my furnace up and joining. Will have it serviced when the repairmen are not so busy. Your easy to understand videos saved the day and are greatly appreciated
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Merry Christmas GFM
@holdmeback47
@holdmeback47 6 жыл бұрын
thanks for your free help. It is so nice to have youtube help when you are all alone and have no one to help you.
@juniorpatao1
@juniorpatao1 3 жыл бұрын
this gentleman knows what you say is more important yet he knows how to explain thank you very much for your kindness I wish you all the best
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
Thanks for the support. GFM
@copykon
@copykon 3 жыл бұрын
I know this is an old video, but it helped me get my oil burner going tonight when the temperature outside hit zero. In my case, the oil pump seized. I took it apart and cleaned it when brake cleaner and pulled out the shaft and removed the rust deposit, then greased it up and put it back together. What I didn't know was the reset on the back side of the motor tripped. Thanks for sharing your knowledge.
@robertmartinez9984
@robertmartinez9984 10 жыл бұрын
this video just saved me probably hundreds of dollars. turned out it was the motor on mine. swapped it out and now it runs like new. and Ive never worked on a furnace before. if your ever in NY I owe you a beer. thanks
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Robert Martinez It could happen. GFM
@johnnypools6971
@johnnypools6971 5 жыл бұрын
I assess home repairs for an insurance company and your videos have helped a lot. Thanks for taking the time to put them up
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Welcome GFM
@nelsonkamerman7525
@nelsonkamerman7525 3 жыл бұрын
Thanks for the great videos. You are my favorite professor at KZbin university right now. 2 down oil furnaces on the farm up and running thanks to your tutelage.
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
Glad you got them going. GFM
@0118david
@0118david 6 жыл бұрын
Thank you very much, Mr. Gray. I follow your steps, my furnace wasn't working. Now is doing great. I save 400.00. Thank you for my Christmas gift with this information. Regards
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Welcome GFM
@2006breakmyballs
@2006breakmyballs 3 жыл бұрын
Thank you so much for posting all your videos! I've fixed my old oil furnace several times with your help. And after calling several companies that never showed up for appointments, I would probably still be freezing. Each repair usually cost me less than $20, when a visit for an estimate was quoted at $125.
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
Glad I could help. GFM
@joeminty
@joeminty 3 жыл бұрын
GFM, I just need to tell you your oil furnace troubleshooting steps have saved my family and I from freezing tonight and times before. I wanted to tell you how much I appreciate your knowledge and time spent making these videos. I had ran my tank dry and just got oil today but could not figure out why the gun was not getting fuel. I guess I needed to purge the air out of the pump and suddenly I had pressure at the gun again . If it wasn't for your tips I would not have heat tonight.
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
Its good to be warm. GFM
@taskforceviolent751
@taskforceviolent751 7 жыл бұрын
Thanks for the video! Came home to the indoor temp at 61 and the heat was set to 63. Thermostat would click on but the furnace never fired up. Cut power at the fuse box, opened the motor to rotate the blower (which rotated smooth), pressed the red button as mentioned in the beginning, flipped the breaker, turned on thermostat, and it fired right up.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Like is good. Hope it stays on. GFM
@beefyramos
@beefyramos 8 жыл бұрын
never mind. I found the problem. one of the contracts on the starter inside the control box is burnt off. thank you for putting so much information out there. it's an amazing resource.
@moegrimm
@moegrimm 10 жыл бұрын
Thank you for sharing your knowledge for free. I just fixed my oil burner because of you. I would have cost $300 dollars I did it for free. Thank you
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Glad you got it working. GFM
@renaegervalis7977
@renaegervalis7977 7 жыл бұрын
thanks for your video! our furnace started with watching your video and saved us some money...
@sophielemay4833
@sophielemay4833 6 жыл бұрын
Very helpful! Couldn't fix the problem myself because it turned out to be the cutout box, but at least I'd ruled out the basic stuff thanks to your video before calling for help. :)
@electriccar3253
@electriccar3253 6 жыл бұрын
Welcome GFM
@pattysherwood7091
@pattysherwood7091 3 жыл бұрын
I just watched a technician replace my motor. My reset button on the motor had popped. He said there was a dead spot in the motor and it couldn’t start when it hit that dead spot. I had heard a weird buzz earlier. I enjoyed watching this video. My new motor does not have a reset button. I wish it did.
@dbr6638
@dbr6638 7 жыл бұрын
Thank you!!!!! You just helped my husband trouble shoot and FIX our furnace!!!
