Thanks for sharing this , I’ve replaced lots of this type of thermal overload but never had a look inside one . Great video 👍🏻🇬🇧
@razenby9 ай бұрын
Thanks for watching! The ones inside electric showers fail often.
@Paul-wv2im9 ай бұрын
Another great video to keep my dryer working at low cost! Thanks.
@razenby9 ай бұрын
I went to the municipal dump yesterday and looked at the machines there. It is shameful how good some of the appliances are and I bet most of them just need a bit of TLC and a few cheap components. The alternative is mining, pollution, more plastics and what for?
@zx8401ztv9 ай бұрын
Well done, well worth fixing :-D A decent quality machine and it was very cheap. I've seen those thermostats/cutouts in fan heaters/washing machines and tumble dryers.
@razenby9 ай бұрын
It is a really nice machine, it feels good quality inside.. very solid. Never seen one of those thermostats fail shorted but perhaps you never do as the house has probably burned down!!! Makes you wonder how the trigger temperature creeps over time..... Thanks for watching.
@desmond22502 ай бұрын
Great content 👏
@razenby2 ай бұрын
Thanks for watching.
@stephendennis78718 ай бұрын
I a man working on my AEG washing machine which would not power up. On inspection I changed the off line chip LNK364GN and the machine worked for about 2 months before the same fault surfaced again so I changed the LNK again but now the machine works until you power it off as normal but then will not power back up until you change the LNK chip again. Have you ever had this type of failure or can suggest where to look as chinging the chip every time I want to use it is not an option...lol
@stephendennis78718 ай бұрын
I should have added that the resistors were within range and also changed the 400v 22uf capacitor and the diode checked ok.
@razenby7 ай бұрын
Usually the LNK304GN does not fail without taking out several other components. They don't really go intermittent. They just blow their top or vent gasses. It could be that a dry joint on the controller is the root cause and the LNK chip was just a red herring and what fixed it was disturbing an bad connection. Have a look at my AEG EHO error repair video. You will see what to look for. Please like and subscribe.
@stephendennis78717 ай бұрын
Thank you for the reply and after watching your AEG tumble drier video you suggested I took out the control board again done another check but after seeing your video with the poor soldered joints I decided to resolder some although they looked good as a last ditch attempt......well the washing machine has powered up again so I am holding my breath in that it's now sorted....so thank you for the heads up in showing how AEG boards may have some poor soldered joints.
@willshingler53078 ай бұрын
I've replaced the thermostat twice now and it keeps blowing, so I now assume it's the controller on the board, do you know where the controller is situated on the board ? Thank you
@razenby8 ай бұрын
That is strange. Send me a picture listing or part number of the thermostat that you are using... ark.mail@gmx.com
@marcuswey18798 ай бұрын
Hi, I know you like a challenge. In the past, you helped me get my washer/dryer going again. Still running perfectly today. Eternally grateful. New problem. I have an obsolete electric wall heater controller that seems to have stopped working for no particular reason. Creda PWE4ZC has no display and seems dead. Any ideas?
@razenby7 ай бұрын
Hi Msrcus. Send me some detailed photos of the electronics Ill give you a good idea once I see it... ark.mail@gmx.com