You've Been Installing Home Flex Gas Pipe Wrong This Whole Time

  Рет қаралды 42,043

The DIY HVAC Guy

The DIY HVAC Guy

4 ай бұрын

1/2" 35ft Home Flex: amzn.to/3SU5cWA
3/4" 35ft Home Flex: amzn.to/438claN
3/4" Home Flex Connector: amzn.to/3STpUWv
Round File: amzn.to/3wAZfGw
All my favorite HVAC tools: www.amazon.com/shop/thediyhva...
#1 Source for HVAC equipment: hvacdirect.com
Use my discount code 1MJTDLG4GM70 for an extra 3% off!
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a low price of $200, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/qYEa1J0knccjlwe...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com/@diy.hvac.guy?...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

Пікірлер: 122
@synisterfox
@synisterfox 4 ай бұрын
I would actually recommend using a deburring tool over the file for cleaning up that lip on the flex pipe. Takes just a few seconds and gives you a clean edge. EDIT for clarification: A hand deburring tool, not the kind you put on a drill.
@lambition
@lambition 4 ай бұрын
You must ground gas pipe when using CSST gas line. Make sure you have ground bonding wire to gas line. The reason is when lightning strikes, arc can jump between grooves or nearby grounded object and punch a hole through thin CSST.
@lrc87290
@lrc87290 4 ай бұрын
I think there is a black CSST that is arc safe
@lambition
@lambition 4 ай бұрын
@@lrc87290 that is made for exterior uses, but I believe it still requires ground bonding. Not exactly sure though.
@MK-xl9tt
@MK-xl9tt 4 ай бұрын
I’ve seen it first hand house was struck by lightning and a 12-2 wire was touching the trac pipe, burned a bee bee sized hole right through the pipe. Luckily the homeowner was there and smelled the gas right away.
@lambition
@lambition 4 ай бұрын
​@@bluejay713​ it just needs to be bonded somewhere within the system. Doesn't have to be at the meter. When CSST is added after drywall is on, bonding is usually done at or near CSST transition to make ground bonding visible for the inspector.
@lambition
@lambition 4 ай бұрын
@@bluejay713 If the gas pipe was bonded to ground when the house was built, then it usually will be at the point of entry. Gas meter is usually outside around here and never seen gas pipe bonded outside. It probably is because pipe outside is painted. If the meter is inside, then I have seen them grounded there since it is the point of entry.
@talon0863
@talon0863 4 ай бұрын
I like the trick of rolling over the sharp edge. That way the packing gets compressed not sliced. Maybe I missed it but I didn't see any sediment traps.
@1982nsu
@1982nsu 4 ай бұрын
08:10 Absolutely spot on. There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time."
@garbo8962
@garbo8962 4 ай бұрын
Only took my electrician self about 40 years to learn the correct term for what you called the vallies. Guy from UL labs told us for type AC ( BX ) & MC cable they are called convolutions And yes that & $2 or 3 will get you a cheap coffee..
@Honestandtruth
@Honestandtruth 4 ай бұрын
I Prefer using Black pipe for Natural Gas than the Flex gas tubing. It's more secured tight seal
@lnk4328
@lnk4328 4 ай бұрын
Agree 100%, but measuring, cutting and threading steel pipe actually requires knowledge, skill and a bit of work. Exact opposite of the state of this country.
@bignicnrg3856
@bignicnrg3856 4 ай бұрын
Do you still you use an out house to take a shit? 😂😂😂 mehh technology. Get off my lawn 😂😂😂
@jeffreyplumber1975
@jeffreyplumber1975 2 ай бұрын
looks neater too less likely to get damaged, cheaper. bonding electricly flex looks horrid but its faster. nothing wrong with it I just prefer the black
@timbrown9305
@timbrown9305 4 ай бұрын
When filing never let your filings fall inside your gas line (or any line). You have regulators down line that won't like that. (pressure regulator not a person).
@gallowaylights
@gallowaylights 4 ай бұрын
@timbrown9305 * good point 🫠
@1982nsu
@1982nsu 4 ай бұрын
Another point. 11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@CanyonDavis
@CanyonDavis 4 ай бұрын
Thanks for teaching me so many things. Always look forward to your videos!
@1982nsu
@1982nsu 4 ай бұрын
BIG MISTAKE at 11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@denniszhaunerchyk6191
@denniszhaunerchyk6191 4 ай бұрын
You create awesome videos. Glad you go into details like how to make it flush with the fitting. But I think music is too loud. Please post more videos!