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Welcome GFM
@michaelchandler8370
@michaelchandler8370 7 жыл бұрын
My reset button (almost black) was not as east to see as your demonstrator so I didn't think to look for it until I saw your video. I compliment your step by step process. I was prepared to replace the motor. I did have to free up the motor (the apparent cause of the reset tripping) and maybe the problem will reoccur, but I will not have to replace the motor this month.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Cross your fingers that it stays on. GFM
@goodkao
@goodkao 11 жыл бұрын
God bless you for all the videos you show us and God bless you for who you are. Thanks
@grayfurnaceman
@grayfurnaceman 11 жыл бұрын
Thanks for the support. GFM
@TheFirstgoldking
@TheFirstgoldking 10 жыл бұрын
Had a odd problem once..my furnaced worked fine +- then I had to push the motor reset in the morning then all was well till the next morning had to reset only once in morning after over night temp turned down..went to furnace store..great guy told me he had that problem once it was a weak button return spring? he said next time tap the control box with something..I did. It reset...but a new control box...experianced folks are great..thanks for videos sid
@lebo2542
@lebo2542 7 жыл бұрын
Great videos very well presented info. I'm in a mostly gas & propane area but was trying to help a friend in a mostly oil heat area. This should do the trick for him very well. Thanks so much. Mr Gray. There once was oil use in this area but it all died during the first oil shock in 1973.
@dandanzoo
@dandanzoo 8 жыл бұрын
it was the cad cell! a week without heat sucked! thank you so much!
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
+dandanzoo Welcome GFM
@yellowbe2003
@yellowbe2003 8 жыл бұрын
Hey thx Grayfurnaceman, your video helped me realize my problem instantly!!! lol. I was bleeding the line on my oil furnace, when the reset button stopped working on the 3rd try. I thought we were gonna need an entire new Honeywell primary ignition unit.......Unitil i remembered one of the 1st things you said..."turn the thermostat up". There was nothing wrong with the reset button, the furnace was ready to go and just waiting "our command". I usually remember that but, my brain was thinking the worst & how much this was going to cost to call in a "pro". THX again....& holy crap i hate winter.😠
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
I always set the thermostat up as high as it will go. Even then, the customer will sometimes change it while I am working on it. GFM
@yellowbe2003
@yellowbe2003 8 жыл бұрын
grayfurnaceman funny😠
@neilveloz7713
@neilveloz7713 9 жыл бұрын
Thank you for the step by step demonstration. It worked perfectly on my furnace.
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
+Neil Veloz Glad I could help. GFM
@kennymaggic6004
@kennymaggic6004 Жыл бұрын
great info, helped me with my issue, part 2 also.
@MrPiskak
@MrPiskak 9 жыл бұрын
Just found you on youtube, i'm trying to use a fuel oil burner to melt aluminium and you really provide an abundance of information. Thank you!
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
+Liquid Pie Merry Christmas GFM
@MrPiskak
@MrPiskak 9 жыл бұрын
+grayfurnaceman You too man!
@chrisirizarry3474
@chrisirizarry3474 2 жыл бұрын
You saved me alot of money man much apreciated
@joetheplumber5781
@joetheplumber5781 Жыл бұрын
Thank you for this well made video!
@captainmedvar
@captainmedvar 6 жыл бұрын
Thank you so much!! I fixed it this morning. Your info saved me! Had to open it and turn the motor.
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Welcome GFM
@mh718
@mh718 3 жыл бұрын
I want to THANK YOU! Oil burner locked out and did not restart. Did the normal maintenance - filter, cleaned gun, changed nozzle. Still nothing. Realized no oil to the gun, so took the whole thing apart looking for something clogged. Nothing. I thought maybe the pump was not working - flummoxed. Called for repair guy, but it's New Years Day and the guy said it was $300/hour. I decided I'd wait for Monday. Then saw that Home Depot has the pump so I figured it was worth it to try and just swap the pump. $100 and 1 day later, but this did not fix it. Then I thought maybe it's sludge in the line and the pump just can't pump it. Cleared out the entire line by disconnecting from the tank and the burner and literally blew it out with my own lungs - lots of crud, but still didn't fix the problem. Ran clear from the tank to the burner, much faster now, but still would not fire. Then I remembered you said something about the coupling and I pulled that out and looked at it more carefully. It would spin if I put it on by hand with the pump out, but then I had an "ah hah" moment. The thing was partially reamed out and would not spin the pump when it was assembled. Tried to find the part on a Sunday, but no dice. Bought some crazy glue, cut a tiny piece of plastic from the packaging and glued it in where it was supposed to have a flat edge. Banged it on from the blower motor side and reassembled. Tested it first by disconnecting the gun piping part and held a big plastic cup to that side - it spewed out oil like a champ! Reconnected everything and now the house is nice and toasty again. You need to have a special video devoted to those stupid plastic couplings. I wonder how often they fail? My instincts were right but I did not even suspect that thing.
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
Glad you got it going. GFM
@gagaovergaga1
@gagaovergaga1 9 жыл бұрын
Thank you!!!! Saved me a trouble call 2 minutes into your video. Thanks for sharing your expertise.
