WORKSHOP RENOVATION 16 : DIY Shop Electrical Basics w/ Conduit Bending

  Рет қаралды 183,172

Crafted Workshop

Crafted Workshop

Күн бұрын

Пікірлер: 252
@charlesemmer8856
@charlesemmer8856 Жыл бұрын
Another good practice is to label each of the receptacles with the circuit breaker number (from the panel schedule).
@craftedworkshop
@craftedworkshop Жыл бұрын
Definitely planning to do that after painting! Good tip!
@jaggederest
@jaggederest Жыл бұрын
Hospital standard is to label the outlet with the panel number and the circuit number. Especially when you have a bunch of panels it's a life saver (literally, in the case of life support equipment). I don't know if that's just an institutional thing but it made sense to me. P7C15 etc
@soisaidtogod4248
@soisaidtogod4248 Жыл бұрын
OCD much? LOL
@JeronimoStilton14
@JeronimoStilton14 Жыл бұрын
@@soisaidtogod4248 Until you spend an hour rooting around for the exact right switch so you dont have to shut your whole shop down.
@rayman954
@rayman954 Жыл бұрын
I just did a quad box last week and found the tabs you break off of the face plate is actually a nut to be used with screws on the outlet, this was a great idea to me as i dont always have the correct nuts and screws on hand.
@iAmVonexX
@iAmVonexX Жыл бұрын
as a german electrician, american electric never cease to amaze me. this is so unusual for me i have to remind me that it's not neccessarily bad. also i love the tubes
@EnigmaPSU
@EnigmaPSU Жыл бұрын
Just a helpful FYI to save you some money. At about the 11:25 point in the video you show breaking off the small tabs on the metal faceplate and removing the screws from the GFCI outlets. Then using #8 screws and nuts to attach the outlet to the faceplate. Actually, those small tabs you broke off of the faceplate are tapped to act as nuts so that you can reuse the screws you removed from the outlet in order to attach the outlets to the faceplate.
@craftedworkshop
@craftedworkshop Жыл бұрын
Thanks for that, will make adding the rest of the 120V outlets easier!
@kraken509
@kraken509 Жыл бұрын
I do dual duplexes as well but put 2 circuits in each box. All left duplexes are one circuit and all right are another. One thing to consider next time is showing the deburring of the conduit after cutting it.
@onnokonemann9326
@onnokonemann9326 Жыл бұрын
Still amazed that you use metal boxes and conduit for electrical. To me as a Europeaan that is just mad
@koolkar55
@koolkar55 Жыл бұрын
You guys are lucky to be able to do this work for yourself. Down here in Australia you need to be a fully qualified electrician to do any electrical work. We also have different power available to us, all domestic single-phase outlets are 240 volt & commercial 3 phase is 415 volts. Billy J... Queensland, Australia
@giff983
@giff983 Жыл бұрын
We can also have 208volt 3 phase in the US in addition to 240v single phase, 110v single and 480v three phase. makes it a bit fun at times.
@jerishigan6567
@jerishigan6567 Жыл бұрын
If this shop burns down, insurance will deny his claim based on this video alone.
@polerin
@polerin Жыл бұрын
@@jerishigan6567 in many places you can do the work and have an electrician sign off on it.
@EPortillo5000
@EPortillo5000 Жыл бұрын
Well sometimes is better that way when the electricians are really qualified , in my house half had reverse polarity and nothing was grounded.
@mankins
@mankins Жыл бұрын
In the US you just need a KZbin channel to know how to do everything.
@davidfeldman7001
@davidfeldman7001 Жыл бұрын
An alternative to box offsets on EMT for those who are not comfortable with bending is to use back straps or spacers at the strap locations. This aligns the EMT with the KO’s in the 1900 boxes. Another benefit is les dust settles into the space where the EMT runs along the wall. Just another option.
@TxStang
@TxStang Жыл бұрын
They also sell offset fittings about 2" long that attach to the boxes and jog down to the EMT . For 2 bucks each they make it go fast and simple and keep the EMT close to the wall .