@a3skywarrior929
@a3skywarrior929 4 ай бұрын
Great presentation. If you can cover any coding issues and things like bonding/sediment traps. We had the same type of gaskets in aircraft... flanges with nicks or bad gaskets always leaked 👍
@garbo8962
@garbo8962 4 ай бұрын
Retired sparky and maybe 8 years ago at a continuing education class they told us that each manufacturer has thier own way of bonding their SS corrugated tubing. I had a friend that needed the new half ass of it installed on top of 2.5" thin base board that had dents in it from being hit with vacuum cleaner to be bonded. I called the city owner Gas Company and they told me that I only had to run a wire from copper water service to steel gas line preferably where pipes enter the house. Did that and it was approved but I think it would be safer to run a #6 or 8 guage solid copper wire from steel gas pipe to a fitting in tubing then to where it connects at other end. If it was my house would have insisted on schedule 40 steel pipe to be ran on top of baseboard. Was in a basement rec room to feed a corner gas fire place.
@everydaysolar
@everydaysolar 4 ай бұрын
Nice demo buddy 👊
@davidmerkrebs9967
@davidmerkrebs9967 4 ай бұрын
great pro tip (the file method ) for home flex Question what do you do about bonding the csst and if so can it be bonded to the water main which gets bonded to the service panel
@JAIEB0
@JAIEB0 4 ай бұрын
Would love to see you touch on the importance of grounding when using this type of material. Alot of DIYers follow your lead and they just don't know. To important to not mention
@munozinni
@munozinni 4 ай бұрын
Great 😌 😊video and great tips…Saludos!!! You have a great Sunday!!!👋😃👋
@davek6630
@davek6630 4 ай бұрын
All new homes, I connect to gas have black csst. It has a layer of rubber over the tubing, then a steel mesh over that and then the outer layer of vinyl covering. It is because of lightning protection and needs to be bonded to ground. I don’t believe Iowa, Nebraska or South Dakota allow the yellow on new construction. I’d be surprised any other state allows it. Lightning burns holes through it!
@keithosterkamp6207
@keithosterkamp6207 4 ай бұрын
In cases like that I use a crows foot wrench and snap it onto my regular torque wrench. Works like a charm
@genemyersmyers6710
@genemyersmyers6710 4 ай бұрын
Good video ,thanks.
@Bowhunters6go8xz6x
@Bowhunters6go8xz6x 4 ай бұрын
Good stuff but I noticed you don't have any "Sediment or Dirt traps" at your furnace, water heater on the gas lines. If the gas company ever works on your gas main in your neighborhood and dirt enters the main line or if rust is ever created on old pipes or from home repairs like running new lines those pieces of dirt (flakes of dirt and rust) will flow through you line and into your gas regulators on your water heater, furnace, etc. and can block and ruin them internally. The traps are very easy to make for a few dollars for pipe and a cap. From what i've read in some states they are mandatory when licensed repairs are done.
@salvadorcastillo1539
@salvadorcastillo1539 4 ай бұрын
Thank you very much for your videos, very,very helpful...
@1982nsu
@1982nsu 4 ай бұрын
BIG MISTAKE at 11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@andy-ti9zf
@andy-ti9zf 4 ай бұрын
you are a generous man!
@henryt9254
@henryt9254 4 ай бұрын
Prone to failure because it really depends on the person installing it. Doing it right and doing it half-ass is a very fine line here I'm not too sure trusting even pros to get the fitting correct without worrying any potential issues down the road.
@handykiddhe4778
@handykiddhe4778 4 ай бұрын
Get the stuff from Lowe’s. Has same washer but also an o ring for double the protection from leaks. Never let me down. Make sure to do proper grounding.
@ElPescadorTejano
@ElPescadorTejano 4 ай бұрын
You should really call a licensed professional when dealing with gas. Most other things I think a DYI’er can do. But when you are dealing with an extremely dangerous fuel; I would ⚠️ recommend you call a licensed plumber or propane installer. I’ve been in a gas explosion before and I’m telling you. The last thing you want to do is have your house go 💥 because you didn’t want to spend the 💰 for a pro. There’s a reason that certain things can’t be purchased by Joe Public and are protected behind a license. If you do your own work, please check several times before you leaving it, and check the entire gas system not just what you worked on. Nice video
@1982nsu
@1982nsu 4 ай бұрын
I agree. 11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@barfy4751
@barfy4751 2 ай бұрын
Yet you can buy a complete electrical service as a diy person. Just as easy to die or burn the house down
@sloppytypist
@sloppytypist 8 күн бұрын
torque spec. is a mis-print according to Home-flex, should be 62 foot pound for 1/2" and 3/4". 74 foot pounds for 1"
@kentemple6498
@kentemple6498 4 ай бұрын
Switching from electric range to gas soon. This may come in handy.
