Basic Motor Control: Pump Panel Wiring - Part 2

  Рет қаралды 50,485

AccessToPower

AccessToPower

Күн бұрын

#accesstopower, #motorcontrol
In this video, we will look at a physical pump panel along with its schematic and we will explain what each of the components does and how they are wired. In the last video in this series, we went over a 3 phase pump panel and how a pump is controlled both in Auto Mode as well as hand mode. In Auto mode, the pump will start using a standard float switch that closes on rise. This would be typical of a sewage lift station. When the liquid rises the float normally open contact is closed, and the pump starts. In the Hand Mode, the pump waits for the start button to be pressed in order to run. Once running in hand mode, the Hand, Off, Auto switch must be turned to off for the pump to stop. In this video, we will focus more on the real physical wiring of the panel.

Пікірлер: 56
@tomk2471
@tomk2471 3 жыл бұрын
Awesome video, thanks for all the details ! Can’t wait for the next one👍
@gregoriocampo
@gregoriocampo 4 жыл бұрын
Thank you for your professional explanation .
@jessel2805
@jessel2805 2 жыл бұрын
very helpful video!! thank you very much!!
@jimmurphy6095
@jimmurphy6095 4 жыл бұрын
Very nice... How about a lead/lag pump setup? I see a lot of those.
@AccessToPower
@AccessToPower 4 жыл бұрын
Jim Murphy good suggestion. Thanks
@michaelcostello6991
@michaelcostello6991 Жыл бұрын
Lots of these pumps are controlled with small PLC and the float switches or pressure switch. Can you do a video on this.
@AccessToPower
@AccessToPower Жыл бұрын
I will try to do that. Thanks for the suggestion
@ericmaldonado1373
@ericmaldonado1373 4 жыл бұрын
Great video, if you get rid of the background music...it would be perfect 👍
@YUTENGHU
@YUTENGHU 5 жыл бұрын
very professional and knowledgeable, thank you for sharing your expertise
@MM-ov6uw
@MM-ov6uw 2 жыл бұрын
Your the best man ! Thank You for sharing the knowledge 🙏🏽
@mindaugasv85
@mindaugasv85 9 ай бұрын
3:12 2-phase 😉 4:00 by grounding you have lost protection... Without (!) ground it will work as isolating transformer, so if you will touch the control wire, you will not be shocked by voltage 😊
@ΙωάννηςΣιδεράτος
@ΙωάννηςΣιδεράτος 3 жыл бұрын
Great video! Thank you for all the support!
@nithyanandavenkatappa5416
@nithyanandavenkatappa5416 2 жыл бұрын
*Series connection* of smart motor controller to traditional (electro mechanical overload relay type)motor controller, which wired to *single/same pump set*. (Twin / *dual* motor controllers for the only one pump set), Then,What are the *pros and cons*/Hazards, due to this type of wiring connection?? #Please *clarify and comment*
@danschumacher5427
@danschumacher5427 2 жыл бұрын
Sensei
@SelinaAl-Shaer
@SelinaAl-Shaer Жыл бұрын
I love the way you take your time and explain the practice and the theory behind whatever it is you are explaining. Do you have any NEC code videos on you tube?? if not, I really think you should cover code videos. i know everyone watching you will be interested in Code tutorials. Thank you.
@AccessToPower
@AccessToPower Жыл бұрын
Thanks for your comment. I have a couple videos on the NEC for conduit fill and enclosures. Thanks for the suggestion to create more
@johnszott956
@johnszott956 4 жыл бұрын
Great video! I like how you incorporated both schematic and real video of panel box with you showing routings. Keep up the great videos!
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 2 жыл бұрын
True, it helps having both
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 2 жыл бұрын
Based in the UK but the principles from this video are still helpful. Thanks
@petersmith9254
@petersmith9254 5 жыл бұрын
Great explanation bro keep posting videos u b bigger than mike holts
@viswanathaniyer2372
@viswanathaniyer2372 4 жыл бұрын
nice video
@rw5838
@rw5838 3 жыл бұрын
Greetings! I absolutely love your video. I am a rookie. May I ask a question? I am trying to "make sense" of the wiring for the auxiliary contact (red jumper and yellow wire). Which one is the grounded (neutral) contact? Since the jumper is coming from what appears to be the "hot" wire and the yellow is coming from the "hot" start wire, why doesn't this result in a short-circuit. I guess if I were to ask the question differently, I see the 120v loop for the coil with a grounded and ungrounded conductor. But for the contact, which kne is grounded and which one is ungrounded? Any help is necessary and thank you for taking time to review my question.
@AccessToPower
@AccessToPower 3 жыл бұрын
Hello and thanks for watching and commenting. If you look at the video and go to minute marker 6:08, you will see the red wire from number three going to the coil and to one side of the normally open auxiliary. And you will see the yellow wire coming from our hand off auto to the other side of the auxiliary. Keep in mind that both of these conductors are fed from the same power source. They are basically the same wire except at the red goes through the normally open start button and the yellow does not. The yellow effectively bypasses the start button. As for the ground in neutral conductor that is coming from terminal 95 on the overload directly to the other side of the coil. Since the red and the yellow that I mentioned earlier are basically the same wire, there is no potential difference between them and that’s why there is no short.
