Carrying out an EICR - an overview of what we do!

  Рет қаралды 13,828

Justin Bucknell Electrical Ltd

Justin Bucknell Electrical Ltd

Жыл бұрын

We carry out an Electrical Installation Condition Report on a property near High Wycombe.
This video gives you an idea of what we typically do to in this process, some observations we found and what happens with the results at the end, plus more.
On this particular property we found a lot of observations that require remedial action. This customer had used an electrician previously but they failed to highlight some of the obvious and very serious observations on their previous visits. In some cases it appears they created some of the observations we found by their own workmanship.
📸 JBE Socials 📸
🎥 Justin Bucknell Electrical TikTok account
/ justinbucknellelectrical
📸 Justin Bucknell Electrical InstaGram
www.instagram/jbe_and_motionev
📸 Justin Bucknell Electrical Facebook
/ justinbucknellelectrical
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own legal risk.

Пікірлер: 59
@matthewfewings6023
@matthewfewings6023 Жыл бұрын
10mm main earth on TT will be fine on adiabatic equation.
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
Absolutely 💯
@robertdybell6604
@robertdybell6604 Жыл бұрын
He's right gents as there is no additional mechanical protection to the main earthing conductor outside.
@matthewfewings6023
@matthewfewings6023 Жыл бұрын
@@robertdybell6604 ?
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
Adiabatic would prove this unnecessary and the cables not buried the rod is. I'd argue this is absolutely safe a c3 at best as it doesn't meet the current regulations but is safe for continued use
@tresslerj1985
@tresslerj1985 Жыл бұрын
Minimum size for non protected earthing conductor is 4mm2.
@jonathanstephens7804
@jonathanstephens7804 5 ай бұрын
liking the older Megger you don't see too many used like that anymore. Good video guys
@chrisrose9600
@chrisrose9600 Жыл бұрын
Excellent job sir, Bundy and Artisan have got a strong competitor !!
@vascar21
@vascar21 Жыл бұрын
Really enjoyable and knowledgable video. Yes, KZbin is plagued with lots of videos and I’ve also seen numerous videos before in EICR’s, but this was nice and clear, camera and sound work are very good and all in all very professional 👍🏾
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Thank you for you feedback much appreciated 👍
@jamesmc1272
@jamesmc1272 Жыл бұрын
This 100mA rcd main switch was the thing to do in the 15th/16th regs for TT systems so can only be coded as an observation. In my humble opinion.
@mainlineelectronics5266
@mainlineelectronics5266 Жыл бұрын
It wasn't just the 15/16 edition, its 100/300/500ma time delayed RCDs are still used today for fault protection on TT earthing.
@stevendavies4006
@stevendavies4006 Жыл бұрын
Awesome video by the way!
@stevendavies4006
@stevendavies4006 Жыл бұрын
Some cutouts are only capable of taking 16mm tails . The black plastic cutout should have been reported to the Dno as a c17 and should of been upgraded .
@brianasgarali4355
@brianasgarali4355 Жыл бұрын
Well done. Any checks though on the circuit directory being up to date and that there are no overloaded circuits?
@davideyres955
@davideyres955 Жыл бұрын
Isn’t 16mm sufficient for 80 amps? Couldn’t really tell but the meter tails from the cut out looked like 16mm so you’d expect a max of 80amp fuse if they are 16mm.
@gregs7490
@gregs7490 4 ай бұрын
The new artisan electrical
@alvina69
@alvina69 Жыл бұрын
The 100mA S-Type RCCB is probably correct for a TT installation but I suspect it would additional protection by means of a 30mA RCD for each final circuit.
@rjkelectrical6086
@rjkelectrical6086 Жыл бұрын
It was common in older boards to see 100 mA upfront RCD to provide fault protection to the meter tails and busbar inside the consumer unit.
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
Yes the regulations require 100ma S type for fault protection and 30mA for additional protection for sockets (below 32a) and lighting (domestic only)
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
You can also see some 30mA rcbos after the 100mA main switch.
@jamesmc1272
@jamesmc1272 Жыл бұрын
This 100ma rcd main switch was ok in the 15th/16th regs for TT systems so can only be coded as an observation
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
@james mc you're opening a bag of worms with that argument; do we test to the regs when it was installed or now 🤔
@iancoles1349
@iancoles1349 3 ай бұрын
All good but I think sometimes we going over the top and forgetting the foundations are getting washed away my laddys.Although the coperate look without a hair out of place cool for the girls I do think u a load of dadys boys but hay u are cool Electricians.
@billsbasementworkshop1902
@billsbasementworkshop1902 Жыл бұрын
Hi, Do you really have to Earth an SWA cable both ends? I was told that it only needs to be one end.
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Only one end needs to earth to connect the SWA strands.