@gallowaylights
@gallowaylights 4 ай бұрын
Wish that came with a pressure drop calculator Qr code link printed on the pipe... make things easier!
@jayb6860
@jayb6860 4 ай бұрын
Did you get an inspection on your work? I’m sure it would not pass due to the issues discussed.
@yupsir791
@yupsir791 4 ай бұрын
Milwaukee knife! Be careful they like to evaporate away!! I am on my 3rd one.
@jimkane9832
@jimkane9832 4 ай бұрын
I was told that homeflex is not designed to be disconnected and reconnected and that it should have a union between the flex and the appliance
@Moondoggy1941
@Moondoggy1941 4 ай бұрын
Rigid Aluminum Offset wrenches are your friend.
@Shadi2
@Shadi2 4 ай бұрын
You forgot to bond the flex to panel ground with #6 wire. The reason is to provide a path for lightning current. You can use a nearby water pipe ONLY if the water pipe is bonded to PANEL ground. (use an ohm meter between the ground pin of an outlet and your pipe) kzbin.info/www/bejne/bYLMf4CkecmLh5o
@talon0863
@talon0863 4 ай бұрын
Thanks you beat me to it
@yzmoto80
@yzmoto80 4 ай бұрын
It appears to be the same guy that installed the black iron, also installed the electrical wiring.
@diyhvacguy
@diyhvacguy 4 ай бұрын
lol
@user-ug6ti3op3x
@user-ug6ti3op3x 4 ай бұрын
You do not have to install drip legs at the devices ?
@randymathews3348
@randymathews3348 4 ай бұрын
It's always great when someone says "you're doing it wrong" then proceed to do it all the way wrong
@1982nsu
@1982nsu 4 ай бұрын
I agree. 11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@briansmyla8696
@briansmyla8696 4 ай бұрын
@@1982nsu Drip legs aren't required any more.
@ElPescadorTejano
@ElPescadorTejano 3 ай бұрын
@@briansmyla8696 that’s not true. In my local jurisdiction here in College Station, TX the city enforces the sediment trap. We put it in or it’s a $100 red tag.
@briansmyla8696
@briansmyla8696 3 ай бұрын
@@ElPescadorTejano Local codes may require it, but I don't believe that the national code does. It's a relic from the days of wet, contaminated gas supply.
@briansmyla8696
@briansmyla8696 3 ай бұрын
@@ElPescadorTejano UPC uses the phrase 'other than dry gas conditions' for many requirements, including the requirement for a sediment trap. Which implies that dry gas conditions are assumed in most cases, and 'other than dry gas conditions' is a rare exception. Sediment traps are required by code only in 'other than dry gas conditions'. Dry gas is assumed and expected in today's gas delivery systems. 'Other than dry gas conditions' is a relic of bygone days.
@ericr2zz
@ericr2zz 4 ай бұрын
Great video! I think you need to support your expansion tank on your hot water heater. Hanging the unsupported tank on its side may not be to code.
@gallowaylights
@gallowaylights 4 ай бұрын
@ericr2zz * they sure get heavy when the bladder fails...🫠
@diyhvacguy
@diyhvacguy 4 ай бұрын
Will be replaced very soon with the tankless 👍🏼
@search_eternal
@search_eternal 4 ай бұрын
Are you putting in a 90+ furnace in?
@gallowaylights
@gallowaylights 4 ай бұрын
6" clearance on 3" flue for less than 28k btu with no rise at scoop?
@dustinkrebs8229
@dustinkrebs8229 4 ай бұрын
Do you have drip legs on the furnace, or water heater? I didnt see any...🤔
@diyhvacguy
@diyhvacguy 4 ай бұрын
Not yet, the furnace is getting replaced and the water heater isn’t fully installed yet. But there will be on both 👍🏼
@dustinkrebs8229
@dustinkrebs8229 4 ай бұрын
@@diyhvacguy I was curious. Good deal👍
@skyscraper37
@skyscraper37 4 ай бұрын
Interesting that the lip doesn’t cause issues like you would have if it were a water line
@gnic76
@gnic76 4 ай бұрын
I would think it is because gas is run at a lower pressure than water is. 🤷‍♂
@francisoconnor2392
@francisoconnor2392 4 ай бұрын
What type of venting material is on your furnace?