@AttilatheHuntamer
@AttilatheHuntamer Жыл бұрын
Locked down in STORMCON Charlie for the past 12 hours in Greenland, got super excited to see a new shop video
@oliveraberg6585
@oliveraberg6585 Жыл бұрын
In sweden and the rest of europe wago conectors are standard👍🏻
@customsolutions7167
@customsolutions7167 Жыл бұрын
Yes every U.S. electrician knows that .. And doesn't care .. we don't use them ...😂😂
@grantev
@grantev Жыл бұрын
Even though electrical work can be simple, it requires a lot of careful thinking, and there can be many safe or unsafe ways to accomplish the same thing. Most DIY channels would skip this video, but Im glad you tacked it again (including following and showing the updated NEC). If i could suggest 1 thing, i would say to purposefully mess up some inane thing so that thousands of people will comment to correct you, thus driving views to your video 😂.
@gdworkshop
@gdworkshop Жыл бұрын
Great job Johnny. Great series of workshop upgrades. Its crazy how different the electrical work is different from country to country. Look forward to the next video.
@tasobouzinelos8027
@tasobouzinelos8027 Жыл бұрын
I have done some residential electrical work, but never commercial. It’s great to see you take your time to explain the process. Thank you for sharing the great content
@johnkulpowich5260
@johnkulpowich5260 Жыл бұрын
Glad you showed this. Now people will get a idea. On why electrical work is expensive
@craftedworkshop
@craftedworkshop Жыл бұрын
For sure. Materials alone were easily a few thousand dollars with all of the wire. Not cheap!
@scruffysanta8442
@scruffysanta8442 Жыл бұрын
Great idea on the 2 circuits. My electrician did that for me, but I only have 2 outlets along each side wall. Mush easier for me :) Really enjoy following along with the shop build out.
@marto.4427
@marto.4427 Жыл бұрын
Waiting for the gigantic logo on the front wall with lights and made of wood of course 😎😉
@charlesemmer8856
@charlesemmer8856 Жыл бұрын
It is important to know that wherever armored cable is cut, you should install a red head insulator to protect the wire. It fits inside of the srmored cable.
@macxgeek
@macxgeek Жыл бұрын
Was thinking that too
@craftedworkshop
@craftedworkshop Жыл бұрын
Yup, forgot to show that but definitely doing that everywhere.
@lou9108
@lou9108 Жыл бұрын
Charles is correct. It is called an anti short bushing.
@bluebanana6753
@bluebanana6753 Жыл бұрын
In sweden, we run gfci breakers that break all the power (most often you have another one for fridge/freezer). We also has three faze into our house so it's a three faze one.
@macxgeek
@macxgeek Жыл бұрын
Looks great! Love the deeper boxes with two circuits each. Good call on the dedicated ground and separate colors. Strange that there would be 3-phase power into a sub panel, do you have true 3-phase coming into the building? One thing I found useful is to install a couple rectangle USB/outlet combos around the shop. Handy for charging a phone or using clip-on USB lights on any of the tools. Looking forward to the next video
@KevinCoop1
@KevinCoop1 Жыл бұрын
Very well done and correct video! Congratulations. I’m not sure why you showed a dwelling unit rule in the NEC when discussing GFCI. They have been required a long time in non dwelling locations. You could have also wired all those box locations with two circuits at each. Left one and right two. Slightly more flexible.
@AndyCallaway
@AndyCallaway Жыл бұрын
Wago connectors FTW 👍
@michaelcervoni8859
@michaelcervoni8859 Жыл бұрын
Loving this series congrats on an amazing work space!!
@MCsCreations
@MCsCreations Жыл бұрын
Pretty nice work, Johnny! Nicely done! 😃 Stay safe there with your family! 🖖😊
@dadlife8289
@dadlife8289 Жыл бұрын
Cool to see you doing electrical. I'm about to install the Mr Cool system and will need to install a new 240v circuit. Your video today serves as motivation because I have no electrical experience
@mikelinzy5969
@mikelinzy5969 Жыл бұрын
Glad I watched this. I'm planning on some electrical mods in my garage and that dual circuit idea is a banger.
@kenr2412
@kenr2412 5 ай бұрын
The gray neutral is for 277 volt circuit. You need to use white for 120 volt circuits. You could have used one neutral to share with both circuits. If you share a neutral with two circuits, you also need to have a two pool breaker or a handle tie to turn off both at the same time. Don't forget to get an electrical permit and have your work inspected. You'll make your insurance agent happy.
