I'm also used to picking up fashionable and discounted bags from kislux , and to be fair, I don't think there's anything wrong with individuals choosing to buy fakes for personal use, so it's not necessarily a bad thing, it just gives us a choice
@forzajuve484524 күн бұрын
they made an elaborate bowling bag
@JohnDundee-el2ro26 күн бұрын
Naw I would have took a 2 x 2 plastic trunking right along the top right round and along the joint in your wood to the door then mounted the CU up against the trunking dropped conduit out trunking to light switch and dropped conduits down to sockets the 2 way switch at far end not needed I would have used surface white PVC boxes they don't break also white conduit switches and sockets and singles not T& E cables also 1 100 amp DP main switch 1 32A RCBO 1 20A RCBO and 2 6A RCBOs it would have looked better
@JBE26 күн бұрын
Yeah great idea cheers for watching. I have re-jigged the electrics a little since this video. Still, my original layout is good for me 👍🏻.
@AncientChi26 күн бұрын
Bosch radio is better anyway
@AltangerelZerar28 күн бұрын
The materials used are top notch. The leather feels soft and luxurious, exactly like the real thing. The stitching is impeccable, with no loose or uneven lines. The hardware (including the iconic CC twist lock clasp) is durable, well made, and adds to the overall elegance of the bag kislux . I thought everyone who owned an LV monogram bag knew that it was obviously coated canvas? When people spend a fortune on an expensive bag, they might as well buy a replica
@JBE28 күн бұрын
@@AltangerelZerar Merry Christmas 🎅🏻
@richardcawreyАй бұрын
Sign of a good spark a brush in the bag
@JBEАй бұрын
@@richardcawrey Always cleaning up after other trades 🤣
@three-phase562Ай бұрын
I have been thinking about one of these for my motor maintenance loadout, being able to put the meters in one side and then the mechanical handtools in the other side. Even have one of the small organisers clipped underneath to hold consumables.
@JBEАй бұрын
@@three-phase562 Sounds the perfect bag for you?
@lightbulb6293Ай бұрын
I like saying "Milwaukee Closed Tote Bag" 7 x fast 😂😂😂😂 🎒
@lightbulb6293Ай бұрын
You cut your finger about 25 minutes in matey? Did you forget to "cut that bit out?" 😂😢 🩸 Thanks for the long proper video. Nice to have you back and this proper review! 👌
@JBEАй бұрын
Yes, I even bleed for these reviews. I hope you watched the whole tool ramble? This bag is growing on me and is a beautiful addition to the Packout family.
@PupchippАй бұрын
Oh ..so the high pitch whistle I hear is a tester...I thought it was part of the loud music.
@olly7673Ай бұрын
I missed this when it first came out but enjoyed it belatedly, so thanks James. I see the circuits 1 to 6 on the earth bar correspond to the circuits and I presume the gas and water bonding are in 8 and 9 but can I ask what are 9 and 10 relating to mucker?
@John12369Ай бұрын
Someone correct me if I’m wrong. Apart from cable size. If he wired it in a 6mm instead of a 2.5 it would be fine????
@peterigrenyi9176Ай бұрын
What safe zones...
@MADSPARKS31Ай бұрын
Nice job, dont let that fire foam touch the cables.
@marksimpson3035Ай бұрын
Why why why why ehy why 😂
@marksimpson3035Ай бұрын
Exclusively at Marks & Spencer's 😧
@trying-hard-1112Ай бұрын
Wow!! This has to be a joke surely!! I teach electrical installations at college and i will for sure be using this in what not to do or spot the difference between a proper job.
@KetamineUpUrAss29 күн бұрын
But are you a spark?
@matasdaugnoras8430Ай бұрын
Mate is that a joke or it works properly ? Deos it slides into slot as it should ?
@AnthonyKuder-q8vАй бұрын
But how much is it worth??????
@lesliecone9034Ай бұрын
me 😂
@darrenelkins5923Ай бұрын
My understanding is you cannot retro apply regs? So would no RCD be a case of that on rewireable fuse? Similar extension lead use might be advice, but I thought it is considered as temporary and does not produce an EIRC fail? Thanks
@karlstewart22202 ай бұрын
When you think you've seen it all
@BestEDMSongs2 ай бұрын
What was the cost to replace mate ?
@JBE2 ай бұрын
@tach175 I can't possibly comment as the company paid. A board swap/upgrade these days can be anything from £300 + materials to £800 + materials. Apparently there's one electrician in Cambridge who wants £800 just to turn up, however he does have lots of debt to pay for! Just don't get some "guy who knows electrics" to do it. Safety first...then quality 👌🏻.
@Brucey3672 ай бұрын
Sorry boss. I needed to get down the pub quick sharp.
@keiththesparky2 ай бұрын
A nice tidy mains board swap to the chilled out love god that is Barry White what more could one ask 😂
@JBE2 ай бұрын
@@keiththesparky I wish they were all this chilled out. It'll sit here now for another 30 or 40 years until some new reg makes them obsolete 🤔🤣
@garethwatson79992 ай бұрын
Hi mate, what did you do regarding those air gaps (open soffits) as I presume you’ve insulated your workshop before boarding it out? !
@Brown9692 ай бұрын
If only it took 3 1/2 minutes in real life, we could do at least two of those a day. 😂😂 Tidy work, well done 👍👍
@gd-bq7em2 ай бұрын
Hi mate was the lighting circuit live and cpc together and the neutral a separate cable
@AndyK.12 ай бұрын
Nice to see a wylex for a change. Twin screws in the main switch. Nice.
@JBE2 ай бұрын
@@AndyK.1 It's all we fit here 👍🏻
@delspark2 ай бұрын
nice would of stated the grommet strip in the middle 🙂
@dlh1902 ай бұрын
C3?! 😄
@JBE2 ай бұрын
@@dlh190 C3 all day 🤣
@quickkwack2 ай бұрын
Nice job, where did you get the black grommet strip from?
@JBE2 ай бұрын
@@quickkwack CEF👍🏻
@quickkwackАй бұрын
Sorry to be a pain do you know what tbe CEF part number is for the grommet strip is @JBE
@alvina692 ай бұрын
Hmmm…. Not sure about fixing the shower isolator there, there’s clearly second isolator further down the line.
@JBE2 ай бұрын
Yeah but no one really cares when Barry comes out 😎
@williamsdaduk2 ай бұрын
that busbar!
@Richardincancale2 ай бұрын
Watched to the very explosive end!
@Blitterbug2 ай бұрын
A work of art, Mr B. I'll even forgive the Barry White.
@audibell2 ай бұрын
oh deer
@alvina692 ай бұрын
Whoever done that board, has no idea what they’re doing… That neutral coming out of the top of the main switch is doing absolutely nothing, there’s already a neutral on the bar from the switched side of the switch… Can’t locate and rectify an earth fault so removes the RCD’s to keep the power on 🤦🤦🤦
@analysisreporting59222 ай бұрын
I see you admiring my handy work. 😂😂
@JBE2 ай бұрын
@analysisreporting5922 I don't think we'll ever get to the bottom it, tenants probably did it?
@ULICKMAGEE2 ай бұрын
Some Gerryatrick
@alvina692 ай бұрын
Not a single screw and plug even in the grout line 🤦🤦🤦