@diyhvacguy
@diyhvacguy 4 ай бұрын
Is a double wall flex vent that’s made for gas furnaces. I can’t seem to locate them online however. I get them through my local hvac supplier
@jamest-mk4qu
@jamest-mk4qu 4 ай бұрын
Great work. Like to see your use of crescent wrenches on large fittings. But at approx. frame 11:22 you held the fitting with a wedged crescent wrench but tightened the flex piping with slip-joint pliers. Would not a crescent wrench have been a better choice? At least you are not like some U-Tube plumbers that seem to use nothing but slip-joint pliers on everything. Even chrome plated fixtures in many cases.
@MrPoppyDuck
@MrPoppyDuck 4 ай бұрын
All the prep to use the flex line seems like it takes a lot of time. Wouldnt black pipe be faster to install?
@gnic76
@gnic76 4 ай бұрын
Black pipe is a pain and messy, unless you already have all the threading tools, fittings and can run it neatly to where you want it.
@diyhvacguy
@diyhvacguy 4 ай бұрын
Amen. I love the flex but to each their own.
@hughfixit
@hughfixit 4 ай бұрын
Why would anyone remove black pipe for CSST???
@natekry
@natekry 4 ай бұрын
Never done anything to the edge. Never been an issue.
@tommcqueen3145
@tommcqueen3145 4 ай бұрын
🤔 I Think you're supposed to have a disconnect / union in front of the shutoff valve it seems to me should of strapped it better 👍
@sharpshooterofky
@sharpshooterofky 4 ай бұрын
Can Plex tolerate say a mouse chewing on it?
@robertking5766
@robertking5766 4 ай бұрын
I think i would of pressure tested it with air first you ever know if there's a pin hole in the tubing
@bigblue2216
@bigblue2216 4 ай бұрын
National Grid does not allow the Flex gas pipe. I was red flagged for it. The reasoning, I was told, is lightning strikes can cause pin hole leaks... I pressed X to doubt.
@gallowaylights
@gallowaylights 4 ай бұрын
Bonding? Some require ground wire to water lines, gas line and electric panel... flash shield?
@bigblue2216
@bigblue2216 4 ай бұрын
@@gallowaylightsWater line grounding isn't even legal for the cable company. They inspected my utilities, Red flagged the items and said see ya. I think it was a liability release for the company, they won't re-inspect after I fixed the issues.
@gallowaylights
@gallowaylights 4 ай бұрын
@@bigblue2216 it's so interesting how everything is connected together... at the pannel (neutral and ground), at that 3' rod into the ground "earth ground" at gas and water lines "bonding" at a light bulb "filament" in a pinched wire "short" etc.
@MrPoppyDuck
@MrPoppyDuck 4 ай бұрын
I too was wondering if felx pipe is allowable everywhere.
@gallowaylights
@gallowaylights 4 ай бұрын
@MrPoppyDuck * nail guards... non moble applications... none corrosive environment... everything has pro and cons..
@mikewhittaker5984
@mikewhittaker5984 4 ай бұрын
Heater valve is useless where you placed it .
@diyhvacguy
@diyhvacguy 4 ай бұрын
Um how so?
@Dimka2
@Dimka2 4 ай бұрын
dang that mechanical room looks like a mess, it doesnt seem like it would be that much harder to do normal black pipe, or pro press gas connection
@kennylavay8492
@kennylavay8492 4 ай бұрын
NO to pro press
@leiferickson713
@leiferickson713 18 күн бұрын
No offense but I can’t believe what code allows for gas today. yeah I see it all the time in the big houses that we wire. Just seems so unsafe.
@HappyQuailsLC
@HappyQuailsLC 4 ай бұрын
I never heard "ovular" before... guessing it means oval?
@diyhvacguy
@diyhvacguy 4 ай бұрын
Yes
@tunafish3216
@tunafish3216 4 ай бұрын
It looks to me that it takes 4 times as long to install this stuff. Not to mention the cost.
@diyhvacguy
@diyhvacguy 4 ай бұрын
The primary reason I wanted it was for that long section that goes out to my back deck and garage. That would have been a royal pain to do in black pipe.
@JACK-wh6jl
@JACK-wh6jl 4 ай бұрын
goof !