@inderjeetkaur3082
@inderjeetkaur3082 4 жыл бұрын
Thank you for putting this video out. It was immensely helpful
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
Welcome GFM
@Zoe_yard
@Zoe_yard Жыл бұрын
Exactly what I’ve been looking for thanks
@YoungFree213
@YoungFree213 3 жыл бұрын
never touched the furnace in my parents house, the button you show at 1:30 i tried and it turned right on like normal. im glad people like you excist on youtube XD
@garyabc
@garyabc 4 жыл бұрын
Great video series. Thanks for posting.
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
Welcome GFM
@elizeubranquinho4467
@elizeubranquinho4467 5 жыл бұрын
very nice video, straight to the the point, good job.
@janinemoore3720
@janinemoore3720 10 жыл бұрын
Thanks! Our furnace was refusing to go on day after Thanksgiving and it was freezing. We were about to call service guy, but I watched your video and we found switch popped on the motor and got it started again.
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Janine Moore I would purchase another motor because it will probably do it again. GFM
@janinemoore3720
@janinemoore3720 10 жыл бұрын
grayfurnaceman okay. Thank you.
@scotthouston7116
@scotthouston7116 4 жыл бұрын
Awesome... now that was great lots of helpful stuff.. now to try to fix mine..just has a slite click but nothing.
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
First, check the overload on the pump motor. If it has popped out, reset it. GFM
@jamminjimmyjam
@jamminjimmyjam 6 жыл бұрын
UEI C college Loves the Greayfurnaceman. we train with you often.
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Thanks for the support. GFM
@noweare1
@noweare1 6 жыл бұрын
Very usefull videos for us DIY types. Where would you suggest I look if one of two heating zones are not getting heat ? I can hear the relay clicking on/off as I turn the thermostat high and low. The thermostat goes to a control board that also has the water temperature controls. The furnace works as it should for the upstairs zone. Thanks for making these videos.
@riello2362
@riello2362 8 жыл бұрын
It's to bad we don't have the fuel quality we had fifty years ago or the mini pumps might just last that long. I just a fan of preventative maintenance and after 18 years in the field are no longer a fan of the older stuff. You old school guys taught me so it's your fault I know this stuff. Thank you!
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
Welcome! GFM
@alanmars7120
@alanmars7120 11 күн бұрын
My Dad who worked in the field until he was 86, taught me to partially close the oil firomatic once the flame lights if you feel the chamber may be flooded. Once the flame cleanes up open the valve again.
@miguelmarques4180
@miguelmarques4180 9 жыл бұрын
Thanks GFM you rock and I have learned much. thanks again
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
miguel marques WelcomeGFM
@dandanzoo
@dandanzoo 8 жыл бұрын
there is a reset on the motor but it never popped. removed the motor and put power to it works fine. I will check the cad cell, thanks for the information!
@EsorRose1
@EsorRose1 4 жыл бұрын
Awesome, my spun but only a bit then stopped, only went back and forth, i pushed a little hard and it came unstuck (i guess same effect as hitting with hammer) thanks!
@TrojanStarryNight
@TrojanStarryNight 2 жыл бұрын
Fantastic video and learned alot about my furnace over the past 30 years. I do have a question, I have a Weil McLain oil burner with a becket. I have hot water baseboard 1 zone as well as radiant floor heat in my kitchen. I noticed that sometimes the burner will start and then shut off after 4 seconds, then fire back up and all is good. What would cause this issue? Thanks
@mariobee2561
@mariobee2561 8 жыл бұрын
Hi.. Looking to do some maintenance on my oil burner furnace... someone did it last season, but actually ruined my cad cell.. Unknown if it was intentional, but he was actually expecting my call..... and of course the coldest part of the year... and my hunting Cabin had no heat.. i fixed because of your video. and steps on how to maintain.. what to clean? get new nozzle? anything? thanks.
@maestro0428
@maestro0428 8 жыл бұрын
Thanks for your video! Turns out the motor just needed to be reset and now everything works great.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
Glad you got it GFM
@carloselopez2088
@carloselopez2088 8 жыл бұрын
Thank you so much, my furnace is working again!
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
Welcome GFM
@judypaldino4731
@judypaldino4731 8 жыл бұрын
Carlos E Lopez how do i purge furnace
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
You only need to purge a single pipe system. There is a bleeder valve on the pump that you can open while the burner motor is on to purge and clear air. GFM
@SaltyRusCracker85
@SaltyRusCracker85 5 жыл бұрын
Thank you so much! Great step by step videos. 😁👍
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Welcome GFM
@glenntoth511
@glenntoth511 8 жыл бұрын
Love your videos! I am having this issue: I have an oil fired boiler. I have to press the red reset button to start the burner. It then runs fine until it reaches the high limit temperature (180) (low is set to 120).... Then the boiler shuts off and trips the red reset button. The red light illuminates. If I press it once the burner will start again until it reaches temperature then it trips the circuit once again. I've replaced the CAD sensor, electrodes and set the electrodes with the Beckett gauge, replaced the fuel nozzle, all the filters and the Honeywell R8184 relay. The aqua stat is a very old Honeywell. Not sure of the model. Could it be the aquastat causing this problem?
