During maintenance I found the unit not operating correctly. I found a fault code on the VFD in the blower compartment. I also found a loose belt.

Пікірлер: 11
@raddo555
@raddo555 9 ай бұрын
So all this for a loose belt!?
@HVACServiceTechnicianTalk
@HVACServiceTechnicianTalk 9 ай бұрын
I ended up installing a new belt. The fault code never did come back. Small chance my fault on the VFD was from a power outage. I have seen VFDs throw all sorts of codes when that happens.
@natenielsen7066
@natenielsen7066 3 ай бұрын
I have two brand new units exactly the same as this only been running for a month and they both are continuously hitting the same VFD errors. Any help would be appreciated
@boduke2299
@boduke2299 3 ай бұрын
With cooling mode energized shouldn't the vfd go to 60hz the fan should be ripping.
@diazinc462
@diazinc462 2 ай бұрын
not if you calibrated and did a proper air balance. ramping up air speeds could cause supply temp issues depending on the duct work
@mark.r8900
@mark.r8900 Жыл бұрын
my york rtu unit is in heat mode and giving a HS1 limit switch error on the smart simplicity control. I've checked the high limit switch and it seems fine. The manual for the control says the LS1 has tripped 3 times within an hour. This results in the HS1 LIMIT SWITCH LOCKOUT. Any help would be greatly appreciated. Thanks.
@samuelsech2278
@samuelsech2278 Жыл бұрын
Board might need to be updated...I had same situation on York rtu
@diazinc462
@diazinc462 2 ай бұрын
fan speed isn't fast enough causing the unit to trip. jump up your fan speed or get a higher rating limit switch. if you have a VFD on heating make sure your fan speed is at 100% on each stage.
@amfmechanicbowlingcommunit5048
@amfmechanicbowlingcommunit5048 Жыл бұрын
How Do I test my VFD speed to see if it’s running in full cooling ? for sample, I know that a degraded fan signal ca results in the fan speed being lower that the board is requesting. For example, at fan only 50% fan signal should be 30 HZ on the VFD. At 100% fan signal (full cooling) the VFD should be running 60 hz. If you see something different, the board may need to be replaced. Any Idea?
@diazinc462
@diazinc462 2 ай бұрын
make sure your board is set to Fixed variable speed . if you set cooling stage 1 fan speed to 100% your vfd should've bumped between 56-60 if its a low number 35-43 change your board.
@RefrigerationDevil
@RefrigerationDevil 6 күн бұрын
@@diazinc462 thanks sinsei
Carrier rtu AC not cooling
18:08
Curious HVAC Guy
Рет қаралды 20 М.
Help Me Celebrate! 😍🙏
00:35
Alan Chikin Chow
Рет қаралды 42 МЛН
The selfish The Joker was taught a lesson by Officer Rabbit. #funny #supersiblings
00:12
Lennox RTU not cooling
10:51
Curious HVAC Guy
Рет қаралды 7 М.
Carrier VFD problems?
18:13
Everything HVACR
Рет қаралды 3,5 М.
RTU Operation & Sequence
6:07
Tec Tube
Рет қаралды 9 М.
York RTU Multiple Problems
50:07
The HVAC Hacker
Рет қаралды 14 М.
What the Maker of Ozempic Doesn't Want You to Know: It's Bankrupting America
12:01
SE Board Set Up JUN2015
5:24
Ray Beato
Рет қаралды 20 М.
Rooftop Unit Not Cooling-HVAC Service Call
11:04
HVAC Tech Tips
Рет қаралды 23 М.
Help Me Celebrate! 😍🙏
00:35
Alan Chikin Chow
Рет қаралды 42 МЛН