I have researcher interview tomorrow and this video helped me to clear the required basics, Thanksss🎉
@ArnavPadhi3 жыл бұрын
Can u plz explain how different conc of the antibiotic solutions were made and their serial dilutions? 2. How much volume of bacteria was inoculated? 3. How much volume of the drug was added to the 96 well plate?
@henrikslab3 жыл бұрын
1. You have measured the stock concentration. Use c1 x V1 = c2 x V2 to dilute to highest serial dilution. Then prepare serial dilutions by using half water half compound... (I will do a video about that soon) 2. 190µl 3. 10µl Make sure that it can vary from protocol to protocol (for details and further questions, the paper in the video description might be interesting for you!)
@Lanakalana2 жыл бұрын
That was such a clear explanation thankuuu
@arghayeaye4591 Жыл бұрын
Hello, at 4:20 there is a two fold decrease in concentrations and we concluded that the most diluted that prevents the growth is MIC. But how can we be sure that 4µg/ml is the MIC instead of say, 3µg/ml, a value in between 4 and 2 that cannot be observed by 2 fold decrease?
@henrikslab Жыл бұрын
We can not be entirely sure. You can narrow that done like you said by testing intermediate steps.
@enriquevines5911 Жыл бұрын
There is an infinite number of dilutions that can be made between 2 and 4, rendering the search for a "more accurate" value useless
@sanaamoha56452 жыл бұрын
Thank you so much You explained it very well.🙏🏼
@nurulsuhana99743 жыл бұрын
for the bacterial culture, how it can be changed from 1x10^8 cfu/ml to 5x10^5 cfu/ml when we need to transfer to 96 well plate ? can u explain the step
@henrikslab3 жыл бұрын
1. Transfer 1ml of 1x10^8 to 9ml medium (mix it -> 1x10^7) 2. Transfer 1ml of 1x10^7 to 9ml medium (mix it -> 1x10^6) 3. Transfer 5ml of 1x10^6 to 5ml medium (1:1 -> after mixing it is 5x10^5)
@joshuaeni9464 Жыл бұрын
Thanks for this explanation
@tetrahydrocannabinol58632 жыл бұрын
Thank you so much
@moxiemania5 ай бұрын
Corrections... The dilution of the drug is not serial* it's a doubling dilution
@Olee_04152 ай бұрын
doubling is one of the serial dillution method
@franciswalsh54692 жыл бұрын
Excellent, Thank you
@anshikapal28162 жыл бұрын
Thank you so much 💗
@SamuelAsumadu-l2sАй бұрын
Nice video
@minesi..49042 жыл бұрын
Thank you very much🌸🌸🌸
@youngscientistjomel2 ай бұрын
May i l know what isbthe total volume in each well containing bacteria and drugs is it 100ul or 200 ul?
@yiwuzheng3547 Жыл бұрын
I also a little bit confuse about the selection of concentrations, why the mic is 4 rather than 3, or any value between 2-4
@Holy_Randomness Жыл бұрын
To determine the MIC of an antibiotic, a series of concentrations corresponding to the power of 2 were taken i.e 1, 2, 4, 8..... Since evaluating all the concentrations from 1 to 32 would be practically tedious. Once you have narrowed down your concentration range from the initial assay, then you can proceed for further assays to determine an even accurate MIC value, in this case the concentration range could be between 2.5 to 4.5 ug/ml.
@batsiraichinomona85872 жыл бұрын
Well explained video.. Thank you
@prodbytj82712 жыл бұрын
amazing video
@Jaybee_23 Жыл бұрын
what are the measurements when you use this method for fungi?
@noorfalak6341 Жыл бұрын
Plz share the link if disc diffusion method of microbial control of yours۔۔
@ayat45222 жыл бұрын
thank you a lot
@olanma.o7 ай бұрын
Thank you for this video ! Do you have one on MBC?
@henrikslab7 ай бұрын
Hi, not yet, no :D
@asdbio Жыл бұрын
Good evening, can we use this method to compare between antimicrobial effect of different solutions? Which wavelength should be used?
@henrikslab Жыл бұрын
Yes, it is used for comparing the antimicrobial efficacy of different solutions. Regarding the wavelength: It depends on the type of solution being tested. Some antimicrobial agents work by absorbing light at specific wavelengths, and the efficacy of these agents can be enhanced by exposing the microorganisms to light at the appropriate wavelength.
@eswinipi Жыл бұрын
Is there any mathematical way to calculate MIC90 considering the results you got?