@hansangb
@hansangb Жыл бұрын
So jealous of your every other box is on a different circuit design. Well done!
@Bettercalldough
@Bettercalldough Жыл бұрын
Coming from the UK I find it astounding that the US do electrics like they do…
@AreBaloni
@AreBaloni Жыл бұрын
Bingewatched the entire shop-series yesterday! Great work, and can’t wait to see the next episode 🙌🏼
@robthewaywardwoodworker9956
@robthewaywardwoodworker9956 Жыл бұрын
Great stuff. Enjoying this project. And no, I'm not jealous. No really, I'm not. Ah who am I lying to, I'm very jealous! LOL Keep up the good work.
@RonaldCJones
@RonaldCJones Ай бұрын
Just discovered your channel and subscribed. Like your presentation style and content. Well done!
@dansarfert3585
@dansarfert3585 Жыл бұрын
There was a lot of great information here. Thanks!
@1BadRAMLimited
@1BadRAMLimited Жыл бұрын
I would not dare touch electrical work so kudos to you great content!
@pitsnipe5559
@pitsnipe5559 Жыл бұрын
During my four years of trade school I never could get my offsets straight. Hate bending EMT! 😊 back in those days (1960’s) what you refer to as MC cable, we called BX cable. The Navy was right to make me a Boiler Technician rather then an Electrician’s Mate. 😊
@idontthinkso666
@idontthinkso666 Жыл бұрын
I felt the same way, and they made me a Machinist Mate (Nuke) rather then an Electrician’s Mate.
@brianbuckley998
@brianbuckley998 Жыл бұрын
In my shop I ran two circuits in out 2 gang box, but each receptacle is a different circuit. The right receptacle is always one circuit the left is the other. That way I have separated power in every box.
@sapelesteve
@sapelesteve Жыл бұрын
Fantastic work Johnny! My stepson is an electrician, so I sent this video over to him for viewing. I have no idea what you were doing but it was interesting to watch nonetheless! Keep up the great work! 👍👍💥💥
@huntermccubbins8954
@huntermccubbins8954 Жыл бұрын
In a commercial buildings it better for the ground on the outlet to be facing up incase something plugged is hanging out just a little. If something metal falls on it it will hit the ground instead of the hot and neutral. Most new construction commercial buildings spec it in the plans.
@macxgeek
@macxgeek Жыл бұрын
I know this is true in hospitals but I would still do the way he did because I think it look upside down otherwise
@chanceltw
@chanceltw Жыл бұрын
The code is not applied retroactively. Once the 2020 (or newer) NEC goes into effect in your area, you won't be required to add those GFCI breakers to your existing 240V circuits if you don't want to.
@Meyerwoodworks
@Meyerwoodworks Жыл бұрын
I added a 125A sub-panel to my garage/shop. Two things I wish I did differently for anyone who is thinking about doing the same: 1) Go bigger on the conduit than you think. When doing 220, each outlet has to be a dedicated circuit, so you have a LOT of wires to pull. The conduit quickly fills up and it makes it difficult to pull. 2) I used 12awg THHN because I only needed 20A outlets, until I needed 30A.... now I wish I would have just ran all 10awg. If I would have ran all 10awg, I could have swapped one of the outlet 20A plugs for a 30A instead of having to run all new conduit/wire for ONE 30A tool.
@Jraksdhs
@Jraksdhs Жыл бұрын
No reason each outlet has to be dedicated unless you plan on running multiple machines at once. I recent built my shop with single and three phase via a large rotary. I have 4 50 amp welding outlets around my shop depending on what I’m doing. I’ll never be welding at more than one location and I’m the only person who will ever be working in there. Just plan accordingly and you’ll be fine.
@Meyerwoodworks
@Meyerwoodworks Жыл бұрын
@@Jraksdhs I guess if you're by yourself you are fine, but I still wouldn't do it for the next person. I work with another person and often run the dust collector, CNC, vac table, laser and other tools all at the same time, maxing about 120A at one time (tool rated, not actual measured draw).
