You completely answered every question I had after discovering my two vents were, A) Vented into the attic, and B) not hooked to any tubing at all, and completely blocked by insulation...Thanks for a great and straight to the point video!!
@JesusLoves...9 ай бұрын
Mine was the same way
@mike549966 ай бұрын
Same!
@davidcastelli789325 күн бұрын
@@mike54996 me 3
@greentea22254 жыл бұрын
Very informative. Thanks!
@SinnisjInsulator3 жыл бұрын
I am very surprised there is not more mold present. I've seen this issue a hundred times and typically the whole cavity is black. Installing an exit at the roof and insulating the exhaust hose is definitely the way to go. I can also tell the Insulation is way too low and would benefit in air sealing it before topping it up. Great explanation.
@sunnyspaces72 жыл бұрын
If the cavity is molded a bit or black....how is it fixed ? Yes, properly vent the exhaust ...but how is the mold area taken care of ?. thanks for your response
@pearlperlitavenegas20232 жыл бұрын
Thanks my house was built in 84 and nothing exhausts to the outside except for the vent pipes 😳 I'll have to go look where my bathroom fan is venting to??? I'm guessing the attic
@sondon710310 ай бұрын
So far, so good! I installed this fan yesterday. kzbin.infoUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh I've been watching a continuous radon monitor in my house for about a week, and the levels have been running between 4.5 and 7.9 pCi/L. Shortly after I installed this fan, the radon level started dropping, and in less than 24 hours since I installed it, the level is now 1.9. My basement is approximately 2,000 square feet. Total home square footage above basement is approximately 4,000 square feet. The noise level so far is very quiet. Mine is installed indoors, so I had to purchase a cord and connector. If I have any problems later, I'll update my review. But for now, I'm very pleased with it.Update after 48 hours: Using a constant monitor, my radon is now fluctuating between 0.38 and 0.45 pCi/L. I've moved the monitor to my basement and am getting a constant 0.43 reading. After 24 hours, and when I know the weather will be safe, I'll place the monitor outside for about 12 hours. I'm thinking that the 0.38 to 0.45 may be the outside "ambient" radon level. I'm using this monitor (purchased from Amazon): Corentium Home Radon Detector by Airthings 223
@heroknaderi2 жыл бұрын
Great info. Ill take it.
@jeu1985 ай бұрын
Or if a condenser was added to the vent in the attic that drains in to the soil stack or radiator header tank (which presumably had an overflow pipe right?) then might the loft not benefit from intermittently being warmed by now dry air. Unless of course the condenser merely reduces the moisture content warm air should dry any moisture that condensed in the loft from the use of the unconditioned extracted bathroom air.
@jeu1985 ай бұрын
Whooo! The loft venting bathroom extractor I am correcting is in an annoying house with no gable end, a square mushroom 🍄 shape roof. I DEFINITELY don't want to introduce a hole to a 100 year old roof and the soffit is six inches at most and vents in to the rest of the house. There is however a chimney! Can I vent in to that?
@jeannedigennaro64842 жыл бұрын
This is so important to avoid mold build up. It’s( mold or mildew)an expensive thing to remediate.
@greg30873 ай бұрын
Great…but I thought this video would show me how.
@xternalpunk Жыл бұрын
Dang that's a lot of mold!!! Nothing to mess with and they need to fix that before it gets worse!
@packetattack74373 жыл бұрын
Wait you can't use a 45 degree tap to connect into an existing pipe? Why not? The pipe sizing up there would have more than enough CFM exhaust capacity to handle two fans running at the same time. Please clarify.
This sounds like a dumb question. My vent is also placed at the soffit. Can I put an elbow out from the soffit vent and face it away from the house? Would this be as efficient?
@nwohiohomeinspector3 жыл бұрын
Not a dumb question at all! Your upper vents are constantly "pulling air" from those lower soffit vents, in order to keep your attic well ventilated. A short elbow is not really going to help much or do anything as the conditioned/moisture-laden air from your shower steam will likely linger around those soffit vents and still get "sucked" right back in to the building envelope. If you extended it out further, maybe, however, it's going to be an eyesore. Hope this helps & thanks for watching!
@rvwjboi233 жыл бұрын
@@nwohiohomeinspector thanks for the response. My house is brick all the way up and i dont want to core thru brick and I agree with you about less holes on the roof. I dont want to drill up the roof neither.
