I Work residential. I like your vids man. Never seen a relay that looks like that.
@mr.pisces226hvac8 Жыл бұрын
Thanks 👍
@sinuntitulouniversitario Жыл бұрын
I have follow everything you did but my 20A fuse keeps blowing up any ideas about it ?
@mr.pisces226hvac8 Жыл бұрын
@@sinuntitulouniversitario Hey, the problem could be the K2 relay, it will appear smoked if bad, also the only things on that 20A fuse circuit are the Magnetrons, ohm them out should less than 1 ohm, then check each terminal to ground should read open, capacitor slowly should read .91uf, other than that you might have a transformer problem
@deenamat43921 күн бұрын
Why that 20Amp Fuse Blow up ? which magnetron is bad ?
@rudyramirez957710 ай бұрын
Got a video on the i3 turbochef F3 mag code?
@mr.pisces226hvac83 ай бұрын
Not yet, but we starting to work on them now
@rudyramirez95773 ай бұрын
@@mr.pisces226hvac8 cool I could really use some help with these ovens. Are there any special tools that might help diagnose an issue? My boss said the guy who usually fixes our ovens hook up his computer to it for something but I haven’t heard of or seen anything like that.
@mikewallace944810 ай бұрын
I put a bowl of water in the cavity for a load so I don’t have to worry about messing up the mags in both test and regular mode. I like to cycle the unit to make sure it’s fixed.