@soisaidtogod4248
@soisaidtogod4248 Жыл бұрын
Hire a skilled tradesperson.
@idontthinkso666
@idontthinkso666 Жыл бұрын
Future proof, baby!
@idontthinkso666
@idontthinkso666 Жыл бұрын
@@soisaidtogod4248 Hire a skilled tradesperson, says the tradesperson looking for work.
@montgomery.metalworks
@montgomery.metalworks Жыл бұрын
I recently built my shop and all 110 breakers had to be GFCI at $60+ each vs $7... the cost of them is crazy.
@Belg1970
@Belg1970 Жыл бұрын
Probably Arc fault breakers not just gfi.
@soisaidtogod4248
@soisaidtogod4248 Жыл бұрын
That's 120V /240V . There is no110V. LOL yank education.
@EPortillo5000
@EPortillo5000 Жыл бұрын
About those face plates the tabs that you breaked are threaded to match the screws that come with the gfci outlets, installed one of those today.
@carolwilliams9a0
@carolwilliams9a0 Жыл бұрын
Hello 👋
@LilahLily87
@LilahLily87 Жыл бұрын
Wow, so I just had to have a whole bunch of electrical work done in my house. They didn’t have enough electricity coming into the house and so they had to redo my entire electrical. They had to bring in bigger wires off the road and they had to replace my breaker box in order to bring it up to code. Apparently in Knoxville Tennessee, not far away from you you have to have arc fault breakers to be in code and let me tell you those are expensive!
@idontthinkso666
@idontthinkso666 Жыл бұрын
Yes, the arc fault breakers are becoming required everywhere now. They had to install them in our new addition. I had them swapped out after the final inspection. Why? They are hyper-sensitive. If you use a tool with a high starting amperage (miter saw) they nuisance trip.
@surferdude642
@surferdude642 Жыл бұрын
I've seen a few videos now of non electricians doing similar work, usually it's easy to find mistakes due to ignorance or non ignorance, but just being cheap or lazy. Not here, you look like you know what you're doing, and imo the workmanship is top quality and very professional. I'm assuming that the THHN wires and the mc cable are 12AWG. I did something similar, albeit at a smaller scale in my garage just to increase lighting and receptacle location convenience. You said that every other box is on a different circuit, but the first one has both circuits, one GFCI for each, and I think that's fine, just wanted to clarify. I would prefer to use the formed or molded metal boxes with rounded corners instead of those sharp edged ones. Otherwise, great job.
@IWasNoah
@IWasNoah Жыл бұрын
it’s easy to find mistakes so many code violatiovs
@EPortillo5000
@EPortillo5000 Жыл бұрын
As always great video, just an observation, I usually see the installers put the conduit on the floor and put force on the handle of the bender, seems to be easier that way.
@fredericrike5974
@fredericrike5974 Жыл бұрын
A note on grounding modern tools and equipment, particularly if it has electronics involved- electronic circuits can easily fault if they lose positive contact with a solid ground. Anything from a service interruption to an expensive tool repair can result. Your belt and suspenders approach will get smiles from your inspector- they are quite used to people attempting to scrimp out any saving they think they can! It may save your life one day, to boot! It's gonna be great! FR
@brayton6683
@brayton6683 Жыл бұрын
What's your plans with the two air compressor you have sitting at the back of your shop will you be running solid air lines around your shop?
@thora3980
@thora3980 Жыл бұрын
WHAT, someone from the US that uses WAGO. thats the wa-yto-go. Btw, loving this series. So interesting seeing how people from other countries do stuff.
@OriginalMomo
@OriginalMomo Жыл бұрын
Loving this series, man. ☕️
@casperunnerup
@casperunnerup Жыл бұрын
Can you get electrical panels in the US that accepts DIN rail components? Because those components seem to be a lot cheaper
@therapeutic-sawdust
@therapeutic-sawdust Жыл бұрын
I am a limited energy electrician here where I live when running conduit you are supposed to have a conduit strap within a foot of the box and one every 10 feet of pipe. Is that not a thing there ? It was NEC code last time I had to do code update class.
@PLATTpanthers51
@PLATTpanthers51 Жыл бұрын
It’s 3ft within a box/coupling and 10ft after that
@stargazer7644
@stargazer7644 Жыл бұрын
I'm curious to see how long those GFCI's last before you rip them out. My inductive power tools trip them constantly.