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
The relay should not trip the burner safety. There has to be a flame problem. GFM
@migikuburic4237
@migikuburic4237 6 ай бұрын
Great info ,thank you a lot👍
@goatcrapp
@goatcrapp 10 жыл бұрын
Wow - great video series - i've been watching your vids, and just came across what i believe to be relevant to my situation... it's an oil boiler, not furnace, but the problem seems analogous. an elderly aunt's boiler has apparently not worked properly in years. As witnessed by me, she presses the reset button, there's an electrical hum - then she taps the side of the burner motor with a rubber mallet she keeps down there just for this purpose. Sometimes it takes a few moderate whacks, and eventually kicks over. It'll run fine until it's no longer needed (thermostat up to temp) - and then she'll repeat this process the next time she needs heat. I'm finding a tech anyway to come in and service the system, but at this point, i'm suspecting i should be ready for a new burner motor - was this a common need "back when" - because she seemed to act like it was no big deal, and she's always done it like this, lol.
@nick4556
@nick4556 10 жыл бұрын
Hi it's Jan 1st my furnace would not start thanks to your video it was able to start it may thanks
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
nick4556 Great way to start the new year. GFM
@MrRaymos23
@MrRaymos23 8 жыл бұрын
Gray I accidentally cut the wire from my thermostat to my oil furnace I reconnected where I cut the wires but now my oils furnace does not turn on . I can hear the click noise from when I turn my thermostat on but no heat
@Capebretonguy902
@Capebretonguy902 5 жыл бұрын
I got a huge problem wit my furence last night around 12 hours ago it stopped working theirs lots of hot water but no heat the thermostat is turned up to the max and still the furence ain’t kicking in I hit the reset button nothing no power I checked the fuse it’s still good, I don’t kno what’s going on I have lots of hot water but no heat would it be the diverter valve ?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
First, not enough info to tell. Possible pump problems? GFM
@markcoyle3874
@markcoyle3874 5 жыл бұрын
Mr. Gray ...great video... I have a Wayne oil burner with a Delavan .50 80 degree A gun nozzle ... I assume the .50 is in gallons per minute. If I replace the old nozzle with a .60 80 degree A, will I have trouble?.. Will the extra .1 gallons per minute be a problem.
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
You will need to adjust the air shutter to compensate. GFM
@ebutariq99
@ebutariq99 2 жыл бұрын
Excellent job
@aspenessis
@aspenessis 2 ай бұрын
I have an intermittent lock out issue. Becket burner fires and runs fine for weeks. If we get a warm spell, and it doesn't run for 8 hours or so, it locks out. The top of the control module is very warm ? and it won't restart when reset..Unless I turn the power off to the furnace for a few hours, and try restarting again. It fires right up and will run fine till the next warm spell. Any insight is appreciated !!!
@grayfurnaceman
@grayfurnaceman 2 ай бұрын
You may have a problem establishing draft up the chimney. If the unit rumbles upon startup, this may be your problem. Look for restrictions in the smoke pipe and chimney. GFM
@widfo_moto7345
@widfo_moto7345 10 жыл бұрын
Fantastic set of videos and great info on your website. Thank you very much for doing this for us DIY guys. I'm hoping you can help me out with a question though. I've gone through the diagnostics you've shown here. I ended up replacing the motor just in case as it was spinning very freely and I figured why not. After changing it though, same issue. Heater kicks on, sparks, but the fan/pump motor won't turn at all. I'm thinking the fan should kick on to pump fuel into the chamber, the ignite. Do I have that backwards? Is possibly my cad cell relay is the issue?
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Chris Davis Sounds like the cad cell relay may not be sending power to the motor. If you can use a voltmeter, check the wires going to the motor before it safeties out. GFM
@widfo_moto7345
@widfo_moto7345 10 жыл бұрын
I tested with my multimeter and the output was 10% of the input. By passed the Honeywell to power the pump and everything spun up. New part ordered :) once again thank you the educational information shared on your sites.
@rebelsprophet7185
@rebelsprophet7185 8 жыл бұрын
I have a Repco GM - Series Gas Fired Boiler. [30 years old?] Pilot will not stay lit. Emergency switch on wall up stairs will not fired boiler when thrown on. No power to boiler. If there is no power, will the pilot flame extinguish? Is there a reset set switch on the unit? Thank You for your feedback. Joe, Long Island. P.S. Burnin' the midnight oil with the kerosene lamps and sleepin' in the den.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
If the unit is a standing pilot, the pilot will not go out if power is off. I would be checking breakers and power switches. As for a reset, I don't know. GFM
@rebelsprophet7185
@rebelsprophet7185 8 жыл бұрын
GFM, are you meaning the pilot vertical, as per standing? As i looked, it seems to be horizontal. I will throw the Mains. Thanks for being there! Joe, L.I., N.Y.
