Earth Fault Detect Feature, Simplex 4100U and ES

  Рет қаралды 10,666

FireAlarm Tech

FireAlarm Tech

Күн бұрын

Пікірлер: 14
@vinothvno7640
@vinothvno7640 10 ай бұрын
Nice information 🎉
@balaramsamal84
@balaramsamal84 Жыл бұрын
Hi how to remove ground negative fult
@ZubairKhan-qo4fi
@ZubairKhan-qo4fi Жыл бұрын
Hello sir I have 4100u and I faced some issues. Will you help me?
@achannelwithnopurpose1977
@achannelwithnopurpose1977 2 жыл бұрын
Very cool video. I really wanna become a simplex tech myself so i can learn these panels and mess around with them and make systems work for clients of all types. I do though have a question about es.exe: I was modifying my simplex 4007es demo board and reprogramming it with its matching programmer (6.01.03). One day the computer decided it didn’t want to connect to the 4007es when i decided to dump in a new config. I used an ethernet cable which was connected correctly and the service jumper was in the proper position. A restart of my pc fixed the issue. What exactly could’ve caused es.exe to act up like it did, and have you had the same problem?
@Rgidhkfel
@Rgidhkfel 2 жыл бұрын
Yes, rebooting seems to work for me but most of the newer “hybrid” 4007’s the Ethernet ports don’t work and you have to download using the usb method
@rodriguesrodrigo
@rodriguesrodrigo 11 ай бұрын
1:00 On my panel I have "idnet earth fault" but when I go to the diagnosis and click on find it appears "end of list" as if there was no earth fault
@firealarmtech4100
@firealarmtech4100 11 ай бұрын
A ground on an ID-NET circuit will not effect the ground reference on the system, but isolated only to that ID-NET circuit. It pretty much tells you what circuit that a ground fault exist.
@rodriguesrodrigo
@rodriguesrodrigo 11 ай бұрын
@@firealarmtech4100 There is an earth fault on loop board 2, so I: Select Earth Fault Search. Select the Idnet M2 and found the M2-39 device, which is an idnet isolator, however in the field I checked the isolator module and the connection is not touching any casing or piping
@gunawanwarsita9410
@gunawanwarsita9410 2 ай бұрын
Have you found the trouble sir? I have same issue right now
@rodriguesrodrigo
@rodriguesrodrigo 2 ай бұрын
@@gunawanwarsita9410 We discovered that there was a ball valve with the printed circuit wet, causing a ground fault in the monitor module. To resolve this, we disconnected this valve from the monitor module.
@gunawanwarsita9410
@gunawanwarsita9410 2 ай бұрын
Thanks for your reply, appreciated it
@uuuxxxo
@uuuxxxo 11 ай бұрын
Hello sir. What does 'master a class trouble' mean? How can I reset it?
@firealarmtech4100
@firealarmtech4100 11 ай бұрын
A master class A trouble means the fire panel has detected an "open" in a circuit that leaves the panel, then returns. If there's a break anywhere in the loop the panel will switch power/communication to the return side of the loop thus back feeding the broken half to maintain integrity. When the break in the wiring has been located and repaired, resetting the fire panel will switch the power/communication back and resume monitoring of the loop.
EARTH FAULT - Fire Detection and Alarm System
17:36
FIRE PROTECTION GUY
Рет қаралды 8 М.
Fire Alarm Training
15:07
Kevin Jones
Рет қаралды 244 М.
Мама у нас строгая
00:20
VAVAN
Рет қаралды 12 МЛН
4100U TO ES UPGRADE
21:51
FireAlarm Tech
Рет қаралды 1,6 М.
32 - Metering a Ground Fault - Introduction to Fire Alarms
16:03
Joe Klochan
Рет қаралды 62 М.
Inside the Simplex 4100ES
7:49
David Redpath
Рет қаралды 31 М.
ECC-50/100 Ins & Outs
16:51
Firealarm Discovery
Рет қаралды 855
HOW TO OPERATE SIMPLEX 4100ES FIRE ALARM SYSTEM FULL DEATILES.
29:15
FIRE ALARM SYSTEM BMTVK
Рет қаралды 12 М.
Trouble in the night fire alarm problems and troubleshooting
26:03
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 21 М.
Simplex 4100ES Programming Video  1 of 5
13:30
TECH. CHANNEL
Рет қаралды 7 М.
NAC Replacement
17:43
FireAlarm Tech
Рет қаралды 4,5 М.
How to use Simplex 4100ES  - Basic Operation -  Part 1
6:46
TECH. CHANNEL
Рет қаралды 6 М.