@ericfraser7543
@ericfraser7543 Жыл бұрын
5:28 I believe it is code for you to share the neutral wire for those two 120V circuits so long as the circuits were on opposing phases. I.E. you would install a double breaker and wire the hots for each outlet on each side of the braker and the neutral is shared. Each circuit would then be ensured to be on an opposing phase which 180 degrees out of phase from each other. That would ensure that the common neutral wire could never be overloaded with the maximum 20A current at any moment in time, in fact if current were drawn on both circuits alternating current on the neutral would cancel each other because they are 180 deg out of phase with each other. I am not an electrician, so you might want to check with your local codes first but it might save you some wire.
@kraken509
@kraken509 Жыл бұрын
This is correct but with short runs it’s just as easy to run 2. Box fill and conduit fill would be a main driver for me to share a neutral in a small install like this.
@danediz
@danediz Жыл бұрын
its 3 phase, so can you do 2 pole mwbc? even if you do, you have to scrap the gfi right??
@bobniles1928
@bobniles1928 Жыл бұрын
Metal conduit (as long as it complete) is still a compliant ground.
@Xoliul
@Xoliul 10 ай бұрын
Crazy how code seems stricter then in Europe in many ways, but then you are allowed to use multistrand wire, which is a big no here, for the chance of a strand to frazzle out and become exposed.
@billybike57
@billybike57 Жыл бұрын
You have many A+ talents! 😊
@Nikolaos34
@Nikolaos34 Жыл бұрын
Unfortunately 240V GFCI requirements are starting to catch up, garage circuits are first on the list - at least in my local jurisdiction. And 'garage' is fairly interchangeable with any interior space with a concrete floor. _You are the ground_ when standing on concrete. So you are correct to install GFCIs in your shop. And yea man they are not cheap. And that's not even scratching the surface of 2017+ NEC requirements. Between GFCI, AFCI, CAFCI, and dual function - manufacturers are raking it in right now. The real kicker, is that standard breakers have a recommended lifespan of 30-50 years. These new GFCI / AFCI breakers are only rated for about 15 years before replacement. Funny story, there's a lady who flips houses in a county next to us, all of the inspectors know about her. She passes the final inspection on a remodel, then rips all the AFCI breakers out and uses them on the next one. Replacing them with regular breakers once the inspection is clear. I honestly don't blame her, these new breakers are terribly sensitive despite being life saving devices.
@mariushegli
@mariushegli Жыл бұрын
I have nothing to say really, but I appreciate your content, and wish to help with the yt-algorithms.
@stijndesmet4811
@stijndesmet4811 Жыл бұрын
where I live in Europe, we're not allowed to use wago's with this type of cable. either solid core cable of this type with a piece crimped over at the end to keep everything together. That being said, the electricals are very different in every way.
@haphazard1342
@haphazard1342 Жыл бұрын
I was also wondering about using the stranded wire with the outlet push-in type connectors, I didn't think that was allowed.
@neiltessier3520
@neiltessier3520 Жыл бұрын
Did I hear that correctly you need a GFCI breaker along with a GFCI outlet?
@cotton77837
@cotton77837 10 ай бұрын
Question: couldn’t you use the same white neutral wire for both circuits if the breakers were fed from opposite legs of the main? I’m thinking the return currents in the neutral would subtract from each other which would make separate neutrals unnecessary. Or am I missing something?
@paulcoon5399
@paulcoon5399 Жыл бұрын
I noticed you have a Square D panel and breakers. I would recommend moving over to either a GE or a Seimens. When I worked as an electrician, I was called to work on several remodels after small house fires, and every one of them was caused by a Square D panel and breakers.
@DiverTrev
@DiverTrev Жыл бұрын
How did you size your diamond back tool belt? Like the size how did you figure it out and how’s it being by your belly button when bending forward like?
@JPToto
@JPToto Жыл бұрын
Nice work! Someone check me on this: Don't you use those pipe benders with the curve on the floor and the handle facing up so you can use the handle for leverage?