@JamesYaw
@JamesYaw 2 жыл бұрын
I have a Becket that just stopped. I isolated the motor, the motor works. Since the gray box has a black (hot), white (neutral) and redish wire (switch leg) coming out of it, it must be this box. Hundred dollars plus, no it wasn't the gray box. It still sat there and did nothing. I disconnected the "Beckett Electronic Igniter and it works without igniting. Replaced the Igniter and now have heat. Hope this help other people.
@henrysorensen7241
@henrysorensen7241 4 жыл бұрын
Why would i have to reset the trip on cad cell relay every few weeks now. I paid for a $200 service call for the first time it happened. I have the boiler cleaned and serviced every year. Basically they couldnt find anything wrong but replaced the nozzle anyway. They also said the arc on transformer was ok but not the best, but still they though it was sufficient. The motor wasnt tripped off, but when i hit the reset it instantly fired up. I did however notice after observing it fire up the on occasion when motor comes on it instantly fired up but sometimes it took a second or 2 to fire up. The boileris a beckett AFG. I dont want to start throwing a ton of money at it if i can narrow down the cause. I have watched almost all of your videos and your very informative. Any information you can advise me on would be very helpful. Thank you sir Henry
@anwarkarimi
@anwarkarimi 10 жыл бұрын
Hello GFM, Great video, I have an old intertherm oil furnace, when it calls for heat, the flames will go up for a few seconds, then gets cut off, and after less then a minute the reset button pops out.I reset the button and its the same before . I changed the nozzle and cad cell, but still I have that issue. I bled the oil and cleaned the filter and pump screen, still nothing happened. Could you please help me on what I should do about it?
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
anwar karimi I would be looking at possible plugged vent or possibly a plugged combustion air inlet if it is in a mobile home. Hope this helps. GFM
@anwarkarimi
@anwarkarimi 10 жыл бұрын
grayfurnaceman Thank you for answering my question. The problem wasn't what you said. I opened the gun pipe oil to burner and turned the power on. But just for a few seconds it sent the oil and that's it. Do you think its an oil pump problem or a fan motor problem? But sometimes the fan was running smoothly, but sometimes it wasn't. And I checked the fan by hand and its easy to rotate, which means i think its okay , but still i'm not sure.
@jaxeru6239
@jaxeru6239 10 жыл бұрын
anwar karimi You've probably sorted the problem by now, but that sounds like the Solenoid coil to me, hopefully that helps for future reference.
@geojor
@geojor 11 жыл бұрын
interesting point you make that the cad cell shouldn't see light before the flame lights...thanks for that...
@priengopinmithurdi
@priengopinmithurdi 8 жыл бұрын
I have a very similar Beckett burner and i have to push the actual grey square relay (under the cover) down to get the furnace to kick on. It runs one cycle each time I do this. It wont kick on if I jumper the thermostat at the relay. The ac still works fine from the thermostat and will cycle all day. Any ideas?? Thanks! Your videos have been a big help in narrowing it down so far...
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
You could have several possibilities here. The cad cell relay may have failed. You could have a poor signal from the cad cell, or you could have a flame failure from a blocked filter. Hope this helps. GFM
@MrDanny1775
@MrDanny1775 7 жыл бұрын
Awesome video, very detailed!!
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Thanks for the support. GFM
@leeturner1838
@leeturner1838 6 жыл бұрын
thanks you saved me a bunch of money!!!!
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Welcome GFM
@dane7401
@dane7401 7 жыл бұрын
Thanks 4 video. Would you have any hints for maintenance for a furnace with an outside oil tank (not by choice)in the Northeast? I always have the furnace serviced in late fall, but it always seems to give me issues around mid Winter, requiring a service man to come in.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
The most helpful thing you can do is order #1 stove oil instead of #2 fuel oil during the coldest temps. Usually 100 gallons in a 275 gal tank will keep it from gelling. GFM
@darealone7823
@darealone7823 8 жыл бұрын
hi yes I have a Honeywell oil furnace and its been here for a while but when I turn it on manually with the power switch it just clicks with a green light flashing and then clicks again and light goes off and I tried to test the igniter it didn't give out a zap but it could be something else but I hope u can give my suggestions and also I have a huge oil tank that runs into the basement and the valve is off should I turn it on?
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
The tank valve must be on for the unit to have access to oil. Does the burner motor start? GFM
@mnhsty
@mnhsty 3 жыл бұрын
Have power, no start. Unit got hit in a basement flood to the top of the blower. Should I bother troubleshooting or just replace everything?