@diyhvacguy
@diyhvacguy 4 ай бұрын
Helpful comment 👍🏼
@douglaswindsor120
@douglaswindsor120 4 ай бұрын
So is this ss how does this pipe and fittings compare to the pipe and fittings the gas fiters use flex pipe looks the same but the fittings are different as the ones the plumber use the pipe goes inside the coupler and the ring is 2 half parts of the ring also the flex pipe is stainless steel with the plastic cover on it you say they can be bought online can you also buy the professional fittings online as well
@daveinvictoriavirginia7959
@daveinvictoriavirginia7959 4 ай бұрын
Bonding a CSST line is imperative, not grounding. Any appliance that functions by thermostat, must have sediment trap. Any gas line longer than 1 foot must be pressure tested via air or non-flammable gas like nitrogen (minimum 15 psi). CSST line has started many house fires ! This is not a place to DIY.
@DWit-zn2oh
@DWit-zn2oh 4 ай бұрын
I don't think DIY guy knows bonding.
@DWit-zn2oh
@DWit-zn2oh 4 ай бұрын
Does not have to always be done at the meter..
@tomatexelon
@tomatexelon 4 ай бұрын
I prefer black pipe over a bunch of extension cords like you have here. Flex line like that is really should be used for behind a gas stove or from the hot water tank to black pipe, which is less than 2 feet. Also at 9:45 you were filing and getting all the debris inside the flex line gas line. You should be doing it a better way.
@jimpie231
@jimpie231 4 ай бұрын
People have problems putting in black pipe with gas, this would be harder. I have seen plastic pipe used underground to swimming pool heaters, but only outdoors never inside. I would never have this in my home, I couldn’t sleep at night……..
@anthonyhitchings1051
@anthonyhitchings1051 4 ай бұрын
your soapy solution for leak detecting is too thick
@1982nsu
@1982nsu 4 ай бұрын
08:10 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time."
@user8ZAKC1X6KC
@user8ZAKC1X6KC 4 ай бұрын
Did I miss the part where he bonded it or is his house going to explode?
@DWit-zn2oh
@DWit-zn2oh 4 ай бұрын
I don't think DIY guy knows bonding...
@MK-xl9tt
@MK-xl9tt 4 ай бұрын
Yeah you gotta ream it and ground it. That’s why you’re supposed to be certified to run the stuff. When it first came out we ran it like wildfire, now that I’m calling the shots we run all hard pipe. Was never a fan of it.
@above7833
@above7833 4 ай бұрын
Code requires Gas lines be black pipe, ONLY ! NO Galvanized pipe or galvanized fittings should b used at all !
@1982nsu
@1982nsu 4 ай бұрын
11:21 There's no sediment trap. Elbow needed to be a "tee" fitting. So much for the title of this video "You've Been Installing Home Flex Gas Pipe Wrong This Whole Time." Same mistake at 08:10
@TB-LivingFree
@TB-LivingFree 4 ай бұрын
ThumbItUp &LeaveAnyComment 4AIgozAll
@jaxsonhugh9334
@jaxsonhugh9334 4 ай бұрын
There are so many NO NOs with this install…..
@diyhvacguy
@diyhvacguy 4 ай бұрын
Let’s hear em. This comment is kind of useless otherwise
@domenicdalleva1045
@domenicdalleva1045 4 ай бұрын
Sorry not a good idea to put flex in 😟
@diyhvacguy
@diyhvacguy 4 ай бұрын
Umm why?
@edwardbruno521
@edwardbruno521 4 ай бұрын
Nope you didn't I didn't see any sediment trap
@mechanictaft4848
@mechanictaft4848 4 ай бұрын
Yea that crap is banned most places and you must have drip legs look up code im too tired 😫 to explain .
@diyhvacguy
@diyhvacguy 4 ай бұрын
Yes, I explained that the new furnace will go in in a few weeks and will have a drop leg. As will the tankless water heater.
3 Ways to Plumb for Gas with Master Plumber Eric Aune
10:50
Matt Risinger
Рет қаралды 27 М.
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 532 М.
Fast and Furious: New Zealand 🚗
00:29
How Ridiculous
Рет қаралды 45 МЛН
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 107 МЛН
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 482 М.
92% of Homeowners Use Teflon Pipe Tape Wrong - Here's Why it Leaks
5:33
Silver Cymbal
Рет қаралды 2,8 МЛН
Hooking Up A Quick Disconnect To Your Natural Gas Stub
3:24
BBQ Concepts
Рет қаралды 19 М.
How to Assemble the HOME-FLEX CSST Fittings
4:33
Valencia Pipe Co
Рет қаралды 49 М.
This Tool Changes EVERYTHING.
20:07
The DIY HVAC Guy
Рет қаралды 128 М.
Natural Gas BBQ Grill Gas Line Install
8:13
Pros DIY
Рет қаралды 458 М.
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 826 М.
FINALLY installing HVAC in my SHOP!!
32:28
Quality HVACR
Рет қаралды 22 М.