Fernox TF1 Filter Service & Maintenance

  Рет қаралды 80,135

Emerson Swan, Inc.

Emerson Swan, Inc.

Күн бұрын

Пікірлер: 18
@viko2273
@viko2273 3 жыл бұрын
An educating one. Thanks a lot from a Hungarian viewer. As you disassembled the filter air should have been vent out trough the top shiny screw on the top. If you just release the magnet to let the dirty water out it is fine not to air vent as the system remains air tight.
@Tampo-tiger
@Tampo-tiger 6 жыл бұрын
Just excellent, thank you very much from a UK viewer.
@mastard780
@mastard780 4 жыл бұрын
Shouldn't you vent the air out from the top of the TF1 before opening the exit and supply valves? I loosen the flat head screw to allow air to escape and then crack the supply valve to fill the TF1 until a solid stream of water comes out. Or do I just let my auto vents do their thing?
@delwalker6336
@delwalker6336 Ай бұрын
Thank you!
@unboxmeuk
@unboxmeuk 2 жыл бұрын
I spoke to them directy and theses comments below are not right, You did it right, You do not need to one the top for cleaning. only the bottom.
@deanosborne6037
@deanosborne6037 3 жыл бұрын
Great Video, however, the air should be vented prior to opening the filter back to the system and the top can be unscrewed for 2 reasons. 1, Cleaning and 2, For dosing the system with inhibitor or cleaning agents etc...
@peggy3377
@peggy3377 3 ай бұрын
Hi,when yo start clean tf1 filter you need turn off all system?
@ChristianBower-sz6qi
@ChristianBower-sz6qi Жыл бұрын
Can you add system inhibitor through the TF 1 ?
@florinadrian5174
@florinadrian5174 3 жыл бұрын
2:10 You did something at the top of the filter which wasn't in the frame. What?
@MaterialSquid
@MaterialSquid 4 жыл бұрын
thanks for this
@davidgeorge6382
@davidgeorge6382 4 жыл бұрын
kevin you made it look so easy can you come round and show me again only joking great job thank you
@sebmeister67
@sebmeister67 6 жыл бұрын
in the manual it shows that the draining is done with the valve above the filter, you've done it with the one underneath. which valve should i open and will there be any air stuck in the system?
@geraldbrown2840
@geraldbrown2840 5 жыл бұрын
I have always thought that the instruction manual shows using the wrong valve!
@onlyme972
@onlyme972 8 ай бұрын
Top valve open would drain from your boilers pump or heat exchanger. Better to use the bottom valve.
@johanna4nails424
@johanna4nails424 Жыл бұрын
I still have a leak after cleaning my filter 😬
@milanduro5721
@milanduro5721 6 күн бұрын
you forgot to vent the filter at the end
@petersharpe742
@petersharpe742 Жыл бұрын
Why do Americans drone on and on, taking hours to tell us what can be explained in minutes.
Cleaning a Fernox TF1 Filter: You Won't Believe the Results!
7:39
Fix it with Fowler
Рет қаралды 9 М.
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
Что-что Мурсдей говорит? 💭 #симбочка #симба #мурсдей
00:19
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Curățare filtru anti-magnetită FERNOX TF1 COMPACT
5:12
Iulian Solo
Рет қаралды 97 М.
Cleaning a Fernox TF1 magnetic filter
5:37
Butler Plumbing Heating & Gasfitting Ltd.
Рет қаралды 88 М.
Čištění magnetického filtru
2:14
Marek Dudáš
Рет қаралды 10 М.
A long time shoemaker showed me this secret! great tool.
9:19
Creation Secret
Рет қаралды 27 М.
Using A Magnaclean To Add Fernox F1
5:13
5 Minute Man
Рет қаралды 30 М.
FERNOX TF1 COMPACT INSTALLATION - Plumbing Tips
5:15
plumberparts
Рет қаралды 93 М.