@noahboyd2186
@noahboyd2186 Жыл бұрын
It can be used in that orientation (for bending 90 degree bends or kicks usually) and used with the handle on the ground and the curved part (the shoe) in the air for other tasks where bending with the shoe on the ground is less convenient, like bending offsets. Personally (apprentice electrician here) I sometimes did my first bend in the air and my second bend on the ground so I could use a level to ensure the offset was even.
@JPToto
@JPToto Жыл бұрын
@@noahboyd2186 Fair enough, thanks!
@russrockino-rr0864
@russrockino-rr0864 Жыл бұрын
One of the nicest jobs I have seen from a non-electrician. You obviously did your research. Good job explaining the Delta-High-Leg Panel. I am one of those Electricians that always uses a ground wire in my conduit. The conduit after it ages and has been altered over the years, becomes very unreliable as an equipment grounding conductor, in my opinion. I have seen evidence of this many times in my career(loose fittings, corrosion, paint, grime, etc). P.s. those little tabs you broke off the metal cover plates are to be used as nuts to hold the devices. Thanks, Russ-Electrician from Oregon.
@craftedworkshop
@craftedworkshop Жыл бұрын
Thanks Russ, I appreciate that!
@JonathanFisherS
@JonathanFisherS Жыл бұрын
Have a question: Why aren't GFCI breakers a thing? Just seems a bit silly we put them on outlets... the wiring from the panel to the outlet isn't GFCI protected and it increases the unit cost of the outlets
@craftedworkshop
@craftedworkshop Жыл бұрын
There are definitely GFCI breakers, I just had some GFCI outlets leftover from a previous job.
@dan__________________
@dan__________________ Жыл бұрын
The whole time I am wondering why the wall is half painted.
@yossid422
@yossid422 Жыл бұрын
Holy crap Look who it is.
@jamespolucha8790
@jamespolucha8790 5 күн бұрын
Could you use pvc ? I’m doing this in my shed but already put up wood interior walls and don’t want to cut and run wires and boxes but I was thinking PVC would be easier
@raytaylor4089
@raytaylor4089 Жыл бұрын
As the UK and EU countries are all 240v for domestic could you order the european/UK version of the breakers as will be far more common and likely lower cost? 3 phase here in the UK is 440v so much higher voltage for industrial use.
@marist89
@marist89 Жыл бұрын
for the gfci circuits, why didn't you just put in a gfci breaker and run normal outlets?
@padraig437
@padraig437 Жыл бұрын
Is there a reason why you don't have all the left outlets on circuit 1 and all the right on circuit 2. I think that would better serve all your benefits you mentioned
@notsure7874
@notsure7874 Жыл бұрын
You can't run MC exposed where it's subject to physical damage FYI.
@GregsWorkshopOregon
@GregsWorkshopOregon Жыл бұрын
I'm glad to see you use EMT conduit and THHN. So many people on YT use MC for everything and it looks like crap. EMT is way more versatile too, just this afternoon I added two extra outlets to my EMT electrical system in the shop.
@CiprianGheorghe
@CiprianGheorghe Жыл бұрын
wago - W souds like V (like in victory); A sounds like in Apple; go sounds like in gold. They are a german brand, and in Germany W sounds la v link in Volkswagen
@macxgeek
@macxgeek Жыл бұрын
I guess these are finally legal in the states. They're probably better but I still stick with wire nuts and tape. I should probably get with the times and start using these
@CiprianGheorghe
@CiprianGheorghe Жыл бұрын
@@macxgeek wago is way more versatile in different conditions, and 90% faster, wago has an entire ecosystem like, gelbox for waterproofing, different mounting plates and clamps, different distribution boxes and more. I'm not sure how many of their produs are right now in USA but in Europe is wideli spred. The competitor for wago si OBO
@quasistoic-all-in
@quasistoic-all-in Жыл бұрын
When did NEC change to start requiring a separate ground wire inside EMT rather than just bonding the EMT to use the conduit run as a ground path? Asking because I have a similar project I’m starting and I can’t find any references to a code change that disallows using the conduit as a ground path. Edit: This comment was in reference to the statements at 2:50 around the ground wire between the main and subpanels. I suppose it would make sense to treat that separately in code compared to the receptacle grounding you do address later in the video, and which is more applicable to my own projects. Would still love to have a reference.