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
If you have the choice, replace it all. GFM
@btainer
@btainer 7 жыл бұрын
Hello! And thank you! I was sooooo hoping I had just run out of oil. Measuring 4 inches @ 17 gallons... crap! The reset has triggered. I did note that the basement smelled a little of oil. I reset it. It sounded hopeful. I could hear what sounded like oil spraying... but it didn't ignite and the reset triggered again. Now what? I will continue seeking out your videos to see if I can't pin it down... between property taxes and income taxes I'm about all tapped out until a month or two after April and my truck decided to break down just yesterday TOO! I need to try to tackle this myself even though I'm scared to death of blowing up the house. How do I know that the oil is coming in and not igniting? (as I suspect) If that is the case what do I do? I'm afraid to hit the reset again... if I have unspent fuel piling up in there it could go boom, right?
@dansouza6284
@dansouza6284 2 жыл бұрын
Hi GFM I have an old Olsen oil furnace. It lights up and cycles, but the blower motor won't kick on. I'm was thinking maybe blower motor or capacitor. The motor spins freely, I just can't find the capacitor. I don't know what I should do please help.
@grayfurnaceman
@grayfurnaceman 2 жыл бұрын
It may not have a capacitor. I would be checking for power to the motor. No power, look to the fan switch. GFM
@pierre-pete-martin7576
@pierre-pete-martin7576 7 жыл бұрын
very much appreciated this video of yours thank you, my furnace is running nicely again.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Glad you got it going. GFM
@tommy-leescott-johnson2353
@tommy-leescott-johnson2353 7 жыл бұрын
squishy cuttinging
@anthonymaloskey9830
@anthonymaloskey9830 4 жыл бұрын
The motor runs when I give it direct power and the pump isn't bad where would you turn next? Maybe the cad cell?
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
If the pump does not start when there is a call for heat, have you reset the cad cell relay? GFM
@mantaspitkunigis9843
@mantaspitkunigis9843 8 жыл бұрын
i have burner with tiger filter, the kerosine doesnt come to it ....would you have idea what should i do.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
Have you checked the oil filter for blockage? GFM
@jbkahl
@jbkahl 7 жыл бұрын
check the glass photo eye too make sure it is clean as it senses the flame and talks to the ignitor to stay on once it senses a flame. If dirty burner will shut off.
@sandradelawder465
@sandradelawder465 9 жыл бұрын
Furnaceman, I have a Lear Siegler Model MOC80 oil furnace. It won't turn on unless I push the reset button {red button}. After it gets to the right temp (what the thermstat is set on) it will turn off but won't start again, when house gets cold, until I push the reset again. What's wrong??
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
+Sandra Delaware You probably have an oil supply problem. Have you changed the oil filter? GFM
@bobolon2g
@bobolon2g 9 жыл бұрын
Your videos are a big help, thank you for putting them out there.
@m.griffith2059
@m.griffith2059 9 жыл бұрын
I have a Beckett oil burner with hot water heater. I have purchased three controls the one to the right of the unit that has the button you use to restart the burner. They all cost about $100. - $125 each. The first two lasted less then a year. The next one I purchased never worked and the shop would not take it back. Now I have to get another one. What do you think the problem is? It was installed by Viano Heating and Cooling, of Poughkeepsie NY. and the main owner who worked on the boiler has passed on. I called another company and they want $125. to come out that is applied to the first 15 minutes!
@hillgaudon5614
@hillgaudon5614 9 жыл бұрын
Marine Atlantic
@SuperJV4x
@SuperJV4x 10 жыл бұрын
a pin hole leak in my standard water plumbing pipe squirted water into the box that has the reset button and tripped the burner and now the indicator light is on. If I dry it off, is it safe to press the reset button? Thanks
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
SuperJV4x I would not trust it. Big time safety hazard. Replace it. GFM
@slipperyjohnson7016
@slipperyjohnson7016 Жыл бұрын
Been watching your vids, but can't seem to see my problem. My boiler will start and run when I hit reset switch and it runs fine. When it shuts down it won't restart on it's own. I can hear it making a humming noise, but it won't actually start unless I hit reset again. Then it runs for a while and heats up until it shuts down again. When it's running it seems to run fine. I'm not sure what to check. you have any videos on that?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
My thoughts are that you could have an oil supply problem. A plugged oil filter or supply line blockage are common. GFM
@slipperyjohnson7016
@slipperyjohnson7016 Жыл бұрын
@@grayfurnaceman Ok. I just changed the filter and nozzle about a week or so ago. Filter is new and when I bled it it was a strong flow. If I hit reset it fires right up and runs like it should so oil seems to be flowing. It's just when it shuts off it doesn't start back up. Like it doesn't even attempt to. If oil flow was an issue, wouldn't it at least try to start then lock out? I was hoping I could fix it because I like to know how to maintain it, but I might have to call a guy in. I just rebuilt the burn chamber and it ran great for a week before this problem. Great videos BTW.