@rw5838
@rw5838 3 жыл бұрын
@@AccessToPower Thank you so much for your kind response! This made perfect sense to me when you pointed out that they both come from the same source, which is why there is no potential difference. Your videos have really helped me apply many of the concepts in the NEC Code Book. Thank you so much for all of your awesome videos!!!
@tgsharp1158
@tgsharp1158 Жыл бұрын
High-quality videos.
@nicholasthomas856
@nicholasthomas856 3 жыл бұрын
How to wire a duplex pump circuit
@nukeelda
@nukeelda 5 жыл бұрын
Amazing keep it up ...
@nickledimez4012
@nickledimez4012 4 жыл бұрын
Beautiful explanation! I learned more from you than in my class. Have you considered a manual or book on this subject? I have text books from school but loaded with a lot of jargon. Your explanation is straight to the point and concise. Thank you sincerely!
@AccessToPower
@AccessToPower 4 жыл бұрын
NICKLE& DIMEz I don’t have any books yet. It is a long term goal though
@jessel2805
@jessel2805 2 жыл бұрын
@@AccessToPower please do!!!!!!
@rjwatford
@rjwatford 2 жыл бұрын
Is there anything saying the overload aux contact is required to be on the neutral side of the contactor coil?
@AccessToPower
@AccessToPower 2 жыл бұрын
if the coil is 120 volt then the neutral would go through the NC OL contact. If the coil is 240 volt then you would run Line 2 through the OL. Same goes for a 480 volt coil, you would run line 2 through the coil. This kills power to the coil if the OL trips. If you dont use the OL contacts then the OL will not turn off the starter in the event of a overload.
@boundless8288
@boundless8288 4 жыл бұрын
Nice practical application set up
@zakirhayat337
@zakirhayat337 5 жыл бұрын
SIR I TAKE VERY HELP FROM YOUR VIDEOS
@JuanMorales-mb3bf
@JuanMorales-mb3bf Жыл бұрын
Great video
@nickledimez4012
@nickledimez4012 4 жыл бұрын
He is a pro! Thank you!
@rommeldc4787
@rommeldc4787 4 жыл бұрын
Thanks! It so useful
@nicholasthomas856
@nicholasthomas856 3 жыл бұрын
230v 1hp
@michaelcostello6991
@michaelcostello6991 Жыл бұрын
Great
@monzurhasan3583
@monzurhasan3583 3 жыл бұрын
Lots of love 💖
@vijiganesan7310
@vijiganesan7310 5 жыл бұрын
Sirhowcaniwiringcontrol2SARTAR.SINGLEPHASESUBERBLEMOTORSARTAR
@samuelpowell87
@samuelpowell87 4 жыл бұрын
Good job
@stanley1826
@stanley1826 5 жыл бұрын
Great Video!!
@mariolopez1
@mariolopez1 2 жыл бұрын
This information is Gold. Thanks for taking the time to make this video.
@robertgregory2618
@robertgregory2618 5 жыл бұрын
Well done...
@nyustdent
@nyustdent 3 жыл бұрын
can the floar switch also be a REMOTE SCADA control like from a DCS? would that be a 24v signal coming in to control a relay to close this contact?
@AccessToPower
@AccessToPower 3 жыл бұрын
Yes that would work
@zakirhayat337
@zakirhayat337 5 жыл бұрын
Thank u Sir. I realy love you. Sir you expline very good.
@edwardgarza5104
@edwardgarza5104 3 жыл бұрын
What's the reason to used a lower voltage for control? Could they make the coil on the motor starter 480v coil and would eliminate the transformer?
@MackLife87
@MackLife87 Жыл бұрын
Late but, 120 is safer for hand control in the case of a short
@rajinig1599
@rajinig1599 5 жыл бұрын
Good, please show float switch also practically!
@syedazhar5014
@syedazhar5014 4 жыл бұрын
Sir can u explain in brief
@petersmith9254
@petersmith9254 5 жыл бұрын
Once again thank you for this videos will you do something with drives or vfds
@AccessToPower
@AccessToPower 5 жыл бұрын
you're welcome. yes I am getting ready for a vfd video now.
@stanleykania7184
@stanleykania7184 4 жыл бұрын
Nice job 👌
Basic Motor Control: 3 wire Start Stop Circuit
11:12
AccessToPower
Рет қаралды 275 М.
Basic Motor Control: Pump control panel wiring
7:34
AccessToPower
Рет қаралды 38 М.
The Joker wanted to stand at the front, but unexpectedly was beaten up by Officer Rabbit
00:12
Как подписать? 😂 #shorts
00:10
Денис Кукояка
Рет қаралды 8 МЛН
My Daughter's Dumplings Are Filled With Coins #funny #cute #comedy
00:18
Funny daughter's daily life
Рет қаралды 5 МЛН
How to Wire a PLC Control Panel Like a Pro
9:06
Bee Automation
Рет қаралды 112 М.
Basic Motor Control: 3 Wire Start Stop Circuit (updated)
7:43
AccessToPower
Рет қаралды 211 М.
Troubleshooting a Motor Starter
10:45
AccessToPower
Рет қаралды 323 М.
Wastewater Panels and Floats
20:49
Goulds Water Technology
Рет қаралды 5 М.
Motor Controls: Using an Ice Cube Relay to Start a VFD
6:23
AccessToPower
Рет қаралды 29 М.
Ladder Diagram Basics #3C 3 Wire Control
15:57
Pete Vree
Рет қаралды 68 М.
Hand - Off - Auto Selector Switch with a Float for Pump Control
5:04
Phil McInally
Рет қаралды 2,5 М.
MCC Buckets Explained "the motor control center"
6:59
Jason's World of Insightful Things
Рет қаралды 21 М.
Basic Motor Control: Jogging Circuit
9:04
AccessToPower
Рет қаралды 29 М.
Hahn Equipment: City of Tyler Flygt Pump Breakdown 1 of 2
33:12
Jason Van Alstine
Рет қаралды 39 М.
The Joker wanted to stand at the front, but unexpectedly was beaten up by Officer Rabbit
00:12