@andy.underwater.videos
@andy.underwater.videos 9 ай бұрын
Only one end must be earthed.
@electricalservicesmaroc
@electricalservicesmaroc Жыл бұрын
❤❤❤🎉🎉🎉 By the way what is the name of the cameras you used to filming this video 📸📷📷
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
We are using a filming company to record and edit our videos however we have the similar equipment like the Panasonic S5 and Rode wireless go 2 Thanks for your feedback
@electricalservicesmaroc
@electricalservicesmaroc Жыл бұрын
@@justinbucknellelectrical thanks 😊
@mikethemask1525
@mikethemask1525 Жыл бұрын
You need to freshen up on the knowledge side i ain't saying your bad sparkie but 16mm tails are perfectly fine, TT earth is perfectly exceptable at 10mm, the fire foam is just a preference regs doesn't say anything about fire proofing, even the armour on the SWA may not need earthing depending on how you read the regs.
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Thanks for your feedback. Cutting the knock outs out the back of a fire rated consumer and leaving a gap around the cables that lead into the cavity of the property is not acceptable and that partly defeats the point of having a fire rated consumer. No electrician who takes pride in his work would do that in the first place. Whilst this video was about an EICR we have been completing other work at this property fitting an EV charger and outside lighting and more. So we have changed the main earth to the earth electrode from 10mm to 16mm. I believe we have fitted this in accordance with table 54.1 of BS7671 page 198.
@mikethemask1525
@mikethemask1525 Жыл бұрын
@@justinbucknellelectrical like I say its up to you but TT earth can go down to 4mm if certain measures are met I use 10mm all the time. Again its down to choice are the spread of fire the regs say metal consumer unit or steel or in some sort of fireproof box but did you know you don't even have to use fire rated Grommets or stuffing glands an so on, the thing is the regs are not strict enough or to the point in my opinion they always leaves grey areas which results in different interpretation and and understanding
@jamesmc1272
@jamesmc1272 Жыл бұрын
The thing about EICR's is that you need a good knowledge or what was ok in previous edds of the Regs.
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Appreciate your input.
@Mike_5
@Mike_5 Жыл бұрын
You need to read the Regs again properly if you want to keep your Certification ...
@billsbasementworkshop1902
@billsbasementworkshop1902 Жыл бұрын
The 100mA RCCB, Would this not be for fault protection? Sorry if this seems to be a stupid question.
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
The 100mA RCCB on this consumer unit covers all circuits and then there are 2no 30mA RCBO’s covering 2 socket circuits, there’s also other circuits requiring 30mA protection that is not fitted.
@mainlineelectronics5266
@mainlineelectronics5266 Жыл бұрын
@@justinbucknellelectrical The 100ma rcd was fitted for fault protection. And selectivity.
@pault4793
@pault4793 Жыл бұрын
Great to see anybody put there work up for view , but i think a little more training on EICR is needed , certain things you suggest about earthing sizes is not quite correct.
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Hi Paul, Thanks for this, I will look into this and discuss with our QS. 👍
@justinbucknellelectrical
@justinbucknellelectrical Жыл бұрын
Whilst this video was about an EICR we have been completing other work at this property fitting an EV charger and outside lighting and more. So we will have changed the main earth to the earth electrode from 10mm to 16mm. I believe we have fitted this in accordance with table 54.1 of BS7671 page 198. I suppose in any instance it’s better to have an oversized earthing conductor than undersized.
@shaniapearcey
@shaniapearcey Жыл бұрын
All a bit serious 😮
@leightonsmith7003
@leightonsmith7003 5 ай бұрын
Domestic installers lol
@leightonsmith7003
@leightonsmith7003 5 ай бұрын
16mm earth are you sure did you calculate your adiabatic don’t think you did jokers stop using copper you don’t need
How to do an EICR start to finish - Electrical Safety Inspection and Test
46:34
Mark The Sparky Allison
Рет қаралды 58 М.
How I do EICR Testing | Thomas Nagy
18:27
Thomas Nagy
Рет қаралды 109 М.
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 15 МЛН
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 654 М.
How Bad Are Electrics In Thailand? 🇹🇭
20:12
Artisan Electrics
Рет қаралды 92 М.
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 164 М.
Pilot Tries Dangerous & Illegal Approach!
13:21
Pilot Debrief
Рет қаралды 282 М.
What electrical work are you allowed to do in your own home?
10:39
Day-in-the-life of an ELECTRICIAN
6:40
Karly the Sparky
Рет қаралды 151 М.
Electrical Test Procedure For A New Fuseboard - Electricians Life
35:11
Business EV charging solution: EV Charger installation - Ratio i07
33:31
Justin Bucknell Electrical Ltd
Рет қаралды 536