@GibClark
@GibClark Жыл бұрын
Doesn't in between receptacles, codes a minimum, good quality work requires it. Conduit becomes corroded, gets beat around, comes loose over time. Good ground path is essential.
@rusty_restorations36
@rusty_restorations36 Жыл бұрын
Dedicated ground is not required in my area either. However i experienced an energized conduit due to a piece of equipment that failed to ground. leakage voltage that would tickle but, nothing harmful. Still enough to make me run a dedicated ground whenever possible.
@macxgeek
@macxgeek Жыл бұрын
It's just good practice to have a dedicated ground. In some areas even a sub panel requires a dedicated grounding rod as well, not just a ground back to the main panel.
@kevinbelcher8490
@kevinbelcher8490 Жыл бұрын
Could you run a dedicated outlet for the dust collection system?
@austinward558
@austinward558 Жыл бұрын
Can you do an update video on your upload schedule and plans for the channel. I’m confused on the content your doing at this time.
@EvanDunville
@EvanDunville Жыл бұрын
Nice work!
@gutzb4ll
@gutzb4ll Жыл бұрын
My dude, use a 240 breaker and share the neutral for the two outlet circuits
@MrDeni3d
@MrDeni3d Жыл бұрын
I know you’ve been busy with traveling and getting over being sick. But my man, I need more videos ASAP!
@josephlareau5726
@josephlareau5726 Жыл бұрын
Per NEC 250.118(2)(3)&(4); Rigid, IMC, and EMT are still acceptable equipment grounds
@josephlareau5726
@josephlareau5726 Жыл бұрын
however, if use a concentric knockout(multi size knockout) on your panel and don’t use the full size hole, you need to have a grounding or bonding bushing on the connector inside the panel and tie a ground from that bushing to the ground bar.
@mtnbikeman85
@mtnbikeman85 Жыл бұрын
Does your Klein meter's auto off and "I'm on" warning beeps drive you nuts? I have a cl 300-something and I figured out how to turn it on without the auto off, which is too short(like two minutes long.. power it on while holding SEL) but it still beeps all the time which is obnoxious for continuity testing. Any ideas? I'm about to just buy a Fluke because it's so annoying.
@milt7348
@milt7348 Жыл бұрын
Stay safe.
@jamesipad204
@jamesipad204 Жыл бұрын
I would of crushed this job, you should of hired me. For not being a sparky you did pretty good job, but the ac90 to emt is painful to look at. I
@BunderChowed
@BunderChowed Жыл бұрын
7:05 Bender Bending Rodríguez
@jmonsted
@jmonsted Жыл бұрын
Over here in Europe, we just GFCI the entire panel so everything down stream can just be standard breakers.
@johnowens178
@johnowens178 Жыл бұрын
That’s interesting. So the main service breaker (say 200amps) is a GFCI breaker?
@SilverEagle83
@SilverEagle83 Жыл бұрын
200A 😂 most places in Europe has 3 phase supply (even domestic) and 230/400V so we don’t need that many amps. And we don’t need so thick wires. A common house in Denmark has 25/35A main fuses typically 😁
@JockeData
@JockeData Жыл бұрын
@@johnowens178 You have a separate main service breaker and GFCI here. In older buildings where GFCI was first beeing used, you only had one GFCI for the whole breakerbox. So if it tripped, your whole house would go dark. Today you usually section them up, so lights go on one, and outlets on one. But id still say you dont have more then maybe four GFCIs for a standard house.
@w2ttsy670
@w2ttsy670 Жыл бұрын
Similar to Australia. You have two options: RCD + up to 3 same purpose MCBs for a block of circuits or RCBO (which is RCD and MCB in one) for each circuit. There is an option to get an outlet with an RCD attached if it’s not feasible to protect at the switch board. Also noteworthy is that we split lighting and general power onto different circuits rather than sharing the same wiring for both like in the US.
@DreitTheDarkDragon
@DreitTheDarkDragon Жыл бұрын
Since some people decided to use only one CFGI for entire house, there are new decrees which require you to have separate CFGI for almost everything (great, now my panel is too small again!).
