good morning Brian, we just had our faulty heating element replaced . now we are trying to get it back to heat up.. code appeared Ecn (economic) and than ICE appears as well... what does ICE stand for?
@atlantahottubcenter6 күн бұрын
@@BettinaJanssen-v2l Good afternoon, I would put the hot tub in standard so it will heat correctly for colder weather. Economy is really designed for warmer weather. ICE will show on the display until you’re 20 degrees from your set temperature then the error will go away. Hope this helps!
@BobOlson-q4e3 күн бұрын
can you tell me what a SNS code means on my 2002 marquies reward tub?
@atlantahottubcenter2 күн бұрын
@@BobOlson-q4e The SNS error code means “Sensors out of Sync" this indicates that the sensors in a hot tub are not reading the same temperature. You’ll need to replace your sensors most likely but it could also be a board problem if the board isn’t recognizing the sensors. However, most likely you’ll need to replace the sensors. Hope this helps!
@BobOlson-q4e3 күн бұрын
can you tell me what a SNS code on my 2002 marquies reward hot tub is telling me?
@atlantahottubcenter2 күн бұрын
@@BobOlson-q4e The SNS error code means “Sensors out of Sync" this indicates that the sensors in a hot tub are not reading the same temperature. You’ll need to replace your sensors most likely but it could also be a board problem if the board isn’t recognizing the sensors. However, most likely you’ll need to replace the sensors. Hope this helps!
@stunz33d26 күн бұрын
What does Message Code 253 BT Failure mean? Thank you for the great videos by the way.
@atlantahottubcenter9 күн бұрын
@@stunz33d Good afternoon, flow switch or pressure switch failure. You won’t have both so either or. I would make sure your filter is clean first and give the hot tub a good reset by turning the breaker off for 30 seconds and then back on. Hope this helps!
@robertoamado81043 күн бұрын
What does a po3 code mean I have a St. Andrew hot tub about 16 years old. And it doesn’t heat past 90 degrees so the pump is always running.
@genetroy110 күн бұрын
Calfornia cooperage by coleman model 107 , code f3
@atlantahottubcenter9 күн бұрын
@@genetroy1 On a California Cooperage hot tub, an "F3" error code normally indicates that the filtration cycle is set to run for a specific duration, usually meaning the pump will run for 3 hours within a set time period as part of the filtration process. This isn’t really an error code. If everything working properly? Most of the “F” features are just different filtration cycle settings. Hope this helps!
@Tezzysgirl4 ай бұрын
have you got info on Spanet mini 2 heater problem trip, Spa world told us to elimantation process, due to our Fisher 5D spa tripping power on start up/ prime. we did that and are now having to pay for a new heater. even know its under warrenty!! they recommended a pump specilist in which we had come out, and he said it wasnt due to chemical inbalance, but they are saying it is… can we by pass the heater when we do a water clean/ balance?
@atlantahottubcenter3 ай бұрын
Good afternoon, you could bypass the heater on a drain and refill but then you wouldn't have any heat. The problem with these enclosed heaters is that you can't just replace the element. I am not a fan of this kind of heater or any component that can't be worked on because it's a replace only scenario. pH levels being off can corrode the heater and cause it to go bad. However, when they remove it you can look at the element and see if there's chemical damage or not. If you see white corrosion and it falling apart you'll know. Hope this helps!
@SRTpaytoplay2 ай бұрын
I have an E7 code on my hot tub. Also displays a 662 code. Any insight as to what is wrong?
@atlantahottubcenter2 ай бұрын
@@SRTpaytoplay Good morning, what brand hot tub do you have?
@joevicfabregas3966Ай бұрын
Temperature shows 99 and unable to adjust it any higher. the arrow is set to go lower but not higher. how can temperature be adjusted to 104?
@atlantahottubcenterАй бұрын
Good afternoon, sounds to me like your topside LCD display is going out and will need to be replaced. If you can adjust it down and not up then that would be my thoughts. Now, if you can't adjust it either way, the hot tub could be in temperature lock which holds the display temperature in place. Hope this helps!
@LisaHall-j3dАй бұрын
P51
@atlantahottubcenterАй бұрын
Good afternoon, A "PS1" error code on a hot tub typically indicates a problem with the pressure switch, specifically that the circulation pump is running but the pressure switch isn't registering proper water pressure, usually due to low water level or a faulty pressure switch itself; check your water level and inspect the pressure switch for any damage or malfunction. Hope this helps!
@maryalicemccrae875014 күн бұрын
Fd3
@atlantahottubcenter3 күн бұрын
Good afternoon, are you sure it's no f3? That would be a filter cycle setting. Please confirm. Thanks
@maryalicemccrae87502 күн бұрын
@ I am certain
@BillClark-n4p9 күн бұрын
L p fifty p seven hot tub , no command code
@atlantahottubcenter3 күн бұрын
Good afternoon, communication error, meaning the control panel is not receiving signals from the hot tub's internal components, often displayed as "no comm" or similar depending on the brand; this usually requires a fair amount of meter work to determine what the exact problem is with the topside control panel or circuit board. Hope this helps!