@bazzer245
@bazzer245 9 жыл бұрын
Hi, when i push my red button box, the boiler does not stay on, i am wondering about 3 loose wires in this box. I will check out the colours if you think you can help, thanks.
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
bazzer245 Does the unit fire off, then shut down after approx 1 minute? GFM
@shtreyubadgygbu9346
@shtreyubadgygbu9346 7 жыл бұрын
Hold your reset button for 45 to 50 seconds that may reset it.My blower moved easily and i held it for 45 to 50 seconds and it came on try it if on lockout.I ran out of oil the winter before.Put in a about 15 gallons from my Dads tank and it came on when i did this.
@jewelshawley4107
@jewelshawley4107 5 жыл бұрын
Yea mine was nothing like ur saying mine had unnecessary cotton in where the flame is and I'm pretty sure that's not at all right/ normal . But ur video of the very pix I posted ur not telling my story thx though it was a cute try👏🏼👏🏼👏🏼👏🏼👈
@hmill1227
@hmill1227 10 жыл бұрын
Very informative on start up of my system I hear electrodes sparking but the motor does not start. You removed the motor is that so it doesn't pump oil into the system. I think the motor is bad
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Harvey Millner That's just a last check to be sure the pump is not wearing out. Be sure the manual reset limit(if it has one) is not kicked off. Hope this helps. GFM
@hmill1227
@hmill1227 10 жыл бұрын
Thanks I pulled the motor and found that the motor runs when I plug it in but not when it's hooked up to the furnace so I assume I'm losing power somewhere. I hope you can give me details that will help . I previously had a service call and the prob was the clogged orifice it worked fine and now it's not powering at all ...the motor that is
@petersam7030
@petersam7030 9 жыл бұрын
sire i have a question if i have a cabin 13*4*2.70 meter and i need to choose a stable oil (gasoline) burner furnace . how i choose and how much power do i have to chose ? cabin is for curing painting fiber please answer as soon as possible thank
@mainelyelectric
@mainelyelectric 5 жыл бұрын
Question for you. We’ve talked in the past about the first mobile oil furnace that I have made a video of. The question is I’m installing a second one to heat my greenhouse. This one is a around 85’000btus compared to the one I first installed that is 63’000 it’s going to be in its own little shed attached to the greenhouse, on the one in my dad‘s workshop there is no barometric damper on the 4 inch pipe that is basically directly leaving the building and going out about 4 feet from the building with a T fitting then going up another 4 feet with a cap. On the one in my greenhouse the building is 8 x 8 and I plan on going out the flat wall 8 feet from the furnace and doing the similar T fitting and probably 2 feet of pipe up with a cap, do I need to get a 4 inch barometric damper or do these furnaces not require them? Thanks again for the help in the past Ben
@stevendavis1482
@stevendavis1482 10 жыл бұрын
I'm wondering if I need to replace my motor to my furnace..I added oil yesterday, I bleed about a gallon worth, and I constantly have to push the reset button..sometimes it starts right up other times I can spend an hour+ pushing it. When it started and stays on consistently it's fine but if I lower the thermostat about 10+ for a while then I have to start the pushing game again..a big headache..please help
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
if you get a steady stream when bleeding and no air bubbles, you could have a pump failing. You should check pump pressure. Also, you could have a partly plugged nozzle. Hope this helps. GFM
@stevendavis1482
@stevendavis1482 10 жыл бұрын
grayfurnaceman thanks. Found out yesterday it the transformer was weak. Had it replace and serviced working great now. Cost about $400 but I live in Mich and need my heat
@84FrankDaTank
@84FrankDaTank 9 жыл бұрын
I have that same problem
@JrPetersonJr
@JrPetersonJr 9 жыл бұрын
Hello , I am getting blowbacks on my beckett fuel oil furnace. i put new filter on and replaced the pump screen and gasket. I have a new nozzle here. The furnace is not lighting sometimes but If I lightly tap the pump on the side with a small wrench it kicks right on . Now I am left wondering , is it the nozzle, the pump, or the coupler....
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
John Peterson I would be looking at the pump solenoid if it has one. Could also have a spark problem. Shorting to ground, or a failing transformer. Hope this helps. GFM
@guitarman196969
@guitarman196969 7 жыл бұрын
You Sir are the man, Thank you very much.
@alfonzoavion4740
@alfonzoavion4740 5 жыл бұрын
Hello if u can help me out with this issue I have I'm working on a Lennox electric furnace and my general porpuse switch gets hot when I run what could it be thanks in advance
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
I will need much more than that. What switch? Sequencer? GFM
@alfonzoavion4740
@alfonzoavion4740 5 жыл бұрын
I found out what it was thanks for ur time thanks for all the videos u put up
@dandanzoo
@dandanzoo 8 жыл бұрын
my burner is doing nothing at all. checked the motor and works fine. the red button never tripped but I can manually trip and and the red light will come on. there is power to it. could it be my thermostat? again no noise nothing at all. also could it be my Honeywell r8184g intermittent ignition oil primary? please help! !