@animalchin58613 жыл бұрын
I have no gable end on my ranch. Soffit vent is the best option? It seems like a hole in the roof is way worse and more likely to let more moisture in
@athenawrightson69183 жыл бұрын
Could you run it to the ridge vent rather then the gable?
@nwohiohomeinspector3 жыл бұрын
Not a good idea.
@toomanynarcissistshere21023 жыл бұрын
@@nwohiohomeinspector why?
@bowold3976 Жыл бұрын
They are designed to be terminated through gable vents or roofing goose necks that come with air tight adapters. If a roofer installs the goose neck correctly you dont have to worry about it leaking.
@The_Cyberz Жыл бұрын
@@toomanynarcissistshere2102you’ll rot the wood around the ridge vent
@Waderizer3 жыл бұрын
Gable venting is ok, but insulated flex, in the attic, will condense and fill the flex with water. Agree the soffit is poor choice. The roof is ideal, get a roofer to install the vent. It is short, quick, and cheep.
@nwohiohomeinspector3 жыл бұрын
If the fan is sized properly and the insulated duct runs straight out (not uphill), condensation shouldn't be an issue.
@vapeurdepisse Жыл бұрын
LOL nothing about roofing is cheap.
@Mkx563 жыл бұрын
How do you vent into the gable ends?
@nwohiohomeinspector3 жыл бұрын
Run the piping on top of the ceiling joists under the insulation or run an insulated duct to the gable end. Cut the hole out and install a bath vent hood w/damper. I wish there was a way to post pictures/graphics.
@tonkatuffnuts3 жыл бұрын
@@nwohiohomeinspector You can post pictures to www.imgur.com and comment with links - I also am unclear I guess. It may be because I've never seen the top of a bathroom fan but I am unclear on how to connect the piping to the ceiling fan itself.
@cheryllowery454 ай бұрын
What does it cost to correct this issue? I have this situation in a house I am buying.
@nwohiohomeinspector4 ай бұрын
You should always get a couple of estimates from local and trusted contractors so you have something tangible to present to the seller for negotiation purposes. There's many, many variables that come into play, but I'd say a guesstimate of $175 - $300 per fan.
@cheryllowery454 ай бұрын
Thank you! I am getting a local estimate also. @@nwohiohomeinspector
@sunnyspaces72 жыл бұрын
How far away from the soffit vent should the exhaust fan vent ?
@nwohiohomeinspector2 жыл бұрын
I wouldn't vent into a ventilated soffit if you don't have to. If necessary, I'd keep at least three to four feet away. I have another YT video about soffit venting you can check out.
@sunnyspaces72 жыл бұрын
@@nwohiohomeinspector thank you for your response. Also...if the area is molded a bit or black....how is it fixed ? Yes, properly vent the exhaust ...but how is the mold area taken care of ?. thanks for your response
@nwohiohomeinspector2 жыл бұрын
Just needs cleaned off. This stuff works well: www.rmrsolutions.com/products/rmr-86-pro?variant=48382662863
@fatherelijah17633 жыл бұрын
nice video 👍 or whatever
@rogerchampjr9332 жыл бұрын
Unfortunately your not allowed by code to exhaust into the gable
@nwohiohomeinspector2 жыл бұрын
What? What code? Why on earth wouldn't you be able to vent out a gable end?
@rogerchampjr9332 жыл бұрын
Well Florida code it has to be directly exhausted outside not in a gable, not into a soffit, not into a ridgeline, but directly
@nwohiohomeinspector2 жыл бұрын
@@rogerchampjr933 Show me. Where else are you going to vent it if you can't vent it through a gable end, besides the roof?
@bowold3976 Жыл бұрын
Yea it doesnt actually state that anywhere in the code. It just needs to be terminated outside amd not be closer than 3 feet to any opening or intake system on the house. Aswell a backdraft damper must be used
@patglenn57054 жыл бұрын
please stop saying "or whatever".
@nwohiohomeinspector3 жыл бұрын
Alrighty then, thx for the tip Pat!
@jdubdoubleu3 жыл бұрын
And "um". Other than that, good video
@porkchop13433 жыл бұрын
Pat Glenn “ what ever”
@doctaC072 жыл бұрын
@@nwohiohomeinspector Dude say whatever as much as you want. Everyone's a critic.