@jimrumsey8077
@jimrumsey8077 Жыл бұрын
Couple of things. The raised covers are designed for you to use the screws from the device into the tabs you broke off of the cover. mc cable is not allowed to be run exposed. It still must be protected
@haphazard1342
@haphazard1342 Жыл бұрын
He's installing a drop ceiling, which counts as "enclosed" for MC cable.
@grayman74
@grayman74 Жыл бұрын
False. Mic is acceptable.
@Dachamp2001
@Dachamp2001 11 ай бұрын
Why 2 gfci outlets. One would work along as it's 1st in line?
@ingentingbra
@ingentingbra Жыл бұрын
American standards are weird. In Sweden we use blue for neutral, green/yellow for ground and brown, black and grey for phase.
@nataliemoseley9538
@nataliemoseley9538 Жыл бұрын
Would it be easier in the long run to number the boxes 1 that have one circuit and 2 that are on the other just for reference?
@daveklein2826
@daveklein2826 Жыл бұрын
Looks like he knows what he is doing
@sh2697
@sh2697 Жыл бұрын
for the ground bar you put in, does my box have to have been grounded to. a rod already?
@surferdude642
@surferdude642 Жыл бұрын
Check with local codes, but normally only the main panel needs a ground rod if the sub panel(s) are in the same building. A detached building would require a separate ground rod.
@YoungandReckless5468
@YoungandReckless5468 10 ай бұрын
So can Romex be used in emt if I’m doing electrical in my metal building at my house? Or do I need to use thhn wire
@craftedworkshop
@craftedworkshop 10 ай бұрын
Technically, but you have to size the EMT up a ton, plus it’s a pain to pull Romex through EMT. I’d definitely recommend THHN.
@leomuis9630
@leomuis9630 11 ай бұрын
Test was working
@kimaho8391
@kimaho8391 Жыл бұрын
Love de videos
@C_Squared
@C_Squared Жыл бұрын
You should have powered each outlet in each box with a separate circuit instead of every other box on a different circuit. Left circuit a and right circuit b
@kevinjmoore2359
@kevinjmoore2359 Жыл бұрын
The grey colored wire is used for a neutral in a 480V circuit.
@daveklein2826
@daveklein2826 Жыл бұрын
So?
@jonathanflynn618
@jonathanflynn618 7 ай бұрын
isn't that too many wires for the 3/4 conduit?
@khaledrjoub
@khaledrjoub Жыл бұрын
You should use something called anti-short bushing at the end of any MC cable otherwise it's a fire hazard
@sethprofitt
@sethprofitt Жыл бұрын
Wrong
@haphazard1342
@haphazard1342 Жыл бұрын
It depends how the MC cable is terminated. Some terminations screw inside the MC and replace the bushing.
@customsolutions7167
@customsolutions7167 Жыл бұрын
Who needs a gfci 240v breaker... 😂😂
@michaelstacey3830
@michaelstacey3830 Жыл бұрын
a good practice to consider is instead of putting wires on the load side wire nut them together with a pig tail and put all of your gfcis on the line side because if one gfci trips the rest down the line will trip also
How To Install A 240V Outlet | WORKSHOP RENOVATION 17
16:20
Crafted Workshop
Рет қаралды 161 М.
How to bend and install electrical conduit
20:14
Bob Clarizio
Рет қаралды 1,3 МЛН
HELP!!!
00:46
Natan por Aí
Рет қаралды 69 МЛН
They Chose Kindness Over Abuse in Their Team #shorts
00:20
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 59 МЛН
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,5 МЛН
Add Outlet To Unfinished Basement Or Garage
14:16
Everyday Home Repairs
Рет қаралды 1 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,6 МЛН
Electrical Outlets (Re)Install - Workshop EMT & Outlets
11:32
Rusty Rock Woodcraft
Рет қаралды 4 М.
#1 DIY Electric Mistake - Can you use Romex Wire in Conduit?
3:44
Silver Cymbal
Рет қаралды 1,1 МЛН
ROMEX Cable Support Requirements (2024)
11:38
Backyard Maine
Рет қаралды 314 М.
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 221 М.
Why Romex Doesn't Belong in Conduit: Quality and Longevity
6:20
abrelectric
Рет қаралды 72 М.