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
+dandanzoo You can jumper the thermostat by connecting the T-T terminals. You can also disconnect one of the terminals connected to F-F. If it starts when disconnecting one of the F-F terminals, the cad cell is shorted. Check on the side of the burner motor to see if there is a reset button. Just a few things to try. Hope they help. GFM
@ApologeticsandEvidence
@ApologeticsandEvidence 11 жыл бұрын
My oil burner will run sometimes for days, and sometimes only for seconds after I push the red button. It is completely random and I have put a new filter on the line and a new nozzle. Why does it keep shutting down? Great videos btw!
@grayfurnaceman
@grayfurnaceman 11 жыл бұрын
First, does the flame come on when you press the reset? If the flame is coming on and it still shuts down during the 40 second trial for ignition, There may be a sensing problem. Clean the cad cell first. If that does not help, check the resistance of the cad cell dark(20000+ ohms) lit(less than 1000 ohms). If all checks out, the cad cell relay. Hope this helps. GFM
@lisalambert1689
@lisalambert1689 7 жыл бұрын
where can I buy parts? everyone listed is a wholesaler, or a contractor.
@johnnyappleseed5590
@johnnyappleseed5590 Жыл бұрын
I can’t figure out how to get my oil furnace running. I checked the igniter cleaned it off good, changed the filter in the line before it gets to the furnace, replaced the igniter transformer cause it’s bad. Replaced the CAD cell last year! The filter right before the pump had a little grime but I cleaned it off and it looks pretty good. The relay was replaced last year. When you try to run the fan kicks on for about 40 seconds then it shuts down so it still seems it’s not getting flame. Does anyone have any suggestion? My motor for the fan turns very easily I saw in a video it said it should have a little resistance. Wish I knew what the issue was it’s getting colder here and we don’t have money to pay someone to fix it. Could it be the nozzle it was replaced last year? I’m not sure what else to even try.
@apartmentforrent5637
@apartmentforrent5637 7 жыл бұрын
Hi there have a similiar furnace.. it is a downflow furnace in a mobil hoome. have black smoke coming out of chimney, and not working properly at all... have any videos on how to clean out the furnace? it is a seasonal home in a remote area, difficult to get someone up there to work on it... wondering if you can help...appreciate in advance.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I do have a furnace cleaning video. Check my channel. You will also need to replace the nozzle and service the unit. GFM
@farisibrahim9591
@farisibrahim9591 8 жыл бұрын
Thanks for the video.i have a question regarding my burner,it randomly lockout and it needs a reset frequently.what could be the problem ?(usiong siemens control) ...thanks again
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
It could be a number of problems. Oil supply blockage is first. Change the oil filter. The cad cell could be dirty. The nozzle could be partially plugged. The cad cell relay could be failing. These are a few of the possibilities. GFM
@beefyramos
@beefyramos 8 жыл бұрын
my furnace is very similar to the one in this series. mine has power, but when I press the reset, the button goes down, nothing happens, then after about a min the reset will pop back out. I took the motor out and connected it directly to power, & it works great. so now I'm stuck, not sure why it's not doing anything.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
If you try to press the reset before a few minutes have passed, it will not reset. Sounds you may have an oil supply problem. GFM
Troubleshoot the oil furnace part 3.  Fire comes on but shuts down.
8:35
Oil furnace troubleshoot part 2 No flame
11:47
grayfurnaceman
Рет қаралды 909 М.
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 42 МЛН
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
beckett AF oil burner tripping out every day or so
16:56
steven lavimoniere
Рет қаралды 270 М.
How To Restart An Oil Furnace | Hard Lockout and Bleeding Fuel Lines
4:08
Everyday Home Repairs
Рет қаралды 223 М.
OIL FIRED BECKETT FURNACE WILL NOT FIRE UP -JUST SERVICED
15:48
steven lavimoniere
Рет қаралды 54 М.
Quick Oil Boiler Service! Nozzle and Filter Change!
21:26
Jeff’s HVAC Adventures
Рет қаралды 29 М.
Oil Burner Primary Control and CAD Cell Operation and Troubleshooting!
11:13
AC Service Tech LLC
Рет қаралды 206 М.
oil furnace start up
6:32
Josh Does Hvac
Рет қаралды 1,9 М.
Unfiltered 100% Waste Oil Vs Stock Diesel Heater
19:38
SteinFab Garage
Рет қаралды 544 М.
My version of a waste oil heater
5:42
North Idaho Wrenchin
Рет қаралды 68 М.